Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2402
Message Power management firmware not responsive.
Detailed Description The iDRAC controller cannot communicate with the power management firmware.
The system may operate in a performance degraded state.
Recommended Response
Action
"1) Disconnect system input power, wait one minute, reconnect system input power.
2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision."
Category System Health
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2403
Message Power management firmware responsive
Detailed Description The iDRAC controller established communication to the power management
firmware. System performance returns to normal.
Recommended Response Action No response action is required.
Category System Health
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
570