Reference Guide

Recommended Response Action Review product documentation for proper memory riser installation and
configuration
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Memory riser mismatch detected. Check memory riser
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM8000
Message Correctable memory error logging disabled for a memory device at location
arg1
.
Arguments
arg1 =
location
Detailed Description Errors are being corrected but no longer logged.
Recommended Response Action Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message SBE log disabled on <location>. Reseat memory
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
MEM8001
Message Persistent correctable memory error logging enabled for a memory device at
location
arg1
.
Arguments
arg1 =
location
Detailed Description None
Recommended Response Action No response action is required.
415