Event and Error Message Reference Guide for 13th Generation Dell PowerEdge Servers Version 1.
Contents 1 Introduction....................................................................................................... 113 2 AMP Event Messages........................................................................................ 115 AMP0300............................................................................................................................................115 AMP0301..............................................................................................................
ASR0002............................................................................................................................................ 134 ASR0003............................................................................................................................................ 134 ASR0008............................................................................................................................................ 135 ASR0009.................................................
BAR023.............................................................................................................................................. 156 BAR024.............................................................................................................................................. 157 BAR025...............................................................................................................................................157 BAR026...............................................
BAR065.............................................................................................................................................. 179 BAR066.............................................................................................................................................. 179 BAR067.............................................................................................................................................. 180 BAR068...............................................
BAR107...............................................................................................................................................201 BAR108.............................................................................................................................................. 201 BAR109..............................................................................................................................................202 BAR110................................................
BAT1007............................................................................................................................................ 225 BAT1008............................................................................................................................................226 BAT1009............................................................................................................................................226 BAT1010...................................................
BIOS011............................................................................................................................................. 250 BIOS012............................................................................................................................................. 251 BIOS013............................................................................................................................................. 251 BIOS014..............................................
8 CBL Event Messages........................................................................................ 267 CBL0001............................................................................................................................................267 CBL0002........................................................................................................................................... 267 CBL0003..........................................................................................
CMC8525.......................................................................................................................................... 288 CMC8526.......................................................................................................................................... 288 CMC8527.......................................................................................................................................... 289 CMC8528.......................................................
CMC8577........................................................................................................................................... 311 CMC8578...........................................................................................................................................312 CMC8579...........................................................................................................................................312 CMC8601......................................................
CPU0819........................................................................................................................................... 336 CPU0822........................................................................................................................................... 336 CPU9000...........................................................................................................................................337 11 CPUA Event Messages.....................................
CTL22................................................................................................................................................ 360 CTL23................................................................................................................................................ 360 CTL24................................................................................................................................................ 361 CTL25.............................................
CTL60................................................................................................................................................ 387 CTL61.................................................................................................................................................387 CTL62................................................................................................................................................388 CTL63..............................................
CTL99................................................................................................................................................ 413 13 DH Event Messages........................................................................................ 414 DH001................................................................................................................................................414 DH002......................................................................................
DIAG0154..........................................................................................................................................430 DIAG0155.......................................................................................................................................... 430 DIAG0212...........................................................................................................................................431 DIAG0213....................................................
DIAG8005..........................................................................................................................................447 DIAG8006......................................................................................................................................... 448 DIAG8007......................................................................................................................................... 448 DIAG8008......................................................
DIS009.............................................................................................................................................. 466 DIS010...............................................................................................................................................466 DIS011................................................................................................................................................467 DIS012..............................................
ENC2................................................................................................................................................. 489 ENC21............................................................................................................................................... 490 ENC22................................................................................................................................................491 ENC23...............................................
FAN0016............................................................................................................................................ 515 FAN0017............................................................................................................................................ 516 FAN0018............................................................................................................................................ 516 FAN0019.................................................
FC012................................................................................................................................................ 536 FC013................................................................................................................................................ 536 FC014.................................................................................................................................................537 FC015.............................................
FLDC1027.......................................................................................................................................... 558 FLDC1028..........................................................................................................................................559 FLDC1029..........................................................................................................................................559 FLDC1030.....................................................
HWC1006.......................................................................................................................................... 581 HWC1007.......................................................................................................................................... 582 HWC1008..........................................................................................................................................582 HWC1009........................................................
HWC3006......................................................................................................................................... 606 HWC4000......................................................................................................................................... 607 HWC4001..........................................................................................................................................607 HWC4002..........................................................
HWC7008......................................................................................................................................... 630 HWC7010.......................................................................................................................................... 631 HWC7012...........................................................................................................................................631 HWC7014........................................................
27 IOV Event Messages.......................................................................................654 IOV000..............................................................................................................................................654 IOV001.............................................................................................................................................. 654 IOV002.........................................................................................
IOV115............................................................................................................................................... 674 IOV116............................................................................................................................................... 675 IOV117................................................................................................................................................675 IOV118............................................
ISM0022............................................................................................................................................ 692 ISM0023............................................................................................................................................ 692 30 JCP Event Messages...................................................................................... 693 JCP000.........................................................................................
LC003................................................................................................................................................ 707 LC004................................................................................................................................................708 LC005................................................................................................................................................708 LC006...............................................
LC043.................................................................................................................................................721 LC044................................................................................................................................................ 722 LC045................................................................................................................................................ 722 LC046.............................................
LIC005............................................................................................................................................... 735 LIC006............................................................................................................................................... 736 LIC007............................................................................................................................................... 736 LIC008............................................
LIC907............................................................................................................................................... 752 33 LNK Event Messages...................................................................................... 753 LNK0001............................................................................................................................................ 753 LNK0002......................................................................................
LOG503............................................................................................................................................. 770 LOG504..............................................................................................................................................771 LOG505..............................................................................................................................................771 LOG506..................................................
MEM1011........................................................................................................................................... 793 MEM1012........................................................................................................................................... 793 MEM1013........................................................................................................................................... 794 MEM1014....................................................
MEM9009.......................................................................................................................................... 817 36 NIC Event Messages.......................................................................................819 NIC001...............................................................................................................................................819 NIC002..........................................................................................
NIC515...............................................................................................................................................832 NIC516...............................................................................................................................................832 37 OSD Event Messages......................................................................................833 OSD062........................................................................................
OSD40...............................................................................................................................................846 OSD41............................................................................................................................................... 846 OSD42............................................................................................................................................... 847 OSD43.................................................
OSE1007............................................................................................................................................862 OSE1008........................................................................................................................................... 863 OSE1009........................................................................................................................................... 863 OSE1010....................................................
PCI3005............................................................................................................................................ 886 PCI3006............................................................................................................................................ 887 PCI3007............................................................................................................................................ 888 PCI3008.................................................
PDR1019.............................................................................................................................................911 PDR102...............................................................................................................................................911 PDR1020............................................................................................................................................912 PDR1021.................................................
PDR15................................................................................................................................................ 935 PDR16................................................................................................................................................936 PDR17................................................................................................................................................ 937 PDR18..............................................
PDR44............................................................................................................................................... 963 PDR46............................................................................................................................................... 963 PDR47............................................................................................................................................... 964 PDR48................................................
PDR84............................................................................................................................................... 989 PDR85............................................................................................................................................... 990 PDR86................................................................................................................................................991 PDR87................................................
PR21..................................................................................................................................................1011 PR22................................................................................................................................................. 1011 PR23.................................................................................................................................................1012 PR24............................................
PST0080..........................................................................................................................................1033 PST0081.......................................................................................................................................... 1034 PST0082..........................................................................................................................................1034 PST0083......................................................
PSU0000......................................................................................................................................... 1057 PSU0001..........................................................................................................................................1057 PSU0002......................................................................................................................................... 1058 PSU0003.......................................................
PSU0904......................................................................................................................................... 1082 PSU0906......................................................................................................................................... 1082 PSU0907......................................................................................................................................... 1083 PSU0908.......................................................
PSU8517...........................................................................................................................................1105 PSU8518.......................................................................................................................................... 1106 PSU8519.......................................................................................................................................... 1106 PSU8520....................................................
PWR204........................................................................................................................................... 1127 PWR205............................................................................................................................................1127 PWR206........................................................................................................................................... 1128 PWR207.....................................................
PWR2400.........................................................................................................................................1149 PWR2401......................................................................................................................................... 1150 PWR2402......................................................................................................................................... 1150 PWR2403........................................................
PWR8537..........................................................................................................................................1172 PWR8538......................................................................................................................................... 1172 PWR8539..........................................................................................................................................1173 PWR8540.......................................................
PWR8580.........................................................................................................................................1196 PWR8581......................................................................................................................................... 1196 PWR8582......................................................................................................................................... 1197 PWR8583........................................................
PWR8682......................................................................................................................................... 1219 PWR8683.........................................................................................................................................1220 PWR8684........................................................................................................................................ 1220 PWR8685.........................................................
RAC0130..........................................................................................................................................1235 RAC0131.......................................................................................................................................... 1235 RAC0132..........................................................................................................................................1236 RAC0133......................................................
RAC0212..........................................................................................................................................1249 RAC0213..........................................................................................................................................1249 RAC0214..........................................................................................................................................1250 RAC0215.......................................................
RAC0255..........................................................................................................................................1263 RAC0256......................................................................................................................................... 1263 RAC0257..........................................................................................................................................1264 RAC0259.......................................................
RAC0297.......................................................................................................................................... 1277 RAC0298..........................................................................................................................................1277 RAC030........................................................................................................................................... 1278 RAC0301.....................................................
RAC0512.......................................................................................................................................... 1291 RAC0513..........................................................................................................................................1292 RAC0514..........................................................................................................................................1292 RAC0516......................................................
RAC0624......................................................................................................................................... 1307 RAC0625......................................................................................................................................... 1307 RAC0626......................................................................................................................................... 1307 RAC0627.......................................................
RAC0666..........................................................................................................................................1321 RAC0667.......................................................................................................................................... 1321 RAC0668......................................................................................................................................... 1322 RAC0669......................................................
RAC0706..........................................................................................................................................1337 RAC0707..........................................................................................................................................1338 RAC0708......................................................................................................................................... 1338 RAC0709.......................................................
RAC0755..........................................................................................................................................1356 RAC0756..........................................................................................................................................1356 RAC0757.......................................................................................................................................... 1357 RAC0758......................................................
RAC1017...........................................................................................................................................1374 RAC1018.......................................................................................................................................... 1375 RAC1019.......................................................................................................................................... 1375 RAC1020....................................................
RAC1060......................................................................................................................................... 1396 RAC1061.......................................................................................................................................... 1397 RAC1062..........................................................................................................................................1397 RAC1063......................................................
RAC1142.......................................................................................................................................... 1420 RAC1143.......................................................................................................................................... 1420 RAC1144...........................................................................................................................................1421 RAC1145....................................................
RAC913............................................................................................................................................1442 RAC914............................................................................................................................................1443 RAC915............................................................................................................................................1443 RAC916.....................................................
RAC960............................................................................................................................................1461 RAC961............................................................................................................................................ 1461 RAC962........................................................................................................................................... 1462 RAC963....................................................
RDU0002........................................................................................................................................ 1483 RDU0003........................................................................................................................................ 1484 RDU0004........................................................................................................................................ 1484 RDU0005..........................................................
RDU8524......................................................................................................................................... 1507 50 RED Event Messages....................................................................................1509 RED000........................................................................................................................................... 1509 RED001..............................................................................................
RED038........................................................................................................................................... 1530 RED039........................................................................................................................................... 1530 RED040............................................................................................................................................1531 RED041.....................................................
RED081............................................................................................................................................ 1551 RED082............................................................................................................................................1552 RED083............................................................................................................................................1552 RED084....................................................
RFM1029.......................................................................................................................................... 1571 RFM1030..........................................................................................................................................1572 RFM1031.......................................................................................................................................... 1572 RFM1032.....................................................
SEC0032..........................................................................................................................................1592 SEC0033..........................................................................................................................................1592 SEC0034..........................................................................................................................................1593 SEC0040.......................................................
SEL1200........................................................................................................................................... 1614 SEL1202........................................................................................................................................... 1615 SEL1204........................................................................................................................................... 1615 SEL1205.................................................
SSD1003.......................................................................................................................................... 1637 SSD1004.......................................................................................................................................... 1637 SSD1005.......................................................................................................................................... 1638 SSD1006....................................................
STOR0205....................................................................................................................................... 1655 STOR0206....................................................................................................................................... 1655 STOR0207....................................................................................................................................... 1656 STOR0208.........................................................
STOR0506....................................................................................................................................... 1672 STOR0507....................................................................................................................................... 1672 STOR0508....................................................................................................................................... 1673 STOR0509.........................................................
STOR083.........................................................................................................................................1688 STOR084.........................................................................................................................................1688 STOR089.........................................................................................................................................1689 STOR090..........................................................
SUP001.............................................................................................................................................1710 SUP002............................................................................................................................................ 1710 SUP003............................................................................................................................................ 1710 SUP005..................................................
SUP015............................................................................................................................................ 1724 SUP016............................................................................................................................................ 1724 SUP017.............................................................................................................................................1724 SUP018..................................................
SUP0534.......................................................................................................................................... 1743 SUP0535.......................................................................................................................................... 1743 SUP0536..........................................................................................................................................1744 SUP0537.....................................................
SWC0026........................................................................................................................................ 1764 SWC0027.........................................................................................................................................1764 SWC0028.........................................................................................................................................1765 SWC0029..........................................................
SWC0068........................................................................................................................................ 1786 SWC0069........................................................................................................................................ 1786 SWC0070.........................................................................................................................................1787 SWC0071..........................................................
SWC0133.........................................................................................................................................1802 SWC0134.........................................................................................................................................1802 SWC0135.........................................................................................................................................1803 SWC0136..........................................................
SWC0214......................................................................................................................................... 1816 SWC0215......................................................................................................................................... 1816 SWC0216......................................................................................................................................... 1817 SWC0217.......................................................
SWC0256........................................................................................................................................ 1830 SWC0257.........................................................................................................................................1830 SWC0258......................................................................................................................................... 1831 SWC0259.........................................................
SWC0298........................................................................................................................................ 1844 SWC0299........................................................................................................................................ 1844 SWC0300........................................................................................................................................ 1845 SWC0301..........................................................
SWC1914......................................................................................................................................... 1859 SWC1915......................................................................................................................................... 1860 SWC1916......................................................................................................................................... 1860 SWC1917.......................................................
SWC8508........................................................................................................................................ 1882 SWC8509........................................................................................................................................ 1882 SWC8510.........................................................................................................................................1883 SWC8511..........................................................
SWC8607........................................................................................................................................ 1905 SWC8608........................................................................................................................................ 1906 SWC8609........................................................................................................................................ 1907 SWC8610..........................................................
SWU8526.........................................................................................................................................1929 SWU8527.........................................................................................................................................1929 SWU8528........................................................................................................................................ 1930 SWU8529..........................................................
SYS005............................................................................................................................................ 1950 SYS006............................................................................................................................................ 1950 SYS007............................................................................................................................................. 1951 SYS008.................................................
SYS051.............................................................................................................................................1968 SYS052............................................................................................................................................ 1969 SYS053............................................................................................................................................ 1969 SYS054..................................................
SYS093.............................................................................................................................................1987 SYS094............................................................................................................................................ 1987 SYS095.............................................................................................................................................1987 SYS096..................................................
SYS131.............................................................................................................................................2008 SYS132............................................................................................................................................ 2009 SYS133............................................................................................................................................ 2009 SYS134..................................................
SYS173.............................................................................................................................................2029 SYS174.............................................................................................................................................2029 SYS175.............................................................................................................................................2030 SYS177..................................................
TMP0122.........................................................................................................................................2050 TMP0123.........................................................................................................................................2050 TMP0124......................................................................................................................................... 2051 TMP0125.........................................................
TMP8502.........................................................................................................................................2073 65 TMPS Event Messages................................................................................. 2075 TMPS0100.......................................................................................................................................2075 TMPS0101.................................................................................................
UEFI0026........................................................................................................................................ 2093 UEFI0027........................................................................................................................................ 2094 UEFI0028........................................................................................................................................ 2094 UEFI0029......................................................
UEFI0068......................................................................................................................................... 2116 UEFI0069......................................................................................................................................... 2117 UEFI0070......................................................................................................................................... 2117 UEFI0071...................................................
UEFI0110......................................................................................................................................... 2140 UEFI0111..........................................................................................................................................2140 UEFI0112.......................................................................................................................................... 2141 UEFI0113..................................................
UEFI0152......................................................................................................................................... 2163 UEFI0153......................................................................................................................................... 2163 UEFI0154......................................................................................................................................... 2164 UEFI0155...................................................
UEFI0194......................................................................................................................................... 2187 UEFI0195......................................................................................................................................... 2187 UEFI0196......................................................................................................................................... 2188 UEFI0197...................................................
UEFI0236......................................................................................................................................... 2211 UEFI0237..........................................................................................................................................2211 UEFI0238......................................................................................................................................... 2212 UEFI0239...................................................
USR0005......................................................................................................................................... 2231 USR0007..........................................................................................................................................2231 USR0008......................................................................................................................................... 2232 USR0013.......................................................
USR105............................................................................................................................................2250 USR106............................................................................................................................................ 2251 USR107............................................................................................................................................ 2251 USR8500..................................................
VDR18..............................................................................................................................................2274 VDR19.............................................................................................................................................. 2275 VDR2................................................................................................................................................2275 VDR20.................................................
VDR56..............................................................................................................................................2301 VDR57............................................................................................................................................. 2302 VDR58............................................................................................................................................. 2303 VDR59...................................................
VF022...............................................................................................................................................2321 VF023...............................................................................................................................................2321 VF024.............................................................................................................................................. 2322 VF025................................................
VFL0012...........................................................................................................................................2335 VFL0013...........................................................................................................................................2335 VFL0014.......................................................................................................................................... 2335 VFL0015....................................................
VFLA1000........................................................................................................................................ 2353 73 VLT Event Messages.................................................................................... 2354 VLT0100.......................................................................................................................................... 2354 VLT0101............................................................................................
VLT0233.......................................................................................................................................... 2378 VLT0234.......................................................................................................................................... 2378 VLT0235.......................................................................................................................................... 2379 VLT0300....................................................
Introduction The Event Message Reference contains the error and event information generated by firmware and other agents that monitor system components. These events might be logged, presented to the user on one of the system management consoles, or both logged and displayed. Each event consists of the following fields: Message ID Message The unique alphanumeric identifier for the event.
Severity 3 Information Indicates a medium-to-low impact problem that involves a partial or noncritical loss of functionality; operations are impaired but can continue to function. LCD Message The event message text that is displayed on the system's LCD. Initial Default Event messages result in event actions such as logging, SNMP or email alerts. Generally, the event actions are configurable using the Dell iDRAC event action filtering feature.
AMP Event Messages AMP0300 Message The system board arg1 current is less than the lower warning threshold. Arguments arg1 = name Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* AMP0302 Message The system board arg1 current is greater than the upper warning threshold. Arguments arg1 = name Detailed Description Product documentation contains information on correct configuration.
Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health (AMP = Amperage) Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System board current is outside of range.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* AMP0305 Message The system board arg1 current is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* AMP0307 Message Disk drive bay arg1 current is less than the lower critical threshold.
Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
AMP0310 Message Disk drive bay arg1 current is outside of range. Arguments arg1 = name Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* AMP0312 Message System level current is less than the lower warning threshold. Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System level current is outside of range. Contact Support iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC AMP0314 Message System level current is greater than the upper warning threshold.
Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health (AMP = Amperage) Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System level current is outside of range.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC AMP0317 Message System level current is within range. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* AMP0319 Message Chassis power level current is less than the lower critical threshold.
Category System Health (AMP = Amperage) Severity Severity 2 (Warning) Trap/EventID 2178 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* AMP0321 Message Chassis power level current is greater than the upper critical threshold. Detailed Description Product documentation contains information on correct configuration.
Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
AMP400 Message The arg1 sensor has failed, and the last recorded value by the sensor was arg2 A. Arguments arg1 = sensor name, arg2 = current Detailed Description The current sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC AMP402 Message The arg1 sensor returned to a normal state with a value of arg2 A. Arguments arg1 = sensor name, arg2 = current Detailed Description The current sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider. Otherwise, change the warning threshold for the current sensor such that it corresponds to the hardware configuration.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC AMP405 Message The arg1 sensor state has changed to a failed state with a value of arg2 A. Arguments arg1 = sensor name, arg2 = current Detailed Description The current sensor identified in the message may be faulty. This condition can cause system performance issues and degradation in the moitoring capability of the system.
ASR Event Messages ASR0000 Message The watchdog timer expired. Detailed Description The operating system or potentially an application failed to communicate to the baseboard management controller (BMC) within the timeout period. Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC ASR0002 Message The watchdog timer powered off the system. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC). The system powered off per the configured setting.
Category System Health (ASR = Auto Sys Reset) Severity Severity 1 (Critical) Trap/EventID 2233 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC ASR0008 Message The watchdog timer interrupt was initiated.
Detailed Description The system is communicating to the baseboard management controller (BMC). Recommended Response Action No response action is required. Category System Health (ASR = Auto Sys Reset) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC ASR0100 Message The BIOS watchdog timer reset the system.
ASR0101 Message The OS watchdog timer reset the system. Detailed Description The operating system or an application failed to communicate within the timeout period. System was reset. (IPMI sensor type code 23h offset 01 - event 3:0 - 3h if booting 4h if running) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC ASR0103 Message The OS watchdog timer powered down the system. Detailed Description The operating system or an application failed to communicate within the timeout period. The system was powered down. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC ASR0105 Message The OS watchdog timer powered off the system. Detailed Description The operating system or an application failed to failed to communicate within the timeout period. The system was powered off.
Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
ASR0108 Message The system returned from an OS watchdog timer event. Detailed Description None Recommended Response Action No response action is required. Category System Health (ASR = Auto Sys Reset) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC ASR200 Message The watchdog timer expired at arg1 .
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC ASR201 Message The watchdog timer restarted the system at arg1 . Arguments arg1 = day month date hh:mm:ss yyyy Detailed Description The watchdog timer has restarted the system at the date and time identified in the message, because the operating system has crashed or hung.
OMSA Event ID Filter Visibility 5006 IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC ASR203 Message The watchdog timer performed an AC power cycle on the system at arg1 .
Recommended Response Action No response action required.
BAR Event Messages BAR001 Message Export System Profile requested. Detailed Description A system profile export operation has been requested. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR003 Message Preparing vFlash Backup partition. Detailed Description The Backup partition is being created for storing the backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR005 Message Collecting Lifecycle Controller data. Detailed Description The Lifecycle Controller data is being collected and copied into the backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR007 Message Export System Profile completed. Detailed Description System profile export operation is successfully completed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR009 Message Valid vFlash media not present. Detailed Description The vFlash media is not present on the system. Recommended Response Action Insert the appropriate vFlash media in the designated vFlash portal, enable and initialize it, and retry.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR011 Message Unable to collect Hardware Inventory information. Detailed Description Hardware Inventory data collection and export did not complete successfully. Recommended Response Action Enter system services to enter Unified Server Configurator (USC), and select exit and reboot option in USC to instantiate the database, if Collect System Inventory on Restart (CSIOR) is not enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR013 Message Host System Shutdown unsuccessful. Detailed Description The request to shut the Host system down did not complete successfully. Recommended Response Action Restart the Integrated Remote Access Controller (iDRAC) and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR015 Message Backup file data processing error. Detailed Description The Backup file information was not properly processed and the operation cannot continue. This can be due to resource constraints within the processing environment. If the network share is read only, this error will be thrown also.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR017 Message Backup file validation requested. Detailed Description A system profile backup file validation has been requested. Recommended Response Action No response action is required.
Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR019 Message Validating Restore operation, allow several minutes for this to complete. Detailed Description A system profile backup file validation is in progress. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR021 Message Insufficient space on network share.
Detailed Description The host system is powering up to perform component firmware and configuration restoration. Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR023 Message Starting component updates.
BAR024 Message Initializing Restore operation. Detailed Description The restoration environment is being initialized. Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR025 Message Restoring Component Firmware.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR026 Message Restoring Component Configuration. Detailed Description The configuration is being set for each component. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR028 Message Host System Component Restore completed with errors, shutting down Host System. Detailed Description The component restoration on the host system has completed, but there were errors. The Host System will shutdown. Recommended Response Action View configuration data and request attributes update for the components or retry system profile import.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR030 Message Import System Profile Complete, restarting Integrated Remote Access Controller. Detailed Description The import system profile is complete. iDRAC restarts to complete restore. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR032 Message Invalid system profile Backup file. Detailed Description The system profile backup file validation did not complete successfully. Recommended Response Action Do one of the following: 1) An incorrect passphrase may have been entered, correct the input and retry the operation.
Category Configuration (BAR = Backup/Restore) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR034 Message Unable to Restore Integrated Remote Access Controller firmware. Detailed Description The Integrated Remote Access Controller(iDRAC) firmware import did not complete successfully.
Recommended Response Action Manually reset the Integrated Remote Access Controller (iDRAC) configuration. Category Configuration (BAR = Backup/Restore) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR036 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery initiated.
Detailed Description Adjustments to Lifecycle and Integrated Remote Access Controller environments are complete. Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR038 Message Cancel.
BAR039 Message License not present. Detailed Description The license required for operation is not present. Recommended Response Action Use supported vFlash media and licensing for this feature, and try the operation again.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR041 Message System Shutdown. Detailed Description Shutting down host system. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR043 Message Timeout waiting for Unified Server Configurator to exit. Detailed Description A timeout occurred waiting for the Unified Server Configurator (USC) to exit. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR045 Message Powering down the Host System for Integrated Remote Access Controller Restore. Detailed Description The host system is powering down to facilitate the import of the Integrated Remote Access Controller system profile. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR047 Message System Profile operation canceled by user. Detailed Description The System Profile operation was canceled as part of a clean up operation performed during a restart of the Integrated Remote Access Controller. Recommended Response Action Resubmit the System Profile operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR049 Message Automatic Host System power up setup failed. Detailed Description The automatic Host System power up request has erred and the system will not power up after the Integrated Remote Access Controller has restarted. Recommended Response Action As indicated by the job status, wait for restore to complete.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR051 Message Performing Component Configuration Restore for Device : arg1 Arguments arg1 = device name Detailed Description The configuration import for the specified device is in progress. Recommended Response Action No response action is required.
device indicated will update the firmware storage partition. A backup of the server profile is recommended after updating. Recommended Response Action No response action is required.
BAR054 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery unsuccessful. Detailed Description The attempt to clean up after an unsuccessful Backup/Restore of a system profile operation has not been successful. The Lifecycle Controller/System Services related operations may not execute as expected until the system is properly restored to a functional configuration. Recommended Response Action Enter the iDRAC configuration utility.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR056 Message Component Configuration Restored on Device : arg1 Arguments arg1 = device name Detailed Description The configuration import was successful for the specified device. Recommended Response Action No response action is required.
Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR058 Message Validating NFS destination access. Detailed Description The system profile import or export network destination is being tested for access. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR060 Message Collecting firmware inventory information. Detailed Description Collecting firmware inventory and copying it into the system profile backup file.
Detailed Description Collecting system information and copying it into the backup file. The operation collects system information that includes System Model and Service Tag. Recommended Response Action No response action is required.
BAR063 Message Collecting Lifecycle Controller Firmware images. Detailed Description Collecting the Lifecycle Controller firmware images and copying them in the server profile backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR065 Message Collecting Integrated Remote Access Controller configuration. Detailed Description Collecting the Integrated Remote Access Controller configuration and copying it into the server profile backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR067 Message vFlash media not initialized. Detailed Description The system profile export destination is not initialized. Recommended Response Action Initialize the vFlash media and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR069 Message Insufficient space on vFlash media. Detailed Description The system profile export did not complete successfully because there is insufficient space on the vFlash media. Recommended Response Action Delete partitions and free up 384 MB of space on the current vFlash media, or use new vFlash media.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR071 Message CIFS Destination access denied. Detailed Description Access to the CIFS export/import destination is not possible or has been denied. Recommended Response Action Verify that the input parameters are correct, connectivity exists to the destination end point, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR073 Message Delete of vFlash Backup partition unsuccessful. Detailed Description The operation to delete the vFlash backup partition did not complete successfully. Recommended Response Action Enable and initialize the vFlash media and retry the export. If the error continues, try a new vFlash media or use the network share option(s).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR075 Message Unable to collect System information. Detailed Description The collection and export of system information failed. Recommended Response Action Restart the remote access controller, and retry the operation. If the error continues, use the remote access controller firmware to try the operation again.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR077 Message Unable to collect the Firmware images. Detailed Description The collection and export of host system firmware images was not successful. Recommended Response Action Apply Dell Update Packages for all devices and software, and try the operation again.
Category Configuration (BAR = Backup/Restore) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR079 Message Unable to collect the Integrated Remote Access Controller configuration. Detailed Description The collection and export of Integrated Remote Access Controller configuration was not successful.
Recommended Response Action No response action is required. Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR081 Message Restoring Lifecycle Controller Firmware images.
Detailed Description Remote access controller firmware and configuration import in progress. Recommended Response Action No response action is required.
BAR084 Message Host System Service Tag does not match the Backup file Service Tag. Detailed Description System profile backup file validation failed because the host system service tag information does not match the value stored in the file. Recommended Response Action Obtain a valid host system backup image and try the operation again. Reboot the remote access controller and try the operation again.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR086 Message Unable to Restore The Lifecycle Controller Configuration database. Detailed Description The system profile import of Lifecycle Controller configuration data has failed. Recommended Response Action If collect system inventory on reboot (CSIOR) is not enabled, enter and exit System Services in USC to update the database, reboot the system and try the operation again.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR088 Message No partitions available on vFlash media. Detailed Description The maximum number of partitions are already in use. Recommended Response Action Delete partitions and free up 384MB of space on the current vFlash media or obtain new vFlash media.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR090 Message System Profile Backup requested. Detailed Description A request to create a System Profile Backup file has been made by the user of the Unified Server Configurator interface. Recommended Response Action No response action is required.
Category Configuration (BAR = Backup/Restore) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR092 Message Disconnect from NFS unsuccessful. Detailed Description The attempt to disconnect from the specified NFS location was not successful.
Recommended Response Action If this happens on a backup request, restart the Integrated Remote Access Controller and try the operation again. If this is a restore request the Integrated Remote Access will be restarted during the execution of the request. Only restart the Integrated Remote Access Controller if it does not restart on its own.
Detailed Description The request to restore a System Profile from a Backup file did not complete successfully because there is already a request in progress. Recommended Response Action If possible monitor the in progress job for completion and then retry the request. If that is not possible try clearing all jobs and try the request again. If the issue persists, restart the Integrated Remote Access controller and try the request again.
BAR097 Message Lifecycle Controller Unified Server Configurator incompatibility detected. Detailed Description The current Lifecycle Controller Unified Server Configurator software installed on the system does not have Backup and Restore feature support. Recommended Response Action Obtain the Lifecycle Controller Unified Server Configurator update package with Backup and Restore support, update the software and try the operation again.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR099 Message Collecting License data. Detailed Description License data is being collected and copied into the backup Server Profile. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR101 Message Restoring License data. Detailed Description Importing license data from the backup Server Profile. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR103 Message Collecting system branding data. Detailed Description System branding data is being collected and copied to the backup Server Profile. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR105 Message Restoring system branding data. Detailed Description Importing system branding data from the Server Profile backup file. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR107 Message vFlash media reader license not present. Detailed Description The vFlash media reader requires a license to function. Recommended Response Action Obtain the license for vFlash media from your service provider. Install the license and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAR109 Message OEMDRV partition is in use. Detailed Description The OEMDRV partition is mounted for performing operating system deployment use. This situation prevents the Export and Import Server Profile operation from continuing. Recommended Response Action Dismount the OEMDRV partition by selecting F10 during boot and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BAR111 Message Server Profile operation timed out. Detailed Description The Import or Export job did not complete successfully. The Import or Export operation timed-out while validating or transferring Server Profile data.
Recommended Response Action Obtain a valid Server Profile file for the target system and try the operation again. If the problem reoccurs, restart the iDRAC and try the operation again.
Arguments arg1 = job ID Detailed Description The Automatic Backup job identified in the message is created per the Server Profile automatic export schedule previously configured. Recommended Response Action No response action is required.
BAR116 Message Unable to create a recurring export Server Profile job because an existing scheduled Backup Image job is scheduled within the next 24 hours. Detailed Description Unable to create a recurring export Server Profile job because an existing scheduled Backup Image job is scheduled within the next 24 hours. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy 207
BAT Event Messages BAT0000 Message The system board battery is low. Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the system board battery at the next service window.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* BAT0002 Message The system board battery has failed. Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the system board battery.
Recommended Response Action No response action is required. Category System Health (BAT = Battery Event) Severity Severity 3 (Informational) Trap/EventID 2227 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* BAT0004 Message The system board battery is absent.
BAT0005 Message The storage battery is low. Detailed Description The system has to remain powered on to charge the battery. Recommended Response Action Allow the PERC RAID controller battery to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC BAT0007 Message The storage battery has failed. Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC BAT0009 Message The storage battery is absent. Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation.
Recommended Response Action Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
BAT0012 Message The storage battery for disk drive bay arg1 has failed. Arguments arg1 = bay Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation for the associated bay. 2) Check the system logs for thermal related issues.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC BAT0014 Message The storage battery for disk drive bay arg1 is absent. Arguments arg1 = bay Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action Check the battery at the next service window. Category System Health (BAT = Battery Event) Severity Severity 2 (Warning) Trap/EventID 2226 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC BAT0016 Message The arg1 battery is operating normally.
BAT0017 Message The arg1 battery has failed. Arguments arg1 = name Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery. Category System Health (BAT = Battery Event) Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message The battery has failed. Check battery.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC BAT0019 Message The arg1 battery is absent. Arguments arg1 = name Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery to confirm presence.
Recommended Response Action Replace the the battery. Category System Health (BAT = Battery Event) Severity Severity 2 (Warning) OMSA Event ID 5703 OMSA Trap ID 5703 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BAT0031 Message The system board battery status is unknown.
BAT1000 Message Battery on arg1 is missing. Arguments arg1 = controller name Detailed Description The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message. Recommended Response Action Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling. In addition check the connection to the controller battery and the battery health.
OMSA Event ID 2175 OMSA Trap ID 115100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* BAT1002 Message The battery on arg1 learn cycle has started. Arguments arg1 = controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
BAT1003 Message The battery on arg1 learn cycle has completed. Arguments arg1 = controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 4274 OMSA Event ID 2178 OMSA Trap ID 115300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* BAT1005 Message The battery on arg1 learn cycle has been postponed. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
BAT1006 Message The battery on arg1 learn cycle will start in arg2 days. Arguments arg1 = Controller name, arg2 = arg Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 115100 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔* BAT1008 Message Write policy on arg1 was changed to Write Through. Arguments arg1 = controller name Detailed Description The controller battery cannot maintain cached data for the required period of time.
Arguments arg1 = controller name Detailed Description The controller battery health has returned to normal. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔* BAT1011 Message Battery on arg1 is in warn only mode and requires reconditioning. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description Diagnostic event for service to determine if there is an ambient temperature problem. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔* BAT1014 Message arg1 battery charge in-progress. Arguments arg1 = Controller name Detailed Description Diagnostic event for service to determine if there is an ambient temperature problem. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 4275 OMSA Event ID 2215 OMSA Trap ID 115100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ BAT1016 Message The arg1 battery learn mode has changed to Auto. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
BAT1017 Message The arg1 battery learn mode has changed to Warn. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 115300 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ BAT1019 Message Battery on arg1 is charging. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1022 Message arg1 battery recondition is completed. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description The battery health has returned to normal. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ BAT1025 Message arg1 is unable to recover cached data from the Battery Backup Unit (BBU). Arguments arg1 = controller name Detailed Description The controller was unable to recover data from the cache. This may indicate data loss has occurred. Recommended Response Action Verify that the battery is charged and in good health. See the hardware documentation for more information.
Recommended Response Action No response action is required. Category Storage (BAT = Battery Event) Severity Severity 3 (Informational) Trap/EventID 4275 OMSA Event ID 2338 OMSA Trap ID 115100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1027 Message The battery on arg1 completed a charge cycle.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ BAT1028 Message The battery voltage on arg1 is low. Arguments arg1 = controller name Detailed Description The controller battery voltage is low. This may indicate that the battery is no longer protecting the controller cache. Recommended Response Action The battery needs to recharged. Wait 24 hours to see if the charge is restored.
