Reference Guide

SubCategory RDU = Redundancy
Severity Severity 1 (Critical)
Trap/EventID 2473
LCD Message Lost PSU redundancy. Check PSU cables
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
RDU0013
Message Power supply redundancy is degraded.
Detailed Description The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended Response Action Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 2 (Warning)
Trap/EventID 2474
LCD Message PSU redundancy degraded. Check PSU cables
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
RDU0014
Message The power supplies are not redundant.
Detailed Description The current power supply configuration does not meet the platform requirements to
enable redundancy. If a power supply fails the system may shut down.
Recommended Response Action If unintended, review system configuration and power consumption and install
power supplies accordingly. Check power supply status for failures.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
674