Reference Guide

LCD Message Memory mirror lost on <location>. Power cycle system
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM1206
Message Memory mirror redundancy is degraded. Check memory device at location
arg1
.
Arguments
arg1 =
location
Detailed Description The memory may not be seated correctly, misconfigured, or has failed.
Recommended Response Action Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health
SubCategory MEM = Memory
Severity Severity 2 (Warning)
Trap/EventID 2266
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM1207
Message Memory spare is redundant.
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory MEM = Memory
Severity Severity 3 (Informational)
Trap/EventID 2267
LCD Message No LCD message display defined.
Initial Default. LC Log
411