Severity Severity 1 (Critical) Trap/EventID 4273 OMSA Event ID 2169 OMSA Trap ID 115400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1030 Message The arg1 battery charge level is normal. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
BAT1031 Message The battery temperature on arg1 is above normal. Arguments arg1 = controller name Detailed Description The room temperature may be too hot. In addition, the system fan may be degraded or failed. Recommended Response Action Verify that the room temperature is normal and that fans are functioning properly. See the storage hardware documentation for acceptable operating temperatures.
OMSA Trap ID Filter Visibility 115100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ BAT1033 Message The battery on arg1 was removed. Arguments arg1 = controller name Detailed Description The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
BAT1034 Message The battery properties for arg1 have changed. Arguments arg1 = controller name Detailed Description One or more battery properties were modified. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC BAT1036 Message The battery on arg1 is discharging. Arguments arg1 = controller name Detailed Description The battery on the controller identified in the message is being discharged. Recommended Response Action No response action is required.
BIOS Event Messages BIOS001 Message The command was successful Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration (BIOS = BIOS Management) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS002 Message Resource allocation failure.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS003 Message Missing required parameter. Refer to the inserted comment. Detailed Description An invalid number of arguments was passed to the method. Recommended Response Action Enter all the required command parameters. Check documentation and try again.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS005 Message Mismatch in AttributeName and AttributeValue count Detailed Description The number of AttributeName and AttributeValue parameters do not match. Recommended Response Action Enter the same number of parameters for AttributeName and AttributeValue.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS007 Message Configuration job already created, cannot create another configuration job on specified target until existing job is completed or is cancelled Detailed Description A configuration job is already created on the specified target.
Recommended Response Action Change the configuration of one or more attributes and then create a configuration job. Category Configuration (BIOS = BIOS Management) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS009 Message Lifecycle Controller is currently in use.
Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS012 Message No pending data to delete. Detailed Description No changes to BIOS attribute data are available between the previous configuration and the current configuration. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS014 Message Invalid AttributeValue for AttributeName: arg1 Arguments arg1 = attribute name Detailed Description AttributeValue may be invalid because of the following causes: 1) Length of new AttributeValue is not within required minimum length and maximum length 2) Value of new AttributeValue is not within requir
Recommended Response Action No response action is required. Category Configuration (BIOS = BIOS Management) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS016 Message AttributeValue cannot be changed for disabled AttributeName arg1 .
Detailed Description Unable to delete vFlash pending one-time boot configuration. Recommended Response Action Remove AC power from system and after restoring AC power, retry the operation. Category Configuration (BIOS = BIOS Management) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC BIOS018 Message Invalid BIOS Password.
Severity Severity 2 (Warning) No alerts are applicable for this message BIOS022 Message Cannot set the BIOS password. Password is disabled due to a jumper setting on the motherboard. Detailed Description The BIOS password is disabled in the hardware using a jumper and can not be set. See the system owners manual for jumper location. Recommended Response Action Change the jumper setting on the system board to enable changing the BIOS password.
BIOS025 Message Unable set the BIOS password as the BIOS password status is locked. Detailed Description The status of the password is Locked in BIOS and must be set to Unlocked for the operation to succeed. Recommended Response Action Change BIOS password status in the BIOS setup from Locked to Unlocked and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔ Reset Chassis Event Proxy BIOS028 Message Unable to change the BIOS password using plain text because the password is currently being configured using a hash. Detailed Description The BIOS password cannot be simultaneously configured by using plain text and a hash.
Detailed Description The BIOS password cannot be configured because an Import Server Profile operation is already running. Recommended Response Action Wait until the current import operation is completed, and then retry the operation. Category Configuration (BIOS = BIOS Management) Severity Severity 2 (Warning) No alerts are applicable for this message BIOS101 Message Unable to read or change any of the system BIOS configuration settings.
Severity Severity 3 (Informational) OMSA Event ID 5002 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC BIOS103 Message A previously scheduled system BIOS update is canceled. Detailed Description A previously scheduled BIOS update job is cancelled. Recommended Response Action No response action is required.
BOOT Event Messages BOOT001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
BOOT004 Message Invalid number of Boot Source arguments Detailed Description An invalid number of source arguments was passed to the method. Recommended Response Action Check documentation and try again (details) Category Configuration (BOOT = BOOT Control) Severity Severity 3 (Informational) No alerts are applicable for this message BOOT005 Message Missing required parameter. Detailed Description One or more of the invoked methods required parameters are missing.
BOOT007 Message Boot Source does not belong to specified Boot Configuration Detailed Description One or more of the Boot Source instance IDs does not belong to the affected Boot Configuration. Recommended Response Action ChangeBootOrderByInstanceID only accepts Boot Sources from the impacted Boot Configuration. Verify that all source arguments belong to the desired Boot Configuration.
BOOT010 Message Could not locate vFlash partition index Detailed Description The provided vFlash partition index could not be found on the system. Recommended Response Action Verify that a vFlash partition with the desired index exists on the System.
BOOT013 Message Cannot make changes to non-active boot list. Detailed Description The boot list is currently not active. Changes cannot be made to boot list that is not active. Recommended Response Action Alter boot mode to set the boot list active and retry the operation. Category Configuration (BOOT = BOOT Control) Severity Severity 2 (Warning) No alerts are applicable for this message BOOT014 Message Virtual media not ready.
BOOT016 Message Input source argument value for the boot device is incorrect or not found among the boot devices on the system. Detailed Description The input source argument value referring to the boot device is incorrect or empty. The boot device identifier must match the InstanceID for the BootSourceSetting instance that represents the boot device. Recommended Response Action Use the correct source argument value for the boot device and retry the operation.
BOOT8500 Message Unable to change the BIOS boot order for the Server arg1 Arguments arg1 = slot number Detailed Description Unable to change the BIOS boot order for the server because of a broken communication between the CMC and iDRAC, or iDRAC is rebooting. Recommended Response Action Reset iDRAC or wait until iDRAC reboots, and retry the operation.
CBL Event Messages CBL0001 Message Backplane arg1 power cable disconnected. Arguments arg1 = bay ID Detailed Description A backplane signal cable was detected, but the accompanying power cable was not present. Recommended Response Action Reconnect or replace the power cable. If the issue persists, contact your service provider.
iDRAC LC Log LCD ✔* ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy CMC CBL0003 Message Backplane arg1 arg2 cable is disconnected. Arguments arg1 = bay ID, arg2 = cable name Detailed Description The backplane cable identified in the message is disconnected or no cable is detected. Recommended Response Action Reconnect or replace the cable identified in the message. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle ✔* ✔ WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy CMC CBL0005 Message Backplane arg1 arg2 connector incorrectly connected to the motherboard SATA controller. Arguments arg1 = bay ID, arg2 = connector name Detailed Description The backplane connector identified in the message is incorrectly connected to the motherboard SATA controller.
Recommended Response Action Make sure that only one RAID controller is connected to the backplane. If the issue persists, contact your service provider. Category System Health (CBL = Cable) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle ✔* ✔ WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy CMC CBL0007 Message Backplane arg1 arg2 cable and backplane arg3 arg4 cable are swapped.
Arguments arg1 = cable id, arg2 = expander id Detailed Description SAS cables are not connected to the expander correctly. Recommended Response Action Check whether or not the SAS cables are connected to the expander. Reconnect the cables and retry the operation. Category Storage (CBL = Cable) Severity Severity 1 (Critical) No alerts are applicable for this message CBL8501 Message SAS cable arg1 is connected to the incorrect expander.
CMC Event Messages CMC001 Message The operation is successfully completed. Detailed Description The operation is successfully completed. Recommended Response Action No response action is required. Category Configuration (CMC = Chassis Management Controller) Severity Severity 3 (Informational) No alerts are applicable for this message CMC002 Message Unable to complete the operation because of an unknown issue.
CMC004 Message Unable to complete the operation because the parameter arg1 is invalid. Arguments arg1 = parameter name Detailed Description The operation cannot be completed because the parameter identified in the message is invalid. Recommended Response Action Enter a valid parameter and retry the operation. For information about valid parameters, see the CMC Profile document available on the support site.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC CMC8501 Message Chassis Group Leader has synchronized this members configuration. Detailed Description Multi Chassis Management feature on CMC allows for pushing the lead chassis configuration data to its members.
Recommended Response Action Enable IPv6 for the specified server using the CMC command line or CMC Web GUI interface, so that the link to launch iDRAC is displayed on the CMC Web interface. For the command line options or navigation for Web interface, see the Troubleshooting section in the CMC Users Guide.
Arguments arg1 = slot number Detailed Description The NIC is disabled on the server identified in the message, and the CMC is unable to display the link to launch the iDRAC web interface. Recommended Response Action Enable the NIC on the server identified in the message using the CMC command line or CMC Web interface, so that the link to launch iDRAC is displayed on the CMC Web interface.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8506 Message A command to shut down the CMC was initiated. Detailed Description A command to shut down the CMC was initiated. Recommended Response Action No response action is required.
Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Trap/EventID 8691 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8508 Message Unable to synchronize the primary and secondary CMC removable flash media and the Extended Storage feature is not available.
CMC8509 Message Unable to activate the extended storage feature on the secondary CMC: arg1 . The feature will be deactivated. Arguments arg1 = cmc number Detailed Description The extended storage feature is not activated if the media on the secondary CMC is no longer functional. Recommended Response Action Do one of the following, and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration and verify if the card on the secondary CMC displays errors.
Severity Severity 1 (Critical) Trap/EventID 8689 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8511 Message Unable to synchronize the data in the Extended Storage removable flash media in the primary and secondary CMCs.
Detailed Description The Extended Storage feature is not activated if the removable flash media SD card on the secondary CMC does not respond within 90 seconds after activation is initiated. Recommended Response Action Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If errors are displayed, execute the following racadm command: "racadm cmcchangeover".
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8514 Message Fabric mismatch is detected in the I/O Module arg1 .
Detailed Description The I/O module may have taken more time to boot than was expected or the I/O module did not boot. Recommended Response Action Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and retry the operation. Otherwise, reinsert the I/O Module and retry the operation. If the problem persists, contact technical support.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8518 Message Detecting Double height server in slot arg1 but the iDRAC in bottom slot arg2 is also responding. Arguments arg1 = slot number, arg2 = slot number Detailed Description the Double height server identified in the message is detected in the top slot. However, the bottom slot is also responding which should not occur if a double height server is inserted.
Severity Severity 1 (Critical) Trap/EventID 2545 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8520 Message The FRU on server arg1 is not functioning. Arguments arg1 = slot number Detailed Description FRU on the server specified in the message is not functioning or CMC is unable to read it.
Detailed Description The Mezz card 1 FRU for the server specified in the message is not functioning or CMC is unable to read it. Recommended Response Action Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
CMC8523 Message The Mezz card 3 FRU for the server arg1 is not functioning. Arguments arg1 = slot number Detailed Description The Mezz card 3 FRU for the server specified in the message is not functioning or CMC is unable to read it. Recommended Response Action Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8525 Message The FRU on the sleeve arg1 is not functioning. Arguments arg1 = slot number Detailed Description The FRU on the sleeve specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service provider.
CMC8528 Message Unable to obtain or send link tuning or flex address data to server- arg1 . Arguments arg1 = slot number Detailed Description CMC is unable to obtain the link tuning or flex address information for the newly installed hardware (server, Input Output Module, or Mezzanine card), or is unable to send the link tuning or flex address information to iDRAC. Recommended Response Action Make sure that the currently installed CMC firmware is the latest.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8531 Message Unable to perform the requested action on the Sleeve or Sled arg1 because of insufficient user privileges.
Detailed Description The user account does not have sufficient privileges to perform the requested operation. Server Administrator privilege is required to perform the requested action. Recommended Response Action Use a different user account that has Server Administrator privilege, and retry the operation. For more information, contact your system administrator or service provider.
CMC8534 Message Unable to turn on the server arg1 because the power requirement request exceeds the power cap value. Arguments arg1 = slot number Detailed Description Unable to turn on the server specified in the message, because the available power is lesser than the requested power. Recommended Response Action In the CMC Web interface, verify the available power and server power requirements. If sufficient power is available, retry the operation. Otherwise, increase the power cap value.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8538 Message Firmware version string is too long. Detailed Description The length of the CMC firmware version to be sent in the message from local CMC to peer CMC is too long. Under these conditions, CMC version in the message is displayed as 1.0.
Recommended Response Action Do the following: 1) Save the Hardware Log if required. 2) Clear the Hardware Log. Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8540 Message The CMC arg1 is turned on.
Arguments arg1 = slot id Detailed Description The CMC specified in the message was reset by a watchdog event. Recommended Response Action No response action is required.
CMC8543 Message The CMC arg1 has reset because the thermal threshold was exceeded. Arguments arg1 = slot id Detailed Description The CMC specified in the message has reset because of thermal issues. Recommended Response Action Do the following: 1) Review the Hardware Log and check if there are fans that are not functioning properly. 2) Replace the fans that are not functioning properly. 3) If all the fans are functioning, check the chassis temperature in the CMC Web Interface or by using RACADM.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8546 Message Issues identified with Process arg1 . Failover condition detected. Arguments arg1 = process name Detailed Description A firmware error has occurred in the internal firmware process identified in the message. This condition will cause a CMC failover to occur.
Recommended Response Action No response action is required. If the issue persists, contact your service provider. Category Audit (CMC = Chassis Management Controller) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8548 Message The active Chassis Management Controller is no longer connected to an external network.
Arguments arg1 = health state Detailed Description If the chassis health status changes, new status is logged. The possible states are Invalid, Other, Unknown, Healthy, Non-critical, Critical, and Non-recoverable. Recommended Response Action No response action is required.
CMC8553 Message An internal error occurred and a failover condition is detected. Detailed Description An internal I2C hardware occurred and CMC initiated a failover to clear the hardware error. If the issue persists, contact your service provider.. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8555 Message An internal memory error has occurred and a failover condition is detected. Detailed Description An internal memory error occurred affecting the configuration database and CMC has initiated a failover . If the issue persists, contact your service provider. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8558 Message The system health is restored. Detailed Description The system health has recovered from a failover condition. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8562 Message The log is cleared. Detailed Description The hardware log is cleared. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit (CMC = Chassis Management Controller) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8564 Message The KVM mapping feature is disabled. Detailed Description The KVM is not mapped to any of the server slots.
Detailed Description The KVM mapping is enabled for the server slot specified in the message. The KVM cannot be mapped to this server slot. Recommended Response Action No response action is required.
CMC8567 Message The DVD drive is mapped to the server slot arg1 . Arguments arg1 = slot number Detailed Description The DVD drive is mapped to the server slot specified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8569 Message The server slot arg1 is enabled for DVD drive mapping. Arguments arg1 = slot number Detailed Description The server slot specified in the message is enabled for DVD drive mapping. The DVD drive can be mapped to this server slot. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8571 Message The coin cell battery in the primary CMC is not working. Detailed Description The coin cell battery in the primary CMC is not working. The battery needs to be replaced. Recommended Response Action Replace the coin cell battery in the primary CMC.
Category Audit (CMC = Chassis Management Controller) Severity Severity 1 (Critical) Trap/EventID 8689 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* CMC8573 Message The chassis health is arg1 . Arguments arg1 = health state Detailed Description The chassis health is critical or non-recoverable.
Filter Visibility iDRAC IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔* ✔* ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8576 Message The RAC CA Certificate is changed. Detailed Description The RAC CA Certificate is changed. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 8691 Filter Visibility iDRAC IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔* ✔* ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* CMC8578 Message The Remote Access Controller (RAC) SSL Certificate and key is changed Detailed Description The Remote Access Controller (RAC) SSL Certificate and key is changed.
Recommended Response Action Upload the certificate again and retry operation. Category Audit (CMC = Chassis Management Controller) Severity Severity 2 (Warning) Trap/EventID 8690 Filter Visibility iDRAC IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔* ✔* ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8601 Message The Chassis group arg1 is created.
CMC8602 Message The Chassis group arg1 is deleted. Arguments arg1 = group name Detailed Description The Chassis group identified in the message is deleted. This chassis was the leader of the group. Recommended Response Action No response action required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC8604 Message The FRU on storage sled arg1 is not functioning. Arguments arg1 = slot number Detailed Description The FRU on the storage sled specified in the message is not functioning or CMC is unable to read it. Recommended Response Action Do the following: 1) Reinsert the specified storage sled or virtual reseat the sled 2) Reset CMC and wait for a few minutes for the CMC to finish restarting.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* CMC8700 Message The I/O Module in slot arg1 is configured in secure IOM mode. Arguments arg1 = slot number Detailed Description I/O Module identified in the message cannot be managed from the CMC when the I/O Module is configured in secure IOM mode.
CPU Event Messages CPU0000 Message CPU arg1 has an internal error (IERR). Arguments arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU has a thermal trip. Check CPU heat sink OMSA Event ID 5604 OMSA Trap ID 5604 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0002 Message CPU arg1 has failed the built-in self-test (BIST).
CPU0003 Message CPU arg1 is stuck in POST. Arguments arg1 = number Detailed Description None Recommended Response Action 1) Turn off the server and disconnect input power for one minute. Re-apply input power and turn system on. 2) Reduce system configuration to minimum memory and remove all PCI devices. If system completes POST, update system BIOS. Reinstall memory and PCI one component at a time to meet the original configuration. 3) If the issue still persists, contact technical support.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0005 Message CPU arg1 configuration is unsupported. Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action Review product documentation for supported CPU configurations.
Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CPU0008 Message CPU arg1 is disabled. Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action if unexpected, check presence, and system setup (BIOS) configuration.
Severity Severity 3 (Informational) Trap/EventID 2243 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC CPU0010 Message CPU arg1 is throttled. Arguments arg1 = number Detailed Description The CPU is throttled due to thermal or power conditions. Recommended Response Action Review system logs for power or thermal exceptions.
CPU0011 Message Uncorrectable Machine Check Exception detected on CPU arg1 . Arguments arg1 = number Detailed Description None. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message Uncorrectable Machine Check Exception detected on CPU .
OMSA Trap ID iDRAC 5603 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0016 Message CPU arg1 is operating correctly. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (CPU = Processor) Severity Severity 3 (Informational) Trap/EventID 2243 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC CPU0024 Message CPU arg1 is enabled.
CPU0025 Message CPU arg1 terminator is absent. Arguments arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action Check presence and reinstall the terminator.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC CPU0701 Message CPU arg1 protocol error detected. Arguments arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions.
Recommended Response Action Check system and operating system logs for exceptions. If no exceptions found, remove input power, reinstall the processor, then apply input power. Category System Health (CPU = Processor) Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU bus parity error detected.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC CPU0704 Message CPU arg1 machine check error detected. Arguments arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute.
Category System Health (CPU = Processor) Severity Severity 3 (Informational) Trap/EventID 2243 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU0801 Message CPU arg1 voltage regulator module failed. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate.
CPU0802 Message A predictive failure detected on CPU arg1 voltage regulator module. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU0804 Message The power input for CPU arg1 voltage regulator module is outside of range. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute.
Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CPU0816 Message CPU arg1 voltage regulator module is absent. Arguments arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action if removal was unintended, check presence and re-install .
Trap/EventID Filter Visibility iDRAC 2243 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU0819 Message The power input for CPU arg1 voltage regulator module has been restored. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (CPU = Processor) Severity Severity 3 (Informational) Trap/EventID 2243 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CPU9000 Message An OEM diagnostic event occurred. Detailed Description None Recommended Response Action No response action is required.
CPUA Event Messages CPUA0023 Message CPU arg1 is absent Arguments arg1 = number Detailed Description None Recommended Response Action Verify processor installation. If present, reseat the processor. Category System Health (CPUA = Proc Absent) Severity Severity 1 (Critical) Trap/EventID 2457 LCD Message CPU is absent.
CTL Event Messages CTL1 Message Controller event log: arg1 Arguments arg1 = message Detailed Description This event is retrieved from the controller when iDRAC storage monitoring was not running. Such events which are generated in the past are logged as informational severity. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL100 Message The Patrol Read operation was stopped and did not complete for arg1 . Arguments arg1 = controller name Detailed Description The Patrol Read operation running on the controller was stopped by user request or an issue was detected by the controller.
Recommended Response Action No response action is required. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 Filter Visibility iDRAC IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔ LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL102 Message The arg1 is enabled.
CTL11 Message Configuration on arg1 was reset. Arguments arg1 = controller name Detailed Description A user operation to reset the controller configuration was performed. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75400 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL13 Message The arg1 cache has been discarded. Arguments arg1 = Controller name Detailed Description The controller has flushed the cache and all data in the cache has been lost.
CTL14 Message Single-bit ECC error limit exceeded on the arg1 DIMM. Arguments arg1 = controller name Detailed Description The storage controller memory identified in th emessage is not operating correctly. Recommended Response Action COntact your service provider.
OMSA Trap ID Filter Visibility 75100 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL17 Message arg1 arg2 is changed to arg3 . Arguments arg1 = Controller Name, arg2 = propertyname, arg3 = new value Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Re-issue the command. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2222 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL19 Message Abort CC on Error, Copyback, and Load Balance has changed for arg1 .
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL2 Message arg1 rebuild rate has changed. Arguments arg1 = Controller name Detailed Description You have changed the controller rebuild rate. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2224 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ CTL200 Message The current firmware version arg1 is older than the required version arg2 for arg3 .
CTL201 Message The current driver version arg1 ( arg2 ) is older than the required driver version arg3 ( arg4 ) for arg5 . Arguments arg1 = major verion number, arg2 = minor version number, arg3 = major version number, arg4 = minor version number, arg5 = controller name Detailed Description The controller driver for the identified controller is not a supported version.
OMSA Event ID 2165 OMSA Trap ID 75300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL203 Message Abort Check Consistency on Error, Copyback or Auto Copyback on Predictive Failure, and Load Balance values are changed for arg1 .
Arguments arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes. Recommended Response Action No response action is required.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL206 Message Abort Check Consistency on Error and Auto Copyback on Predictive Failure values are changed for arg1 . Arguments arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) OMSA Event ID 2372 OMSA Trap ID 75100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL208 Message Unable to authenticate the entered passphrase for the arg1 . Arguments arg1 = controller name Detailed Description Unable to authenticate the entered passphrase.
CTL209 Message Enabled persistent hot spare on arg1 . Arguments arg1 = controller name Detailed Description The persistent hot spare feature is enabled on the controller identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ CTL210 Message Disabled persistent hot spare on arg1 . Arguments arg1 = controller name Detailed Description The persistent hot spare feature is disabled on the controller identified in the message. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) OMSA Event ID 2398 OMSA Trap ID 75100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL212 Message The existing encryption key in the arg1 is deleted.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL213 Message The Local Key Management (LKM) is enabled on arg1 . Arguments arg1 = controller name Detailed Description The Local Key Management (LKM) security mode is enabled on the controller identified in the message. Recommended Response Action No response action is required.
OMSA Event ID 2411 OMSA Trap ID 75100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL215 Message Redundant path disconnected on arg1 . Arguments arg1 = Controller Name Detailed Description The controller identified in the message has two connectors that are connected to the same enclosure.
CTL216 Message Redundant path connection is restored on arg1 . Arguments arg1 = Controller Name Detailed Description The communication in the redundant path on the connectors of the controller identified in the message is restored. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC CTL22 Message Load Balance has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL25 Message Auto Copyback on Predictive Failure has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2231 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL27 Message The arg1 alarm is silenced. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
CTL28 Message The Background Initialization (BGI) rate has changed for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL3 Message arg1 alarm is enabled. Arguments arg1 = Controller name Detailed Description You have enabled the controller alarm. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL32 Message Abort CC on Error is modified for arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL35 Message A foreign configuration was imported on arg1 . Arguments arg1 = controller name Detailed Description The operation to import foreign configuration (virtual disks, host spares, and so on) completed successfully. Recommended Response Action Verify the foreign configuration was successfully imported by viewing the virtual disks and hot spares.
Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2241 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL37 Message A Patrol Read operation started for arg1 . Arguments arg1 = controller name Detailed Description A patrol read operation was initiated by the controller or the user.
CTL38 Message The Patrol Read operation completed for arg1 . Arguments arg1 = controller name Detailed Description The patrol read task ended. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL4 Message arg1 alarm is disabled. Arguments arg1 = Controller name Detailed Description You have disabled the controller alarm. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = Controller name Detailed Description An error involving multiple bits has been encountered during a read or write operation. The error correction algorithm recalculates parity data during read and write operations. If an error involves only a single bit, it may be possible for the error correction algorithm to correct the error and maintain parity data. An error involving multiple bits, however, generally indicates data loss.
OMSA Trap ID Filter Visibility 75300 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL42 Message Enclosure Management Module (EMM) hot plug is not supported on arg1 . Arguments arg1 = Controller name Detailed Description An attempt to hot plug an Enclosure Management Module (EMM) has been detected.
Arguments arg1 = args, arg2 = Controller name Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the utility that ran the diagnostics and can vary depending on the situation. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL45 Message Single-bit ECC error on arg1 . Arguments arg1 = Controller name Detailed Description The Dual In-line Memory Module (DIMM) is beginning to malfunction.
Detailed Description The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur.. Recommended Response Action Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. Refer to the storage hardware documentation for information on replacing the DIMM.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ CTL48 Message A foreign configuration was detected on arg1 . Arguments arg1 = controller name Detailed Description The controller has physical disks that were moved from another controller or have been removed and replaced on the current configuration. These physical disks contain virtual disks that were created on the current or other controller.
Recommended Response Action No response action is required as the controller is taking the required corrective action. However, If this message is generated often (such as during each reboot), then replace the controller.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL50 Message The arg1 NVRAM has corrupt data. Arguments arg1 = Controller name Detailed Description The NVRAM has corrupt data. The controller is unable to correct the situation. Recommended Response Action Replace the controller.
Severity Severity 2 (Warning) Trap/EventID 4330 OMSA Event ID 2329 OMSA Trap ID 75300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL52 Message arg1 SAS port report: arg2 Arguments arg1 = Controller name, arg2 = args Detailed Description This alert is provided for informational purposes.
CTL53 Message A controller hot plug has been detected. Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL55 Message arg1 event log: arg2 Arguments arg1 = Controller name, arg2 = args Detailed Description The text for this alert is generated by the controller and can vary depending on the situation.
Arguments arg1 = Controller name, arg2 = args Detailed Description The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running. Recommended Response Action See the hardware documentation for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL58 Message arg1 SAS SMP communications error arg2 Arguments arg1 = Controller name, arg2 = args Detailed Description The text for this alert is generated by the firmware and can vary depending on the situation.
Arguments arg1 = Controller name, arg2 = args Detailed Description There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health sub-tab displays a red X or yellow exclamation point for enclosure components that are failed or degraded. See the enclosure documentation for more information. Recommended Response Action There may be a problem with the enclosure.
OMSA Trap ID Filter Visibility 75300 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL60 Message A user has discarded data from the arg1 cache. Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = Controller name Detailed Description The controller has detected a change in the storage configuration between since its last shut down. This can generally happen if some configured physical disks are removed from the system when the system was shutdown. Recommended Response Action Shut down the system. Re-insert the removed physical disks and re-start the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL63 Message Previous configuration was found completely missing during boot time on arg1 . Arguments arg1 = Controller name Detailed Description The controller is unable to retrieve storage configuration saved during last shut down.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL66 Message Attempted to import Unsupported Virtual Disk type RAID arg1 on arg2 . Arguments arg1 = args, arg2 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 4331 OMSA Event ID 2374 OMSA Trap ID 75100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL68 Message Attempted to import Virtual Disk with missing Physical Disk on arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes.
CTL69 Message Attempted to import virtual disk with outdated physical disk information on arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 75300 IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL70 Message Attempted to import an orphan drive on arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL73 Message Foreign configuration is imported only partially. Some configurations failed to import on arg1 . Arguments arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description The controller has preserved data in the cache from a virtual disk, which it can no longer locate. No data loss has occurred as the controller is saving these operations in its cache. Recommended Response Action Check for the existence of a foreign configuration and import if any. Check that enclosures are cabled correctly.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ CTL76 Message A configuration command could not be committed to disk on arg1 Arguments arg1 = Controller name Detailed Description The controller encountered errors while applying the configuration on the physical disks. The configuration command applied has not taken effect.
Detailed Description This alert message occurs if controller firmware is flashed successfully. Recommended Response Action No response action is required.
CTL79 Message Controller in arg1 is not supported and will not be powered on. Arguments arg1 = controller slot Detailed Description This controller does not support features required for this chassis. This controller will not be powered on to prevent data loss. Recommended Response Action Replace the controller with a supported controller.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ CTL80 Message arg1 experienced the following warning during startup: arg2 . Arguments arg1 = controller name, arg2 = controller message Detailed Description The controller identified in the message has an issue as displayed in the message.
Recommended Response Action No response action is required. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CTL82 Message arg1 is functioning normally.
CTL83 Message Communication with arg1 has been lost. Arguments arg1 = controller name Detailed Description The management controller is not communicating with the storage controller identified in the message. This may be because of any one of the following: a) PCIe subsystem is has stopped functioning b) An issue in the storage controller c) An issue in the management controller. Recommended Response Action Restart the server. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC Remote System Log WS Eventing ✔ ✔ LC Log iDRAC ✔* CMC ✔ LCD ✔* ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL85 Message arg1 is operating at less than optimal bandwidth. Arguments arg1 = controller name Detailed Description The controller identified in the message experienced a PCIe training error and is operating at less than full bandwith.
Recommended Response Action No response action is required. Category Storage (CTL = Storage Contr) Severity Severity 3 (Informational) Trap/EventID 4331 Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔ IPMI Alert LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL87 Message arg1 settings do not match the settings of its peer.
CTL88 Message arg1 firmware does not match the firmware of its peer controller. Arguments arg1 = controller name Detailed Description The firmware running on the controller identified in the message does not match the firmware version of its peer controller. This can cause issues in a fault tolerant setup. Recommended Response Action Make sure each controller is using the same firmware by updating the firmware of the identified controller.
Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔ IPMI Alert LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle Reset ✔* Chassis Event Proxy ✔ CTL9 Message Bad block extended medium error on arg1 . Arguments arg1 = Controller name Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Detailed Description The peer controller is not compatible with the contoller identified in the message because of a hardware mismatch. Recommended Response Action Replace the peer controller with the same model controller as the controller identified in the message.
CTL92 Message arg1 is not operating in Fault Tolerant Mode because of an incompatible license setting on its peer controller. Arguments arg1 = controller name Detailed Description The controller identified in the message licensed features do not match its peer. Recommended Response Action Update the license on the peer controller.
Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔ IPMI Alert LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔ CTL94 Message arg1 has been successfully changed to operate in single controller mode. Arguments arg1 = controller name Detailed Description The controller identified in the message has been changed to operate as a single controller and not as part of a fault tolerant pair.
Recommended Response Action This situation may resolve itself in a few minutes. If the situation does not resolve itself or this message is repeated, contact your service provider.
CTL97 Message arg1 personality changed to arg2 mode. Arguments arg1 = controller name, arg2 = new mode Detailed Description The controller identified in the message has been changed to a new personality mode (HBA or RAID). Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC CTL99 Message Security key assigned to arg1 is deleted. Arguments arg1 = controller name Detailed Description The security key assigned to the controller identified in the message is deleted. Recommended Response Action No response action is required.
DH Event Messages DH001 Message Resource needed to perform the operation is unavailable. Detailed Description Resource temporarily unavailable Recommended Response Action Try again. If the error persists, use RACADM command racreset to clear the issue. Category Configuration (DH = Cert Mgmt) Severity Severity 2 (Warning) No alerts are applicable for this message DH002 Message Internal I/O failure Detailed Description Internal I/O failure Recommended Response Action Try again.
DH004 Message iDRAC does not have sufficient free resources to generate keys Detailed Description Error generation Keys Recommended Response Action Boot the OS. If the error persists, contact technical support. Category Configuration (DH = Cert Mgmt) Severity Severity 1 (Critical) No alerts are applicable for this message DH005 Message CA Cert is corrupted, expired, or does not have signing privileges.
DH007 Message The password unlocked the private key but it was the wrong private key. Detailed Description CA priv key/CA Cert mismatch Recommended Response Action Check that the private key parameter is correct. The passphrase can be validated against the private key, passphrase, and certificate can be validated using OpenSSL tools.
DH010 Message Reset iDRAC to apply new certificate. Until iDRAC is reset, the old certificate will be active. Detailed Description The iDRAC must be reset to apply a new certificate. Until the iDRAC has reset, the old certificate will be active. Recommended Response Action Reset the iDRAC. The iDRAC can be reset by pressing the Identify button for 15 seconds.
DIAG Event Messages DIAG 0414 Message Cables - arg1 not detected. Arguments arg1 = Inverter Name Detailed Description Recommended Response Action Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0000 Message Pass Detailed Description All Tests passed Recommended Response Action OK, life is good.
Arguments arg1 = Cpu Number, arg2 = Exception Type Detailed Description Recommended Response Action Issue is on system board. Recommend flash the latest BIOS and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0112 Message CPU arg1 - Machine check exception detected. Arguments arg1 = Cpu Number Detailed Description Recommended Response Action Issue is on system board.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0115 Message CPU Stress Thermal condition. Limit arg1 C, Actual arg2 C. Arguments arg1 = Degrees, arg2 = Degrees Detailed Description Recommended Response Action Check fans. Check for obstructed air vents. Check for excessive amounts of dust.
Severity Severity 3 (Informational) No alerts are applicable for this message DIAG0122 Message Memory errors detected. Limit exceeded. Additional errors will not be resolved. Detailed Description Recommended Response Action MemRx is enabled and detected too many errors for safe resolution. Recommend DIMM replacement. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0123 Message UEFI: Memory error detected.
Arguments arg1 = Timestamp, arg2 = Log message Detailed Description Log message is different for the log type supported by the system. An IPMI log may refer to "SEL", other log types also exist. Recommended Response Action Depends on .
DIAG0126 Message The event log(s) must be cleared before testing can continue. Detailed Description Recommended Response Action Clear the log, reboot, and retest. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0131 Message Battery - The battery is not installed.
Recommended Response Action Replace the battery. Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0133 Message Battery - The battery cannot provide sufficient power. Detailed Description Recommended Response Action Check battery contacts, plugs and cables. May need to replace battery.
DIAG0142 Message Hard Drive arg1 - S/N arg2 , arg3 self test unsuccessful arg4 . Arguments arg1 = Drive Location, arg2 = Serial Number, arg3 = DST Short, DST Long, arg4 = Error Reason Detailed Description Recommended Response Action If is "terminated" then the disk controller terminated the test so a retry of the test is advisable.Otherwise the hard drive should be replaced. {In the factory, this test type may also be DEFT, in addition to DST Short and DST Long.
DIAG0144 Message Hard Drive arg1 - self test not supported. Arguments arg1 = Drive Location Detailed Description Mainly seen with very old hard drives Recommended Response Action Category Storage (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0145 Message Hard Drive arg1 - S/N arg2 , self test did not complete.
Detailed Description Prior failure checking removed, is now obsolete. Recommended Response Action Category Storage (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG0147 Message Optical Drive arg1 - Self test: arg2 . Arguments arg1 = Nth Drive, arg2 = Error Reason Detailed Description Recommended Response Action This typically is a user error since these drives can be disconnected from the system.
Recommended Response Action Category Storage (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0149 Message Optical Drive - no drive detected. Detailed Description Recommended Response Action Category Storage (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG0150 Message Hard Drive - No Hard Drive detected, or disk controller not supported.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0151 Message Hard Drive arg1 - S/N arg2 , incorrect status = arg3 \n arg4 . Arguments arg1 = Drive Location, arg2 = Serial Number, arg3 = 80000000000000??, arg4 = Error Reason Detailed Description Recommended Response Action SMART Predictive Failure indicates the hard drive has failed SMART and maybe nearing the end of its life.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0154 Message Tape Drive arg1 - S/N arg2 , incorrect status = arg3 \n arg4 .
