Detailed Description The destination address of the email is not configured.
Recommended Response Action Configure the email alert destination address and retry the operation.
Category Configuration
SubCategory TST = Test Alert
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
TST103
Message Missing parameters
arg1
Arguments
arg1 =
parameter names
Detailed Description One or more required parameters needed for the operation are missing.
Recommended Response Action To provide the correct parameters, see Lifecycle Controller-Remote Services
documentation.
Category Configuration
SubCategory TST = Test Alert
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
TST104
Message SNMP traps not configured.
Detailed Description The SNMP trap being tested is not properly configured.
Recommended Response Action Configure the SNMP trap and retry the operation. If the failure persists, reset iDRAC.
Category Configuration
SubCategory TST = Test Alert
Severity Severity 2 (Warning)
954