Reference Guide

SWC0129
Message Unable to send test email. Please make sure that your email alerts\nhave been
configured correctly and connectivity to \nthe SMTP server exists.
Detailed Description Racadm tool was not able to send a test email for the configuration.
Recommended Response Action Check for the parameters mentioned in the message.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SWC0130
Message Trap at specified index is not currently enabled.
Detailed Description The Trap needs to be set for the particular index for the testtrap to go through.
Recommended Response Action Set cfgIpmiPetAlertEnable in cfgIpmiPet group using config subcommand for the
corresponding index.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SWC0131
Message Trap destination address must be configured.
Detailed Description The destination Ip address must be configured for the Trap.
Recommended Response Action Set cfgIpmiPetAlertDestIpAddr in cfgIpmiPet group using config subcommand for
the corresponding index.
841