Reference Guide

SubCategory HWC = Hardware Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC5036
Message A failure is detected on IO module
arg1
.
Arguments
arg1 =
number
Detailed Description The IOM module performance may be impact.
Recommended Response Action Contact technical support. Refer to your product documentation to choose the
contact method that is convenient for you.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC6000
Message The
arg1
controller is offline.
Arguments
arg1 =
name
Detailed Description Information and status from the controller is unavailable.
Recommended Response Action Remove and reapply input power. If problem persists, contact technical support.
Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
312