Reference Guide

PSU0035
Message An over voltage fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action Check input power, replace or re-install the power supply. If the issue persists,
contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Over voltage fault on PSU <number>. Check PSU
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0036
Message An over current fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed Description This failure may be the result of an electrical issue with cables or subsystem
components in the system.
Recommended Response
Action
1) Remove and re-install the power supply. 2) Check cables and subsystem
components in the system for damage. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message An over current fault detected on PSU <number>. Check PSU.
Initial Default. LC Log
533