Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
ASR0002
Message The watchdog timer powered off the system.
Detailed Description The operating system or an application failed to communicate to the baseboard
management controller (BMC). The system powered off per the configured setting.
Recommended Response Action Check the operating system, application, hardware, and system event log for
exception events.
Category System Health
SubCategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
ASR0003
Message The watchdog timer power cycled the system.
Detailed Description The operating system or an application failed to communicate to the baseboard
management controller (BMC). The system powered cycled per the configured
setting.
Recommended Response Action Check the operating system, application, hardware, and system event log for
exception events.
Category System Health
SubCategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
72