Reference Guide

Severity Severity 1 (Critical)
Trap/EventID 4233
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
PSU12
Message Power supply was removed from
arg1
.
Arguments
arg1 =
enclosure name
Detailed Description An enclosure PSU was removed and is no longer functioning in optimal condition.
Recommended Response Action Re-insert the PSU into the enclosure. Contact technical support if the issue persists.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU2
Message The power supply in
arg1
is switched OFF.
Arguments
arg1 =
enclosure name
Detailed Description The power supply is not providing any power. This may be because the power supply
switch is in the off position or the power supply has failed.
Recommended Response
Action
Reseat the power supply, check the cable connection and verify the power supply is
turned on. See the storage hardware documentation for more information.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 4234