Reference Guide

Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR31
Message Controller cache is preserved for missing or offline
arg1
.
Arguments
arg1 =
VD Name
Detailed Description The controller is getting disconnected from its virtual disk, while Input Output (IO) is in-
progress.
Recommended Response
Action
Try importing foreign disks, if any. Check if the enclosure containing the Virtual Disk is
disconnected from the controller. Insert any disks that are reported missing or failed. If
the enclosure or disks were removed intentionally, the preserved cache can be
discarded. See storage hardware documentation for more information on performing
these steps.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 2 (Warning)
Trap/EventID 4354
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
VDR32
Message Background initialization has started for
arg1
.
Arguments
arg1 =
virtual disk
Detailed Description Background initialization of a virtual disk has started. This is an automated process
that writes the parity or mirror data on newly created virtual disks.
Recommended Response Action No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
986