Reference Guide

Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PCI3004
Message Device option ROM on mezzanine card
arg1
failed to support Link Tuning or
FlexAddress.
Arguments
arg1 =
number
Detailed Description Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not
support FlexAddress.
Recommended Response Action Update BIOS, BMC/iDRAC, and mezzanine card firmware. If problem persists please
contact customer support.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID 2417
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PCI3005
Message Device option ROM on mezzanine card
arg1
was successfully updated.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID 2419
LCD Message No LCD message display defined.
Initial Default. LC Log
486