Recommended Response Action Power down system and check the signal and power connections to the hard drive. Rerun the diagnostic.If no error occurs then it was a cable or connector issue. This error is issued for notebooks which must have a hard disk so it is an error if not found. Category Storage (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0212 Message System board - CMOS, Location = arg1 h, Expected = arg2 h, Found = arg3 h.
Recommended Response Action Make sure the BIOS is current and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0232 Message RTC - did not generate periodic ticks. Detailed Description Recommended Response Action Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0233 Message System board - RTC seconds count is not updating.
Recommended Response Action Make sure the BIOS is current and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0235 Message PM timer 1 had wrong time period. Expected arg1 , Actual arg2 .
Recommended Response Action Make sure the BIOS is current and retry the diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0243 Message USB controller error. Detailed Description Recommended Response Action Ensure that USB ports are intact, contain no failed device and that BIOS is current. After corrective action, rerun the diagnostics.
Recommended Response Action Ensure that the USB device is correctly inserted or try another USB port and/or to see if it is just a particular device or port. After corrective action, rerun the diagnostics. If the problem persists, ensure that BIOS is current. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0251 Message Event log - The log contains failing records.
DIAG0314 Message Thermal: The ( arg1 ) reading ( arg2 C) exceeds the thermal limit. Arguments arg1 = Sensor Name, arg2 = Degrees Detailed Description Recommended Response Action Check the event log for thermal events, including defective fans and defective sensors. Inspect the system for clogged or obstructed air vents. Make sure that the BIOS is current and rerun the diagnostics.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0321 Message LCD EDID - Unable to access EDID EEPROM. Detailed Description Recommended Response Action This could relate to the LCD connector and cables. Otherwise, flash the latest BIOS and retry diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0322 Message LCD panel - Unable to modify brightness.
No alerts are applicable for this message DIAG0324 Message LCD panel - User reported LCD BIST colors were not displayed. Detailed Description Recommended Response Action Possible user error, make sure that the BIOS is current and retry diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG0325 Message LCD panel - User provided no input for LCD BIST.
DIAG0327 Message LCD panel - Unable to use BIOS interface. Detailed Description Recommended Response Action Make sure that the BIOS is current and retry diagnostics. Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) No alerts are applicable for this message DIAG0328 Message LCD panel - Unable to detect variance in ambient light sensor. Detailed Description Recommended Response Action Make sure that the BIOS is current and retry diagnostics.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0332 Message Video memory - Video memory integrity test discrepancy. Detailed Description Recommended Response Action Make sure that the BIOS is current and retry diagnostics.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0334 Message Video - User reported the patterns were not displayed. Detailed Description Recommended Response Action Possible user error. Otherwise, make sure that BIOS is current and retry diagnostics.
DIAG0412 Message Cables - arg1 not detected. Arguments arg1 = AUX LCD Name Detailed Description Recommended Response Action Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) No alerts are applicable for this message DIAG0413 Message Cables - arg1 not detected.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0511 Message Fan - The ( arg1 ) fan failed to respond correctly. Arguments arg1 = Name Detailed Description Recommended Response Action The fan may be faulty, check for obstructions to the fan and vents. Make sure that BIOS is current and retry the diagnostics.
Category System Health (DIAG = Diagnostic) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG0620 Message Network arg1 - arg2 Arguments arg1 = Number, arg2 = Failure Message Detailed Description UEFI Driver provides a DIAGNOSTIC protocol and this protocol supplies a test that failed.
Arguments arg1 = Number, arg2 = Hex, arg3 = Hex, arg4 = EFI Driver Name Detailed Description Test only warns because UEFI Network Driver is old and has known false failures. Recommended Response Action Update Network firmware.
Recommended Response Action Should not occur Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8003 Message Fan - Unable to set Manufacturing Mode.
Detailed Description Recommended Response Action Should not occur Category System Health (DIAG = Diagnostic) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8005 Message LCD BIST not supported. or Fan - Fan speed failure. Expected at least arg1 , observed arg2 .
DIAG8006 Message Fan - Unable to set fans to arg1 speed.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8008 Message Out of memory! fMalloc() Failed! :OR: Unable to allocate memory for object data. :OR: Unable to arg1 testable memory. :OR: Unable to start application processor(s) :OR: Unable to stop all APs. The system may be unstable and should be rebooted. Arguments arg1 = Name Detailed Description Recommended Response Action Software error, should not normally occur in field.
No alerts are applicable for this message DIAG800B Message Retrieve vendor ID function error. Detailed Description Recommended Response Action Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG800C Message Get/Set inverter mode function error. Vendor: arg1 Revision: arg2 .
No alerts are applicable for this message DIAG800E Message Set lamp on function error. Vendor: arg1 Revision: arg2 . Arguments arg1 = Name, arg2 = Decimal Detailed Description Recommended Response Action Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG800F Message Restore function error. Vendor: arg1 Revision: arg2 .
No alerts are applicable for this message DIAG8011 Message Invalid status return from the device. Detailed Description Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8012 Message Invalid parameter passed to the device.; Unknown test ( arg1 ) selected.
No alerts are applicable for this message DIAG8014 Message ADDF module ( arg1 ) device ( arg2 ) failed with error code arg3 , number arg4 . No EPSA beep code mapped. Arguments arg1 = Name, arg2 = Name, arg3 = Hex, arg4 = hex Detailed Description Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8015 Message Unable to stop all APs.
Detailed Description Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8017 Message Battery - BIOS has no support for battery health. Detailed Description Recommended Response Action Software error, should not normally occur in field.
Recommended Response Action Software error, should not normally occur in field. Category System Health (DIAG = Diagnostic) Severity Severity 3 (Informational) No alerts are applicable for this message DIAG8020 Message Low memory. arg1 k bytes free! Arguments arg1 = Decimal Detailed Description Recommended Response Action Software error, should not normally occur in field.
Detailed Description Each generation of ULTRIUM Tape drives usually supports the previous generation but not newer generation tape media. Recommended Response Action Install the correct tape media.
DIAG8156 Message Tape Drive arg1 - S/N arg2 , no media, cannot test drive. Arguments arg1 = Drive Location, arg2 = Serial Number Detailed Description Testing requires scratch tape media. Recommended Response Action Install tape media or skip test.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8158 Message arg1 Drive arg2 - S/N arg3 , incorrect status = arg4 \n arg5 . Arguments arg1 = Backplane|Expander|RD1000, arg2 = Drive Location, arg3 = Serial Number, arg4 = 80000000000000??, arg5 = Error Reason Detailed Description A device failed a command and testing cannot complete. Recommended Response Action Retry test. If failure persists and BIOS is up to date, a hardware problem is indicated.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIAG8166 Message OS - Suspect corrupt MBR, verify MBR with Anti-Virus Application. Detailed Description Recommended Response Action Run virus scan.
Recommended Response Action Reseat the PCI-Express adapter described and retest.
DIAG8611 Message User reported not hearing speaker tone Detailed Description Recommended Response Action If the beep was not heard, verify the internal speakers are connected properly. On some systems, internal speakers are a purchased option. For a given system, if the speaker is optional, it might not exist on that system. If audio is not heard, make sure to unplug anything plugged into an external headphone jack and rerun the test.
DIS Event Messages DIS001 Message Auto Discovery feature not licensed. Detailed Description Auto Discovery starts automatically, but was unable to find a valid license. Once you have obtained a valid license and installed it, restart. Recommended Response Action Follow service providers instructions to enable the license.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS003 Message Auto Discovery process started. Detailed Description Auto Discovery process will try to connect to a Provisioning Server over the next 24 hours. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS005 Message Auto Discovery communicated successfully with Provisioning Server arg1 . Arguments arg1 = provisioning server name Detailed Description Message was sent successfully from Auto Discovery to Provisioning Server to request certificate. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS007 Message Unable to notify Provisioning Server of iDRAC IP address change. Detailed Description Unable to connect to Provisioning Server to notify about new iDRAC IP . Recommended Response Action Check Provisioning Server connectivity and retry..
Recommended Response Action No response action is required. Category Configuration (DIS = Auto-Discovery) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS009 Message Notification of iDRAC IP address changed to arg1 sent to Provisioning Server.
Arguments arg1 = progress message Detailed Description The Auto Discovery process has encountered a problem.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS012 Message Auto Discovery client using factory signed client certificate. Detailed Description Factory signed client certificate is being used. Auto Discovery client is using this certificate for the SSL connection with the Provisioning Server. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DIS014 Message Auto Discovery client using customer provided CA certificate to authenticate Provisioning Server. Detailed Description Auto Discovery client is using the customer provided Certificate Authority certificate to authenticate the Provisioning Server for the SSL connection. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC DIS016 Message Response received from Provisioning Server to the notification of iDRAC IP address change. Detailed Description Provisioning Server responded to iDRAC IP address change. Recommended Response Action No response action is required.
Category Configuration (DIS = Auto-Discovery) Severity Severity 3 (Informational) Trap/EventID 10635 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIS101 Message The execution of AutoConfig operation is started.
Detailed Description The AutoConfig configuration import operation could not be started, because the AutoConfig .xml file is not available in the sharename or location specified in the DHCP scope option field where the VendorID=iDRAC. Recommended Response Action Update the sharename or location in the DHCP scope option field where the VendorID=iDRAC, make sure the AutoConfig import file is available, and then retry the operation.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIS104 Message The AutoConfig operation is unable to access the network share folder, because an invalid filename is specified in the DHCP scope option field where the VendorID=iDRAC. Detailed Description The AutoConfig operation is unable to access the network share folder, because an invalid filename is specified in the DHCP scope option field where the VendorID=iDRAC.
Severity Severity 3 (Informational) Trap/EventID 10635 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIS106 Message Unable to start the AutoConfig file import operation, because an invalid shutdown type was specified in the DHCP scope option field where the VendorID=iDRAC.
Detailed Description Unable to start the AutoConfig file import operation, because an invalid AutoConfig time-to-wait value is specified in the DHCP scope option field where the VendorID=iDRAC. Recommended Response Action In the DHCP scope option field where VendorID=iDRAC, enter a time-to-wait (-t) value more than 300 seconds and less than 3600 seconds and then retry the operation.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC DIS109 Message Unable to start the AutoConfig file import operation, because an invalid End Host Power State value is specified in the DHCP scope option field where the VendorID=iDRAC. Detailed Description The server could not be configured because the End Host Power State value specified in the DHCP scope option field where the VendorID=iDRAC is incorrect.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC 477
DKM Event Messages DKM1000 Message A network problem detected. Cannot contact key management server. Detailed Description None Recommended Response Action Check for network connectivity. Review network, server, and client configuration.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DKM1002 Message Key management server certificate problem detected.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC DKM1006 Message Key management server error detected. Detailed Description None Recommended Response Action Review server error logs for additional information. Category System Health (DKM = Dell Key Mngr) Severity Severity 1 (Critical) LCD Message Key management server error.
ECM Event Messages 481
ENC Event Messages ENC1 Message arg1 was inserted. Arguments arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed is inserted into the enclosure. Recommended Response Action No response action is required.
Trap/EventID 4339 OMSA Event ID 2152 OMSA Trap ID 85100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ ENC100 Message arg1 is sending inconsistent reponses to the controller.
ENC11 Message The arg1 service tag was changed. Arguments arg1 = enclosure name Detailed Description An enclosure service tag was changed. In most circumstances, this service tag should only be changed by the service provider. Recommended Response Action Make sure that the service tag was changed under authorized circumstances.
OMSA Trap ID Filter Visibility 85100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC13 Message Unsupported configuration detected on arg1 . arg2 arg3 Arguments arg1 = Enclosure Name, arg2 = EMM0 1, arg3 = EMM1 2 Detailed Description An unsupported configuration was detected.
Arguments arg1 = controller name Detailed Description There are too many enclosures attached to the controller port. When the enclosure limit is exceeded, the controller loses contact with all enclosures attached to the port. This is an unsupported configuration. Recommended Response Action Remove the extra enclosures. Refer to the storage hardware documentation for maximum number of enclosures that can be connected.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ ENC16 Message An enclosure blink has ceased on arg1 . Arguments arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔ ENC19 Message arg1 has failed. Arguments arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of power to the EMM. The EMM self-test may also have identified a failure. There may also be a firmware problem or a multi-bit error. Recommended Response Action Reseat the Enclosure Management Module (EMM).
Category Storage (ENC = Storage Enclosr) Severity Severity 1 (Critical) Trap/EventID 4337 OMSA Event ID 2297 OMSA Trap ID 95400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC21 Message arg1 has been removed.
ENC22 Message The arg1 has a bad sensor arg2 . Arguments arg1 = Enclosure Name, arg2 = args Detailed Description The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. Recommended Response Action Refer to the storage hardware documentation for more information.
OMSA Trap ID Filter Visibility 85400 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC24 Message Communication with arg1 is intermittent. Arguments arg1 = enclosure name Detailed Description The controller is not receiving a consistent response from the enclosure. There could be a firmware problem or an invalid cabling configuration.
ENC25 Message arg1 has a hardware error. Arguments arg1 = enclosure name Detailed Description The enclosure or an enclosure component is in a Failed or Degraded state. Recommended Response Action Verify the health of the enclosure and its components. See the storage hardware documentation for more information. Contact technical support.
OMSA Event ID 2302 OMSA Trap ID 85400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC27 Message SAS or SATA mixing of physical disks is not supported within the arg1 . Arguments arg1 = Enclosure Name Detailed Description The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled.
ENC28 Message Enclosure Management Module (EMM) firmware version mismatch detected in arg1 . arg2 arg3 . Arguments arg1 = enclosure name, arg2 = EMM 0 version, arg3 = EMM 1 version Detailed Description The firmware on the EMM modules is not the same version. Both modules must have the same firmware version. This message is caused when you attempt to insert an EMM module that has a different firmware version than an existing module.
Trap/EventID 4339 OMSA Event ID 2353 OMSA Trap ID 105100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC3 Message arg1 is shutdown. Arguments arg1 = Enclosure Name Detailed Description The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range.
ENC30 Message arg1 firmware download is in-progress. Arguments arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Event ID 2355 OMSA Trap ID 85300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ ENC32 Message Storage Enclosure Processor (SEP) for arg1 has been rebooted.
ENC33 Message Redundancy on arg1 is normal. Arguments arg1 = Enclosure Name Detailed Description Data redundancy has been restored to an enclosure that previously suffered a loss of redundancy. Recommended Response Action This alert is provided for informational purposes.
OMSA Event ID 2120 OMSA Trap ID 85300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* ✔ ENC40 Message A new enclosure was detected on arg1 . Arguments arg1 = controller name Detailed Description The controller detected a new enclosure. This is due either to a hot plug of an enclosure, or a power state change of an enclosure.
ENC5 Message Redundancy on arg1 is degraded Arguments arg1 = Enclosure Name Detailed Description One or more of the enclosure components has failed. For example, a fan or power supply may have failed. Although the enclosure is currently operational, the failure of additional components could cause the enclosure to fail. Recommended Response Action Identify and replace the failed component. To identify the failed component, select the enclosure in the tree view and click the Health subtab.
Recommended Response Action Check for problems with the cables. See the Cables attached correctly section for more information on checking the cables. You should also check to see if the enclosure has degraded or failed components. To do this, select the enclosure object in the tree view and click the Health subtab. The Health subtab displays the status of the enclosure components.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset ✔* Chassis Event Proxy ✔ ENC8 Message The arg1 alarm was disabled. Arguments arg1 = Enclosure Name Detailed Description You have disabled the enclosure alarm. Recommended Response Action No response action is required.
Detailed Description You have changed the enclosure asset tag. This alert is provided for informational purposes. Recommended Response Action No response action is required.
EPP Event Messages 505
FAN Event Messages FAN0000 Message Fan arg1 RPM is less than the lower warning threshold. Arguments arg1 = number Detailed Description The fan is not performing optimally. The fan may be installed improperly or may be failing. Recommended Response Action Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy FAN0002 Message Fan arg1 RPM is greater than the upper warning threshold. Arguments arg1 = number Detailed Description The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (FAN = Fan Event) Severity Severity 1 (Critical) Trap/EventID 2153 LCD Message Fan RPM is outside of range. Check fan.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy FAN0005 Message Fan arg1 RPM is within range. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ FAN0007 Message Fan arg1 was inserted. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (FAN = Fan Event) Severity Severity 3 (Informational) Trap/EventID 2155 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* FAN0009 Message Fan arg1 is absent.
FAN0010 Message Fan arg1 is disabled. Arguments arg1 = number Detailed Description The fan may be required for optimal performance. Recommended Response Action No response action is required. Category System Health (FAN = Fan Event) Severity Severity 2 (Warning) Trap/EventID 2154 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* ✔ CMC FAN0011 Message Fan arg1 is enabled.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC FAN0012 Message arg1 RPM is less than the lower warning threshold. Arguments arg1 = fan name Detailed Description The device is not performing optimally. The device may be installed improperly. Recommended Response Action Remove and re-install the device at the next scheduled service.
Recommended Response Action Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
FAN0015 Message arg1 RPM is greater than the upper critical threshold. Arguments arg1 = fan name Detailed Description The cooling device is not performing optimally. The cooling device may be installed improperly. Recommended Response Action Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* FAN0017 Message arg1 RPM is within normal operating range. Arguments arg1 = fan name Detailed Description The RPM of the fan identified in the message is functioning correctly. Recommended Response Action No response action is required.
Recommended Response Action Replace the fan identified in the message with another fan which supports Enhanced Cooling Mode. Category System Health (FAN = Fan Event) Severity Severity 2 (Warning) No alerts are applicable for this message FAN0019 Message An incompatibility between operating mode and fan type was corrected for fan arg1 . Arguments arg1 = fan number Detailed Description An incompatibility between operating mode and fan type was corrected for the fan identified in the message.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC FAN0021 Message arg1 is offline. Arguments arg1 = fan name Detailed Description The fan identified in the meesage is removed. However, the fan may be required for optimal system performance. Recommended Response Action Re-install the fan, and open the OMSA Web interface to verify if the fan identified in the message is displayed correctly. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC FAN0023 Message Unable to read the arg1 sensor value. Arguments arg1 = sensor name Detailed Description The fan sensor identified in the message has failed or the fan has failed.
Recommended Response Action No response action is required. Category System Health (FAN = Fan Event) Severity Severity 3 (Informational) OMSA Event ID 5102 OMSA Trap ID 5102 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC FAN0025 Message The arg1 sensor state has changed to a warning state with a value of arg2 RPM.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC FAN0026 Message The arg1 sensor detected an error with a value of arg2 RPM. Arguments arg1 = sensor name, arg2 = fan speed Detailed Description The fan sensor identified in the message indicates that the related fan has exceeded critical RPM thresholds.. Recommended Response Action Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider.
OMSA Event ID 5105 OMSA Trap ID 5105 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC FAN1000 Message arg1 was removed. Arguments arg1 = Fan Sensor Name Detailed Description The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition.. Recommended Response Action Re-insert the fan into the enclosure.
Detailed Description The enclosure detected that a fan was inserted. Recommended Response Action No response action is required. Category Storage (FAN = Fan Event) Severity Severity 3 (Informational) Trap/EventID 4203 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* FAN1002 Message arg1 has failed.
FAN8500 Message Enhanced Cooling Mode is Enabled Detailed Description Enabling Enhanced Cooling Mode will provide increased airflow capability to the blades by increasing the maximum allowable blower speed at the cost of increased power consumption. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN8503 Message The Chassis was turned off because more than two internal fans stopped functioning. Detailed Description The Chassis was turned off because more than two Chassis internal fans stopped functioning. The fans with issues are identified in the CMC Hardware (System Event Log) and Chassis Logs.
Recommended Response Action No response action required. Category Configuration (FAN = Fan Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN901 Message The Enhanced Cooling Mode is successfully disabled. Detailed Description The Enhanced Cooling Mode is successfully disabled.
Detailed Description The Enhanced Cooling Mode cannot be set because required power is not available. Recommended Response Action Add PSUs with higher power capability or remove Chassis components such as I/O Modules orservers until the power requirements have been lowered enough to emable the Enhanced Cooling Mode, and then retry the operation.
FAN904 Message Cannot enable the Enhanced Cooling Mode because the Maximum Power Conservation Mode is enabled. Detailed Description The Enhanced Cooling Mode cannot be enabled because the Maximum Power Conservation Mode is enabled. Recommended Response Action Disable the Maximum Power Conservation Mode, and then retry the operation. To disable the mode by using CMC Web interface, click Chassis Overview > Power > Configuration.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN906 Message Changes are not made to the current settings. Detailed Description Changes are not made to the current settings. Recommended Response Action Make sure that changes are made to the settings and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FAN908 Message The Enhanced Cooling Mode feature is already disabled. Detailed Description The Enhanced Cooling Mode feature is already disabled. Recommended Response Action No response action required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC 531
FC Event Messages FC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration (FC = Fiber Channel) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FC002 Message Unable to allocate memory.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC FC003 Message Missing required parameter. Detailed Description An invalid number of arguments was provided to the method. Recommended Response Action Enter required input parameters and retry. For more information, see Lifecycle Controller Users Guide or the FC HBA Profile specification.
FC005 Message The number of AttributeName array elements does not match the AttributeValue array element count. Detailed Description The number of AttributeName and AttributeValue array elements are not equal. Recommended Response Action Provide equal number of array elements for AttributeName and AttributeValue parameters. For more information about input parameters, see FC HBA Profile specification.
FC008 Message No pending data present to create a Configuration job. Detailed Description No changes are available between the previous configuration and the current configuration. To create a Configuration job, change at least one attribute. Recommended Response Action Change the configuration of one or more attributes and retry creating the Configuration job.
Severity Severity 2 (Warning) No alerts are applicable for this message FC011 Message Configuration job already created, pending data cannot be deleted Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job is completed. Recommended Response Action Cancel the configuration job or wait for the job to complete. Refer to documentation on job cancellation.
No alerts are applicable for this message FC014 Message Invalid AttributeValue parameter content for corresponding AttributeName arg1 .
Recommended Response Action No response action is required. Category Configuration (FC = Fiber Channel) Severity Severity 3 (Informational) No alerts are applicable for this message FC017 Message Unable to perform the operation due to an internal error in iDRAC. Detailed Description An internal error occurred in iDRAC and the operation cannot continue. An iDRAC reset is required to recover from the error.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FC103 Message The FC arg1 port arg2 network connection is successfully started. Arguments arg1 = controller ID, arg2 = port ID Detailed Description The network connection of the FC controller port link identified in the message is successfully started. Recommended Response Action No response action required.
FCD Event Messages FCD8500 Message Unable to apply the arg1 configuration. The affected servers (slot arg2 ) are not turned off. Arguments arg1 = configuration name, arg2 = slot number Detailed Description The server specified in the message must be turned off or the server slot must be empty before changing the FlexAddress configuration. Recommended Response Action Turn off the server and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* FCD8503 Message The feature is activated in the chassis: arg1 Arguments arg1 = feature name Detailed Description Chassis already has the feature identified in the message activated. Only one instance of a feature can be activated at a time.
Category Audit (FCD = Feature Card) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* FCD8505 Message The features cannot be deactivated when the chassis is turned on. Detailed Description Features cannot be deactivated when the chassis is turned on.
Detailed Description The CMC is not responding. The chassis has the factory-programmed service tag. Recommended Response Action Contact your service provider.
FLDC Event Messages FLDC1001 Message The journal mirror at path = arg1 is available. Arguments arg1 = World Wide Name Detailed Description The entry in the journal for the device identified in the message with the WWN (World Wide Name) is available. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 160100 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1003 Message Cache flushing has started for the virtual disk with WWN = arg1 and path = arg2 . Arguments arg1 = World Wide Name, arg2 = device pathname Detailed Description The cache flushing operation has started for the virtual disk identified in the message.
Detailed Description The cache flushing operation has completed for the virtual disk identified in the message. Recommended Response Action No response action is required.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1007 Message The cache device arg1 with WWN = arg2 and path = arg3 is removed. Arguments arg1 = physical disk Name, arg2 = World Wide Name, arg3 = device pathname Detailed Description The cache device identified in the message is removed from the Fluid Cache configuration. Recommended Response Action No response action is required.
OMSA Event ID 2905 OMSA Trap ID 90100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1009 Message Caching is being removed for the arg1 with WWN = arg2 and path = arg3 . Arguments arg1 = virtual disk name, arg2 = World Wide Name, arg3 = device pathname Detailed Description Caching is being removed for the virtual disk identified in the message.
Arguments arg1 = virtual disk name, arg2 = World Wide Name, arg3 = device pathname Detailed Description Caching is enabled on the virtual disk identified in the message. Recommended Response Action No response action is required.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1013 Message The cached LUN with WWN = arg1 and path = arg2 for arg3 has had a failure. Arguments arg1 = World Wide Name, arg2 = device pathname, arg3 = virtual disk name Detailed Description The cached LUN identified in the message has had a failure to successfully perform a read or write operation.
Category Storage (FLDC = Unknown) Severity Severity 3 (Informational) OMSA Event ID 2912 OMSA Trap ID 90100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1015 Message Recovery of the cache device arg1 with wwn = arg2 and path = arg3 is complete.
FLDC1016 Message A valid permanent license is installed for Fluid Cache. Detailed Description A valid permanent license is installed for Fluid Cache. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1018 Message A license has been removed for Fluid Cache. Detailed Description A license has been removed for Fluid Cache. Recommended Response Action No response action is required.
Category Storage (FLDC = Unknown) Severity Severity 3 (Informational) OMSA Event ID 2924 OMSA Trap ID 160100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1020 Message The storage device with WWN = arg1 and path = arg2 is in unknown state.
FLDC1021 Message The journal mirror entry with WWN = arg1 is not accessible. Arguments arg1 = World Wide Name Detailed Description The device identified in the message having the journal mirror entry with given WWN (World Wide Name) is not accessible. A portion of an SSD is used for journal content. To assure consistnecy, the journal content is written into two other SSDs. These copies are journal mirrors.
OMSA Event ID 2874 OMSA Trap ID 90300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1023 Message Fluid Cache is running on an evaluation license and the evaluation license expires in arg1 days.
Detailed Description Caching was enabled in write-back mode but currently it is operating in writethrough mode because the fluid Cache Pool has one PCIe-SSD. Recommended Response Action Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1026 Message Caching is no longer degraded to write-through mode and is now operating in write-back mode for Fluid Cache. Detailed Description The caching mode has been restored back to write-back mode due to the availability of additional PCIeSSD devices in the Fluid Cache configuration. Recommended Response Action No response action is required.
OMSA Event ID 2933 OMSA Trap ID 120300;150300,160300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1028 Message OMSS Connection to Fluid Cache service is no longer present. Detailed Description The communications connnection between OMSS and the Fluid Cache service is no longer present.
Detailed Description The message indicates that there are not enough journal mirrors available for Fluid Cache to operate. Make sure that there are at least two journal mirrors that are accessible. Activate either one or more failed cache devices or use the fldc_restore utility to rebuild the node. Recommended Response Action Contact your service provider to diagnose the cause and assist in recovery process.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1031 Message The journal could not be read or written to for Fluid Cache. Detailed Description Unable to access redundant Fluid Cache configuration information. Recommended Response Action Service is required. Contact your service provider.
OMSA Trap ID Filter Visibility 90400 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1033 Message The storage device WWN = arg1 and path = arg2 is either inaccessible or no longer functional. Arguments arg1 = wwn name, arg2 = path name Detailed Description The message indicates that the storage device is either inaccessible or is no longer functional.
Detailed Description A valid license is not installed for Fluid Cache. Recommended Response Action Install a valid Fluid Cache license. For more information, contact your service provider.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1036 Message Caching functionality is disabled because Fluid cache is running on an expired evaluation license (Expired days: arg1 ). Arguments arg1 = number of days Detailed Description Caching functionality is disabled because Fluid cache is running on an expired evaluation license.
Category Storage (FLDC = Unknown) Severity Severity 1 (Critical) OMSA Event ID 2919 OMSA Trap ID 160400 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC FLDC1038 Message There is not enough memory capacity to run necessary services for Fluid Cache. Detailed Description There is not enough memory capacity to run necessary services for Fluid Cache.
FLDC1039 Message One or more cache devices are missing, resulting in Fluid Cache to be unresponsive. Detailed Description One or more cache devices are missing and the cache is unresponsive. Recommended Response Action Insert the missing cache device. If the cache device was unplugged, reactivate it.
FSD Event Messages FSD000 Message Debug authorized by customer; debugcaps: arg1 , was authorized by: arg2 , at arg3 for the period: arg4 to arg5 . Arguments arg1 = DebugCaps, arg2 = iDRAC User, arg3 = unblock time, arg4 = start time, arg5 = end time Detailed Description The customer has authorized the specified debug capabilities on this iDRAC. (This should occur in response to a request from Dell tech support.
Severity Severity 3 (Informational) Trap/EventID 8595 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC FSD002 Message Debug authorization failed; for debugCaps: arg1 , authorized by iDRAC user: arg2 , and Dell employee: arg3 , at arg4 for the period: arg5 to arg6 .
LC Log iDRAC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC 569
HWC Event Messages HWC0001 Message Unable to complete the operation as there is no response from iDRAC. Detailed Description The error is caused due to iDRAC failure. Recommended Response Action 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord and turn on the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC0003 Message Successfully initialized vFlash SD card. Detailed Description vFlash SD card was successfully initialized. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC0005 Message Internal error while retrieving update information. Detailed Description Internal error while retrieving firmware version for the currently installed components. For more information about the failure, see Lifecycle Log. Recommended Response Action 1) Turn off the system and disconnect the power cord.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC0007 Message Unable to load vFlash SD card settings. Detailed Description Lifecycle Controller is unable to retrieve vFlash SD card information from iDRAC. Recommended Response Action Reinsert the vFlash SD card and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC0009 Message Unable to enable vFlash SD card. Detailed Description The vFlash SD card is missing or not inserted correctly. iDRAC is not able to enable vFlash SD card. Recommended Response Action Reinsert the vFlash SD card and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC0011 Message Insufficient space to copy the file to the USB drive. Detailed Description The USB drive does not have sufficient free space to copy the file. Recommended Response Action Make sure the USB drive has sufficient free space before retrying the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC0013 Message Unable to copy the file to USB drive. Detailed Description The USB drive is disconnected or is not readable. Recommended Response Action Remove and reinsert the USB drive and retry the operation. If the problem persists, restart the system and retry.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC0015 Message iDRAC not responding. Detailed Description iDRAC has encountered a hardware error. Recommended Response Action Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord. 2) Wait five seconds.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC HWC1000 Message The arg1 is present. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Re-install or reconnect the hardware. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The is absent. Check hardware Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1002 Message The arg1 is disabled.
HWC1003 Message The arg1 is enabled. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC1004 Message The storage adapter is present.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC HWC1005 Message The storage adapter is absent. Detailed Description The storage adapter may be necessary for proper operation. System functionality may be degraded. Recommended Response Action Install storage adapter. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The storage adapter is absent.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC1007 Message The storage adapter is enabled. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID Filter Visibility iDRAC 2331 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1009 Message The backplane is absent. Detailed Description The backplane may be necessary for proper operation. System functionality may be degraded. Recommended Response Action If removal was unintended, check presence, then re-install or reconnect.
Recommended Response Action If disabled unexpectedly, re-enable backplane. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC HWC1011 Message The backplane is enabled. Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Trap/EventID 2331 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1013 Message The USB cable is absent.
HWC1014 Message The mezzanine card arg1 is present. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC1100 Message The arg1 was installed in slot arg2 . Arguments arg1 = name, arg2 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Trap/EventID 2331 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC1102 Message The arg1 is installed in an unsupported slot arg2 .
HWC1103 Message The arg1 installed in an unsupported slot arg2 is removed. Arguments arg1 = module name, arg2 = slot number Detailed Description The peripheral sled identified in the message is removed from the unsupported slot identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* HWC1105 Message The arg1 is removed from the slot arg2 . Arguments arg1 = module name, arg2 = number Detailed Description The peripheral sled identified in the message is removed from the unsupported slot identified in the message.
Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Trap/EventID 2331 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC1201 Message The sled arg1 is removed from slot arg2 .
HWC1202 Message The arg1 was installed in slot arg2 . Arguments arg1 = name, arg2 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC2000 Message The arg1 cable or interconnect is connected. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Check presence, then re-install or reconnect. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message The cable or interconnect failure.
HWC2003 Message The storage arg1 cable is not connected, or is improperly connected. Arguments arg1 = name Detailed Description The cable may be necessary for proper operation. System functionality may be degraded. Recommended Response Action Check presence, then re-install or reconnect. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message Storage cable or interconnect failure.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC2005 Message The system board arg1 cable or interconnect is not connected, or is improperly connected. Arguments arg1 = name Detailed Description The cable may be necessary for proper operation. System functionality may be degraded.
Detailed Description The device may be necessary for proper operation. System functionality may be degraded. Recommended Response Action Check presence, then re-install or reconnect. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message is not installed correctly.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC HWC2008 Message A fabric mismatch detected for mezzanine card arg1 . Arguments arg1 = number Detailed Description The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the fabric type is then set for the CMC and the CMC will ensure that all subsequent IOMs and mezzanine cards match.
Trap/EventID Filter Visibility iDRAC 2331 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC2010 Message The riser board cable or interconnect is connected. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Check presence, then re-install or reconnect. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message Riser board cable or interconnect failure.
HWC2013 Message Fabric mismatch corrected on fabric arg1 with server in slot arg2 . Arguments arg1 = name, arg2 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC2015 Message The arg1 is configured correctly. Arguments arg1 = name Detailed Description None. Recommended Response Action No response action is required.
Recommended Response Action If removal was unintended, check presence, then re-install or reconnect Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC3001 Message The arg1 is inserted.
HWC3002 Message Server arg1 is removed.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC3004 Message IO module arg1 is removed.
Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Trap/EventID 2331 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC3006 Message Unable to QuickDeploy server in slot arg1 .
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔ ✔* HWC4000 Message A hardware incompatibility detected between BMC/iDRAC firmware and CPU. Detailed Description A hardware incompatibility was detected between BMC/iDRAC firmware and Processor(s). An iDRAC or BMC firmware update is needed. Recommended Response Action Update the BMC/iDRAC firmware. If the problem persists, contact support.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC4002 Message A hardware incompatibility detected between BMC/iDRAC firmware and other hardware. Detailed Description A hardware incompatibility was detected between BMC/iDRAC firmware and other hardware. An iDRAC or BMC firmware update is needed.
Recommended Response Action No response action is required. Category System Health (HWC = Hardware Config) Severity Severity 3 (Informational) Trap/EventID 2331 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔ Reset Chassis Event Proxy ✔ CMC HWC4010 Message Hardware successfully updated for mezzanine card arg1 .
HWC4011 Message Hardware unsuccessfully updated for mezzanine card arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action Check presence, re-install or reconnect, then re-attempt the update. If the problem persists, contact support.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC HWC4013 Message Hardware unsuccessfully updated for embedded NIC. Detailed Description None Recommended Response Action Check presence, re-install or reconnect, then re-attempt the update. If the problem persists, contact support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC4015 Message Link Tuning error detected. Detailed Description CMC has old firmware and does not recognize the new device which has requested link tuning information. After updating the firmware the CMC will recognize the device.
Recommended Response Action 1) Review system documentation for supported mezzanine cards. 2) Replace mezzanine card with a supported mezzanine card.
