Reference Guide

TMP0205
Message CPU
arg1
temperature is within range.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory TMP = Temperature
Severity Severity 3 (Informational)
Trap/EventID 2163
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
TMP1
Message
arg1
exceeded the maximum warning threshold.
Arguments
arg1 =
tempsensor name
Detailed Description The enclosure is too hot. A variety of factors can cause the excessive temperature. For
example, a fan may have failed, the thermostat may be set too high, or the room
temperature may be too hot.
Recommended Response
Action
Check for factors that may cause overheating. For example, verify that the enclosure fan
is working. You should check the thermostat settings and examine whether the enclosure
is located near a heat source. Make sure the enclosure has enough ventilation and that
the room temperature is not too hot. Refer to the enclosure documentation for more
diagnostic information.
Category Storage
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
Trap/EventID 4210
LCD Message No LCD message display defined.
Initial Default. SNMP Alert