Reference Guide

PST0194
Message Remote access controller configuration failed.
Detailed Description System BIOS could not configure the Remote Access controller This exception
occurred early in system power on, thus the system may not display video. (BIOS
POST exception code C2)
Recommended Response
Action
Cycle input power and power on the system. If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message Remote access controller configuration failed. Check screen message
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PST0195
Message CPU configuration failed.
Detailed Description The current processor configuration is unsupported or encountered a fatal
exception during POST. Check the processor configuration. This exception occurred
early in system power on, thus the system may not display video. (BIOS POST
exception code C3).
Recommended Response Action Review system processor configuration and reduce the system to the minimum
configuration.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message CPU configuration failed. Check screen message
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
522