HWC4018 Message A hardware incompatibility was corrected between arg1 arg2 and arg3 arg4 . Arguments arg1 = first component name, arg2 = first component location location, arg3 = second component name, arg4 = second component location Detailed Description A hardware incompatibility was corrected between the components identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5001 Message arg1 is offline. Arguments arg1 = name Detailed Description None Recommended Response Action If unexpected, check presence, then re-install or reconnect.
Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card. Category System Health (HWC = Hardware Config) Severity Severity 2 (Warning) Trap/EventID 2330 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5003 Message arg1 is operating correctly.
HWC5004 Message A link tuning failure detected on arg1 . Arguments arg1 = name Detailed Description CMC has old firmware and does not recognize the new device which has requested link tuning information. After updating the firmware the CMC will recognize the device. Recommended Response Action Update the CMC firmware. If the problem persists, contact support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5008 Message Console is not available for the arg1 . Arguments arg1 = name Detailed Description None Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Arguments arg1 = name Detailed Description None Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) No alerts are applicable for this message HWC5014 Message arg1 is not functional and is powered off. Arguments arg1 = name Detailed Description None Recommended Response Action Contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5031 Message IO module arg1 is offline. Arguments arg1 = number Detailed Description The CMC has powered off the IOM. Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of both IOMs. Category System Health (HWC = Hardware Config) Severity Severity 2 (Warning) Trap/EventID 2330 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5033 Message IO module arg1 is operating correctly.
HWC5034 Message A link tuning failure detected on IO module arg1 . Arguments arg1 = number Detailed Description Link tuning table not supported for this IO modular. Recommended Response Action Update the CMC firmware. If the problem persists, contact support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC5036 Message A failure is detected on IO module arg1 . Arguments arg1 = number Detailed Description The IOM module performance may be impact. Recommended Response Action Contact technical support.
Recommended Response Action Reseat I/O module. If problem persists, contact the service provider. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC6000 Message The arg1 controller is offline.
HWC6001 Message The arg1 controller is online. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC6003 Message The arg1 controller is booting. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
HWC7000 Message Server arg1 health changed to a normal state. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC7004 Message Server arg1 health changed to a critical state from either a normal or warning state. Arguments arg1 = number Detailed Description Server health changed to a critical state from either a normal or warning state.
Recommended Response Action Review System Log or front panel for additional information. Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC7008 Message Server arg1 health changed to a warning state from more severe state.
HWC7010 Message Server arg1 health changed to a critical state from a non-recoverable state. Arguments arg1 = number Detailed Description Server health changed to a critical state from a non-recoverable state. Recommended Response Action Review System Log or front panel for additional information.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* HWC7014 Message An invalid cable or incorrect cable configuration is detected. Detailed Description An invalid cable related hardware configuration detected on the system. Recommended Response Action Make sure the hardware and related cables are installed correctly.
Category Audit (HWC = Hardware Config) Severity Severity 3 (Informational) OMSA Event ID 5650 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8001 Message A device was added to the system at this location: arg1 . Additional Details: arg2 .
HWC8002 Message The device was removed from the system at this location: arg1 . Additional Details: arg2 . Arguments arg1 = device location, arg2 = details Detailed Description A device was was removed from the system at the location identified in the message. Along with the device location, additional event details are provided if available. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 5653 IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8004 Message The SD card device sensor has failed. SD card location: arg1 , SD card device type: arg2 , SD card state: arg3 . Arguments arg1 = location, arg2 = type, arg3 = state Detailed Description The SD card device sensor of the type identified in the messaage has failed.
Arguments arg1 = location, arg2 = type, arg3 = state Detailed Description The SD card device has returned to a normal state. The SD card type and the current status of the SD card is also displayed. Recommended Response Action No response action is required.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8007 Message The SD card has failed. SD card location: arg1 , SD card device type: arg2 , SD card state: arg3 . Arguments arg1 = location, arg2 = type, arg3 = state Detailed Description The SD card sensor detected an SD card failure. Recommended Response Action Replace the old SD card with a new SD card.
Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) OMSA Event ID 5755 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC HWC8009 Message SD card device sensor value unknown. SD card location: arg1 , SD card device type: arg2 , SD card state: arg3 .
Detailed Description The operation could not successfully completed because of an issue with the I/O panel cable. Recommended Response Action Do one of the following and retry the operation: 1) Connect the I/O panel cable properly 2) Replace the I/O panel cable.
HWC8503 Message Communication to the control panel has been restored. Detailed Description The communication between the Chassis Management Controller (CMC) and the control panel is functioning normally. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* ✔* HWC8506 Message Unable to synchronize control panel firmware due to internal error. Detailed Description During a Chassis Management Controller (CMC) firmware update, the control panel firmware synchronization failed. The control panel may be inoperable. Recommended Response Action Remove and reapply chassis input power. If problem persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* HWC8508 Message A device causing an issue in the I/O panel USB port is removed. Detailed Description A device causing an issue in the I/O panel USB port is removed. Recommended Response Action No response action is required.
Category System Health (HWC = Hardware Config) Severity Severity 1 (Critical) Trap/EventID 2329 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* HWC8510 Message The heat sinks of the PCIe switches are properly attached. Detailed Description The heat sinks of the PCIe switches are properly attached.
IOID Event Messages IOID001 Message The Input/Output Identity (I/O Identity) optimization feature is enabled. Detailed Description After the I/O Identity optimization feature is enabled, the time during boot to configure I/O Identity attributes using the Server Configuration Profile (Configuration XML) import feature will be significantly reduced. Recommended Response Action No response action required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOID003 Message The Virtual Address Persistence Policy setting for Auxiliary powered devices is changed to arg1 . Arguments arg1 = restart type Detailed Description The Virtual Address Persistence Policy setting for Auxiliary powered devices is changed to the restart type identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOID005 Message Storage Initiator Persistence Policy setting is changed to arg1 . Arguments arg1 = restart type Detailed Description The Storage Initiator Persistence Policy setting is changed to the restart type identified in the message. Recommended Response Action No response action is required.
Category Configuration (IOID = IO Identity Optimization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOID110 Message The virtual address of NIC arg1 Port arg2 is configured. Arguments arg1 = controller, arg2 = port Detailed Description The virtual address of NIC port identified in the message is configured.
Detailed Description The virtual address of the NIC port identified in the message could not be successfully configured because either the network port connection is not enabled or the NIC is not capable of Virtual Addressing. Recommended Response Action Verify that the network port is enabled and that the port has Virtual Addressing capability and then retry the operation.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC IOID113 Message Unable to configure the initiator properties of NIC arg1 Port arg2 . Arguments arg1 = Controller, arg2 = Port Detailed Description The initiator properties of the NIC port could not be configured because either iSCSI or FCoE partition of the network port is not enabled, or the network controller is not functioning.
Trap/EventID Filter Visibility iDRAC 10771 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC IOID115 Message Unable to configure the target settings properties of the NIC arg1 Port arg2 .
Recommended Response Action No response action is required.
IOID118 Message Unable to configure some or all I/O Identity settings based on current persistence policy settings. Detailed Description The iDRAC has applied I/O Identity Configuration on NIC and FC HBA devices. One or more of the setting configuration operations did not complete successfully. Recommended Response Action Review the previous log entries and identify the devices that did not successfully complete configuration operations.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC ✔* LCD Reset Chassis Event Proxy ✔ CMC 653
IOV Event Messages IOV000 Message Successfully completed the operation. Detailed Description This operation was successful. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV002 Message Unable to create or allocate the required resources. Detailed Description CMC could not successfully allocate resources because of the following reasons: 1) The chassis manager is unable to allocate required resources. 2) The chassis manager or chassis infrastructure firmware is rolled back to an earlier version. 3) There is an issue with the internal communications between chassis components.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log Reset Chassis Event Proxy iDRAC CMC IOV004 Message Unable to turn on PCIe adapter.
Category Configuration (IOV = IO Virtualization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC CMC WS Eventing ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV006 Message Incorrect Chassis Infrastructure Mainboard firmware version. Detailed Description The Chassis Infrastructure Mainboard firmware is not at the correct version..
Recommended Response Action To release the required power, turn off one or more servers by pressing the Power Button on the individual server units.
Detailed Description The Chassis Management Controller (CMC) runs this function only when the chassis is turned off. Recommended Response Action Turn off the chassis and retry the operation.
IOV011 Message Unable to assign or unassign PCIe slot(s) or virtual adapter (VA) because all affected servers must be turned off. Detailed Description All servers that PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from must be turned off before an assign or unassign operation can be performed. Recommended Response Action Turn off all servers that the PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from, and then retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV013 Message Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA. Detailed Description Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA. Recommended Response Action Unassign the servers current virtual adapter (VA) and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC Remote System Log WS Eventing ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV015 Message Unable to map/un-map or turn on the external shared adapter because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest version supporting the adapter.
Recommended Response Action No response action is required. Category Configuration (IOV = IO Virtualization) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC Remote System Log WS Eventing ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC IOV1001 Message The requested operation was successfully executed. Detailed Description The requested operation was successfully executed.
IOV1003 Message Missing required parameter arg1 . Arguments arg1 = parameter name Detailed Description One or more parameters identified in the message required for the method are missing. Recommended Response Action Refer to the DCIM Chassis PCI Management Profile document and provide the required parameter.
IOV1006 Message Invalid PCI slot or Server slot. Detailed Description The PCI slot or Server slot FQDD (Fully Qualified Device Descriptor) values entered for the operation are not valid. Recommended Response Action Perform the Enumerate operation on the DCIM_ChassisPCISlot class and DCIM_BladeServerView class to get the correct FQDD values for the PCIe slot and Server slot. Retry the operation with the correct FQDD values.
No alerts are applicable for this message IOV1009 Message Mismatch in Slot or Virtual Adapter FQDD and Server Slot FQDD count. Detailed Description The FQDD pairs identified in the messages do not match in the required method input parameters. Recommended Response Action Provide a valid pair of FQDDs. Please refer to the DCIM Chassis PCI Management Profile document for the required parameter definitions.
Arguments arg1 = device name, arg2 = slot type, arg3 = slot number Detailed Description The Chassis Management Controller (CMC) detected the removal of an adapter card from the slot identified in the message. Recommended Response Action No response action is required.
LC Log LCD OS Log ✔* ✔* ✔ Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* IOV104 Message The Chassis Management Controller (CMC) is unable to allocate arg1 Watt for server- arg2 PCIe adapters. Arguments arg1 = number of Watt, arg2 = server slot number Detailed Description For each adapter assigned to a server, power is allocated when the server is turned on.
Recommended Response Action Make sure that supported adapters are used and installed correctly in the PCIe slot. Category System Health (IOV = IO Virtualization) Severity Severity 2 (Warning) Trap/EventID 2554 Filter Visibility iDRAC ✔ CMC ✔ IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔* ✔ Power Off Power Cycle LC Log LCD OS Log ✔* ✔* ✔ Reset Chassis Event Proxy iDRAC CMC ✔* IOV106 Message Unable to power on PCIe adapter arg1 in arg2 arg3 .
IOV107 Message PCIe adapter arg1 in slot arg2 was removed while powered on. Arguments arg1 = device dame, arg2 = slot number Detailed Description The Chassis Management Controller (CMC) has detected the removal of a PCIe adapter card while it was powered on. Recommended Response Action Power down the affected server(s) and then power on the server(s). Note: OS reboot only will not correct this issue.
Filter Visibility iDRAC ✔ CMC ✔ IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔* ✔* ✔ Power Off Power Cycle LC Log LCD OS Log ✔* ✔* ✔ Reset Chassis Event Proxy iDRAC CMC ✔* IOV109 Message An error condition associated with the PCIe slot is cleared. Detailed Description An error condition associated with the PCIe slot is cleared. Recommended Response Action No response action is required.
Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔* IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy ✔* IOV111 Message Unable to update Chassis Infrastructure firmware. Detailed Description Unable to successfully update Chassis Infrastructure firmware. Recommended Response Action Refer to the release notes of the Mainboard update package for recommended action.
Category System Health (IOV = IO Virtualization) Severity Severity 1 (Critical) Trap/EventID 2553 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* IOV113 Message Chassis Infrastructure firmware re-installation is successful. Detailed Description Chassis Infrastructure firmware re-installation is successful.
Detailed Description The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been assigned to the server identified in the message. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV116 Message PCIE AUX power cable arg1 .was disconnected while powered on. Arguments arg1 = cable number Detailed Description The Chassis Management Controller (CMC) detected a power fault in an PCIE AUX power cable after the adapter was powered on. A power fauilt may be caused by a loose cable connection to the adapter or between the cable and the AUX cable harness.
Severity Severity 3 (Informational) Trap/EventID 10747 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC ✔ LC Log LCD Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV118 Message Fabric arg1 is down. Arguments arg1 = fabric ID Detailed Description The Fabric identified in the message is not up and a chassis power cycle is required. Recommended Response Action Power cycle the chassis.
Recommended Response Action No response action is required. Category Configuration (IOV = IO Virtualization) Severity Severity 3 (Informational) Trap/EventID 10747 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC ✔ LC Log LCD Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* ✔ ✔* IOV120 Message PCIe ride-through mode is enabled.
IOV121 Message PCIe ride-through time out has changed from arg1 to arg2 seconds. Arguments arg1 = seconds, arg2 = seconds Detailed Description The Chassis Management Controller (CMC) has changed the PCIe ride-through timeout to the value identified in the message. PCIe adapters will remain turned on for the number of seconds specified by the ride-through timeout value after the server they are assigned to is turned off. Note: A value of zero equals infinite number of seconds.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC CMC ✔ Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ Power Off Power Cycle LC Log LCD OS Log ✔* ✔ ✔ Reset Chassis Event Proxy iDRAC CMC ✔* IOV123 Message arg1 arg2 is unassigned/unmapped from extended server slot arg3 .
Detailed Description The PCIe shared adapter in slot identified in the message is not supported because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest. Recommended Response Action Remove the adapter or update the Chassis Infrastructure firmware and then retry the operation. Using Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a -d mainboard.
LC Log LCD ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* 681
IPA Event Messages IPA0001 Message Invalid NIC IP address parameter specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the valid IP Address. Category Audit (IPA = DRAC IP Address) Severity Severity 2 (Warning) No alerts are applicable for this message IPA0002 Message Invalid IP address specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter a valid IP Address.
IPA0004 Message Invalid gateway address specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the appropriate gateway. Category Audit (IPA = DRAC IP Address) Severity Severity 2 (Warning) No alerts are applicable for this message IPA0100 Message The iDRAC IP Address changed from arg1 to arg2 .
ISM Event Messages ISM0000 Message The iDRAC Service Module is started on the operating system (OS) of server. Detailed Description The iDRAC Service Module is started on the OS of server. Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0001 Message The iDRAC Service Module detected a OS to iDRAC Pass-through in the arg1 mode.
Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0003 Message The iDRAC Service Module is unable to discover iDRAC from the operating system of the server. Detailed Description The iDRAC Service Module could not successfully discover iDRAC from the server OS. However, the iDRAC Service Module will continue the discovery operation.
Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0006 Message The iDRAC Service Module is unable to communicate with iDRAC using the OS to iDRAC Pass-through channel. Detailed Description The iDRAC Service Module could not successfully communicate with iDRAC, because the OS to iDRAC Pass-through channel is not configured in the USB-NIC mode.
ISM0008 Message Some features of iDRAC Service Module will be disabled on this server, because OpenManage Server Administrator is running on the operating system (OS) of this server. Detailed Description iDRAC Service Module detected that OpenManage Server Administrator is running on the OS of this server. Therefore, one or more features of iDRAC Service Module will be disabled. Recommended Response Action End the OpenManage Server Administrator session.
Recommended Response Action If the requesting source is iDRAC, enable the iDRAC Service Module on the iDRAC before starting this service on the server OS. To enable the Service Module by using iDRAC GUI: Click Network, click OS to iDRAC Pass-through, and then click the USB NIC option. In the OS IP Address box , type an IP address, and then click Apply. To enable the module by using RACADM command, run the following command at the command line interface: racadm set idrac.servicemodule.
ISM0013 Message The feature arg1 is enabled. Arguments arg1 = feature name Detailed Description The feature identified in the message is enabled by using the one of the iDRAC interfaces. Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0014 Message The feature arg1 is disabled.
ISM0016 Message The BMC watchdog reset time is changed to arg1 seconds. Arguments arg1 = reset time Detailed Description The BMC watchdog reset time is changed to a value identified in the message. Recommended Response Action No response action is required. Category Audit (ISM = iDRAC Service Module) Severity Severity 3 (Informational) No alerts are applicable for this message ISM0017 Message The BMC watchdog auto-recovery action is changed from arg1 to arg2 .
ISM0019 Message The OS Collector application did not start successfully on the server operating system (OS) because checksum verification did not succeed for some files. Detailed Description The OS Collector application did not start successfully on the server operating system (OS), because checksum verification did not succeed for some files. Recommended Response Action Do the following: 1) Retry the operation.
No alerts are applicable for this message ISM0022 Message The OS Collector application did not start successfully on the server operating system (OS) because the application encountered an error. Detailed Description The OS Collector application did not start successfully on the server operating system (OS) because the application encountered an error. Recommended Response Action Do the following: 1) Retry the operation.
JCP Event Messages JCP000 Message A new job with ID arg1 is created. Arguments arg1 = ID number Detailed Description A new job with the ID identified in the message is created. Recommended Response Action No response action is required.
Detailed Description The Lifecycle Controller is not able to schedule a job at this time because of an internal error. Recommended Response Action Wait up to three minutes and retry the operation. If the problem persists, reboot the system and enumerate DCIM_Lifeycle Job to view the list of jobs that are currently scheduled. Category Configuration (JCP = Job Control) Severity Severity 2 (Warning) No alerts are applicable for this message JCP003 Message The Job did not complete successfully.
Recommended Response Action Enable system services through the CTRL+E on boot up on the target system through the iDRAC configuration utility. Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) No alerts are applicable for this message JCP006 Message Invalid job attribute. Detailed Description One or more of the specified values for creating a job are invalid or an internal error has occurred when scheduling the job.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC JCP008 Message Job completed with errors. Detailed Description Multiple attributes were set in the operation but some set attribute actions were not successful.
Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) No alerts are applicable for this message JCP010 Message The command was successful. Detailed Description The method invoked was successfully completed. Recommended Response Action No response action is required. Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) No alerts are applicable for this message JCP011 Message Invalid parameter value for arg1 .
Severity Severity 1 (Critical) No alerts are applicable for this message JCP013 Message Missing parameter(s) arg1 Arguments arg1 = parameters Detailed Description One or more required input parameters needed for the operation are missing. Recommended Response Action Refer to the documentation for the operation being attempted and provide valid values for the identified parameters.
Recommended Response Action Wait for the job to have a completed job status. Retry the operation. Category Configuration (JCP = Job Control) Severity Severity 2 (Warning) No alerts are applicable for this message JCP016 Message Invalid UntilTime value. A minimum of 5 minutes is required. Detailed Description The UntilTime input parameter for the job or job queue creation must be at least 5 minutes after the value specified in the StartTime parameter.
Detailed Description A new job cannot be created until the existing Export job is completed or the job is deleted. There can only be one Export Server Profile job running at a time. Recommended Response Action Do one of the following: 1) Retry the operation after the Export Server Profile job is completed. 2) Delete the scheduled Export job and retry the operation.
Recommended Response Action Retry the operation. If the issue persists, reset the iDRAC. Category Configuration (JCP = Job Control) Severity Severity 2 (Warning) No alerts are applicable for this message JCP022 Message Invalid Job ID arg1 for scheduling or deletion operation. Arguments arg1 = jobid number Detailed Description An invalid Job ID was provided as input for a scheduling or deletion operation. The Job ID indicated in the message does not match an existing Job on the target system.
Recommended Response Action Wait for current Lifecycle Controller operation to complete. Verify that the system is: 1) Not currently in Lifecycle Controller Unified Server Configurator 2) Not waiting for user intervention at F1/F2 POST error 3) Not in any of the device or controller Option ROMs. Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) No alerts are applicable for this message JCP025 Message Lifecycle Controller is not enabled.
Detailed Description An install or configuration job is successfully created on iDRAC. Recommended Response Action No response action is required. Category Configuration (JCP = Job Control) Severity Severity 3 (Informational) Trap/EventID 10267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle CMC LC Log LCD iDRAC Reset Chassis Event Proxy ✔ CMC JCP028 Message Job status updated.
JCP029 Message A Job of JobType arg1 already exists. Arguments arg1 = parameter Detailed Description Only one Job of the JobType requested can be created or scheduled at any time. A job of the same type already exists in the job queue. Recommended Response Action Wait until the existing job is complete or delete the existing job and then retry the operation.
Detailed Description The job ID specified as input to the operation has configuration data that is currently being processed by the iDRAC. The job can be deleted after the processing is done. Recommended Response Action Retry the operation. If the issue persists, reset the iDRAC by pressing the System ID button for 15 seconds, wait for the iDRAC to finish restarting, and then retry the operation.
Recommended Response Action No response action is required.
LC Event Messages LC001 Message Command successful. Detailed Description The command completed successfully. Recommended Response Action No response action is required. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC002 Message General failure. Detailed Description A general failure occurred while executing the command. Recommended Response Action Verify network connectivity.
LC004 Message Provisioning Server information is not formatted correctly. Detailed Description The Provisioning Server parameter information is not formatted correctly. Recommended Response Action Verify the string format. Enter a valid IP address or hostname for the Provisioning Server such as: 1) hostname 2) hostname.domain.com 3) 1.1.1.1 4) hostname:8080 5) hostname.dell.
LC007 Message Invalid Parameter. Detailed Description One of the parameters specified in the method is invalid. Recommended Response Action Verify that the parameters specified are correct. For a list of parameters for this method refer to the Lifecycle Controller User Guide. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC008 Message Unsupported method parameter value.
LC010 Message Certificate imported successfully. Detailed Description The communications encryption certificate was imported successfully. Recommended Response Action No response action is required. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC0100 Message Lifecycle Controller has entered Recovery mode. Detailed Description A persistent error has occurred while carrying out a Lifecycle Controller operation.
LC011 Message Certificate import operation failed. Detailed Description There was a general failure in the certificate import process. Recommended Response Action Try one of the following: 1) Rerun the command. 2) Reset iDRAC and run the command. Category Configuration (LC = Lifecycle Contr) Severity Severity 1 (Critical) No alerts are applicable for this message LC012 Message Another process is using Lifecycle Controller. Detailed Description Lifecycle Controller is in use by another process.
LC014 Message Maximum comment length is 255 characters. Detailed Description Maximum comment length is 255 characters. Recommended Response Action Limit the number of characters in the comment to 255 characters.
LC017 Message Invalid value for the parameter, arg1 . Arguments arg1 = parameter Detailed Description A parameter value provided when the method was invoked is not valid. Recommended Response Action Verify that parameter values provided to the method are typed as they appear in the enumeration and that the parameter data type matches the Lifecycle Controller Profile documentation.
LC020 Message PKCS12 decrypt of the certificate could not complete. Detailed Description The contents of the PKCS12 parameter was not valid because: 1) not a valid PKCS12 file 2) not a valid pfx file 3) did not contain a certificate that matched the private key in the file. Recommended Response Action Validate that the PKCS12 content was Base64 encoded. OpenSSL can be used to create or validate a PKCS12 encoding.
LC023 Message Cannot access network share. Detailed Description Credentials or network share identity information provided did not result in a network connection being established. Recommended Response Action Check network share access credentials (IP address, user name, password, share type, and so on). Refer to Lifecycle Controller Profile documentation for more details.
LC026 Message Lifecycle Controller Log Export method is not supported. Detailed Description This method is not supported in this version of the iDRAC firmware. Recommended Response Action Update the iDRAC firmware to a version that supports the log export. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC027 Message The Hardware Inventory file export was successful.
LC029 Message Invalid file path specified. Detailed Description An invalid File Path was specified in the export operation. Recommended Response Action Correct the specified file path and try again. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC030 Message The file path is to a read-only file system. Detailed Description The file path specified for the operation is a read-only file system.
LC032 Message The Hardware Inventory Export method not supported. Detailed Description This method is not supported in the current version of iDRAC firmware. Recommended Response Action Update the iDRAC firmware to a version that supports this method. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC033 Message As-Shipped Hardware Inventory export was successful.
LC035 Message As-Shipped Hardware Inventory Export method is not supported. Detailed Description This method is not supported in this version of Firmware. Recommended Response Action Update the iDRAC firmware to a version that supports this method. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC036 Message Lifecycle Controller is not enabled.
LC038 Message An instance of Hardware Inventory export is already in progress. Detailed Description Lifecycle Controller is locked by another instance of the Hardware Inventory export process. Allow the process to complete before attempting another export operation. Recommended Response Action Do one of the following: 1) Rerun the command after about 2 minutes 2) Reset the iDRAC and rerun the command.
LC041 Message Console name configure failed Detailed Description The length of the Console name exceeds the maximum length allowed or the file operation error encountered. Recommended Response Action Change the name of a console to a name less than 32 characters.
LC044 Message An instance of Lifecycle Controller system configuration wipe is already running. Detailed Description The Lifecycle Controller system configuration wipe operation is currently running. The operation deletes user information from system hardware and resets BIOS, iDRAC and Lifecycle Controller to default settings. The current operation and system restart must complete before the operation can be attempted again.
LC047 Message An instance of DownloadClientCerts is already running. Detailed Description The DownloadClientCerts operation is in progress. The operation may take a few minutes to compete before the operation can be attempted again. Recommended Response Action Wait a few minutes before retrying retry the operation. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC048 Message Invalid input value for IPChangeNotifyPS.
LC050 Message Invalid value for SystemServicesState. Detailed Description The value provided to set the attribute identified in the message is invalid. Recommended Response Action For more information on the valid values, see Lifecycle Controller-Remote Services documentation. Retry the operation with a valid value for the SystemServicesState attribute.
LC053 Message Lifecycle Controller Remote Services is currently unavailable. Detailed Description Lifecycle Controller Remote Service is either not ready or currently reloading server information. Recommended Response Action Retry the operation. If the issue persists, refer to Lifecycle Controller-Remote Services documentation for more information.
LC056 Message AttributeName and AttributeValue count mismatch. Detailed Description The name value pairs in the input parameter arrays do not match in the input. Recommended Response Action Retry the operation with a valid (AttributeName, AttributeValue) pair. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC057 Message Invalid AttributeName parameter value.
LC059 Message Cannot set read only attribute specified in AttributeName arg1 . Arguments arg1 = parameter Detailed Description The attribute specified is read only and the value cannot be changed. Recommended Response Action No response action is required.
LC062 Message Export or Import server profile operation is already running. Detailed Description Export or Import server profile operation is already running. The operation may take a few minutes to compete. Recommended Response Action To retry the operation, wait for a few minutes. Category Configuration (LC = Lifecycle Contr) Severity Severity 2 (Warning) No alerts are applicable for this message LC063 Message Cannot create new jobs until the existing running jobs are completed or deleted.
LC065 Message The iDRAC static IP address information is not fully configured. The missing attribute InstanceID is arg1 . Arguments arg1 = attribute key Detailed Description The static IPv4 information for the iDRAC represented by the related iDRACCard Attributes must be configured correctly. Recommended Response Action Configure the iDRAC static IP address information by setting the related iDRACCard Attributes.
LC068 Message Unable to perform the import or export operation because there are pending attribute changes or a configuration job is in progress. Detailed Description The import or export system configuration operation cannot be performed because there are pending attribute changes or a configuration job is in progress. Recommended Response Action Apply or cancel any pending attribute changes.
LC071 Message The Lifecycle Controller version does not support the export or import of the Server Configuration XML file. Detailed Description Unable to export or import server configuration XML because the Lifecycle Controller version on the target does not support this feature. Recommended Response Action Update the Lifecycle Controller version on the target system to a version that supports the export and import server configuration XML feature, and retry the operation.
LC074 Message The Certificate export operation did not complete successfully. Detailed Description The Certificate export operation did not complete successfully. Recommended Response Action Retry the operation. If the issue persists, restart the iDRAC and retry the operation. Category Configuration (LC = Lifecycle Contr) Severity Severity 3 (Informational) No alerts are applicable for this message LC075 Message The Custom Signed Certificate (CSC) is deleted successfully.
LC077 Message Certificate imported successfully.Reset iDRAC to apply new certificate. Until iDRAC is reset old certificate will be active Detailed Description The new certificate will not be in-use until iDRAC has been restarted Recommended Response Action No response action is required.
LIC Event Messages LIC000 Message The License Manager action succeeded. Detailed Description This command was successful. Recommended Response Action No response action is required. Category Audit (LIC = Licensing) Severity Severity 3 (Informational) No alerts are applicable for this message LIC001 Message The License Manager command parameter used is invalid. Detailed Description The command or command parameters passed to License Manager is invalid.
Recommended Response Action If the firmware has been rolled back to a previous version, this error may occur. All previously installed licenses must be re-imported. If this is not the case, contact technical support. Category Audit (LIC = Licensing) Severity Severity 1 (Critical) No alerts are applicable for this message LIC003 Message License Manager was unable to create and/or allocate the required resources. Detailed Description System resources may be unavailable at the time command is issued.
Detailed Description The maximum number of installed licenses has been reached. Recommended Response Action Delete one of the currently installed licenses and retry the import. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC006 Message The license has expired. Detailed Description The license end date has been reached. Recommended Response Action Obtain a replacement license and import it.
Detailed Description All bound perpetual licenses contain the unique identifier of a specific device. The unique identifier binds a license to the device. For example, iDRACs unique identifier is the service tag. Recommended Response Action Obtain a new license file with the correct unique identifier for the device. To use this license, import to the device with the correct unique identifier.
Detailed Description License Manager does not allow the replacement of a non-evaluation license with an evaluation license. Recommended Response Action To replace a non-evaluation license, first delete the non-evaluation license, then import the evaluation license. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC012 Message The license file does not exist.
Detailed Description An attempt to lock the License Manager database for Lifecycle Controller backup or restore occurred when the License Manager database was already locked. This may occur when two or more users attempt to do a backup or restore operation simultaneously. Recommended Response Action Repeat the Lifecycle Controller backup or restore operation.
Detailed Description This error can occur when the license file: 1) Signature is not valid. 2) Data is not in the correct format. 3) Missing needed data. 4) Contains unknown data. 5) Has not been unzipped. Recommended Response Action Download the license file, unzip and import the license. Category Audit (LIC = Licensing) Severity Severity 1 (Critical) No alerts are applicable for this message LIC018 Message The license is already imported.
system allows the user to override the warning by invoking the import override option. Recommended Response Action If the base license was deleted, override the warning by invoking the import override option. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC021 Message Import failed: The features contained in the evaluation license are already licensed.
Recommended Response Action Turn off the respective device and retry the License operation. Category Audit (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC201 Message License arg1 assigned to device arg2 expires in arg3 days. Arguments arg1 = entitlement ID, arg2 = device name, arg3 = number of days Detailed Description This license is going to expire.
Category Audit (LIC = Licensing) Severity Severity 1 (Critical) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔* ✔* OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* LIC203 Message The license arg1 has encountered an error. Arguments arg1 = entitlement ID Detailed Description Signature verification failed due to an error in the saved license file.
Recommended Response Action Repeat the Lifecycle Controller restore operation. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Arguments arg1 = entitlement ID Detailed Description The license was imported after the user overrode EULA warning. Recommended Response Action Remove the license if the import violates the EULA.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* LIC208 Message License arg1 imported to device arg2 successfully. Arguments arg1 = entitlement ID, arg2 = device name Detailed Description A license was successfully imported. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔* ✔ ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* LIC210 Message License arg1 deleted from device arg2 successfully. Arguments arg1 = entitlement ID, arg2 = device name Detailed Description A license was successfully deleted. Recommended Response Action No response action is required.
Category Audit (LIC = Licensing) Severity Severity 3 (Informational) Trap/EventID 8515 Filter Visibility iDRAC IPMI Alert ✔ CMC LC Log iDRAC ✔* CMC ✔* LCD SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔ ✔* ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* LIC212 Message The CMC features are changed. Detailed Description The features are updated because the license was imported or deleted, or the license has expired.
Recommended Response Action Reset CMC. Category Audit (LIC = Licensing) Severity Severity 1 (Critical) Trap/EventID 8513 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* LIC501 Message A required license is missing or expired.
LIC503 Message Unable to complete the current operation. The currently installed license does not support the following features: arg1 . Arguments arg1 = licensable features Detailed Description The currently installed license does not support the feature for the requested operation. The operation requires a valid license to enable specific features in the system. Since the required license is missing or expired, the features that are being accessed during the operation are disabled.
Severity Severity 2 (Warning) No alerts are applicable for this message LIC902 Message Resource allocation failure. Detailed Description Unable to allocate the resource because of lack of memory or file space in the iDRAC. Recommended Response Action Reset iDRAC and retry the operation. Category Configuration (LIC = Licensing) Severity Severity 1 (Critical) No alerts are applicable for this message LIC903 Message Missing parameters arg1 .
No alerts are applicable for this message LIC905 Message The LicenseName value cannot exceed 64 characters. Detailed Description The LicenseName value is greater than the allowed max length of 64. Recommended Response Action Correct the length of the LicenseName value and retry the operation. Category Configuration (LIC = Licensing) Severity Severity 2 (Warning) No alerts are applicable for this message LIC906 Message License file is not accessible on the network share.
LNK Event Messages LNK0001 Message Network share name unavailable. Detailed Description The entered network share name is not valid. Recommended Response Action Enter a valid network share name and retry the operation. For more information, see Lifecycle Controller Users Guide.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC LNK0003 Message Unable to connect to the DNS server. Detailed Description Cannot connect to the DNS server because of network issues or there is no response from the DNS server. Recommended Response Action Verify that the server is connected to the network and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC LNK0005 Message Unable to connect to DHCP server. Detailed Description Error occurred while communicating with the DHCP server because the network settings are not configured correctly or the DHCP server could not be contacted. Recommended Response Action Verify if the network cable is connected and network configuration settings are correct, and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* LNK2701 Message The arg1 network link is up. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Do one of the following, and then retry the operation: 1) Check whether or not the external network cable is functioning. 2) Reinstall or replace network cable of the IOM and port identified in the message.
LOG Event Messages LOG001 Message Missing required InstanceID or JobID parameter. Detailed Description One or more required parameters needed for the method invoked in the operation are missing. Recommended Response Action To provide the correct value for the specified parameter, see Lifecycle ControllerRemote Services documentation.
LOG004 Message Resource allocation failure. Detailed Description The operation did not complete successfully because of lack of memory or file space in iDRAC firmware. Recommended Response Action Reset iDRAC and retry the operation. Category Configuration (LOG = Log event) Severity Severity 1 (Critical) No alerts are applicable for this message LOG005 Message Cannot perform the operation due to an unknown error in iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC LOG007 Message The previous log entry was repeated arg1 times. Arguments arg1 = log entry count Detailed Description This message is generated after a series of sequential duplicate events. Log entry count is the number of times the previous message was repeated.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC LOG201 Message Recovered from Lifecycle Controller Log corruption. Detailed Description Lifecycle Controller Log corruption was detected during iDRAC boot. The Lifecycle Controller Log was truncated at the point of corruption.
Detailed Description This message is generated while archiving Lifecycle Log. All the older messages are archived and can be retrieved using the export Lifecycle Log feature. Recommended Response Action No response action is required.
LOG300 Message The system recovered from Chassis Log file corruption. Detailed Description The system recovered from Chassis Log file corruption. Some log entries may not be recovered. Recommended Response Action No response action is required. Category Configuration (LOG = Log event) Severity Severity 3 (Informational) No alerts are applicable for this message LOG302 Message The Chassis Log file header is corrupted. Detailed Description The Chassis Log file header is corrupted.
