Reference Guide

LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR011
Message Unable to collect Hardware Inventory information.
Detailed Description Hardware Inventory data collection and export has failed.
Recommended Response
Action
Enter system services to enter Unified Server Configurator (USC), and select exit and
reboot option in USC to instantiate the database, if Collect System Inventory on
Restart (CSIOR) is not enabled. If the hardware inventory database is present, reboot
the Integrated Remote Access Controller (iDRAC)and retry.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR012
Message Unable to collect Lifecycle Controller data.
Detailed Description Lifecycle Controller data collection and export has failed.
Recommended Response
Action
1. Download and apply the Dell Update Package (DUP) for USC. 2. Run System Services
to update the database if CSIOR is not enabled. 3. Reboot the system and retry. If these
operations fail, download the Field Service Repair software and repair the Lifecycle
Controller. Download and install all the DUPs for USC, diagnostics, driver packs, and
device firmware of all the devices of the host system.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. LC Log
83