Reference Guide

STOR0108
Message Temperature probes are not connected to enclosures or data about temperature is
unavailable.
Detailed Description No temperature data to display. The system is powered off, no enclosure temperature
probes are present in the system, or the temperature probes are not connected to the
enclosures.
Recommended Response
Action
Check if the server has power, enclosure temperature probe is available, and
temperature probe is connected to the enclosure.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR0109
Message Power supply unit is not connected to the enclosure or data about power supply unit is
unavailable.
Detailed Description No power supply unit data to display. The system is powered off, no power supply unit
is present in the system, or the power supply unit is not connected to the enclosure.
Recommended Response
Action
Check if the server has power, enclosure power supply unit is available, and power
supply unit is connected to the enclosure.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR011
Message Stripe size not supported on controller
751