LOG305 Message The Chassis Log file was cleared. Detailed Description The Chassis Log file was cleared as a result of clear log operation. Recommended Response Action No response action is required. Category Configuration (LOG = Log event) Severity Severity 3 (Informational) No alerts are applicable for this message LOG320 Message Log monitoring is disabled. Log type: arg1 . Arguments arg1 = log type Detailed Description The hardware log in the system is disabled.
Detailed Description The hardware log may not be up-to-date. The log type information is provided. Recommended Response Action Make sure that iDRAC is functioning correctly.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC LOG323 Message The log size is near maximum capacity. Log type: arg1 . Arguments arg1 = log type Detailed Description The size of a hardware log in the system is near its maximum capacity. The log type information is provided. Recommended Response Action Clear the log to make sure new entries are recorded.
OMSA Event ID 5554 OMSA Trap ID 5554 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC LOG325 Message Unable to receive any log entries. Log type: arg1 . Arguments arg1 = log type Detailed Description Unable to receive any log entries, and therefore log status cannot be monitored. The log type information is provided.
Recommended Response Action No response action is required. Category Audit (LOG = Log event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC LOG327 Message An Alert Log backup was created. Detailed Description An Alert Log backup was created. Recommended Response Action No response action is required.
Detailed Description The Server Based Management Mode is enabled. Chassis based PSUs, fans, and sensor information can be displayed from server based system management tools. Recommended Response Action No response action is required.
LOG501 Message Unable to run the command because of a general issue. Detailed Description The command cannot be run because a general issue occurred. Recommended Response Action Retry the operation. If the issue persists, reset the CMC, and then retry the operation. Category Configuration (LOG = Log event) Severity Severity 1 (Critical) No alerts are applicable for this message LOG502 Message Unable to run the command because the method parameter arg1 is missing.
LOG504 Message Chassis Log Export was successful. Detailed Description The Chassis Log was successfully exported to the destination specified. Recommended Response Action No response action is required. Category Configuration (LOG = Log event) Severity Severity 3 (Informational) No alerts are applicable for this message LOG505 Message Unable to access the network share. Detailed Description The network share access cannot be accessed.
LOG507 Message Unable to allocated required CMC resources. Detailed Description The operation did not complete successfully because of lack of memory or file space in the CMC. Recommended Response Action Reset the CMC and retry the operation. Category Configuration (LOG = Log event) Severity Severity 1 (Critical) No alerts are applicable for this message LOG508 Message Unable to write to the network share.
LOG510 Message Unable to complete the operation because of an unknown issue in the CMC. Detailed Description The operation cannot be completed because of an unknown issue. Recommended Response Action Retry the operation. If the issue persists, reset CMC and then retry the operation.
MEM Event Messages MEM0000 Message Persistent correctable memory errors detected on a memory device at location(s) arg1 . Arguments arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0002 Message Parity memory errors detected on a memory device at location arg1 . Arguments arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component.
Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
MEM0005 Message Persistent correctable memory error limit reached for a memory device at location(s) arg1 . Arguments arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0007 Message Unsupported memory configuration; check memory device at location arg1 . Arguments arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0009 Message Memory device at location arg1 is throttled. Arguments arg1 = location Detailed Description System performance is degraded.
MEM0010 Message Memory device at location arg1 is overheating. Arguments arg1 = location Detailed Description System performance is degraded. Recommended Response Action If unexpected, review system logs for power or thermal exceptions. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory device is over heating.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0020 Message Memory device at location arg1 is enabled. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0022 Message Memory device at location arg1 is absent.
MEM0024 Message Memory device at location arg1 is no longer spare memory. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM0601 Message Memory device is removed from location arg1 . Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM0701 Message Correctable memory error rate exceeded for arg1 . Arguments arg1 = location Detailed Description The memory may not be operational. This an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component.
Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Correctable memory error rate exceeded for . Reseat memory.
MEM1001 Message Memory device at location arg1 failed to transition to a running state. Arguments arg1 = location Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health (MEM = Memory) Severity Severity 1 (Critical) LCD Message Memory device failed to transition to a running state.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1003 Message Memory device at location arg1 failed to transition to in test. Arguments arg1 = location Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1005 Message Memory device at location arg1 failed to power off.
MEM1006 Message Memory device at location arg1 is online. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1008 Message Memory device at location arg1 is offline. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Re-attempt memory removal process Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1010 Message Memory device at location arg1 is off-duty.
MEM1011 Message Memory device at location arg1 is on-duty. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1013 Message Memory device at location arg1 is in a full state. Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1015 Message Memory device at location arg1 is in a power active state.
MEM1016 Message Memory device at location arg1 is not installed correctly. Arguments arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced. Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory is not installed correctly.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1200 Message Memory RAID is redundant. Detailed Description None Recommended Response Action No response action is required.
Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory RAID lost on . Power cycle system Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1202 Message Memory RAID redundancy is degraded. Check memory device at location(s) arg1 .
MEM1203 Message Memory is not redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap/EventID 2267 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1204 Message Memory mirror is redundant.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM1205 Message Memory mirror redundancy is lost. Check memory device at location(s) arg1 . Arguments arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Recommended Response Action Review system logs for memory exceptions.
Trap/EventID Filter Visibility iDRAC 2266 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC MEM1207 Message Memory spare is redundant. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Review system logs for memory exceptions. Re-install memory at location Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory spared lost on .
MEM1210 Message Memory is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC MEM1212 Message Memory redundancy is lost.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM1214 Message Memory redundancy is degraded. Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Recommended Response Action Review system logs for memory exceptions.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM6001 Message Memory device status is unknown. Memory device location: arg1 , Possible memory module event cause: arg2 . Arguments arg1 = location, arg2 = cause Detailed Description The memory module may not be correctly seated, wrongly configured, or has failed.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) OMSA Event ID 5402 OMSA Trap ID 5402 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM6003 Message Memory device status is non-critical. Memory device location: arg1 , Possible memory module event cause: arg2 .
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM6004 Message Memory device status is critical. Memory device location: arg1 , Possible memory module event cause: arg2 . Arguments arg1 = location, arg2 = cause Detailed Description The memory module may not be correctly seated, wrongly configured, or has failed. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions.
Category System Health (MEM = Memory) Severity Severity 1 (Critical) OMSA Event ID 5405 OMSA Trap ID 5405 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC MEM7000 Message The memory riser mismatch was corrected. Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action Review product documentation for proper memory riser installation and configuration Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory riser mismatch detected.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM8001 Message Persistent correctable memory error logging enabled for a memory device at location arg1 . Arguments arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* MEM8501 Message Low memory warning, arg1 KB, arg2 KB. Arguments arg1 = total memory size, arg2 = threshold value Detailed Description A low memory condition was detected. If this condition continues, a failover or a reset may occur.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* MEM9000 Message Memory interconnect degraded. Detailed Description An issue is detected in the propagation of signals between the processor and the memory. Recommended Response Action Do one of the following: 1) Reseat the memory riser and restart the server.
Recommended Response Action No response action is required. Category System Health (MEM = Memory) Severity Severity 3 (Informational) LCD Message Memory interconnect normal. Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ ✔ OS Log Power Off Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD ✔* Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9002 Message Intel QPI interconnect arg1 has a correctable error.
MEM9003 Message Intel SMI 2 Memory interconnect arg1 has a correctable error. Arguments arg1 = link number Detailed Description A correctable error was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message. Recommended Response Action Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert ✔ ✔ OS Log Power Off Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD ✔* Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9005 Message Intel SMI 2 Memory interconnect arg1 has degraded. Arguments arg1 = link number Detailed Description A link degradation was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, contact your service provider. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Intel QPI interconnect has fatal error. Reseat memory riser.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC MEM9008 Message Intel DDR Memory interconnect arg1 has a non-recoverable issue. Arguments arg1 = link number Detailed Description A non-recoverable issue was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message. Recommended Response Action Reseat all DIMMs on the memory riser, reseat the memory riser, and restart the server.
Trap/EventID 2266 LCD Message Intel DDR interconnect has a correctable error. Reseat mem riser.
NIC Event Messages NIC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
NIC004 Message Invalid parameter value for arg1 Arguments arg1 = attribute name Detailed Description The value for the specified parameter is invalid. Recommended Response Action Verify that parameter values passed to the method are entered as they appear in the enumeration and parameter data type matches the documentation.
NIC007 Message A configuration job already exists, Cannot create another configuration job on specified target until existing job is completed or is cancelled Detailed Description A configuration job already exists for the specified target. No further configuration operation is allowed until the existing job completes or the job is cancelled.
NIC010 Message Lifecycle Controller is not enabled, cannot create Configuration job. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation.
Severity Severity 3 (Informational) No alerts are applicable for this message NIC013 Message Invalid AttributeName: arg1 Arguments arg1 = attribute name Detailed Description An unknown AttributeName was entered for the operation. Recommended Response Action Enter the correct AttributeName available in the system. Refer to the enumeration response for desired attribute.
Recommended Response Action No response action is required. Category Configuration (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC016 Message AttributeValue cannot be changed for disabled AttributeName arg1 . Arguments arg1 = attribute name Detailed Description A set attribute operation was attempted on a disabled attribute. Recommended Response Action No response action is required.
Recommended Response Action Use a valid BIOS password and retry. Category Configuration (NIC = NIC Config) Severity Severity 2 (Warning) No alerts are applicable for this message NIC021 Message Cannot authenticate specified BIOS password. Detailed Description The old BIOS password used to change the password is incorrect. Recommended Response Action Enter the correct old password for the BIOS and retry the operation.
Category Configuration (NIC = NIC Config) Severity Severity 2 (Warning) No alerts are applicable for this message NIC024 Message The set operation did not complete successfully as the attribute is read-only. Detailed Description The attribute specified in the operation is currently read only and the value cannot be modified. Recommended Response Action For more information on the attribute, see Lifecycle Controller-Remote Services documentation.
NIC101 Message The NIC arg1 Port arg2 network link is started. Arguments arg1 = controller ID, arg2 = port ID Detailed Description The transition from network link not started (down) to network link started (up) has been detected on the NIC controller port identified in the message. Recommended Response Action No response action is required.
Detailed Description Autoconfig assigns values to the network components. Recommended Response Action Disable Autoconfig and then modify the value. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC502 Message DHCP is required to be enabled on the NIC before DHCP can be \nenabled for DNS server or domain name objects. Detailed Description The value of the specified parameter cannot be changed.
Detailed Description The value of the specified parameter cannot be changed. Recommended Response Action Disable the cfgIPv6DNSServersFromDHCP6 object. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC505 Message The DNS domain name is not allowed to be configured if \ndomain name DHCP (cfgDNSDomainNameFromDHCP) is enabled. Detailed Description The value of the specified parameter cannot be changed.
Recommended Response Action Check if the NIC is disabled. If disabled, enable the NIC. Category System Health (NIC = NIC Config) Severity Severity 1 (Critical) No alerts are applicable for this message NIC508 Message NIC teaming info is not currently available. Detailed Description None. Recommended Response Action No response action is required.
Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC511 Message NIC is already ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC512 Message DHCP is already ENABLED Detailed Description Success message.
No alerts are applicable for this message NIC514 Message DHCP is now ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category System Health (NIC = NIC Config) Severity Severity 3 (Informational) No alerts are applicable for this message NIC515 Message DHCP6 is now ENABLED Detailed Description Success message. Recommended Response Action No response action is required.
OSD Event Messages OSD062 Message The process of installing an operating system or hypervisor is started and is in progress. Detailed Description The process of installing an operating system or hypervisor is started and is in progress. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC OSD064 Message The process of installing an operating system or hypervisor is abruptly stopped either by the user or the installation infrastructure. Detailed Description The process of installing an operating system or hypervisor is abruptly stopped either by the user or the installation infrastructure. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔ LCD OS Log Power Off Power Cycle CMC LC Log iDRAC ✔ Reset Chassis Event Proxy ✔ CMC OSD1 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration (OSD = OS Deployment) Severity Severity 3 (Informational) No alerts are applicable for this message OSD12 Message Cannot create the USB device needed to copy drivers for the selected operating system. Detailed Description iDRAC was unable to create and expose the drivers as a USB device for the OS installation to proceed. Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and rerun the command.
Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and rerun the command. Category Configuration (OSD = OS Deployment) Severity Severity 1 (Critical) No alerts are applicable for this message OSD15 Message Mount network share failed - incorrect username or password. Detailed Description Unable to mount the network share using the credentials specified in the command because either the username or password is incorrect.
Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and rerun the command. Category Configuration (OSD = OS Deployment) Severity Severity 1 (Critical) No alerts are applicable for this message OSD18 Message Unable to locate the ISO image on the network share point. Detailed Description Unable to find the ISO file specified in the network share. Make sure that the correct ISO file path was entered into the command and that all other user credentials are correct.
Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and run the command. Category Configuration (OSD = OS Deployment) Severity Severity 1 (Critical) No alerts are applicable for this message OSD20 Message Unable to get size or label from Driver Pack for selected operating system. Detailed Description Unable to get the size or label for selected operating system from the Driver Pack present in Lifecycle Controller. The driver pack may be corrupt.
Recommended Response Action 1) Rerun the command. 2) Reset iDRAC Category Configuration (OSD = OS Deployment) Severity Severity 1 (Critical) No alerts are applicable for this message OSD23 Message Unable to continue with DetachISOImage - another command is in the process of exposing the ISO Image and booting to it. Detailed Description Cannot continue with DetachISOImage because another command is in the process of exposing the ISO image and booting to it.
Recommended Response Action Reset iDRAC to detach this device automatically. Category Configuration (OSD = OS Deployment) Severity Severity 1 (Critical) No alerts are applicable for this message OSD26 Message Unable to continue with BootToPXE - another command is running. Detailed Description Unable to continue with BootToPXE command because another process is using Lifecycle Controller.
Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD29 Message Driver Pack configuration file not found in Lifecycle Controller. The Driver Pack might be corrupt. Detailed Description Driver Pack configuration file not found in Lifecycle Controller. Driver Pack may be unusable. Recommended Response Action Update the Driver Pack using USC or DUP and then rerun the command.
No alerts are applicable for this message OSD31 Message Copying operating system drivers to network share failed Detailed Description Copying drivers for the selected operating system to network share failed. The share may be read-only or the Driver Pack present in Lifecycle Controller may be unusable. Recommended Response Action 1) Make sure that the network share has write permission. 2) Update the Driver Pack using USC or DUP and then rerun the command.
OSD34 Message Unable to continue with BootToPXE - ISO image is attached to the system. Detailed Description Unable to continue with BootToPXE command because the system has an ISO image attached. Detach the ISO image before continuing with BootToPXE. Recommended Response Action Run the DetachISOImage command and then run BootToPXE.
OSD37 Message ISO image size too large. Detailed Description ISO Image size is bigger than the available size in VFlash. Recommended Response Action 1) Use a smaller size ISO Image. 2) Format the VFlash using the iDRAC GUI, RACADM, or iDRAC configuration utility and then retry this command. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD38 Message Copying the ISO image from the network failed.
OSD4 Message Cannot access Lifecycle Controller Driver Pack partition. Detailed Description Driver Pack partition in Lifecycle Controller is not accessible. The Lifecycle Controller or the iDRAC might be unresponsive. Recommended Response Action Reset the iDRAC and rerun the command. If the command fails again, check if the iDRAC is functional and accessible on the system.
OSD42 Message Downloading ISO File to VFlash failed. Detailed Description There was an error while copying the ISO image from the network share to the VFlash. Recommended Response Action 1) Make sure the network connection is working. 2) Make sure the Dell VFlash doesnt have any hardware issues by accessing it through the iDRAC GUI. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD43 Message VFlash unavailable.
OSD45 Message Cannot delete ISO image from VFlash. Detailed Description The ISO Image present in VFlash is attached to the host system. The ISO Image cannot be deleted from VFlash. Recommended Response Action Execute DetachISOFromVFlash() before running DeleteISOFromVFlash() Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD46 Message VFlash in use.
OSD48 Message ISO Images of more than 4GB not supported. Detailed Description ISO Images of more than 4GB are not supported and cannot be copied to VFlash. Recommended Response Action Use an ISO that is smaller than 4GB. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD49 Message Disable RIPS mode to access VFlash. Detailed Description VFlash cannot be accessed because RIPS mode is enabled.
OSD50 Message Lifecycle Controller is in field service mode. Detailed Description Lifecycle Controller is in field service mode and needs to be updated before proceeding further. Recommended Response Action Install the Lifecycle Controller field services package using the iDRAC GUI. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD51 Message Reboot the system to run pending System Services Tasks.
OSD53 Message vFlash is write protected. Detailed Description vFlash is write protected.
OSD56 Message An ISO is already connected using Remote File Share (RFS). Detailed Description An ISO is already connected using Remote File Share (RFS). The connection might have been initiated from iDRAC GUI, racadm, or Remote Services API. Recommended Response Action Disconnect the Remote File Share (RFS) using iDRAC GUI, racadm, or Remote Services API and then retry the operation to connect the ISO again.
OSD59 Message Unable to disconnect from ISO using Remote File Share (RFS). Detailed Description Disconnecting ISO using Remote File Share (RFS) operation did not complete successfully. Recommended Response Action Reset iDRAC and retry the operation. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD6 Message Cannot allocate memory. Detailed Description Unable to dynamically allocate memory to perform the task.
OSD61 Message IP Address format is invalid. Detailed Description The IP Address format is invalid and cannot be validated. The specified IP address may not be a valid IPv4 or IPv6 address. Recommended Response Action Verify the IP address format and retry the operation. Category Configuration (OSD = OS Deployment) Severity Severity 2 (Warning) No alerts are applicable for this message OSD7 Message Unable to retrieve Lifecycle Controller handle.
OSD9 Message Failed to reboot the system using an IPMI command. Detailed Description Resetting the targeted server using the standard IPMI command has failed. Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and rerun the command.
OSE Event Messages OSE0000 Message A critical stop occurred during OS load. Detailed Description The system halted due to an exception during operating system load or operating system initialization.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC OSE0002 Message An OS graceful stop occurred. Detailed Description (IPMI sensor type 20h - offset 02h). Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC OSE0004 Message A soft shut-down initiated by platform event filter. Detailed Description A separate exception or status condition shutdown the operating system. (IPMI sensor type 20h - offset 04h).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1000 Message A: boot completed. Detailed Description The system OS has successfully booted from A: Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1002 Message C: boot completed. Detailed Description The system OS has successfully booted from C: Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC OSE1004 Message PXE boot completed. Detailed Description The system OS has successfully booted from the PXE server. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC OSE1006 Message Diagnostic boot completed. Detailed Description The system has successfully booted to diagnostics. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1008 Message CD-ROM boot completed. Detailed Description The system OS has successfully booted from the CD-ROM. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1010 Message ROM boot completed. Detailed Description The system has successfully booted to ROM. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC OSE1012 Message Boot completed. Detailed Description The system has successfully booted. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC CMC 866 ✔* Reset Chassis Event Proxy
PCI Event Messages PCI1300 Message A front panel diagnostic interrupt was detected. Detailed Description The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced. Recommended Response Action Reset the system to continue operation.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1304 Message An I/O channel check error was detected. Detailed Description None Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Recommended Response Action Reboot the system and update the component drivers. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1308 Message A PCI parity error was detected on a component at bus arg1 device arg2 function arg3 .
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PCI1310 Message A PCI system error was detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PCI1314 Message A bus correctable error was detected on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded.
Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PCI1319 Message A high-severity issue is detected in the SSD bay arg1 , Slot arg2 . Arguments arg1 = bay id, arg2 = slot id Detailed Description A high-severity issue was detected in the SSD bay identified in the message. Recommended Response Action Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrance of the issue.
Trap/EventID 2417 LCD Message Bus fatal error on bus device function . Power cycle system. Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1321 Message A high-severity issue is detected in a component of the bus arg1 , device 0, function arg2 .
Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description System performance may be degraded. The bus is not operating at maximum speed or width. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PCI1344 Message An I/O channel check error was detected. Detailed Description None Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message An I/O channel check error detected. Power cycle system.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1348 Message A PCI parity error was detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded, or system may fail to operate.
Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message PCI system error on slot .
PCI1356 Message A bus uncorrectable error was detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI1360 Message A bus fatal error was detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded, or system may fail to operate.
Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time.
PCI2001 Message The component at bus arg1 device arg2 function arg3 recovered from a fatal IO error. Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI2003 Message The component at slot arg1 recovered from a fatal IO error. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Update BIOS, BMC/iDRAC, and LOM firmware. If problem persists please contact customer support. Category System Health (PCI = PCI Device) Severity Severity 1 (Critical) Trap/EventID 2417 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3001 Message Device option ROM on embedded NIC was successfully updated.
PCI3002 Message Failed to program virtual MAC address on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If problem persists please contact customer support.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3004 Message Device option ROM on mezzanine card arg1 failed to support Link Tuning or FlexAddress. Arguments arg1 = number Detailed Description Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
Recommended Response Action No response action is required. Category System Health (PCI = PCI Device) Severity Severity 3 (Informational) Trap/EventID 2419 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3006 Message Failed to get Link Tuning or FlexAddress data from iDRAC.
PCI3007 Message Link Tuning or FlexAddress data successfully obtained. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PCI3009 Message PCIe is operating normally on a component at bus arg1 device arg2 function arg3 . Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description None Recommended Response Action No response action is required.
Trap/EventID Filter Visibility iDRAC 2418 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3011 Message The component at bus arg1 device arg2 function arg3 recovered from a non-fatal IO error. Arguments arg1 = bus, arg2 = device, arg3 = func Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Reset the system, if the problem persists reinstall processors. Category System Health (PCI = PCI Device) Severity Severity 2 (Warning) Trap/EventID 2418 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3013 Message The QuickPath Interconnect (QPI) width regained.
PCI3014 Message A non-fatal PCIe error detected on a component at slot arg1 . Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3016 Message Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress. Detailed Description Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, and mezzanine card firmware.
Category System Health (PCI = PCI Device) Severity Severity 3 (Informational) Trap/EventID 2419 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PCI3018 Message New PCI card(s) have been detected in the system. Fan speeds may have changed to add additional cooling to the cards.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PCI3019 Message A low-severity issue is detected in the SSD bay arg1 , Slot arg2 . Arguments arg1 = bay id, arg2 = slot id Detailed Description A low-severity issue was detected in the SSD bay identified in the message. Recommended Response Action Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrance of the issue.
Category System Health (PCI = PCI Device) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PCI5001 Message A PCIe card carrier containing a PCIe card is inserted in PCIe slot arg1 . Arguments arg1 = slot number Detailed Description A PCIe card carrier containing a PCIe card is present in the slot identified in the message.
Arguments arg1 = slot number Detailed Description A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slot identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* ✔* PCI5004 Message A power fault issue is detected in the PCIe adapter that was turned on in PCIe slot arg1 . Arguments arg1 = slot number Detailed Description The Chassis Management Controller (CMC) detected an issue in the PCIe adapter that was turned on in the slot identified in the message.
Severity Severity 1 (Critical) Trap/EventID 2417 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* PCI5006 Message The power-related issue of the PCIe adapter in slot arg1 is resolved.
Detailed Description The 3.3 Volt Regulator power related issue of PCIe carrier present in the slot identified in the message is resolved. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* ✔* PCI5009 Message The PCIe adapter in the PCIe slot arg1 was removed from the slot while the server arg2 was turned-on. Arguments arg1 = PCIe slot number, arg2 = server slot number Detailed Description Chassis Management Controller (CMC) detected that a PCIe adapter was removed from a server which was turned-on.
PDR Event Messages PDR1 Message arg1 copyback stopped for rebuild. Arguments arg1 = physical disk Detailed Description This message is generated after a copyback stops on a physical disk during a rebuild operation. Recommended Response Action Wait for rebuild to finish, then copyback should resume.
Trap/EventID 4347 OMSA Event ID 2065 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR100 Message Dedicated Hot Spare arg1 no longer useful for all arrays. Arguments arg1 = PD Name Detailed Description The controller is not able to communicate with a disk that is assigned as a dedicated hot spare.
PDR1000 Message Drive arg1 is installed in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR1002 Message A predictive failure detected on drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description The controller received a SMART error from the drive. The drive is operational but needs replacement.
Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1004 Message Consistency check is in progress for drive arg1 in disk drive bay arg2 .
Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) LCD Message Drive in disk drive bay is in the critical array. Replace drive.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PDR1007 Message Rebuild is in progress for drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR101 Message Global Hot Spare arg1 does not cover all arrays. Arguments arg1 = PD Name Detailed Description This alert message occurs if there are arrays not protected with a global hot spare. Recommended Response Action No response action is required.
Detailed Description The controller detected that the drive was removed. Recommended Response Action Verify drive installation. Remove and reseat the failed drive. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 2297 LCD Message Drive removed from disk drive bay . Check drive.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR1019 Message Drive arg1 in disk drive bay arg2 is no longer the hot-spare drive. Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR1020 Message Consistency check for drive arg1 in disk drive bay arg2 completed. Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Category System Health (PDR = Physical Disk) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1022 Message Drive arg1 in disk drive bay arg2 is no longer in the failed array. Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1024 Message Drive mismatch detected for drive arg1 in disk drive bay arg2 .
PDR1025 Message Drive mismatch corrected for drive arg1 in disk drive bay arg2 . Arguments arg1 = number, arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PDR104 Message The arg1 has turned off because the critical temperature threshold is exceeded. Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message has turned off because the critical temperature threshold of the device was exceeded.
Recommended Response Action No response action is required. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR106 Message The physical disk drive arg1 is unassigned as a dedicated hot-spare.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR107 Message The physical disk drive arg1 is assigned as a global hot-spare. Arguments arg1 = physical disk drive name Detailed Description The physical disk drive identified in the message is assigned as a global hot-spare. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Assigning a new global hot spare is recommended. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR11 Message arg1 rebuild was cancelled.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR110 Message The arg1 reliability has degraded. Arguments arg1 = PCIe solid state device name Detailed Description The reliability of the PCIe solid state device identified in the message degraded. Data loss is possible. Recommended Response Action Back up the data on the device, and contact your service provider for further instructions.
Trap/EventID Filter Visibility iDRAC 2299 IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR1101 Message Fault detected on drive arg1 . Arguments arg1 = number Detailed Description The controller detected a failure on the disk and has taken the disk offline. Recommended Response Action Remove and reseat the failed disk.
Detailed Description The controller received a SMART error from the drive. The drive is operational but needs replacement. Recommended Response Action The drive will need replacement at the next service window.
PDR1104 Message Consistency check is in progress for drive arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1105 Message Drive arg1 is in the critical array.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PDR1106 Message Drive arg1 is in the failed array. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health (PDR = Physical Disk) Severity Severity 1 (Critical) LCD Message Drive is in the failed array. Replace drive.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1108 Message Rebuild was aborted for drive arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) OMSA Event ID 2443 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PDR1116 Message Drive arg1 is removed. Arguments arg1 = number Detailed Description The controller detected a drive removal Recommended Response Action If unintended, verify drive installation.
PDR1117 Message Drive arg1 is operating normally. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PDR112 Message The arg1 has reached arg2 of warranted device wear-out limit. Arguments arg1 = PCIe solid state device name, arg2 = percent Detailed Description The PCIe solid state device identified in the message is approaching the warranted wear-out limit. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1121 Message Drive arg1 is no longer in the critical array. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Category System Health (PDR = Physical Disk) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PDR1123 Message Rebuild completed for drive arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Back up the data on the device, and contact your service provider for further instructions. Category Storage (PDR = Physical Disk) Severity Severity 2 (Warning) Trap/EventID 4346 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR114 Message The arg1 is approaching read-only mode.
PDR115 Message The arg1 is in read-only mode. Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is in read-only mode. Recommended Response Action Back up the data on the device, and contact your service provider for further instructions.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PDR117 Message The arg1 has turned off because the critical temperature threshold is exceeded. Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message has turned off because the critical temperature threshold of the device was exceeded.
Recommended Response Action Replace the failed or corrupt disk. Identify a disk that has failed by locating the disk that has a red "X" for its status. Restart the initialization.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR14 Message arg1 initialization is complete. Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 4347 OMSA Event ID 2092 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR16 Message Predictive failure reported for arg1 . Arguments arg1 = physical disk Detailed Description The physical disk is predicted to fail.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR17 Message Global hot spare assigned to arg1 . Arguments arg1 = PD Name Detailed Description A user has have assigned a physical disk as a global hot spare. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Although this alert is provided for informational purposes, you may need to assign a new hot spare to the virtual disk. See Protecting Your Virtual Disk with a Hot Spare for more information.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR2 Message Insufficient space available on arg1 to perform a copyback operation. Arguments arg1 = physical disk Detailed Description This message is generated if a physical disk does not have enough space to do a copyback operation. Recommended Response Action Replace the physical disk with a larger physical disk, and then restart the copyback operation.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 4345 OMSA Event ID 2107 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR206 Message arg1 is a solid state drive (SSD) that is not supported by the controller.
PDR207 Message Unable to assign arg1 as a dedicated hot spare. Arguments arg1 = physical disk name Detailed Description Unable to assign the physical disk as a dedicated hot spare because the selected disk size does not meet the size requirements of the target Virtual Disk. Recommended Response Action Select a physical disk that matches the size required for the disks used in the target Virtual Disk, and retry the operation.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR209 Message The power status of arg1 is changed from arg2 to arg3 . Arguments arg1 = physical disk name, arg2 = previous power status, arg3 = current power status Detailed Description The Manage Physical Disk Power feature is enabled for physical drives and the power status of the drives changed.
Detailed Description A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR211 Message arg1 has encountered storage medium error. Arguments arg1 = physical disk name Detailed Description Storage medium error was detected on the disk identified in the message. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) OMSA Event ID 2425 OMSA Trap ID 90100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR213 Message The state of arg1 changed from Non-RAID to Ready.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR214 Message The arg1 is not supported because it is not supplied by an authroized hardware provider. Arguments arg1 = physical disk name Detailed Description The physical disk identified in the message is not compliant with the standards set by the hardware provider and is not supported.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) OMSA Event ID 2183 OMSA Trap ID 90400 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PDR22 Message SMART warning temperature for arg1 Arguments arg1 = PD Name Detailed Description A disk has reached an unacceptable temperature and received a SMART alert (predictive failure).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR23 Message SMART warning degraded for arg1 Arguments arg1 = PD Name Detailed Description A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert.
Detailed Description A disk has received a SMART alert (predictive failure) due to test conditions. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR26 Message arg1 is online. Arguments arg1 = physical disk Detailed Description A drive has entered the online state. This may be because the system just started or could be because a problem with the drive has been corrected. Recommended Response Action No response action is required.
Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 OMSA Event ID 2160 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR28 Message Dedicated hot spare unassigned from arg1 .
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR29 Message Rebuild on arg1 completed with error(s). Arguments arg1 = PD Name Detailed Description See A Rebuild Completes with Errors for more information. Recommended Response Action See A Rebuild Completes with Errors for more information.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 4345 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR30 Message A global hot spare failed. arg1 Arguments arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare.
PDR31 Message A global hot spare has been removed. arg1 Arguments arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable. Recommended Response Action Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables.
Severity Severity 2 (Warning) Trap/EventID 4346 OMSA Event ID 2203 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR33 Message A dedicated hot spare has been removed. arg1 Arguments arg1 = PD Name Detailed Description The controller cannot to communicate with a disk that is assigned as a global hot spare.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR34 Message A dedicated hot spare has been automatically unassigned. arg1 Arguments arg1 = PD Name Detailed Description The hot spare is no longer required because the virtual disk it was assigned to has been deleted. Recommended Response Action No response action is required.
Recommended Response Action Add a SAS disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PDR37 Message The arg1 is not supported. Arguments arg1 = physical device Detailed Description The physical device may not have a supported version of the firmware or the physical device may not be supported. Recommended Response Action If the physical device is supported, then update the firmware to a supported version.
Severity Severity 3 (Informational) Trap/EventID 4347 OMSA Event ID 2249 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR39 Message A blink operation has initiated on arg1 . Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes.
PDR4 Message arg1 returned to a ready state. Arguments arg1 = physical disk Detailed Description A physical drive that was previously in an error state has returned to a ready state. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR41 Message The clear operation on arg1 was cancelled. Arguments arg1 = physical disk Detailed Description The clear command did not complete on the physical disk. This means that some data was not cleared and may be recoverable. Recommended Response Action No response action is required.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR44 Message The clear operation on arg1 failed. Arguments arg1 = physical disk Detailed Description A Clear task was being performed on a physical disk but the task was interrupted and did not complete successfully. The controller may have lost communication with the disk, the disk was removed, or the cables may be loose or defective.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 4345 OMSA Event ID 2272 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR47 Message A block on arg1 was punctured by the controller.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR48 Message The arg1 rebuild has resumed. Arguments arg1 = physical disk Detailed Description This message is generated after rebuild resumes on a physical disk. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 4346 OMSA Event ID 2276 OMSA Trap ID 90300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR5 Message arg1 is removed. Arguments arg1 = PD Name Detailed Description A physical disk has been removed from the disk group.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR50 Message Insufficient space on the global hot spare arg1 . Arguments arg1 = PD Name Detailed Description The global hot spare is not large enough to protect all virtual disks that reside on the controller. Recommended Response Action Assign a larger disk as the global hot spare.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 4345 OMSA Event ID 2282 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR52 Message A redundant path is broken. Detailed Description The controller has two connectors that are connected to the same enclosure.
PDR53 Message A redundant path has been restored for arg1 . Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 90100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR55 Message Insufficient space available on the arg1 to perform a rebuild. Arguments arg1 = physical disk Detailed Description The physical disk inserted is too small for the rebuild to occur.
Arguments arg1 = physical disk Detailed Description The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which means that disk errors are no longer corrected. At this point, data loss can occur. The bad block table is now 80 percent full. Recommended Response Action Replace the disk generating this message.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR58 Message arg1 is incompatible. Arguments arg1 = PD Name Detailed Description A user attempted to replace a disk with another disk that is using an incompatible technology.
Detailed Description The disk has a bad block. Data was remapped to another disk block. No data loss has occurred. Recommended Response Action Monitor the disk for other messages or indications of poor health.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR60 Message Error occurred on arg1 : arg2 . Arguments arg1 = physical disk, arg2 = error code Detailed Description The reason for the error can vary depending on the situation. The firmware error code is indicated in the message. Recommended Response Action Verify the health of attached devices. Review the Lifecycle log for significant events. Replace faulty hardware, if required.
Category Storage (PDR = Physical Disk) Severity Severity 1 (Critical) Trap/EventID 4345 OMSA Event ID 2347 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR62 Message The rebuild failed due to errors on the target arg1 .
PDR63 Message A bad disk block on arg1 cannot be reassigned during a write operation. Arguments arg1 = physical disk Detailed Description A write operation cannot complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred. Data redundancy may be lost. Recommended Response Action Replace the disk.
OMSA Event ID 2350 OMSA Trap ID 90400 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR65 Message arg1 is marked as missing. Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
PDR66 Message arg1 that was marked as missing has been replaced. Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR68 Message Dedicated spare arg1 imported as global due to missing disk groups. Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes Recommended Response Action No response action is required.
Detailed Description Physical disk inserted is of the incorrect protocol. SAS or SATA mixing is not supported in the same virtual disk. Recommended Response Action Remove drive, insert correct protocol type, and force a rebuild as imposed for controller and system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR70 Message Copyback started from arg1 to arg2 . Arguments arg1 = physical disk, arg2 = physical disk Detailed Description A copyback operation began to copy data from one physical disk to another physical disk. This may be due to a user initiated operation or a predictive failure.
Detailed Description The copyback operation completed. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR73 Message Copyback failed from arg1 to arg2 . Arguments arg1 = physical disk, arg2 = physical disk Detailed Description The physical disk participating in the copyback operation failed. Recommended Response Action Replace the disk and retry the operation.
