Reference Guide

SEL1501
Message Chassis management controller (CMC) redundancy is lost.
Detailed Description An action or failure has taken place that breaks CMC redundancy. This includes loss
of network connection, hardware failures, firmware update, firmware mismatch
between CMCs, CMC reset, and unplugging a CMC.
Recommended Response
Action
Check CMC network cables and network connections. Check that CMC firmware
versions match.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SEL1502
Message Chassis management controller (CMC) redundancy is degraded.
Detailed Description An action or failure has taken place that degrades CMC redundancy. This includes
firmware mismatch between CMCs and a CMC missing SD card.
Recommended Response Action Chassis management controller (CMC) redundancy is degraded.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SEL1503
Message The chassis management controller (CMC) is not redundant.
Detailed Description None
Recommended Response Action No response action is required.
739