Reference Guide

VDR56
Message Redundancy of
arg1
was lost.
Arguments
arg1 =
virtual disk
Detailed Description This message occurs when a physical disk in the disk group was removed or when a
physical disk included in a redundant virtual disk fails. Because the virtual disk is
redundant (uses mirrored or parity information) and only one physical disk has failed,
the virtual disk can be rebuilt.
Recommended Response
Action
Replace the missing or failed physical disk.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR57
Message Background Initialization in
arg1
corrected medium error.
Arguments
arg1 =
VD Name
Detailed Description A disk media error was detected while the controller was completing a background
task. A bad disk block was identified. The disk block has been remapped.
Recommended Response Action Consider replacing the disk. If you receive this alert frequently, ensure to replace the
disk. It is recommended to routinely back up your data.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
999