Reference Guide

Detailed Description An error occurred while trying to set the firmware update mode.
Recommended Response
Action
Verify that the firmware version supports this mode. Also confirm that the command
and parameters are correct. The parameter choices are: 1) Disable "0" (default) 2)
Allow version upgrade only "1" 3) Match firmware of replaced part "2"
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC004
Message Provisioning Server information is not formatted correctly.
Detailed Description The Provisioning Server parameter information is not formatted correctly.
Recommended Response
Action
Verify the string format. Enter a valid IP address or hostname for the Provisioning
Server such as: 1) hostname 2) hostname.domain.com 3) 1.1.1.1 4) hostname:8080 5)
hostname.dell.com:8080 6) hostname1:80,hostname2:8080
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC005
Message Invalid firmware update mode.
Detailed Description The value provided for the update mode parameter is invalid.
Recommended Response Action Verify that the correct firmware update mode was entered. The choices are: 1)
Disable (default) "0" 2)Allow version upgrade only "1" 3) Match firmware of replaced
part "2"
Category Configuration
SubCategory LC = Lifecycle Contr
334