Reference Guide

TMP0110
Message The memory module
arg1
temperature is outside of range.
Arguments
arg1 =
number
Detailed Description Ambient air temperature is too warm or cool.
Recommended Response Action Check system operating environment and review event log for fan failures.
Category System Health
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message Memory module <number> temperature is outside of range. Check Fans
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
TMP0111
Message The memory module
arg1
temperature is within range.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory TMP = Temperature
Severity Severity 3 (Informational)
Trap/EventID 2163
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
934