Reference Guide

Recommended Response
Action
Reboot the system or iDRAC. If the problem is not resolved, contact technical
support.
Category Storage
SubCategory STOR = Storage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR4
Message CEM Storage Management encountered internal error.
Detailed Description There was a software problem in initializing the CEM storage management
components. Storage inventory and monitoring will be affected.
Recommended Response Action Reboot the system or iDRAC. If the problem is not resolved, contact technical
support.
Category Storage
SubCategory STOR = Storage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR5
Message Redundancy lost.
arg1
Arguments
arg1 =
VD/Enclosure Name
Detailed Description A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more
physical disks included in the virtual disk have failed. Due to the failed physical disk or disks,
the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an
additional physical disk will result in lost data. In the case of an enclosure, more than one
enclosure component has failed. For example, the enclosure may have suffered the loss of all
fans or all power supplies.
775