OMSA Event ID 2184 OMSA Trap ID 90100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* PDR75 Message Copyback stopped for hot spare arg1 . Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes Recommended Response Action No response action is required.
PDR76 Message Copyback not possible as SAS or SATA mixing is not supported. Detailed Description Copyback not possible as SAS or SATA mixing is not supported in the same virtual disk. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ iDRAC ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR78 Message arg1 state changed from Non-RAID to READY. Arguments arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action Re-issue the command. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR8 Message arg1 is inserted. Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PDR81 Message Microcode update started on arg1 . Arguments arg1 = physical disk Detailed Description The physical disk firmware update operation has started. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR83 Message arg1 is reprovisioned. Arguments arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR85 Message Security subsystem errors detected for arg1 .
PDR86 Message Bad block table on arg1 is full. Arguments arg1 = physical disk Detailed Description The number of blocks on the disk that exhibit an error has exceeded the capacity of the drive to remap. Any future writes to bad sectors will be unrecoverable. Recommended Response Action Replace the disk.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR88 Message Power state change failed on arg1 . (from arg2 to arg3 ) Arguments arg1 = PD Name, arg2 = state, arg3 = state Detailed Description When physical drives in spun down power state are configured, the drives should transition to spun up power state..
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC ✔* PDR93 Message Microcode update on arg1 has completed. Arguments arg1 = physical disk Detailed Description The physical disk firmware update operation has completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR95 Message Microcode update on arg1 has failed. Arguments arg1 = physical disk Detailed Description The attempt to update the physical disk has failed. This is due to too much activity on the bus, a bad update package, or a bad disk.
Recommended Response Action No response action is required. Category Storage (PDR = Physical Disk) Severity Severity 3 (Informational) Trap/EventID 4347 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* PDR97 Message arg1 security key required.
PDR98 Message Command timeout occurred on arg1 . arg2 . Arguments arg1 = physical disk, arg2 = args Detailed Description An error occurred while performing an action on the disk. Recommended Response Action Check the disk is present or replace the disk.
PFM Event Messages PFM0001 Message The value of arg1 is greater than the upper critical threshold. Arguments arg1 = sensor name Detailed Description The utilization value of the sensor identified in the message is higher than the upper critical threshold. Recommended Response Action Check the work load of the server and reduce the workload if necessary to bring the system performance into required ranges.
PFM0003 Message The value of arg1 is less than the lower warning threshold. Arguments arg1 = sensor name Detailed Description The utilization value of the sensor identified in the message is lower than the lower warning threshold value. Recommended Response Action The workload on server is almost zero. Consider assigning additional workloads to the server.
POW Event Messages POW000 Message Power on permission error, chassis infrastructure not ready. Detailed Description Host failed to power up bacause chassis infrastructure is not ready. This messages has been replaced by Message ID PWR2250 Recommended Response Action Check status of chassis infrastructure.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC POW002 Message Power on permission error, unknown component installed in Fabric1/Fabric2. Detailed Description Host failed to power up because unsupported components installed in Fabric1/ fabric2.This messages has been replaced by Message ID PWR2252 Recommended Response Action Check for unsupported components installed in Fabric1/Fabric2.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC POW004 Message Power on permission error, unacknowledge use of 110V. Detailed Description Host failed to power up because of unacknowledged use of 110V. This messages has been replaced by Message ID PWR2254 Recommended Response Action Check for unacknowledged use of 110V.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC 1003
PR Event Messages PR1 Message A replacement part was detected for device: arg1 Arguments arg1 = device name Detailed Description The specified device has been replaced. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR11 Message A required license for the Part Replacement feature is not present, replacement action(s) will not be performed. Detailed Description A valid license for this feature is not present.
Category Configuration (PR = Part Exchange) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR13 Message Firmware mismatch detected. Configuration changes not applied. Detailed Description The Part Replacement feature detected a firmware difference and cannot apply the configuration changes.
Recommended Response Action Check the current system configuration and retry the operation.
Arguments arg1 = device name Detailed Description The device could not apply some of the configuration settings. This may indicate configuration changes since the last system inventory or mutually exclusive settings. Recommended Response Action Check the current system configuration and ensure all settings are correct. If not, retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR18 Message Firmware version difference detected for device: arg1 Arguments arg1 = device name Detailed Description The Part Replacement feature has detected a firmware difference between the current and previous components. Depending on the Part Firmware Update setting value this may cause a firmware update to the replaced part. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR2 Message Configuration difference detected for device: arg1 Arguments arg1 = device name Detailed Description The specified device configuration is different from the previous device configuration. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR21 Message Job failed. Detailed Description The specified job did not complete successfully. Recommended Response Action Check the Lifecycle Log for more details associated with this failure then retry the operation.
Category Configuration (PR = Part Exchange) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR23 Message Job is ready for execution. Detailed Description The specified job is ready to start. It is waiting for scheduling from job control. This message is no longer in use in Lifecycle Controller 2.
Recommended Response Action No response action is required. Category Configuration (PR = Part Exchange) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR25 Message Missing or corrupt configuration database. Detailed Description The systems configuration database is missing or is unreadable.
Detailed Description The configuration data associated with the specified job could not be located. Recommended Response Action Retry the operation. If this issue persists, contact technical support. Category Configuration (PR = Part Exchange) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR27 Message Unable to allocate resources.
PR28 Message Unable to locate device in current configuration. Detailed Description The device that the job was intended for is no longer detected. This could be due to the device being removed, disabled, or a failure. Recommended Response Action If the device was removed, reinsert the device and retry the operation. If the device was disabled, re-enable the device and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR3 Message Newer version of firmware found on device: arg1 Arguments arg1 = device name Detailed Description The current component firmware version is higher than the replaced component firmware version. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR31 Message Job completed with errors. Detailed Description All the tasks in the Job were attempted, but some did not complete successfully. Recommended Response Action Check the Lifecycle Log for more details associated with this warning then retry the operation if appropriate.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR33 Message Motherboard replacement detected. Detailed Description The platform system motherboard was replaced. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR35 Message Power Supply slot arg1 firmware update will be performed during next system reboot.
Detailed Description The system has detected a different firmware version than previously recorded for the indicated device. This may be due to a firmware update, rollback, or part replacement. Recommended Response Action No response action is required.
PR5 Message The configuration values stored for the previous device could not be applied to device: arg1 Arguments arg1 = device name Detailed Description Some or all configuration values stored for the previous device could not be applied to the current device. This may be due to firmware version or other differences in the part. Recommended Response Action Check the devices configuration and ensure that the new configuration is correct for the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PR7 Message New device detected: arg1 Arguments arg1 = device name Detailed Description The specified device was added to the system. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PR9 Message Firmware update operation initiated. Detailed Description The Part Replacement feature started the firmware update process based on Part Firmware Update attribute settings. Recommended Response Action No response action is required.
PST Event Messages PST0000 Message Unrecognized Post Code. Detailed Description The BIOS provided a progress code to the iDRAC, but that progress code is not recognized by the current iDRAC firmware. Recommended Response Action Do one of the following: 1) Update the iDRAC firmware. 2) Restart the system and retry the operation. If the issue persists, contact your service provider. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Unrecognized Post Code.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0002 Message CPU Microcode load. Detailed Description System BIOS has started loading the processor microcode. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message CPU Microcode load.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0004 Message Memory Configuration. Detailed Description System BIOS has started memory configuration. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Memory configuration started.
Severity Severity 3 (Informational) LCD Message Shadow BIOS operation started. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0006 Message Multiprocessor Initialization. Detailed Description System BIOS has started initialization multiprocessor support. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Started power on self test (POST). Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0008 Message System Management Mode (SMM)initialization.
PST0009 Message PCI bus enumeration & video initialization. Detailed Description System BIOS has started PCI bus enumeration and video initialization. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message PCI bus enumeration & video initialization.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0011 Message Extended Memory test started. Detailed Description System started extended memory test. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Extended memory test started.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0013 Message Extended Memory test running / Detailed Description System extended memory test in progress. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) LCD Message Extended Memory test completed. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0064 Message Display sign-on. Detailed Description System BIOS is displaying power on splash screen. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message PCI configuration. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0080 Message An issue was detected. System at boot F1/F2 prompt. Requires entry to continue.
PST0081 Message No bootable devices. Detailed Description System is at F1/F2 prompt because the system BIOS was unable to detect a bootable device. Recommended Response Action Make sure a bootable device is attached to the system and enabled in BIOS setup. If device is attached and enabled, remove and reapply power to server. If the problem persists, contact your service provider. Refer to the product documentation to choose a convenient contact method.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0083 Message In BIOS Boot Menu. Detailed Description System is at the BIOS Boot Menu. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message In BIOS Boot Menu.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0085 Message Performing CSIOR. Detailed Description System is performing CSIOR (Collect System Inventory on Restart). Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Performing CSIOR.
Severity Severity 3 (Informational) LCD Message In Lifecycle Controller. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0087 Message Initializing iDRAC. Detailed Description System BIOS is initializing iDRAC. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Preparing to Boot. Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0089 Message A problem was detected during Power-On Self-Test (POST).
Detailed Description A problem was detected related to the previous server boot. The next logged message contains more specific details for the detected issue. Recommended Response Action Review the next logged message for the recommended response action to resolve the problem.
PST0126 Message Giving control to UEFI aware OS. Detailed Description System is currently booting to an UEFI compatible operating system. No more POST codes will be generated in this boot sequence. Recommended Response Action No response action is required. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Giving control to UEFI aware OS.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PST0128 Message No memory is detected. Detailed Description System BIOS was unable to detect memory in the system . This exception occurred early in system power on, thus the system may not display video (BIOS Post Exception 80). Recommended Response Action Inspect System Memory. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message No memory is detected.
Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Memory is detected, but is not configurable. Check memory devices Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0130 Message Memory is configured, but not usable.
PST0131 Message System BIOS shadow failed. Detailed Description Memory errors occurred copying BIOS image into system memory. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception Code 83) Recommended Response Action Remove input power. Reduce system memory to minimum configuration and apply input power. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) LCD Message System BIOS shadow failed.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0133 Message DMA controller failed. Detailed Description System BIOS detected a failure with the DMA controller during system POST. This exception occurred early in system power on, thus the system may not display video.
Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Interrupt controller failed.
PST0136 Message Programmable interval timer error. Detailed Description System BIOS detected an failure with the programmable interval timer during POST. This exception occurred early in system power on, thus the system may not display video.(BIOS POST Exception code 88) Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0138 Message SuperIO failed. Detailed Description System BIOS detected a failure with the SIO. This exception occurred early in system power on, thus the system may not display video. (BIOS POST code exception code 8A) Recommended Response Action Remove and reapply input power.
Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Keyboard controller failed.
PST0141 Message QuickPath Interconnect (QPI) fatal error. Detailed Description Quick Path Interconnect failed during system POST. Reboot the system. If problem persists, remove input power and reseat processors. This exception occurred early in system power on, thus the system may not display video. Recommended Response Action Reboot the system. If problem persists, remove input power and reseat processors.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0143 Message Intel Trusted Execution Technology (TXT) fatal error. Detailed Description TXT boot failed. This could be related to memory errors or an error with the system TXT configuration. A socketed TPM module may have been removed.
Recommended Response Action Remove and reapply power to server. If the problem persists, contact your server provider. Refer to the product documentation to choose a convenient contact method. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) LCD Message Unable to load required BIOS files.
PST0193 Message BIOS POST memory test failed. Detailed Description System BIOS POST memory test failed. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C1) Recommended Response Action Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0195 Message CPU configuration failed. Detailed Description The current processor configuration is unsupported or encountered a fatal exception during POST. Check the processor configuration. This exception occurred early in system power on, thus the system may not display video.
Recommended Response Action Re-install memory to match supported memory configuration. Category System Health (PST = BIOS POST) Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Incorrect memory configuration. Review User Guide Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0208 Message System BIOS has halted.
PST0209 Message System BIOS has halted due to Non-Maskable Interrupt (NMI). Detailed Description System BIOS has halted and is unable to continue. System BIOS has detected a Non-Maskable Interrupt (NMI) which may have been caused by a hardware change. Recommended Response Action Do one of the following: 1) If new hardware has been added, remove the new hardware and restart the server, 2) Turn server off and back on using the power button, or 3) Remove and reapply server input power.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PST0256 Message POST fatal error detected. Detailed Description System BIOS detected a functional or configuration issue during system POST. Check the system video screen for more information. The system event log may contain additional details.
PSU Event Messages PSU0000 Message Power supply arg1 is present. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
OMSA Event ID 5300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy PSU0002 Message A predictive failure detected on power supply arg1 . Arguments arg1 = number Detailed Description System performance and power redundancy may be degraded or lost.
Detailed Description The power supply is installed correctly but an input source is not connected or is not functional. Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Power input for PSU is lost.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy PSU0005 Message The power input for power supply arg1 is outside of the allowable range, but it is attached to the system. Arguments arg1 = number Detailed Description The operating requirements for the power supply may be found in product documentation or on the power supply itself. Recommended Response Action Verify the input power is within the operating requirements for the power supply.
Recommended Response Action Review server product documentation for supported power supplies and power supply configurations. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Power supply is incorrectly configured. Check PSU.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy PSU0017 Message Power supply arg1 is operating normally. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 2187 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ PSU0022 Message Power supply arg1 is correctly configured. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔* IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy PSU0031 Message Cannot communicate with power supply arg1 .
PSU0032 Message The temperature for power supply arg1 is in a warning range. Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* PSU0034 Message An under voltage fault detected on power supply arg1 . Arguments arg1 = number Detailed Description This failure may be the result of an electrical issue with cables or subsystem components in the system.
Detailed Description None Recommended Response Action Check input power, replace or re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Over voltage fault on PSU .
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* PSU0037 Message Fan failure detected on power supply arg1 . Arguments arg1 = number Detailed Description None Recommended Response Action Check for fan blockage. If not replace the power supply. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Fan failure detected on PSU . Check PSU.
Trap/EventID 2187 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* PSU0039 Message An under current fault detected on power supply arg1 . Arguments arg1 = number Detailed Description Insufficient amount of current to keep power supply operating at a normal levels.
Detailed Description The power supply output voltage is insufficient to keep system operating at a normal levels. Recommended Response Action 1) Remove the power supply input cord and then remove power supply. 2) Reinstall the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* PSU0042 Message An output over current fault detected on power supply arg1 . Arguments arg1 = number Detailed Description none Recommended Response Action 1) Remove the power supply input cord and then remove power supply. 2) Reinstall the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support.
Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Output under current fault detected on PSU . Check PSU. Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* PSU0044 Message Cannot obtain status information from power supply arg1 .
PSU0045 Message Power supply arg1 status information successfully obtained. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* PSU0076 Message A power supply wattage mismatch is detected; power supply arg1 is rated for arg2 watts. Arguments arg1 = number, arg2 = value Detailed Description Power supplies should be of the same input type and power rating.
Detailed Description Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* PSU0080 Message Power supply arg1 voltage rating does not match the systems requirements. Arguments arg1 = number Detailed Description The system does not support mixed voltage power supplies. Recommended Response Action Review product documentation, change power supply with correct voltage rating.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* PSU0091 Message Power supply unit arg1 rating exceeds the system power distribution limits. Arguments arg1 = PSU number Detailed Description The rating of the power supply unit identified in the message should not exceed system power distribution limits.
Detailed Description The rating of the power supply unit identified in the message does not exceed system power distribution limits. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PSU0801 Message Power Supply arg1 : CRC error detected Arguments arg1 = PSU_Name Detailed Description The Power Supply had a CRC error detected Recommended Response Action Aquire the power supply firmware image and update the power supply indicated in the message.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0803 Message Insufficient power in chassis to power on server. Detailed Description Insufficient power in chassis to power on server. Recommended Response Action Utilize the Chassis Management Controller web interface to check available power and server power requirements.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0901 Message Power unit arg1 is on. Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0904 Message Could not power down 240VA on power unit arg1 .
Arguments arg1 = number Detailed Description In order to meet service requirements the supply must be shut down. Recommended Response Action Remove input power at the power supply.
PSU0908 Message Power lost on power unit arg1 . Arguments arg1 = number Detailed Description The power supply is installed correctly but an input source is not connected or is not functional. Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0910 Message Soft power control failure detected on power unit arg1 . Arguments arg1 = number Detailed Description The system did not respond correctly to a power down request.
Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0912 Message A failure detected on power unit arg1 . Arguments arg1 = number Detailed Description Status from the power supply indicates a power supply exception occurred. The power supply will try to operate in a degraded state.
Arguments arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PSU0914 Message A predictive failure detected on power unit arg1 .
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PSU100 Message Power supply arg1 is offline. Arguments arg1 = power supply unit Detailed Description The power supply unit identified in the message is offline, because of the one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Severity Severity 2 (Warning) Trap/EventID 4234 OMSA Event ID 2312;2313 OMSA Trap ID 100300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* PSU1001 Message arg1 has failed. Arguments arg1 = PSU Sensor Name Detailed Description The enclosure detected that a power supply unit has failed.
PSU1002 Message arg1 was removed Arguments arg1 = PSU Sensor Name Detailed Description The enclosure detected that a power supply unit was removed and is no longer functioning in optimal condition. Recommended Response Action Re-insert the power supply unit into the enclosure. Re-connect the AC power cable and switch on the power supply unit. Contact technical support if the issue persists.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* PSU1004 Message Power supply cable has been inserted into arg1 . Arguments arg1 = PSU Sensor Name Detailed Description The enclosure detected that AC power supply was restored to the power supply unit. Recommended Response Action No response action is required.
Detailed Description The enclosure detected that a power supply unit was switched on. Recommended Response Action No response action is required. Category Storage (PSU = Power Supply) Severity Severity 3 (Informational) Trap/EventID 4235 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* PSU1006 Message arg1 was inserted.
PSU1007 Message arg1 has failed. Arguments arg1 = PSU Sensor Name Detailed Description A device has been failed and the system is no longer functioning in optimal condition. Recommended Response Action Replace the device.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PSU1010 Message The DC power supply is switched off. Detailed Description The power supply unit is switched off. Either you have switched off the power supply unit or it is defective. Recommended Response Action Check to see whether the power switch is turned off or on. If it is turned off, turn it on.
Recommended Response Action Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input power supply.
PSU500 Message Unable to get the current server power status. Detailed Description Racadm tool cannot obtain the power status possible reason is that the IPMI call failed. Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 1 (Critical) No alerts are applicable for this message PSU501 Message Server is already powered ON. Detailed Description The server was already up, when the user gave a power on request.
PSU503 Message Server power status: arg1 Arguments arg1 = Status Detailed Description Success message. Recommended Response Action No response action is required. Category System Health (PSU = Power Supply) Severity Severity 3 (Informational) No alerts are applicable for this message PSU504 Message Server power operation successful Detailed Description Success message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PSU8502 Message The PSU in slot arg1 detected 110 VAC input voltage and does not match chassis configuration. Arguments arg1 = slot number Detailed Description The input voltage of the PSU specified in the message does not match the input voltage of the PSUs already present in the chassis.
Recommended Response Action Do the following: 1) Check if the input voltage of all the PSUs are the same. 2) If the input voltage of the PSU specified in the message is not the same, then remove the unmatched PSU.
Detailed Description Unable to set the chassis redundancy policy to AC Redundancy. Recommended Response Action Retry the operation using the CMC command line interface or CMC Web interface. To set the chassis redundancy policy using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1". To configure the chassis redundancy policy using the Web interface, click Chassis Overview > Power > Configuration. From the Redundancy drop-down menu, select AC Redundancy.
PSU8507 Message Insufficient power available because PSU in the slot arg1 is not present.. Arguments arg1 = slot number Detailed Description The PSU identified in the message has been disengaged or removed. Insufficient power is available. Recommended Response Action Insert a PSU in the slot identified in the message.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PSU8510 Message PSU in slot arg1 FW updated successfully to version arg2 Arguments arg1 = slot number, arg2 = version number Detailed Description The firmware for the PSU identified in the message is successfully updated to the version displayed in the message Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy ✔* PSU8512 Message Unable to update the firmware for the PSU in slot arg1 .
Recommended Response Action Retry the firmware update operation. If the problem persists, contact your service provider.
PSU8516 Message Unable to set redundancy policy because PSU enumeration is in progress. Detailed Description Unable to set redundancy policy because PSU enumeration is in progress. The policy can be set after PSU enumeration is complete. Recommended Response Action Retry the operation after the PSU enumeration is complete.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PSU8518 Message Unable to access the PSU arg1 FRU data. Arguments arg1 = slot number Detailed Description The operation to read the FRU data from the PSU identified in the message did not complete successfully due to internal communication errors. Recommended Response Action Retry the operation. If the condition persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PSU8520 Message Enhanced Dynamic Power Supply Engagement (DPSE) is fully supported. Detailed Description The Dynamic Power Supply Engagement feature is supported and fully operational. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 8329 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* 1108 LCD Reset Chassis Event Proxy ✔* ✔*
PSUA Event Messages PSUA0016 Message Power supply arg1 is absent. Arguments arg1 = number Detailed Description The supply has been removed or has failed. Recommended Response Action Install the power supply if needed. Category System Health (PSUA = PSU Absent) Severity Severity 1 (Critical) Trap/EventID 2465 LCD Message PSU is absent.
PWR Event Messages PWR0100 Message The power button was pressed. Detailed Description None Recommended Response Action No response action is required. Category System Health (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR0101 Message The power button was released.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0102 Message The sleep button was pressed. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0104 Message The reset button was pressed. Detailed Description The system will reset. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR0106 Message The arg1 is latched. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR0108 Message The arg1 service was requested. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR1000 Message The system performance restored. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Review system configuration and power consumption. Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Trap/EventID 2274 LCD Message System performance degraded.
PWR1003 Message The system performance degraded because cooling capacity has changed. Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action If unintended, review system configuration changes and thermal policy.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC PWR1005 Message The system performance degraded because of user-defined power capacity has changed. Detailed Description To avoid exceeding the user defined capacity, system performance has been degraded. Recommended Response Action If unintended, review system configuration changes and power policy.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC PWR1007 Message The system performance degraded because power exceeds capacity. Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action Review system configuration, upgrade power supplies or reduce system power consumption.
Recommended Response Action Review system configuration, upgrade power supplies or reduce system power consumption. Category System Health (PWR = Power Usage) Severity Severity 1 (Critical) Trap/EventID 2273 LCD Message System power exceeds threshold. Performance degraded.
PWR200 Message Enabling the Max Power Conservation Mode (MPCM) feature will disable the Extended Power Performance (EPP) feature. Detailed Description Enabling the Max Power Conservation Mode (MPCM) feature will disable the Extended Power Performance (EPP) feature. MPCM forces servers in to a lowpower and limited-performance mode, and then disables the ability to turn on additional servers. Recommended Response Action No response action required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2001 Message The system hard reset. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2003 Message User requested a PXE boot. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2005 Message The OS run-time software initiated a hard reset. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2007 Message System restarted. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR202 Message Enabling the Max Power Conservation Mode (MPCM) feature forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Recommended Response Action Enter a Power cap value greater than 13300 W, and then retry the operation. Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR204 Message Object value is successfully modified. Max Power Conservation Mode will deactivate the Extended Power Performance feature.
Detailed Description The Server Performance Over Power Redundancy (SPOPR) feature cannot be enabled because the Extended Power Performance is enabled. Recommended Response Action Disable Extended Power Performance and retry the operation.
PWR207 Message The Dynamic Power Supply Engagement (DPSE) feature cannot be enabled because the Extended Power Performance mode is enabled. Detailed Description The Dynamic Power Supply Engagement (DPSE) feature cannot be enabled because the Extended Power Performance mode is enabled. Recommended Response Action Disable Extended Power Performance and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR210 Message The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled. Detailed Description The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled. Recommended Response Action No response action required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR213 Message Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled. Detailed Description Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled.
Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR216 Message Unable to enable Extended Power Performance, because Redundancy Policy is set to Grid Redundancy or No Redundancy.
Recommended Response Action No response action is required. Category System Health (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR219 Message The Extended Power Performance (EPP) feature cannot be enabled because the PSU in slot arg1 is not a 3000 W PSU.
PWR220 Message The Extended Power Performance (EPP) feature cannot be enabled because slot arg1 is empty. Arguments arg1 = slot number Detailed Description The Extended Power Performance (EPP) feature cannot be enabled because the slot identified in the message is empty. Recommended Response Action Insert an appropriate PSU in the slot identified in the message and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2201 Message The system is sleeping with system hardware and processor context maintained. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2203 Message The system is sleeping with system hardware and processor context lost. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2205 Message The system is in a soft-off state. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2208 Message The system is in a sleep state. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR221 Message The Extended Power Performance (EPP) feature is already disabled. Detailed Description The Extended Power Performance (EPP) feature is already disabled. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2211 Message The system is in legacy ON state. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR222 Message The Extended Power Performance (EPP) feature is already enabled. Detailed Description The Extended Power Performance (EPP) feature is already enabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR2250 Message Unable to turn on the server because the chassis infrastructure not ready. Detailed Description The server did not turn on bacause the chassis infrastructure is not ready. The chassis infrstructure includes: PCIe subsystem, storage components, and the chassis management controller.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2252 Message Unable to turn on the server because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem. Detailed Description The server did not turn on because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem.
Recommended Response Action Install a PCI or Mezzanine card in the appropriate slot and retry the operation. Category Audit (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2254 Message The use of 110V is unacknowledged and the chassis cannot grant power on permission to the server.
Detailed Description The Chassis Managment Controller (CMC) is configured in Max Power Conservation Mode and is unable to grant power on permission to the server. Recommended Response Action Disable the Max Powe Conservation Mode on the chassis and retry the operation. Using the Chassis Management Controller (CMC) web interface, select Chassis Overview>Power>Configuration and then uncheck the Max Power Conservation Mode field.
PWR2257 Message The target power allocation override is arg1 . The target power allocation (AC) is arg2 Watts. Arguments arg1 = override state, arg2 = target power Detailed Description The target power allocation override has been enabled or disabled as identified in the message. Recommended Response Action No response action required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2260 Message The Intel Management Engine is unresponsive and the server thermal failsafe state is activated. Detailed Description The iDRAC experienced an IPMB communication issue with the Intel Management Engine and was not able to recover IPMB communications. The server thermal failsafe state is activiated. Recommended Response Action Disconnect power from the server and reconnect power. Turn on the server.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2262 Message The Intel Management Engine has reported an internal system error. Detailed Description The Intel Management Engine is unable to utilize the PECI over DMI facility. Recommended Response Action Look for the PWR2264 "normal system operation" message in the Lifecycle Log after the PWR2262 entry.
Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC PWR2264 Message The Intel Management Engine has reported normal system operation. Detailed Description The Intel Management Engine ihas recovered the ablility to utilize the PECI over DMI facility.
Recommended Response Action "1) Review system power policy. 2) Check system event logs for thermal or power related exceptions.
Detailed Description The iDRAC controller cannot communicate with the power management firmware due to an problem with the interface to the power management engine or with the power management engine itself. The system may operate in a performance degraded state. Recommended Response Action Check the Lifecycle Controller Log (LC Log) and make sure that there are no subsequent log entries indicating that Communication with power management firmware has been restored.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC PWR2404 Message Power supply capacity alert disabled. Detailed Description Power supply capacity alert disabled due to user configuration. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR3001 Message Detected new peak power value. Peak value (in Watts): arg1 . Arguments arg1 = peak value Detailed Description The system has detected a new peak power value. Recommended Response Action Make sure that the power usage corresponds to the the current hardware configuration and workload.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8501 Message Successfully set Virtual Infrastructure Device power to arg1 WDC Arguments arg1 = power reading Detailed Description Power allocation succeeded for Virtual infrastructure. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8504 Message Chassis power button is pressed, but the button is disabled. Detailed Description The chassis power button press is detected but the button has been disabled.
Detailed Description The Dynamic Power Supply Engagement feature was not successfully enabled. Recommended Response Action Restart the Chassis Management Controller and retry the operation. To restart the Chassis Management Controller, using the WEB UI, go to Chassis Overview > Power > Control, select the Reset CMC option, and then click Apply.
PWR8507 Message System Input Power Cap changed from arg1 W AC to arg2 W AC. Arguments arg1 = previous power value, arg2 = new power value Detailed Description The system Input Power Cap was changed from the value to the value indicated in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8509 Message Unable to change the server power priority because Server Based Power Management mode is enabled. Detailed Description Unable to change the server power priority because Server Based Power Management mode is enabled. Recommended Response Action The server power priority can be changed once Server Based Power Management mode is disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8511 Message Unable to set the CHASSIS_POWER_button_disable chassis power property. Detailed Description Unable to set the CHASSIS_POWER_button_disable chassis power property. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8514 Message Unable to perform chassis power action due to insufficient privileges. Detailed Description The user account credentials provided for this chassis power action do not have the correct privilege. Chassis control privilege is required to perform chassis power actions.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8516 Message Unable to perform the chassis power action requested.. Detailed Description Unable to perform the chassis power action requested. Recommended Response Action Check the tracelog for more information. If the issue persists, contact your service provider.
Category Audit (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8518 Message Unable to perform the chassis power action because the chassis is already turned on. Detailed Description Unable to perform the chassis power action because the chassis is already turned on.
Recommended Response Action No response action is required. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8520 Message Initiated the chassis reset operation. Detailed Description The chassis reset operation was initiated.
Detailed Description The chassis reset operation was completed. Recommended Response Action No response action is required. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8522 Message Initiated chassis power cycle operation.
PWR8523 Message Completed chassis power cycle operation. Detailed Description The chassis power cycle operation was completed. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8525 Message 110VAC Operation acknowledged. Detailed Description 110VAC operation of PSUs is acknowledged. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8527 Message Server slot power priorities changed - reallocating power. Detailed Description Server slot power priorities were changed. Power to servers is being reallocated. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8529 Message Max Power Conservation Mode is enabled. Detailed Description The Max Power Conservation Mode is enabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8531 Message Server Based Power Management Mode is enabled. Detailed Description Server Based Power Management Mode is enabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8533 Message Power cap changed from arg1 W AC to arg2 W AC. Arguments arg1 = power value, arg2 = power value Detailed Description Power cap setting was changed. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8535 Message Unable to set Server Based Power Management Mode to disable. Detailed Description Unable to set Server Based Power Management Mode to disable. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8537 Message Server Performance Over Power Redundancy is disabled. Detailed Description Server Performance Over Power Redundancy is disabled. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8539 Message Power Remote Logging is disabled. Detailed Description Power Remote Logging is disabled.
Detailed Description The interval for remote logging of power information is set to the value identified in the message Recommended Response Action No response action is required.
PWR8542 Message Chassis powerup operation completed. Detailed Description Chassis powerup operation completed. Recommended Response Action No response action is required. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8543 Message Server arg1 power inventory is not valid.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8544 Message Chassis Management Controller turned off the Server arg1 because of insufficient power at inventory. Arguments arg1 = slot number Detailed Description Insufficient power is available for the server identified in the message to function. The server will be turned off until there is sufficient power available.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8546 Message Chassis shutdown already in progress. Detailed Description A chassis shutdown was already in progress, when the additional shutdown request was received. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8548 Message Chassis shutdown operation initiated. Detailed Description Chassis shutdown operation initiated. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8550 Message Chassis shutdown completed. Detailed Description Chassis shutdown completed. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8552 Message Chassis Management Controller is unable to turn on arg1 - arg2 because of insufficient power. Arguments arg1 = component name, arg2 = component id Detailed Description There is insufficient power for the component identified in the message to turn on.
Arguments arg1 = component name, arg2 = component id, arg3 = priority number Detailed Description This situation occurs if the iDRAC is found to be turned off after power allocation information is sent by the CMC or if the communications between the CMC and iDRAC is non functional. Recommended Response Action Perform a Virtual Reseat of the component identified in the message.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* PWR8556 Message Server arg1 was shutdown due to insufficient power. Arguments arg1 = slot number Detailed Description The Server identified in the message was shutdown due to insufficient power. Recommended Response Action No response action is required.
Recommended Response Action Increase the Power Cap value. To increase the Power Cap do one of the following: 1) Using CMC Web interface: Select "Chassis Overview" -> Power -> Configuration and then adjust System Input Power Cap values. 2) Run the following RACADM command at the command line interface: "config -g cfgChassisPower -o cfgChassisPowerCap ". Try setting the power cap above the lower bound displayed on the power configuration page.
PWR8559 Message Power cycle initiated for I/O Module arg1 . Arguments arg1 = iIOM slot name Detailed Description Power cycle initiated for the I/O module in the slot identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* PWR8561 Message Unable to power on server arg1 because of iDRAC communication issue. Arguments arg1 = server number Detailed Description The Chassis Management Controller is unable to communicate with the Server iDRAC service processor and the server could not be powered on. This situation may occur when iDRAC is rebooting. Recommended Response Action Wait for three minutes and then retry the operation.
Category Audit (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8563 Message Unable to turn on Server arg1 due to I/O fabric inconsistency.
Detailed Description The server identified in the message was not turned on because the available power is less than the requested power. Recommended Response Action Utilize the Chassis Management Controller web interface to check the System Input Max Power Capacity Power and server power requirements. If sufficient power is available, retry the operation. Otherwise, increase the System Input Power Cap value.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* PWR8566 Message Unable to turn off the Server arg1 before the Power Off timer expired. Arguments arg1 = server number Detailed Description Unable to turn off the Server before the Power Off timer has expired. This happens if the Server did not show "power off" status change within 30 seconds after the operation was initiated. This situation may also occur when iDRAC is rebooting.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8568 Message Server arg1 did not gracefully shutdown before the timer expired. Arguments arg1 = slot number Detailed Description The server identified in the message did not gracefully shutdown before the CMC shutdown timer expired.
Recommended Response Action Turn on the server, if necessary, before requesting a power cycle operation. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8570 Message Unable to communicate to the iDRAC, when trying to power cycle the server arg1 .
PWR8571 Message Unable to perform the power action requested for the server arg1 because another power action is in progress. Arguments arg1 = server idr Detailed Description Another power action is in progress. The requested power action cannot be carried out until the power action in progress completes Recommended Response Action Wait for the power action in progress to complete and retry the operation. It may take a few minutes for the current power action to complete.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8573 Message The Chassis Management Controller is unable to communicate to the iDRAC, when trying to turn off the server arg1 . Arguments arg1 = server id Detailed Description The Chassis Management Controller is not able to communicate with the iDRAC on the server identified in the message. Therefore the server could not be turned off. This situation may occur when iDRAC is restarting.
Category Audit (PWR = Power Usage) Severity Severity 1 (Critical) Trap/EventID 8417 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* PWR8575 Message Initiated the Virtual Reseat of server arg1 . Arguments arg1 = server id Detailed Description A Virtual Reseat for the server identified in the message is initiated.
Detailed Description The virtual reseat initiated on the Sleeve or Sled identified in the message successfully turned off the component. However, the Sleeve or Sled did not turn on successfully. A virtual reseat is the same as removing and inserting a Sleeve or Sled. Recommended Response Action Retry the virtual reseat operation on the Sleeve or Sled identified in the message. If the issue persists, manually remove and reinsert the Sleeve or Sled in the chassis.
PWR8578 Message Chassis Management Controller is unable to turn on the iDRAC on server- arg1 because power required is less than available power. Arguments arg1 = slot number Detailed Description The Chassis Management Controller is unable to turn on the iDRAC because power required is less than available power. Recommended Response Action Make sure there is enough power supply to distribute power. Go to, the Chassis Overview > Power > Power Budget Status.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8580 Message Chassis Management Controller is unable to turn on server- arg1 because the Chassis is not turned on. Arguments arg1 = slot number Detailed Description The power on request for the server identified in the message was not successful because the Chassis is turned off.
