Reference Guide

Recommended Response
Action
See the storage hardware documentation for information on checking the cables.
Check for problems with any enclosures attached to the system. Verify that the
controller has a supported version of the driver and firmware. Rebooting the system
may resolve this problem.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
Trap/EventID 4178
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
STOR2
Message SCSI sense data
arg1
.
Arguments
arg1 =
args
Detailed Description A SCSI device experienced an error, but may have recovered.
Recommended Response Action No response action is required.
Category Storage
SubCategory STOR = Storage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR3
Message CEM Storage Management has lost communication with the
arg1
.
Arguments
arg1 =
Controler Name
Detailed Description Storage Management has lost communication with a controller. This may occur if
the connectivity between the controller and iDRAC is disrupted or any underlying
hardware problems are encountered.
774