Reference Guide

Detailed Description The operating system or an application failed to communicate to the system board
within the timeout period. The system was reset per the configured setting. (IPMI
sensor type code 23h offset 01h event 3:0 - 2h)
Recommended Response Action Check the operating system, application, hardware, and system event log for
exception events.
Category System Health
SubCategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
ASR0101
Message The OS watchdog timer reset the system.
Detailed Description The operating system or an application failed to communicate within the timeout
period. System was reset. (IPMI sensor type code 23h offset 01 - event 3:0 - 3h if
booting 4h if running)
Recommended Response Action Check the operating system, application, hardware, and system event log for
exception events.
Category System Health
SubCategory ASR = Auto Sys Reset
Severity Severity 1 (Critical)
Trap/EventID 2233
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
ASR0102
Message The OS watchdog timer shutdown the system.
74