Reference Guide

Detailed Description One of more fans have failed or have been removed or a configuration change
occurred which requires additional fans.
Recommended Response Action Remove and re-install failed fans or install additional fans.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 1 (Critical)
Trap/EventID 2473
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
RDU0011
Message The power supplies are redundant.
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID 2475
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
RDU0012
Message Power supply redundancy is lost.
Detailed Description The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended Response Action Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health
673