Reference Guide

VDR52
Message The consistency check found inconsistent parity data on
arg1
.
Arguments
arg1 =
virtual disk
Detailed Description The data on physical disk members of the virtual disk does not match. Redundancy may
be lost.
Recommended Response
Action
Rerun the consistency check task. If you receive this message again, verify the health of
the physical disks included in the virtual disk. See the storage hardware documentation
for more information. Review messages for significant messages related to the physical
disks. If a physical disk has a problem, replace it and restore from a backup copy.
Contact technical support if the issue persists.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 2 (Warning)
Trap/EventID 4354
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
VDR53
Message The consistency check logging of inconsistent parity data is disabled for
arg1
.
Arguments
arg1 =
virtual disk
Detailed Description The consistency check can no longer report errors in the parity data.
Recommended Response Action See the storage hardware documentation for more information on consistency
check operation. Contact technical support.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 2 (Warning)
Trap/EventID 4354
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
997