Reference Guide

Recommended Response
Action
Check input power. Re-install the power supply. If problem persists contact support.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU0913
Message Power unit
arg1
is operating normally.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU0914
Message A predictive failure detected on power unit
arg1
.
Arguments
arg1 =
number
Detailed Description Status from the power supply indicates a power supply exception occurred. The
power supply will try to operate. System Performance and power redundancy may
be degraded or lost.
Recommended Response Action Remove input power and re-install supply at the next service window.
Category System Health
SubCategory PSU = Power Supply
544