Reference Guide

Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC4004
Message A firmware or software incompatibility detected between iDRAC in slot
arg1
and
CMC.
Arguments
arg1 =
number
Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update
the firmware.
Recommended Response Action Check firmware versions of iDRAC and CMC. Update to latest version.
Category System Health
SubCategory SWC = Software Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC4005
Message A firmware or software incompatibility was corrected between iDRAC in slot
arg1
and CMC.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. LC Log
910