Reference Guide

Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD20
Message Unable to get size or label from Driver Pack for selected operating system.
Detailed Description Unable to get the size or label for selected operating system from the Driver Pack
present in Lifecycle Controller. The driver pack may be corrupt.
Recommended Response Action Update the Driver Pack using USC or DUP and rerun the command.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD21
Message Unable to boot to ISO image.
Detailed Description Booting to ISO has failed. Either BIOS was unable to boot to the ISO image or the
provider did not get a response in 5 minutes from BIOS on successful boot to ISO
image.
Recommended Response
Action
1) Make sure that a POST error did not result in user interaction (Press F1 to continue or
F2 to run BIOS setup). 2) Reset iDRAC and rerun the command.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None