Recommended Response Action Wait until the current chassis power operation is complete and the chassis is On and then retry the operation.
PWR8583 Message Chassis Management Controller is unable to turn on server- arg1 because unacknowledged 110V PSUs are present. Arguments arg1 = slot number Detailed Description To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If the feature is not enabled, the server turn-on operation will not be processed. Recommended Response Action On the Power Configuration page, in the Web UI, select the Allow 110VAC Operation for power supplies and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR8585 Message Chassis Management Controller granted the power required to turn on serverarg1 . Arguments arg1 = slot number Detailed Description Chassis Management Controller granted the power required to turn on the server identified in the message. Recommended Response Action No response action is required.
Recommended Response Action The server inserted is not supported in the Chassis. Remove the server from the Chassis. Category Audit (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC PWR8587 Message Chassis Management Controller is unable to turn on server- arg1 because the chassis enclosure is open.
PWR8588 Message Chassis Management Controller is unable to turn on server- arg1 because a chassis infrastructure firmware update is in progress. Arguments arg1 = slot number Detailed Description The server identified in the message cannot be turned on while a chassis infrastructure firmware update operation is in progress. Recommended Response Action The chassis infrastructure firmware update is in progress. Retry the operation after the firmware update is complete.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* PWR8590 Message The server- arg1 does not have PCIe Mezzanine card in slot C1. Arguments arg1 = slot number Detailed Description The PCIe Mezzanine card in the slot C1 is absent. Without PCIe Mezzannine cards, the chassis PCIe cards will not be available for servers. Recommended Response Action Insert a PCIe Mezzanine card in slot C1.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* PWR8592 Message Chassis Management Controller is unable to turn on or turn off the chassis because another chassis power operation is in progress. Detailed Description The request to turn on or turn off the chassis was issued before the previous power operation was completed.
Arguments arg1 = requested watts, arg2 = available watts Detailed Description The available power is not sufficient to enable the Enhanced Cooling Mode feature. Recommended Response Action Make sure there is enough power supply to enable the Enhanced Cooling Mode feature. Go to, the Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field view the available power. To add more power, insert more PSUs or remove unused components from the chassis.
Detailed Description The Chassis Management Controller cannot turn on the server identified in the message, because PSU redundancy is lost or PSUs are removed. Sufficient power is not available for the operation. Recommended Response Action Make sure there is enough power supply to distribute power. Go to, the Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field, view the available power.
Detailed Description The Power Supply Unit (PSU) identified in the message is turned off because it is not compatible with the other PSUs in the Chassis. Recommended Response Action Replace the PSU with an appropriate unit, and then retry the operation. For a list of PSUs that are compatible, consult the system Owners Manual or contact your service provider.
PWR8602 Message The multinode sled power button is enabled. Detailed Description The power buttons for all multinode sleds in the chassis are enabled. The operation to enable the power button is only applicable to the multinode sleds available, and does not affect other servers in the chassis. Recommended Response Action To disable the chassis power button use the CMC RACADM command line interface (CLI) or CMC Web interface.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8655 Message Chassis Management Controller (CMC) is unable to turn on the component arg1 arg2 because of insufficient power. The minimum required power is arg3 AC Watts, but only arg4 AC Watts is available.
Arguments arg1 = component name, arg2 = slot number Detailed Description CMC could not successfully turn on the component identified in the message, because of insufficient power available. Recommended Response Action Make sure there is sufficient power available, and then retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* PWR8664 Message The Dynamic Power Supply Engagement feature is arg1 . Arguments arg1 = enabled or disabled Detailed Description The power configuration property dynamic power supply engagement feature is disabled or enabled as identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8666 Message The iKVM power cycle operation is initiated. Detailed Description The iKVM power cycle operation is initiated. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8668 Message Chassis Management Controller (CMC) has initiated the process of resetting iKVM. Detailed Description Chassis Management Controller (CMC) has initiated the process of resetting iKVM. Recommended Response Action No response action is required.
Category Audit (PWR = Power Usage) Severity Severity 1 (Critical) Trap/EventID 8417 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* PWR8670 Message Unable to turn on server arg1 because the required power arg2 AC Watts exceeds the subsystem Connector Limit arg3 AC Watts for IO modules, Blowers and Servers.
PWR8671 Message The Chassis Management Controller is unable to set the Enhanced Cooling Mode because the requested power arg1 AC Watts exceeds the subsystem power limit arg2 AC Watts for IO Modules, Blowers and Servers. Arguments arg1 = requested power level, arg2 = power limit Detailed Description The Enhanced Cooling Mode feature cannot be enabled because the requested power exceeds the Chassis subsystem power limit for IO Modules, Blowers and Servers.
Category Configuration (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* PWR8673 Message arg1 hassis configuration detected at arg2 arg3 . Arguments arg1 = Carrier grade, arg2 = voltage, arg3 = power state Detailed Description Displays voltage change with power configuration change.
Recommended Response Action No response action is required. Category System Health (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔* IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy ✔* PWR8675 Message AC power supply is detected in the NEBS configuration. Detailed Description AC power supply is detected in the NEBS configuration.
Detailed Description The chassis power property identified in the message cannot be set. Recommended Response Action Contact your service provider. Category Configuration (PWR = Power Usage) Severity Severity 2 (Warning) Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔* IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* PWR8677 Message Dynamic Power Supply Engagement configuration is changed.
PWR8678 Message The value of the property arg1 is arg2 . Arguments arg1 = power property name, arg2 = enable or disable Detailed Description The power property identified in the mesage is changed as identified in the message.. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* ✔* ✔* PWR8681 Message The arg1 firmware in the server slot arg2 does not support additional PCIe slots. Arguments arg1 = iDRAC/BIOS, arg2 = slot number Detailed Description The firmware identified in the message does not support the PCIe reassignment operation. Recommended Response Action Update the firmware identified in the message to the supported latest available version.
Severity Severity 2 (Warning) Trap/EventID 2274 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* ✔* PWR8683 Message Initiated the Virtual Reseat of peripheral arg1 . Arguments arg1 = slot number Detailed Description A Virtual Reseat for the peripheral sled identified in the message is initiated.
Recommended Response Action No response action is required. Category System Health (PWR = Power Usage) Severity Severity 3 (Informational) Filter Visibility iDRAC ✔ CMC ✔ LC Log iDRAC ✔* CMC ✔* IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing Reset Chassis Event Proxy ✔* ✔* PWR8685 Message The arg1 firmware in the server slot arg2 supports the storage sled.
PWR8686 Message The Chassis Management Controller (CMC) is unable to turn on the storage sleds associated with server in slot arg1 because the iDRAC firmware version in the server does not support the chassis storage module. Arguments arg1 = slot number Detailed Description The Chassis Management Controller (CMC) is unable to turn on the storage sled controller identified in the message because iDRAC version installed on the server is not compatible.
Recommended Response Action Install a Mezzanine card in the Mezzanine card slot of the server identified in the message, and then retry the operation.
RAC Event Messages RAC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC002 Message General failure. Detailed Description An unknown error occurred. Recommended Response Action Do one of the following: 1) Rerun the command. 2) Reset iDRAC and retry the operation.
RAC004 Message Invalid parameter value for arg1 . Arguments arg1 = parameter Detailed Description The parameter value for the given parameter is invalid. Recommended Response Action Provide a valid parameter value for specified parameter. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC005 Message Mismatch in AttributeName and AttributeValue count.
RAC007 Message The attribute value is outside the acceptable range. Detailed Description The attribute value is outside the acceptable range. Recommended Response Action Enter a value within the range and retry the operation. For more information about the acceptable range, refer to the Dell Lifecycle Controller Remote Services Quick Start Guide and DCIM Profile Documents available at the support site.
RAC010 Message Input contains invalid character. Detailed Description The input value for the attribute being set contains characters that are not allowed. Recommended Response Action Retry the operation using valid input characters. Refer to the Lifecycle ControllerRemote Services documentation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0100 Message The Smart Card is removed. Further communication is not possible.
RAC0102 Message The Smart Card Logon plug-in is not installed. Install the plug-in from the iDRAC Web GUI to log in using Smart Card. Detailed Description The software to communicate with the Smart Card is not loaded in this browser. Smart Card can be used for log in only if the appropriate Smart Card software is installed in the browser. Recommended Response Action Install the plug-in prompted by the iDRAC Web GUI to log in using Smart Card.
RAC0105 Message The Smart Card reader cannot be detected. Check whether the reader is installed correctly. Detailed Description Communication with the Smart Card reader cannot be established, or is lost. Recommended Response Action This error may occur because: 1. Check connection between reader and system. 2. There may be an issue with the Smart Card reader. Try reinstalling the reader driver or use a different reader.
No alerts are applicable for this message RAC0108 Message An internal error is encountered. Insert a valid Smart Card and try again. (Does this and preceeding messages show up in the SEL?) Detailed Description A non-specific error is detected when accessing the Smart Card. Recommended Response Action Review the error message preceeding or following this message.
RAC0115 Message The Destination IP Address value is invalid. Detailed Description The IPv4 address does not conform to the addressing standard or the supported IPv4 address range. Recommended Response Action Enter the Destination IP Address value between [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0116 Message Invalid Destination IPv6 Address.
RAC0118 Message Unsupported vFlash SD card detected. Detailed Description The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions. Recommended Response Action Insert a supported vFlash SD card. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC012 Message Unable to perform the operation because of insufficient user privileges.
RAC0121 Message SD card is not initialized. Detailed Description SD card not readable. The card must be initialized. Recommended Response Action Initialize the SD card before it can be used. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0124 Message Invalid label: Label must be exclusively alphanumeric characters. Detailed Description All characters in the label must be alphanumeric.
RAC0127 Message The specified size must be a non-fractional numeric value. Detailed Description Size must be a whole number. Recommended Response Action Enter a whole number for the size field. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0128 Message An error has occurred in vFlash. Detailed Description A non-specific error has been detected while accessing the vFlash.
RAC013 Message Unable to run the method becuase an invalid FQDD is entered. Detailed Description The method cannot be run because an invalid FQDD is entered. Recommended Response Action Enter a valid FQDD and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0130 Message An error has occurred while creating a partition.
RAC0132 Message An error has occurred while formatting a partition. Detailed Description A seperate message will provide more detail about this error which was detected while formatting the vFlash partition. Recommended Response Action No response action is required. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0133 Message An error has occurred while downloading a partition.
RAC0135 Message An error has occurred while detaching a partition. Detailed Description A seperate message will provide more detail about this error which was detected while detaching the vFlash partition. Recommended Response Action No response action is required. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0136 Message An error has occurred while attaching a partition.
RAC0138 Message A valid certificate is not loaded. Detailed Description The retrieved certificate came back as a null or empty document. Recommended Response Action Upload a valid certificate. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC014 Message Unable to run the method becuase an invalid attribute name is entered. Detailed Description The method cannot be run because an invalid attribute name is entered.
RAC0141 Message Firmware update verification failed: The update status is unknown. Detailed Description Firmware update verification process failed; the firmware update status is unknown. Recommended Response Action Verify if the firmware has been updated by checking the new firmware version number. If it has not been updated try the firmware update again in a few minutes. If the problem persists, try uploading the firmware through another interface such as Web GUI, RACADM, or DUPs.
RAC0147 Message Rollback firmware is not available. Detailed Description Firmware rollback image is missing or is corrupt. Recommended Response Action Upload a new firmware image. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0148 Message Unable to retrieve the batteries information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about the batteries.
RAC015 Message Unable to run the method becuase the input value is not one of the possible values for AttributeName arg1 . Arguments arg1 = attribute name Detailed Description The input attribute value is not valid for the attribute identified in the message. Recommended Response Action Provide valid attribute value for the attribute identified in the message and retry the operation.
RAC0152 Message Unable to retrieve the power supply information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about power supplies. Recommended Response Action Turn the system on to view this information. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0153 Message Non-redundant power mode: Check the system hardware manual for implications.
RAC0155 Message Unable to retrieve the temperature information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about system temperature. Recommended Response Action Turn the system on to view this information. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0156 Message Unable to retrieve the voltage information. The system is powered off.
RAC0159 Message Certificate upload failed: No pending CSR or private key. Detailed Description Certificate upload failed because there is no pending Certificate Signing Request (CSR) or private key. Recommended Response Action Upload failed due to no pending Certificate Signing Request (CSR). Try creating a new CSR and then upload the certificate.
RAC0169 Message Certificate upload failed: Certificate is not valid. Detailed Description Certificate upload failed because the certificate is not valid. Recommended Response Action Certificate may be corrupt. Try creating a new Certificate Signing Request (CSR) and then upload the certificate. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC017 Message Job created to apply the attribute value.
RAC018 Message The Job is completed but with errors.. Detailed Description All the tasks in the Job were attempted, but some did not complete successfully. Recommended Response Action Examine source of the errors by inspecting the results from the Job execution, and after resolving the issues, retry the operation. Job results can be retrieved from the Lifecycle Log or the WSMan API.
RAC020 Message Completed Detailed Description The submitted job completed successfully. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0206 Message Certificate upload failed: Not a certificate file. Detailed Description Certificate upload failed because this is not a certificate file. Recommended Response Action Upload a valid certificate.
RAC0208 Message Upload failed: May be due to invalid key data. Detailed Description Upload failed possibly due to invalid key data. Recommended Response Action Upload a certificate with a valid key. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0209 Message Certificate upload failed: iDRAC unable to upload at this time. Detailed Description Certificate upload failed because iDRAC unable to upload at this time.
RAC0211 Message Firmware update has failed. Detailed Description Firmware update has failed. This may be due to a corrupt firmware image, poor network connection, or another issue. Recommended Response Action Download a new firmware image and try loading the firmware again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0212 Message Login failed. Verify that username and password is correct.
RAC0214 Message Missing Password. Detailed Description Login page is missing a password. Recommended Response Action Enter a valid password. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0215 Message Login failed: User does not have Login to iDRAC privilege. Detailed Description Login failed because the user does not have Login to iDRAC privilege. Recommended Response Action Login to iDRAC privilege is needed.
RAC0217 Message iDRAC is not responding. Detailed Description Client did not receive a response for the login request. Recommended Response Action Try pinging the iDRAC and then try again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0218 Message The maximum number of user sessions is reached. Detailed Description A maximum of 4 iDRAC Web GUI sessions can be open at any time.
RAC022 Message Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the User Name is not configured. Detailed Description Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the User Name is not configured. Recommended Response Action Set User Name before attempting to set values of other identified attributes.
RAC0223 Message Enter an alphanumeric value or a valid symbol for the following (see the online help for more information): Detailed Description The Subject line in the email contains invalid characters. Recommended Response Action Invalid character. Enter a valid value as mentioned in the online help. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0224 Message Invalid e-mail description.
RAC0226 Message Send Failed: Request processing failed. Detailed Description Sending the test mail failed. This will prevent alert messages from being sent to this email address. Recommended Response Action Confirm that: 1. A valid SMTP server address is configred in the iDRAC. 2. The remote email server is configured properly to send and receive emails.
RAC023 Message Unable to enable the User or set values for IPMILan, IPMISerial, or User Admin Privilege because the User Password is not configured. Detailed Description Unable to enable the User or set values for IPMILan, IPMISerial, or User Admin Privilege because the User Password is not configured. Recommended Response Action Set User Password before attempting to enable the other identified attributes.
RAC0235 Message vFlash image upload timed out. Detailed Description When uploading an image to the vFlash partition, the operation is unresponsive, and has timed out. Recommended Response Action Try uploading the vFlash image again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0236 Message Invalid image: Upload failed Detailed Description vFlash image upload failed because the image is not valid.
RAC0238 Message vFlash is currently in-use by another process. Try again later. Detailed Description vFlash is unable to service the request at this time. Try again later. Recommended Response Action Try the operation after a few minutes. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0239 Message SD Card is write-protected. Detailed Description The contents of a write protected SD Card cannot be modified.
RAC0240 Message vFlash is disabled. Detailed Description vFlash needs to be enabled before attempting this operation. Recommended Response Action Enable vFlash before trying the operation. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0241 Message The specified size exceeds the maximum size of arg1 MB. Arguments arg1 = size Detailed Description SD Card does not have enough free space available.
RAC0243 Message Partition failed: A partitioning conflict has occurred with another session. Detailed Description There was a conflict with a concurrent session. Another user may have logged inusing a separate browser or RACADM. Recommended Response Action There was a conflict with a concurrent session. Refresh the page to see the currently available options.
RAC0246 Message Partition is read-only. Detailed Description The contents of a read-only partition cannot be modified. Recommended Response Action Make sure the partition is writable before attempting to change its contents. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0247 Message The partition is currently attached.
RAC0249 Message One or more partitions are in-use by another process. Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
RAC0251 Message One or more partitions are currently attached. Detailed Description The vFlash partitions are attached. Therefore, the current operation cannot proceed. Recommended Response Action Detach the partitions and try again. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0252 Message One or more partitions are currently detached.
RAC0254 Message The Gateway Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Detailed Description This error message is displayed to indicate that the IPv4 Gateway Address does not conform to the required format Recommended Response Action Enter a valid Gateway Address. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
RAC0257 Message The Alternate DNS Server Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Detailed Description This error message is displayed to indicate that the Alternate DNS IPv4 address does not conform to the required format. Recommended Response Action Enter a valid Alternate DNS Server Address. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
RAC0260 Message Invalid IPv6 prefix length. Expected range: 0-128. Detailed Description The specified IPv6 address prefix length is invalid. Recommended Response Action Enter a valid IPv6 prefix length. Expected range: 0-128. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0261 Message Invalid IPv6 gateway address.
RAC0263 Message The Alternate IPv6 DNS Server Address is invalid. Detailed Description This error message is displayed to indicate that the Alternate IPv6 DNS Server address does not conform to the required format. Recommended Response Action Enter a valid Alternate IPv6 DNS server address. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0265 Message Specify the VLAN ID and VLAN Priority.
RAC0267 Message Invalid VLAN Priority. Expected range: 0-7. Detailed Description Specify a valid VLAN Priority. Recommended Response Action Enter a valid VLAN Priority. Expected range: 0-7. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0268 Message NIC is disabled. Detailed Description The NIC is disabled. This may adversely affect the current operation, and might not allow subsequent GUI interactions to this NIC.
RAC027 Message Unable to set values for Speed or Duplex because Auto Negotiation is Enabled. Detailed Description Unable to set static values for Speed or Duplex when the Auto Negotiation attribute is enabled. Recommended Response Action Disable Auto Negotiation in order to set values for Speed or Duplex. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0270 Message IPv4 and IPv6 are disabled.
RAC0272 Message Disabling NIC will prevent the user from accessing the iDRAC remotely through Web GUI, Remote Racadm, Ssh, and Telnet. Local Racadm and serial interface will continue to work. Detailed Description If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled. Recommended Response Action Disable NIC only if remote access is undesired.
RAC0275 Message Click OK to disable the NIC. Click Cancel to keep the setting unchanged. Detailed Description If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled. Recommended Response Action Disable NIC only if remote access is undesired. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0276 Message To save the changes and update this page, click Apply.
RAC0278 Message Disabling IPv6 prevents access to iDRAC using an IPv6 address. Detailed Description This warning message appears when IPv6 is disabled. Recommended Response Action Use IPv4 network to access iDRAC remotely. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0279 Message Invalid Encryption Key. Expected format: 0 to 40 characters, even number of characters and no blank spaces are allowed.
RAC0280 Message The IP Range Address is invalid. Expected range: 0.0.0.0 - 255.255.255.255. Detailed Description This error message is displayed to indicate that the IPv4 address does not conform to the required format. Recommended Response Action Enter a valid IP Range Address. Expected range: 0.0.0.0 - 255.255.255.255. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0281 Message The IP Subnet Mask is invalid. Expected range: 0.0.
RAC0283 Message IP Blocking Fail Window is invalid. Expected range: 10-65535. Detailed Description This is the time span (in seconds) within which IP Blocking Fail Count failures must occur to trigger the IP Blocking Penalty Time. The default value is 3600 seconds (1 hour). Recommended Response Action Enter a valid IP Blocking Fail Window. Expected range: 10-65535.
RAC0286 Message New Password and Confirm New Password fields cannot be empty. Detailed Description When creating a user account, the New Password and Confirm New Password fields cannot be empty. Recommended Response Action Enter valid passwords for New Password and Confirm New Password. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0288 Message Invalid entry: Entry must be exclusively alphanumeric characters and valid symbols.
RAC029 Message Unable to complete the operation because necessary dependency values are not found in the input. Detailed Description The operation cannot be completed because necessary dependencay values are not found in the input. Recommended Response Action Refer to the Dell Lifecycle Controller Remote Services Quick Start Guide and Profile Documents available at the support site, and then retry the operation.
RAC0292 Message A valid certificate is not loaded. Detailed Description This error is displayed when LDAP or Active Directory cannot find its certificate. Recommended Response Action Load a valid certificate. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0293 Message When certificate validation is enabled, a valid root Certificate Authority (CA) certificate must be uploaded.
RAC0295 Message The Character Send Threshold value is invalid. Expected range: 1-255. Detailed Description This is the number of characters per Serial Over LAN (SOL) data packet. When the number of characters accepted by iDRAC is equal to or greater than the Character Send Threshold value, iDRAC starts transmitting SOL data packets that contain the numbers of characters equal to or less than the Character Send Threshold value.
RAC030 Message This attribute is dependent on a related attribute that has an incorrect value. Detailed Description This attribute is dependent on a related attribute that has an incorrect value. The related attribute is the parent in a parent-child value dependency relationship and has an affect on what values the child attribute can have.
RAC0303 Message Virtual Console is disabled or you do not have the Access Virtual Console privilege. Detailed Description This error message is displayed when Virtual Console feature is unavailable. Recommended Response Action Enable Virtual Console and ask the administrator to grant Access Virtual Console privilege. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0304 Message Firmware update is terminated.
RAC032 Message Invalid value specified for DNS RAC name. Detailed Description The DNS RAC name specified is not valid. Recommended Response Action Retry operation with valid DNS RAC name. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC033 Message Unable to enable attribute because IPv4 is Disabled. Detailed Description The specified attribute cannot be enabled since it depends on IPv4 to be enabled.
RAC035 Message No pending configurations. Detailed Description There are no pending values for the any of the iDRAC attributes. Recommended Response Action Make sure there are pending values for the attributes that are targeted for configuration. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC036 Message Attribute dependency failed.
RAC038 Message Unable to perform the operation due to an unknown error in iDRAC. Detailed Description The operation did not complete successfully because of an unknown error in the iDRAC. Recommended Response Action Retry the action. If the issue persists, reset the iDRAC. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC039 Message Invalid parameter value for arg1 .
RAC0400 Message iDRAC memory low. Detailed Description iDRAC is running low on memory. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC041 Message The set operation on the event filters failed. Detailed Description The event filters set operation did not complete successfully due to invalid input parameters. Recommended Response Action Verify the specified input parameters and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
No alerts are applicable for this message RAC044 Message Unable to update some event filter settings. Detailed Description Some event filter settings were not updated due to problems encountered processing the input parameters. Recommended Response Action Verify the input parameters provided and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
RAC047 Message Unsupported event action for the specified event filter. Detailed Description The event action selected is not supported for the event filter specified. Recommended Response Action Refer to the iDRAC User Guide and Lifecycle Controller documentation and retry the operation with a valid event action selection on the specified filter.
RAC050 Message Invalid country code. Detailed Description The country code is not entered in the correct format or does not exist. Refer to ISO 3166 for the correct country code format. Recommended Response Action Enter country code in the correct format as defined in ISO 3166. For example, United States = US. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0500 Message There are no batteries to be displayed.
RAC0502 Message There are no virtual disks to be displayed. Detailed Description Virtual disks cannot be displayed. This error may occur if the host system is powered off or there are no virtual disks created. Recommended Response Action 1. Check if the host system is powered off or shutdown. 2. Check if virtual disks are created.
RAC0505 Message There are no devices to be displayed. Detailed Description Devices are not displayed. This error may occur because these components are removed or disconnected. Recommended Response Action 1. Check if the host system is ON. 2. Check if the Storage Enclosure is ON. 3. Verify that the adapter cables are properly connected and there are no bent pins.
RAC0508 Message An unexpected error occurred. Detailed Description The server encountered an unexpected condition. This may be due to invalid JavaScript Object Notation. Recommended Response Action Wait for few minutes and refresh the page. If the problem persists, contact service provider. Category Storage (RAC = RAC Event) Severity Severity 1 (Critical) No alerts are applicable for this message RAC0509 Message The server is temporarily unavailable.
RAC0510 Message There are no events to be displayed. Detailed Description This error occurs if Lifecycle log events have not occurred recently. Recommended Response Action No response action is required. Category Storage (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0511 Message There are no physical disks to be displayed. Detailed Description Physical disks cannot be displayed.
RAC0513 Message There are no virtual disks to be displayed. Detailed Description There are no virtual disks to be displayed. There may be no virtual disks created, the controller(s) may not be in RAID mode, or there may be pending creation or deletion jobs that have not completed. Recommended Response Action Check the following: 1) Check if the server is turned off. If the server is turned off, turn it on and wait until POST completes.
No alerts are applicable for this message RAC0516 Message Converting physical disk drives to RAID-compatible will overwrite any OS-created RAID arrays. Detailed Description Converting physical disk drives to RAID-compatible will overwrite any OS-created RAID arrays. Recommended Response Action Make sure that there are no OS-configured RAID arrays, and then click OK.
Detailed Description One or more attributes being set are dependent on OS to iDRAC pass-through being enabled. Recommended Response Action Enable OS to iDRAC pass-through and retry the previous command. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC054 Message User account attributes cannot be reset to default values due to an internal error.
Detailed Description The Authentication Protocol attribute for the user account identified in the message cannot be disabled because the Privacy Protocol attribute is enabled. The Privacy Protocol for the user account is not set to None. Recommended Response Action Disable the Privacy Protocol attribute for the identified user ID account by setting the value to None, and retry the operation to set Authentication Protocol attribute to None.
Recommended Response Action Do the following: 1) Check the Lifecycle Log for the subsequent RAC0562 communications restored message that will indicate the link was re-established automatically. 2) If there is no subsequent RAC0562 message in the Lifecycle Log, restart the iDRAC. The iDRAC can be restarted by using the RACADM command line utility and entering "racadm racreset".
LC Log iDRAC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RAC057 Message Unable to set Privacy Protocol to an enabled state because the Authentication Protocol attribute is set to None for the user ID: arg1 Arguments arg1 = user ID Detailed Description The Privacy Protocol for the user cannot be enabled because the Authentication protocol is disabled.
Recommended Response Action Disable Network Time Protocol (NTP) and retry the operation.
Recommended Response Action Wait for few minutes and refresh the page. If the problem persists, contact service provider. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0602 Message Invalid value for alert recurrence. Detailed Description The value for alert recurrence must be within the range 0-365. Recommended Response Action Enter a value between 0-365.
Recommended Response Action Enable CSIOR, restart the system and retry the operation. To enable CSIOR, press F2 (System Setup) during system startup, navigate to iDRAC Settings >Lifecycle Controller, and select the Enabled option for Collect System Inventory on Restart. Category Configuration (RAC = RAC Event) Severity Severity 1 (Critical) No alerts are applicable for this message RAC0605 Message There are no jobs to be displayed. Detailed Description There are no jobs to be displayed.
Recommended Response Action Make sure the integrated NICs are enabled from BIOS setup and support OS to iDRAC Pass-Through, then retry the operation. To access BIOS setup, press F2 during system startup. For more information about OS to iDRAC Pass-Through, see iDRAC7 Users Guide. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0608 Message The iDRAC will restart when the iDRAC firmware update is complete.
Detailed Description The IPMI Watchdog can not be enabled at the same time as the OS Watchdog. Recommended Response Action Disable the OS Watchdog before enabling IPMI Watchdog. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0610 Message The passphrase and confirm passphrase values entered do not match. Detailed Description Different values were entered for passpharse and confirm passpharse field.
Recommended Response Action Select Yes to cancel the firmware update operation and delete all uploaded firmware files. Select No to dismiss the message and continue the firmware update operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0613 Message The uploaded file is invalid. Detailed Description An internal error occurred because of an invalid file.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0616 Message Error while extracting custom signing certificate and private key from the PKCS#12 file. Detailed Description iDRAC was unable to continue with the operation after the PKCS#12 file was uploaded, because it is not able to extract the custom signing certificate and private key.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0619 Message The iDRAC firmware rollback will cause an iDRAC restart and all current user sessions will be closed. Detailed Description The message appears in Firmware Rollback page when the iDRAC firmware rollback action completed successfully. Recommended Response Action Reconnect iDRAC communications sessions after iDRAC is restarted. The iDRAC will be ready for login once the restart is complete.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0621 Message Successfully completed the iDRAC firmware update. All current user sessions will be closed. Detailed Description The message appears in Job Queue page when the iDRAC firmware update job status is completed. Communication to the iDRAC will be lost . Recommended Response Action The iDRAC will be ready for login once the restart is complete.
No alerts are applicable for this message RAC0624 Message Unable to find the requested job type or ID. Detailed Description The requested operation could not be completed, because an incorrect job type or job ID is entered. Recommended Response Action Enter the correct job type or ID, and then retry the operation.
RAC0627 Message Unable to schedule, because the requested recurrent Automatic Backup job is already scheduled. Detailed Description The job cannot be scheduled, because the requested recurrent Automatic Backup job is already scheduled. Recommended Response Action Delete the current scheduled job, and then retry to create a new Automatic Backup job with a new schedule.
RAC063 Message The string length of the provided value for arg1 is inappropriate. Arguments arg1 = attribute name Detailed Description The string length of the entered value for the attribute identified in the message may be less than the minimum length or greater than the maximum length allowed. Recommended Response Action Make sure that the string length is correct and retry the operation.
RAC0632 Message Unable to access the network file share, because an invalid network file share hostname or IP address is entered. Detailed Description The requested network file share cannot be accessed, because an invalid hostname or IP address is entered. Recommended Response Action Enter a valid network file share hostname or IP address, and then retry the operation.
RAC0635 Message Unable to access the network file share, because an invalid domain name is entered. Detailed Description The requested network file share cannot be accessed, because an invalid domain name is entered. Recommended Response Action Enter a valid domain name, and then retry the operation.
RAC0638 Message Unable to access the network file share, because an invalid proxy host name or IP address is entered. Detailed Description The requested network file share cannot be accessed, because an invalid proxy host name or IP address is entered. Recommended Response Action Enter a valid proxy host name or IP address, and then retry the operation.
RAC0640 Message Unable to schedcule, because an invalid hour value is entered. Detailed Description The job could not be successfully scheduled, because an invalid value is entered for hour while scheduling a job. Recommended Response Action Enter a correct value from 0 to 23, and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0641 Message Unable to schedcule, because an invalid timevalue is entered.
RAC0643 Message Unable to schedule, because an invalid monthvalue is entered. Detailed Description The job could not be successfully scheduled, because an invalid value is entered for month while scheduling a job. Recommended Response Action Enter a correct numerical value in the following format: Day [1 to 31] of every [1 to 12] month(s). For example, Day 4 of every 11 months. Retry the operation.
RAC0646 Message Unable to schedule, because an invalid value is entered for the day of the week. Detailed Description The job could not be successfully scheduled, because an invalid value is entered for day of the week while scheduling a job. Recommended Response Action Enter a correct value, and then retry the operation.
RAC0649 Message Unable to process the request. Detailed Description Unable to process the request, because data is not entered or not selected in one or more mandatory fields. Recommended Response Action Make sure to enter or select data in all the mandatory fields, and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC065 Message iDRAC reset operation was not successful.
RAC0655 Message The Replicate Lifecycle Controller Log in OS Log and Auto System Recovery Action features are disabled in the iDRAC Service Module because the OpenManage Server Administrator is installed on the server operating system. Detailed Description The Replicate Lifecycle Controller Log in OS Log and Auto System Recovery Action features are disabled in the iDRAC Service Module because the OpenManage Server Administrator is installed on the server operating system.
No alerts are applicable for this message RAC0658 Message The iDRAC Service Module service can now be manually started on the server operating system. Detailed Description The iDRAC Service Module service can now be started on the server operating system. This service needs to be started manually on the server operating system.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0660 Message Unable to access the specified file server location. Detailed Description The file server cannot be accessed because of incorrect credentials. Recommended Response Action Check the file server credentials and retry the operation.
Recommended Response Action Press OK to continue. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0663 Message Resetting the selected PERC controllers configuration will delete all the virtual disks (VDs) and unassign hot-spares from the associated controller. Detailed Description Resetting the selected PERC controllers configuration will delete all the virtual disks (VDs) and unassign hot-spares from the associated controller.
Arguments arg1 = number of minutes Detailed Description RAID Controller Log data is being collected. This operation will take less than the number of minutes identified in the message. Recommended Response Action Do not log off from the application until the log data collection process is completed. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0666 Message A RAID Controller Log is created.
RAC0668 Message This setting will be applied during the next server restart. If the setting is not compatible with the RAID Controller, then LED status indicators on all the associated hard disk drives (HDDs) stop functioning. Detailed Description This setting will be applied during the next server restart. If the setting is not compatible with the RAID Controller, then LED status indicators on all the associated hard disk drives (HDDs) stop functioning.
RAC0670 Message Deleting the virtual disk will remove the virtual disk from the controllers configuration. Detailed Description Deleting the virtual disk will remove the virtual disk from the controllers configuration. If the specified virtual disk is a boot device, the server will not boot unless another boot device is selected in BIOS. Recommended Response Action If the specified virtual disk is a boot device, the server will not boot. Press OK to continue.
Recommended Response Action Invoke the OS Collector utility in the OS and wait for execution completion. Then return to this page to complete exporting the Technical Support Report (TSR). Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0674 Message Export Report will create a zip file of XML and text-based logs intended for Dell Technical Support assistance with troubleshooting system issues.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RAC0676 Message Unable to assign physical disk drives as global hotspare(s). Detailed Description Unable to assign physical disk drives as global hotspare(s). This may be because there are no disk drives available in a ready state or there are no virtual disks present.
Detailed Description Unable to perform Prepare to Remove or Secure Erase operations on the PCIe SSD disk drives. Recommended Response Action Make sure PCIe SSD disk drives are inserted into the enclosure or attached to the backplane and retry the operation. If the issue persists, contact your service provider. Category Storage (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0679 Message A job operation is already running.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0680 Message Server iDRAC user credentials and/or BIOS passwords are not currently set to default credentials. The USB Configuration XML feature is not available unless default credentials are set. Detailed Description The USB Configuration XML feature is not available if the iDRAC user credentials and BIOS passwords are not set to default values.
Detailed Description Enabling iDRAC Direct USB Configuration XML allows any USB key containing a correctly formatted configuration XML file to reconfigure the server when plugged into the USB management port identified by the wrench icon. This may include operations on RAID configurations, user accounts, and alert settings. Recommended Response Action No response action is required.
RAC0685 Message A pending operation has been created for this arg1 operation. Arguments arg1 = task name Detailed Description A pending operation has been created for this operation identified in the message. Recommended Response Action To view the pending operations click the Pending Operations button. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0686 Message Some of the applied pending operations were not created.
RAC0688 Message Applying this configuration operation will also apply all existing pending operations on the arg1 . #{View Pending Operations link} Arguments arg1 = controller_name Detailed Description Applying this configuration operation will also apply all existing pending operations on the controller identified in the message. Recommended Response Action Click Create Job button to create the configuration job. Click Cancel to quit job creation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RAC0690 Message The iDRAC Service Module is not installed on the operating system of the server. Detailed Description The iDRAC Service Module is not installed on the operating system of the server. Recommended Response Action Install the iDRAC Service Module and retry the operation.
