Reference Guide

Arguments
arg1 =
name
Detailed Description None
Recommended Response Action If unexpected, check presence, then re-install or reconnect.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC5002
Message A fabric mismatch detected on
arg1
.
Arguments
arg1 =
name
Detailed Description The fabric type for the IOM and mezzanine cards must match. Once an IOM or
mezzanine card is inserted into the chassis, the fabric type is then set for the CMC and
the CMC will ensure that all subsequent IOMs and mezzanine cards match.
Recommended Response
Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine
card.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC5003
Message
arg1
is operating correctly.
Arguments
arg1 =
name
Detailed Description None
306