Reference Guide

Trap/EventID 2265
LCD Message Multi-bit memory error on <location>. Reseat memory
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM0002
Message Parity memory errors detected on a memory device at location
arg1
.
Arguments
arg1 =
location
Detailed Description The memory is operational. This is an early indicator of a possible future
uncorrectable error.
Recommended Response Action Re-install the memory component. If the problem persists, contact technical support.
Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM0003
Message Stuck bit memory error detected on a memory device at location
arg1
.
Arguments
arg1 =
location
Detailed Description The memory is operational. This is an early indicator of a possible future
uncorrectable error.
Recommended Response Action Re-install the memory component. If the problem persists, contact technical support.
Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
390