Reference Guide

VDR49
Message
arg1
is permanently degraded.
Arguments
arg1 =
VD Name
Detailed Description A redundant virtual disk has lost redundancy. This may occur when the virtual disk
suffers the failure of more than one physical disk. In this case, both the source
physical disk and the target disk with redundant data have failed. A rebuild is not
possible because there is no longer redundancy.
Recommended Response
Action
Replace the failed disks and restore from backup.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR5
Message
arg1
was deleted.
Arguments
arg1 =
virtual disk
Detailed Description The controller removed a virtual disk. This is due to a delete virtual disk operation, a
reset configuration operation, or the removal of every physical disk that was a
member of the virtual disk.
Recommended Response Action No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
995