Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0006
Message Power supply
arg1
is incorrectly configured.
Arguments
arg1 =
number
Detailed Description Power supplies should be of the same input type and power rating.
Recommended Response Action Install matched power supplies and review product documentation for proper
configuration.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Power supply <number> is incorrectly configured. Check PSU.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0007
Message Power supply
arg1
is operating at 110 volts, and could cause a circuit breaker fault.
Arguments
arg1 =
number
Detailed Description A power supply that is designed to operate at 220V, but is connected to a 110V power
source requires additional current for operation. The additional current may trip circuit-
breakers or cause other electrical issues with the input source.
Recommended Response
Action
Check input power source and cabling. Use recommended input power. Review the
product documentation. If the issue persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.