Detailed Description Pending operations are created for the selected operations on the selected physical disk drives. Recommended Response Action To view the pending operations, click the Pending Operations button. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0694 Message Unable to configure the attributes of the selected controller, because Lifecycle Controller is not enabled.
Detailed Description The iDRAC is unable to retrieve hardware overview related information while the server is turned off. Recommended Response Action Turn the server on to view the hardware overview information. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0697 Message Choose to create a job from the existing successfull pending operations.
Recommended Response Action Enter a value between -. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC070 Message The SSL Web-Server certificate was successfully restored to factory defaults. Detailed Description The SSL Web-Server certificate was successfully restored to factory defaults. Recommended Response Action No response action is required.
RAC0701 Message Requested system powerup. Detailed Description Requested system powerup. Recommended Response Action No response action is required. Category Audit (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RAC0702 Message Requested system powercycle. Detailed Description Requested system powercycle.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0703 Message Requested system hardreset. Detailed Description Requested system hardreset. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0705 Message Requested system graceful shutdown. Detailed Description Requested system graceful shutdown. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0707 Message Primary Firmware image is invalid. Currently booted from backup image. To restore primary image, update the firmware. Detailed Description Primary Firmware image is invalid. Currently booted from backup image. To restore primary image, update the firmware. Recommended Response Action Acquire an iDRAC firmware image of the version desired. Using the latest version available is recommended.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RAC0709 Message Unknown server inserted into chassis. Detailed Description Unknown server inserted into chassis. Recommended Response Action Acquire the latest Chassis Management Controller (CMC) firmware that supports the server indicated and update the CMC to at least that version.
Severity Severity 3 (Informational) No alerts are applicable for this message RAC0710 Message Server link tuning error. Detailed Description Server link tuning error. Recommended Response Action Ensure that the IO Module (IOM) and Mezzanine (Mezz) cards are appropriately matched. Check the M1000e Hardware Manual for correct component compatibility.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0712 Message Server failed to power up due to zero power allocated. Detailed Description Server failed to power up due to zero power allocated. Recommended Response Action Utilize the Chassis Management Controller web interface to check available power and server power requirements. If sufficient power is available, allocate power necessary and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0714 Message Server failed to power up due to noncontinuous power action. Detailed Description Server failed to power up due to noncontinuous power action. Recommended Response Action Utilize the Chassis Management Controller web interface to check available power and server power requirements. If sufficient power is available, allocate power necessary and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0716 Message Unable to unmount remote share. Detailed Description Unable to unmount remote share. Recommended Response Action Retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0718 Message Remote File Share service is busy with the previous connection. Detailed Description Remote File Share service is busy with the previous connection. Recommended Response Action Stop the Remote File Share session and retyr the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC072 Message Unable to perform the iDRAC reset to factory defaults operation because the firmware upgrade is in progress. Detailed Description The iDRAC reset to factory defaults operation cannot be completed because a firmware upgrade operation is in progress. Recommended Response Action Wait for the current update process to complete and retry the operation.
RAC0721 Message Remote share mounted successfully arg1 . Arguments arg1 = sharename Detailed Description Remote share mounted successfully. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0723 Message The firmware version arg1 of the Chassis Management Controller is earlier than the required version arg2 . Arguments arg1 = version number, arg2 = version number Detailed Description The Chassis Management Controller firmware version identified in the message is earlier than the version required to support the server.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0725 Message Unable to update the Quick Sync Firmware. Detailed Description Unable to update the Quick Sync Firmware. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC0727 Message Auto-throttling is enabled for the server. Detailed Description Auto-throttling is enabled for the server based on a request from the Chassis Management Controller (CMC) because the CMC has restarted. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RAC073 Message Unable to perform the iDRAC reset operation because a vFlash partition creation operation is in progress. Detailed Description The iDRAC reset operation cannot be completed because a vFlash partition creation operation is in progress.
Detailed Description The Prepare to Remove operation will stop any activity on the PCIe SSD device so that it can be removed safely. The device is safe to remove when the disk shows the safe to remove LED pattern. Recommended Response Action Press OK to continue.
RAC0743 Message Unable to perform storage configuration operations because no storage controllers are detected on the server. Detailed Description Unable to perform storage configuration operations because no storage controllers are detected on the server Recommended Response Action No response action is required.
RAC0746 Message Unable to perform virtual disk (VD) operations, because Lifecycle Controller is not enabled. Detailed Description Unable to perform virtual disk(VD) operations, because Lifecycle Controller is not enabled. Recommended Response Action Enable the Lifecycle Controller and retry the operation. To enable Lifecycle Controller, restart the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC0749 Message SNMPv3 User cannot be set to None. Detailed Description SNMPv3 User cannot be set to None. Recommended Response Action Set the SNMPv3 User to a value other than None and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC0751 Message The threshold value entered is less than the lower warning or critical threshold. Detailed Description The value for information or warning threshold should not be less than lower critical threshhold value.
Recommended Response Action Click the Reset iDRAC link to reset iDRAC. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0754 Message Reset iDRAC to complete the deletion action of the certificate. Detailed Description Reset iDRAC to complete custom SSL certificate deletion action. A manual reset of iDRAC is needed for the action to take effect. Recommended Response Action Click the Reset iDRAC link to reset iDRAC.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0757 Message USB Management Port is currently disabled in BIOS configuration. Detailed Description The requested operation using the USB Management Port cannot be completed because the port is disabled in BIOS configuraton.
Severity Severity 2 (Warning) No alerts are applicable for this message RAC0760 Message Unable to perform physical disk(s) storage configuration operations for the selected controller. Detailed Description Unable to perform storage configuration operations on physical disk drive(s) as there are no disk drive(s) available with Ready/RAID/NON-RAID state or the selected controller is in HBA mode.
Recommended Response Action Make sure that a valid catalog file is available on the network share and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC0763 Message Unable to configure the port number that is entered because the port number is already in use.
to permit usage of iDRAC plugins such as vConsole with this higher level of encryption. NOTE: Using this level of encryption may have import or export implications. For more guidance, contact your legal department. Detailed Description Selecting a higher SSL encryption enhances the security.
Arguments arg1 = IP address Detailed Description The USB NIC IP address identified in the message cannot be assigned to the OSBMC device because only Link Local IP address can be allowed. Recommended Response Action Enter appropriate Link Local IP address, and then retry the operation. For information about supported IP addresses, refer to the iDRAC Users Guide available at the support site.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RAC0901 Message Invalid syntax. The -t option value must set to 1. Detailed Description The syntax of the specified command is invalid. In this case, the usage of the -t option is invalid. Recommended Response Action See the help text/documentation for the valid syntax of the subcommand.
No alerts are applicable for this message RAC0904 Message The remote file location is not accessible or reachable. Detailed Description The iDRAC cannot access the remote file location. The credentials or path to the remote file location is incorrect or iDRAC cannot connect to the network address. Recommended Response Action Confirm that the path and credentials to remote file are correct, and check that the iDRAC can connect to the network address.
RAC0907 Message System ID LED blink on. Detailed Description The System ID LED was successfully set to on. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC0908 Message System ID LED blink off. Detailed Description The System ID LED was successfully set to off. Recommended Response Action No response action is required.
RAC0910 Message Invalid subcommand syntax: Specify group and object name. Detailed Description The specified command is missing group and object name syntax. Recommended Response Action Specify the correct subcommand group and object name syntax. See the help text or documentation for the valid syntax. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC0911 Message Data about version details is unavailable.
RAC1000 Message Unable to set the object value for iDRAC IPv6 address or gateway. Detailed Description Unable to set the object value for iDRAC IPv6 Address1 and IPv6 Gateway, because the object IPv6 Autoconfig is enabled. Recommended Response Action Disable the object IPv6 AutoConfig using "racadm set iDRAC.IPv6.AutoConfig <0 | Disabled >", and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1002 Message Active Directory Single Sign On (SSO) cannot be enabled. Detailed Description The Active Directory SSO cannot be enabled, because the object SmartCardLogonEnable is enabled. Recommended Response Action Disable the object SmartCardLogonEnable using "racadm set iDRAC.SmartCard.LogonEnable <0 | Disabled>", and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1004 Message The smart card login cannot be enabled. Detailed Description The smart card login cannot be enabled, because the Active Directory Single Sign On is enabled. Recommended Response Action Disable Active Directory Single Sign On (SSO) using "racadm set iDRAC.ActiveDirectory.SSOEnable <0 | Disabled>", and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1006 Message Unable to process the arg1 , and the update was not applied. Arguments arg1 = file name Detailed Description The update was not applied because of one of the following reasons: 1) The Update Package is invalid. 2) Lifecycle Controller is corrupted. 3) Another update is in progress.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1008 Message The Active Directory object DCLookupByUserDomain cannot be disabled. Detailed Description The Active Directory object DCLookupByUserDomain cannot be disabled, because the Active Directory object DCLookupDomainName is not configured.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1010 Message Unable to set the power cap value. Detailed Description The power cap cannot be set if the object Power.Cap is disabled. Recommended Response Action Enable Power Cap setting using "racadm set System.Power.Cap.
Recommended Response Action Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection ", and retry the opeation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1012 Message Unable to change the auto-negotiation state for the current NIC selection mode.
Detailed Description For any iDRAC user, SNMPv3 authentication protocol can be changed to "None" only if the SNMPv3 privacy protocol state is set to "None". Recommended Response Action Change the SNMPv3 privacy protocol state to None using "racadm set iDRAC.Users..SNMPv3PrivacyType none", and retry the operation.
RAC1016 Message The specified user already exists. Duplicate user names are not allowed. Detailed Description iDRAC does not allow duplicate user names for each of the 16 users. Recommended Response Action Make sure that each of the 16 user names are unique.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1018 Message The specified object or syntax is invalid. Detailed Description This occurs when an incorrect syntax is used or an incorrect object is specified during the command invocation. Recommended Response Action Make sure to use the correct syntax and correct object names, and retry the operation. For information related to the corresponding group, see RACADM help or the RACADM Users Guide.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1020 Message No objects are available under the specified group for the current system configuration. Detailed Description Some objects have dependencies on other objects that are required to perform a task. The specified group does not contain any objects, because the dependent objects are not part of the current system configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1023 Message Unable to create the configuration job. Detailed Description Configuration jobs are created only if at least one object on the device or component (for example, NIC.Slot.1 or BIOS) has a pending value to be applied.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1025 Message The specified object is read-only and cannot be modified due to an object dependency. Detailed Description Some objects have dependencies on other objects that are required to perform a task.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1027 Message Successfully sent the alert for the specified event to the configured destination. Detailed Description A test event was generated and the alert was successfully sent to the destination.
Recommended Response Action Make sure to specify either "1", "2", or "3" for the certificate type (-t) option, and retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1029 Message Unable to delete the specified certificate type.
Detailed Description The custom signing certificate present on iDRAC was deleted. Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1031 Message Unable to delete the custom signing certificate.
RAC1032 Message arg1 jobs was cancelled by the user. Arguments arg1 = Job ID or ALL Detailed Description The job specified in the message were cancelled.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1034 Message This action will ungracefully turn off the server. Detailed Description This operation will cause the server to shutdown immediately. This may result in the applications losing data. Recommended Response Action Before continuing, exit all the programs running on this server, and make sure that there is no inbound and outbound traffic associated with this server.
RAC1036 Message Successfully cleared pending attribute(s) for the group specified. Detailed Description Successfully cleared pending values for attributes in the group specified. Recommended Response Action To verify, run the RACADM command "racadm get group". Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC1037 Message Unable to clear pending attribute(s). Detailed Description Unable to clear pending attribute(s).
Recommended Response Action Make sure that a config job is not scheduled for this component. For more information, view the help command by running the RACADM command "racadm jobqueue help delete".
Detailed Description The requested RAID storage operation was successfully accepted and now must be applied by creating a RAID storage configuration job. Recommended Response Action To apply the configuration operation, create a configuration job, and then restart the server. To create the required commit and reboot jobs, run the jobqueue command. For more information about the jobqueue command, enter the RACADM command "racadm help jobqueue".
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1043 Message Unable to configure the Automatic Update (autoupdate) feature settings. The option arg1 is either invalid or not provided.
Recommended Response Action To enable, run the RACADM command "racadm set lifecyclecontroller.lcattributes.autoupdate 1". Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1045 Message Specifying ftp.dell.
RAC1046 Message Unable to view the Automatic Update (autoupdate) feature settings because the feature has not been configured. Detailed Description Unable to view the Automatic Update (autoupdate) feature settings because the feature has not been configured. Recommended Response Action Configure the Automatic Update feature by running the RACADM command "racadm autoupdatescheduler create" with the desired option settings.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1048 Message Unable to clear the Automatic Update (autoupdate) feature settings because there is currently no configuration. Detailed Description The Automatic Update (autoupdate) feature settings must already exist in order to be cleared. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1050 Message Unable to configure the Automatic Backup (autobackup) feature settings. The required options are either invalid or not provided. Detailed Description One or more required options to configure the Automatic Backup (autobackup) feature are missing.
Recommended Response Action Retry with a correct value for the option identified in the message. For more information, view the help details by running the RACADM command "racadm help systemconfig backup".
Detailed Description Unable to view the Automatic Backup (autobackup) feature settings because the feature has not been configured. Recommended Response Action Configure the Automatic Backup feature by running the RACADM command "racadm systemconfig backup" with the desired option settings.
RAC1055 Message Unable to clear the Automatic Backup (autobackup) feature settings because there is currently no configuration. Detailed Description The Automatic Backup (autobackup) feature settings must already exist in order to be cleared.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1057 Message Rollback operation did not complete successfully. The component identifier specified is not valid or does not have a rollback firmware image available. Detailed Description Rollback operation did not complete successfully. The component identifier (FQDD) specified in the operation is not valid or does not have a Rollback firmware image available.
RAC1059 Message Rollback operation could not be performed because another firmware update job is running. Detailed Description The requested firmware rollback operation could not be performed because another firmware update job is running or being scheduled. Recommended Response Action Wait until the existing firmware update jobs are completed or scheduled before retrying the operation. To monitor the status of the existing jobs, run the RACADM command "racadm jobqueue view".
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1061 Message SystemErase operation initiated successfully. Detailed Description The requested SystemErase operation was initiated successfully. Recommended Response Action Check the job status by running the RACADM command: "racadm jobqueue view -i ".
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1063 Message Unable to initiate the SystemErase operation because Lifecycle Controller is disabled. Detailed Description Unable to initiate the SystemErase operation because Lifecycle Controller is disabled. Recommended Response Action Run the RACADM command "racadm set LifecycleController.LCAttributes.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1065 Message Unable to initiate the SystemErase operation because iDRAC encountered an internal issue. Detailed Description Unable to initiate the SystemErase operation because iDRAC encountered an internal issue.
Detailed Description The minimum non critical threshold value identified in the message cannot be set, because the value entered is lesser than, or equal to the minimum critical threshold value. Recommended Response Action Check the minimum critical threshold level using an appropriate RACADM command. For example, to view the minimum threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1069 Message Unable to set minimum non critical threshold value of arg1 , because the value entered is greater than, or equal to the maximum critical threshold value. Arguments arg1 = System Board Inlet Temp Detailed Description The minimum non critical threshold value identified in the message cannot be set, because the value entered is greater than, or equal to the maximum critical threshold value.
retry the operation. For more information about other RACADM commands, run the racadm help command.
RAC1072 Message Unable to set maximum non critical threshold value of arg1 , because the value entered is less than, or equal to the minimum critical threshold value. Arguments arg1 = System Board Inlet Temp Detailed Description The maximum non critical threshold value identified in the message cannot be set, because the value entered is less than or equal to the minimum critical threshold value.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1109 Message Unable to run the command, because an incorrect Share type is entered. Detailed Description Unable to run the command, because an incorrect Share type was entered. Recommended Response Action Enter an appropriate Share location of the following types: FTP, NFS, or CIFS.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1111 Message Unable to delete the pending values or operations of the specified device. Detailed Description Unable to clear pending values or operations from the specified storage device because there are no pending operations for the specified device.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1113 Message Unable to perform the preview operation because the options -b, -c, -w, and -s must not be used with the --preview option.
Recommended Response Action Monitor the status of the preview operation job by running the racadm command "racadm jobqueue view -i ". Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1115 Message Unable to run the command, because of insufficient user privileges.
Detailed Description The command could not be successfully run, because an incorrect "restart flag" value was entered in the command. Recommended Response Action Enter a correct flag value. The recommended values are "true" and "false". Make sure that you have entered the correct value, and then retry the operation.
RAC1118 Message Successfully initiated the update operation specified in the command. Detailed Description Successfully initiated the update operation specified in the command. Recommended Response Action To know about the status of a command that is initiated, run the following command: racadm jobqueue view -I .
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1120 Message Unable to run the command, because an incorrect Proxy type is entered. Detailed Description The command could not be successfully run, because an incorrect Proxy type value was entered for the -pt option. Recommended Response Action Make sure that you entered either "http" or "https" as the proxy type. Enter the correct type, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1122 Message The specified group or object is not supported on the server. Detailed Description One or more of the group or component attributes specified in the operation do not exist on the targeted server. Recommended Response Action No response action is required.
Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1128 Message The -l option must be specified if -u and -p options are used. Detailed Description Any operation involving remote share (CIFS) cannot continue if the location (-l option) is not specified.
Recommended Response Action Configure the FirstBootDevice object to values other than F10, F11, or BIOS and retry the set operation for the BootOnce object. For more information about possible FirstBootDevice values, run the RACADM command "racadm help idrac.serverboot.firstbootdevice".
RAC1131 Message iDRAC was successfully reset. Detailed Description The iDRAC was reset and is successfully restarted. Recommended Response Action None. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1132 Message Unable to update the firmware.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1133 Message BIOSRTDRequested value is modified successfully.The BIOS reset to default values operation is pending a server restart. Detailed Description The BIOSRTDRequested attribute was modified successfully.The BIOS reset to default values operation is pending a server restart. Recommended Response Action To apply the BIOS default values, restart the server.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1135 Message Unable to run the RACADM command because an internal instrumentation component has stopped functioning. Detailed Description The RACADM command could not be run because the internal instrumentation components are either busy or have stopped functioning.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RAC1137 Message Remote unattended diagnostic results export operation initiated. Detailed Description Remote unattended diagnostic results export operation initiated.
Recommended Response Action Using the RACADM command line interface, run the "racadm diagnostics run" command to make sure that the diagnostics results are available, and then retry the operation.
Detailed Description The file name cannot be specified when the Technical Support Report (TSR) is exported to a remote share. Recommended Response Action Run the command without using the -f option. For more information on exporting Technical Support Report (TSR), run the command racadm help techsupreport export.
RAC1142 Message Unable to start the Remote Diagnostics operation because the Expiration Time entered (difference between Start Time and Expiration Time) is less than five minutes. Detailed Description The Remote diagnostic operation cannot be performed because the difference between "Start Time" and "Expiration Time" is less than 5 minutes. Recommended Response Action Make sure that the Expiration Time is greater than five minutes, and then retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1144 Message The Job: arg1 is invalid or is not present in the job queue and a related Lifecycle Log entry is not found. Arguments arg1 = job ID Detailed Description No configuration results information is available for the job ID identified in the message because the job ID is invalid or is not present in the job queue and a related Lifecycle Log entry is not found.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1146 Message Unable to set the SNMPv3 username because SNMPv3 is not enabled for the specified user on iDRAC. Detailed Description The SNMPv3 username cannot be set because SNMPv3 is not enabled for the specified user on iDRAC.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1150 Message Unable to complete the export operation. Detailed Description The export operation did not be complete successfully. Recommended Response Action Retry the export operation after five minutes.
Recommended Response Action Run the RACADM techsupreport collect command again and then retry the export operation. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1152 Message The export operation completed successfully.
Detailed Description The time stamp was not recorded for the previous techsupreport collect operation. Recommended Response Action Run the RACADM techsupreport collect command. After the techsupreport collect operation completes, run the RACADM getupdatetime command.
RAC1155 Message Unable to complete the operation because Lifecycle Controller is disabled. Detailed Description The operation was not completed because Lifecycle Controller is disabled. Recommended Response Action Enable the Lifecycle Controller and retry the operation. To enable Lifecycle Controller, run the command racadm set LifeCycleController.LCAttributes.LifecycleControllerState 1.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1157 Message Unable to find the specified FQDD. Detailed Description The specified FQDD is invalid. Recommended Response Action Verify whether or not the entered FQDD is valid. Run the command racadm gethostnetworkinterfaces for the list of valid FQDDs.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1159 Message Unable to get the requested data from iDRAC. Detailed Description The data cannot be retrieved from iDRAC because Lifecycle Controller is disabled or a DUP update is in progress. Recommended Response Action Do the following: 1) Check if a DUP fw update is progress and wait until it is finished.
Recommended Response Action Contact the iDRAC system administrator and get the System Control privilege added to the account identified in the message or use account credentials that have System Control privilege and retry the operation.
Detailed Description The requested techsupreport collect operation cannot be initiated because another techsupreport collect operation for the Tech Support Report (TSR) is in progress. Recommended Response Action Wait for the current collect operation to complete before initiating another collect operation. To view the status of the techsupreport collect operation, run the command racadm jobqueue view.
RAC1164 Message A remote diagnostics operation is currently running and not completed. Detailed Description A remote diagnostics operation is already under execution and another operation can be started only after the current execution is completed. Recommended Response Action Initiate another diagnostics operation only after the currently running operation is completed.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1166 Message Successfully initiated Configuration XML file preview operation that was invoked by arg1 . Arguments arg1 = user name Detailed Description The Configuration XML file preview operation was successfully initiated after it was invoked by the user name identfied in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1169 Message The RACADM "config" command will be deprecated in a future version of iDRAC firmware. Detailed Description The RACADM "config" command will be deprecated in a future version of iDRAC firmware. Recommended Response Action Run the RACADM "racadm set" command to configure the iDRAC configuration parameters.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1175 Message Unable to change the user configuration because modifying the user configuration at index 1 is not allowed. Detailed Description The user configuration cannot be modified, because modification is not allowed at index 1.
Recommended Response Action Make sure that all the attributes in the iDRAC.Security group are configured. To get the list of attributes, run the following command "racadm get iDRAC.Security".
Detailed Description A USB device is attached to the iDRAC and a configuration XML import operation is in progress. Recommended Response Action Wait until the configuration XML import operation has completed before attempting another operation. Verify the status of the configuration XML import operation by running the RACADM command "racadm jobqueue view".
RAC1180 Message A USB device is inserted in the front panel USB Management port and is in use by the server operating system. Detailed Description A USB Device inserted in the front panel USB Management port and is in use by the server operating system. The device needs to not be in use in order to change the port mode settings. Recommended Response Action Remove and reinsert the USB device and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1182 Message Unable to retrieve information for the Power group or attribute because the server is not PMBus capable. Detailed Description The server instrumentation can not provide any information related to power because PMBus capability is not present or the PSU(s) with PMBus capability have been removed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1184 Message The getuscvresion RACADM subcommand will be deprecated in a future release. Detailed Description The getuscvresion RACADM subcommand will be deprecated in a future release. Recommended Response Action Instead of getuscversion, run the getversion -f lc subcommand.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1186 Message 1000Mbps speed setting is Read Only and cannot be configured for the iDRAC NIC. Detailed Description Only possible configurations for the DRAC NIC are 10Mbps and 100 Mbps. For documentation with respect to this setting, refer to the racadm User Guide under cfgNetTuning group.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC1188 Message Unable to configure the Upper Non-Critical value for the System Performance sensor. Detailed Description Unable to configure the Upper Non-Critical value for the System Perfromance sensor because the value provided is not in vaild range. Recommended Response Action Specify a value in the range of 0 to 100 to set the upper non-critical value.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC802 Message iDRAC time is set using Network Time Protocol. Detailed Description iDRAC time has been set through Network Time Protocol (NTP). Recommended Response Action No response action is required.
No alerts are applicable for this message RAC914 Message Value specified is invalid: Must be 0 (Off) or 1 (On). Detailed Description The specified value is not within the valid range. To set the LED state to off, enter 0. To set the LED state to on, enter 1. Recommended Response Action Set the numeric value to 0 (Off) or 1 (On).
RAC917 Message The syntax of the specified command is not correct. Detailed Description The syntax of the specified command is incorrect. Recommended Response Action See the command help text. To see the help text, run "racadm help ". Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC918 Message Unable to get the inlet temperature data. Detailed Description Racadm unable to obtain the inlet temperature data.
RAC920 Message This interface does not support the specified option. Detailed Description From firmware racadm, the inlet temperature history can be exported only to a remote file share. Recommended Response Action Create a remote file share to export the inlet temperature history. Else, use remote/ local racadm to export to the file system accessible by the racadm executable.
RAC923 Message The file path is too long. Detailed Description The specified file path (specified with the f parameter) is too long. This path should be less than 64 characters in length. Recommended Response Action Try the same command with a shorter file path (specified with the f parameter) which is less than 64 characters in length.
RAC926 Message The recurrence interval needs to be an integer from 0 to 365. Detailed Description The value given for the recurrence interval is invalid. It has to be a value from 0 to 365. Recommended Response Action Change the argument of r to a value from 0 to 365 and then run the same command. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) No alerts are applicable for this message RAC927 Message Recurrence value modified successfully.
RAC929 Message Invalid category or subcategory specified. Detailed Description The category or subcategory specified is incorrect. The recurrence interval is applicable only to the TMPS subcategory and system category. Recommended Response Action See the command help text, for a list of valid categories. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) No alerts are applicable for this message RAC930 Message Unable to export the inlet temperature data.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC937 Message Successfully initiated configuration XML file import operation that was invoked by the arg1 . Arguments arg1 = user name Detailed Description The configuration XML file import operation was successfully initiated after it was invoked by the user specified in the message.
Recommended Response Action No response action is required. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RAC939 Message Unable to start the system configuration profile export or import operation.
Detailed Description If an existing system profile import or export job is running, then a system configuration profile backup or restore opeartion cannot be started. Recommended Response Action Wait until the existing system profile export or import job is completed or cancel the job before retrying the operation.
RAC942 Message Successfully initiated the import operation. This operation may take several minutes to complete and may cause multiple system restarts while device firmware and configuration are applied. Detailed Description The system configuration profile import operation is initiated. No other operations can be performed on the system while the system configuration server profile is being imported from the system configuration profile.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC944 Message Unable to create the configuration job. Detailed Description A configuration job cannot be created if Lifecycle Controller is disabled. Recommended Response Action Run "racadm set LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle Controller, and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC946 Message Unable to set the NIC to Auto Dedicated NIC mode. Detailed Description The "Auto Dedicated NIC" mode cannot be set for a NIC if the NIC selection mode is set to "Dedicated NIC". Recommended Response Action To set the NIC to Auto Dedicated NIC mode, set NIC selection mode to "Shared NIC", and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC948 Message Unable to send the notification for the specified event to the configured destination. Detailed Description A test event notification for the specified message ID was not sent to the configured destination. Recommended Response Action Make sure to the use a valid message ID, set the required notification filter, and retry the operation. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC950 Message Unable to add the work note to the Lifecycle Log. Detailed Description The work note cannot be added to the Lifecycle Log if iDRAC is archiving the older records in the Lifecycle Log. Recommended Response Action Wait for several minutes while iDRAC archives the older records, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC952 Message There is no free space to add new work notes to the Lifecycle Log. Detailed Description The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further work notes can be added to the Lifecycle Log. Recommended Response Action Contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC954 Message The number of characters entered for the comment exceeds the supported limit. Detailed Description Up to 128 characters are allowed for a comment. Recommended Response Action Do not exceed 128 characters for the comment, and retry the operation.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC956 Message There is no free space to add new comments to the Lifecycle Log. Detailed Description The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further comments can be added to the Lifecycle Log.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC958 Message Unable to start the import or export operation. Detailed Description An import or export operation cannot be started until the current running job is complete.
Recommended Response Action Correct the modifications to the configuration XML file to be imported or specify the correct file, and retry the operation. Check the Lifecycle Log for more details.
Detailed Description Another import operation cannot be started if an import operation that was performed earlier has some pending or commited configuration changes. Recommended Response Action Wait until the configuration changes are applied before starting another import operation. Use the racadm jobqueue view command to check the status of the current import operation.
RAC963 Message Unable to retrieve the status of Lifecycle Controller. Detailed Description iDRAC is unable to read Lifecycle Controller status. Lifecycle Controller must be enabled to run the operation. Recommended Response Action Run the racadm get LifeCycleController.LCAttributes.LifecycleControllerState command to get the status of the Lifecycle Controller. If the issue persists, contact your service provider.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC965 Message The -l option must be specified if -u and -p are used. Detailed Description Any operation involving remote share (CIFS) cannot continue if the location (-l) is not specified. The u and p options represent the user name and password for the remote share, and -l represents the location of the remote share.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC967 Message Exporting the configuration XML file to a local share is not supported when using Firmware RACADM. Detailed Description The configuration XML file can only be exported to a remote share while using Firmware RACADM.
Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC969 Message Incorrect value specified for the shutdown option. Detailed Description The import operation cannot continue if the value specified for the shutdown option (-b) is incorrect. The supported values are "Graceful" and "Forced".
Recommended Response Action Make sure to specify either "On" or "Off" for the end power state (-s) option. Category Configuration (RAC = RAC Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC971 Message Incorrect file type specified.
Detailed Description Configuration XML import and export operations require the specified username to have administrator role privileges. Recommended Response Action Run the same command with a username that has an administrator role privileges.
RAC974 Message Invalid wait time specified. Detailed Description The value specified for the wait time (w) option is invalid. The valid range is 300 to 3600 seconds. Recommended Response Action Make sure to specify a valid wait time (-w) option and retry the command. The range of supported values are 300 to 3600 seconds.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC976 Message Export configuration XML file operation initiated. Detailed Description The configuration XML file export operation was initiated. Recommended Response Action Use the racadm jobqueue view i command to view the status of the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC978 Message Unsupported Lifecycle Controller firmware version detected. Detailed Description The Lifecycle Controller firmware version on the target system does not support the configuration XML file import or export operations. Recommended Response Action Update to the latest Lifecycle Controller firmware and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC981 Message The type of certificate specified does not require a passphrase. Detailed Description A passphrase is required only for passphrase protected certificate, which is specified using the value of 3 for the -t option. Recommended Response Action If the file being uploaded is passphrase protected, specify the file type as 3 using the -t option.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC983 Message Invalid passphrase provided for the Public Key Cryptography Standards version 12 (PKCS12) file. Detailed Description The Public Key Cryptography Standards version 12 (PKCS12) file is passphrase protected, and the passphrase provided is invalid. Recommended Response Action Specify the correct passphrase for the file using -p option.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC985 Message Unable to configure the cfgServerBootOnce object. Detailed Description The object "cfgServerBootOnce" cannot be configured if the object "cfgServerFirstBootDevice" is set to F10, F11, or BIOS value.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC987 Message Firmware update job for arg1 is initiated. Arguments arg1 = file name Detailed Description After initiating the firmware update job, the time taken to complete it depends on size of the update file.
Recommended Response Action Wait until the existing firmware update jobs are completed or scheduled before retrying the operation. To monitor the status of the existing jobs, use the "racadm jobqueue view" command.
RAC990 Message Unable to apply the arg1 update. Arguments arg1 = file name Detailed Description If Lifecycle Controller is disabled, the firmware update operation cannot continue. Recommended Response Action Enable Lifecycle Controller using the "racadm set lifecyclecontroller.lcattributes.lifecyclecontrollerstate 1" command, and retry the operation.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC992 Message Invalid job: arg1 . Arguments arg1 = job ID Detailed Description The job ID specified in the message is invalid or was already deleted. Recommended Response Action To monitor the current set of the jobs, use the "racadm jobqueue view" command.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC994 Message Unable to run the "jobqueue delete --all" command. Detailed Description The jobs cannot be deleted if they are in one of these states: "Scheduled" or "Running". However, all jobs in one of these states: "Completed" or "Failed" will be deleted.
no other hardware inventory operation was in progress, reboot the iDRAC using "racadm racreset" command and then retry the operation. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC996 Message Unable to set the object value because the DNS RAC Name object is not configured.
Recommended Response Action Make sure that IPv4 and IPv4 DHCP are enabled, or IPv6 and IPv6 AutoConfig are enabled. Category Configuration (RAC = RAC Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC RAC998 Message IPv6 cannot be enabled. Detailed Description IPv6 cannot be enabled if iDRAC NIC is disabled.
Detailed Description DNSFromDHCP6 cannot be enabled if iDRAC IPv6 AutoConfig is disabled. Recommended Response Action Enable IPv6 AutoConfig using "racadm set iDRAC.IPv6.AutoConfig < 1 | Enabled >" command, and retry the operation.
RDU Event Messages RDU0001 Message The fans are redundant. Detailed Description None Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC RDU0003 Message Fan redundancy is degraded. Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans. Recommended Response Action Remove and re-install failed fans or install additional fans.
Recommended Response Action Remove and re-install failed fans or install additional fans. Category System Health (RDU = Redundancy) Severity Severity 3 (Informational) Trap/EventID 2475 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC RDU0005 Message The fans are not redundant. Insufficient resources to maintain normal operations.
RDU0011 Message The power supplies are redundant. Detailed Description None Recommended Response Action No response action is required.
OMSA Trap ID 5306 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy RDU0013 Message Power supply redundancy is degraded. Detailed Description The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change.
Detailed Description The current power supply configuration does not meet the platform requirements to enable redundancy. If a power supply fails the system may shut down. Recommended Response Action If unintended, review system configuration and power consumption and install power supplies accordingly. Check power supply status for failures.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* RDU0016 Message The storage voltage is redundant. Detailed Description The storage voltage is redundant.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* RDU0018 Message The storage power redundancy is degraded. Detailed Description The storage system has multiple redundant power lines. One or more of these power lines is no longer available.
Severity Severity 3 (Informational) Trap/EventID 2475 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* RDU0020 Message Power supply redundancy is disabled. Detailed Description Redundancy is not currently enabled for the power supplies. Recommended Response Action No response action is required.
Recommended Response Action Replace the failed power supply with a new power supply. Category System Health (RDU = Redundancy) Severity Severity 2 (Warning) OMSA Event ID 5301 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RDU0022 Message Fan redundancy is disabled. Detailed Description Redundancy is not currently enabled for the fans.
RDU0023 Message Unable to determine the redundancy status of the fans. Detailed Description One or more fans are non-functional or may have failed. Recommended Response Action Check that all fans are working properly. Replace any non-fuctional fan with a new fan.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* RDU0031 Message The arg1 voltage redundancy is lost. Arguments arg1 = name Detailed Description The system has redundant voltage lines. One of voltage line is no longer available. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) If the issue still persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* RDU0033 Message The arg1 voltage is not redundant.
Recommended Response Action No response action is required. Category Audit (RDU = Redundancy) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8501 Message CMC arg1 : waiting to be reset by other CMC Arguments arg1 = slot number Detailed Description The Active CMC has detected a problem or a low memory condition.
Arguments arg1 = slot number Detailed Description For failover to occur, the standby CMC needs to be present, at the same version as the primary and healthy. During failover, the active CMC resets and the standby CMC becomes active. This message is logged when the standby CMC is absent, unhealthy or at a different firmware version. Recommended Response Action Check the status of the standby CMC and make sure the firmware version matches the primary CMC. Then reseat the CMC and retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RDU8507 Message CMC arg1 : disable failover Arguments arg1 = slot number Detailed Description CMC failover is disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8509 Message CMC arg1 : cannot failover, chassis is in non-redundant state Arguments arg1 = slot number Detailed Description For failover to occur, the standby CMC needs to be present, at the same version as the primary and healthy. During failover, the active CMC resets and the standby CMC becomes active.
Recommended Response Action Check the status of the standby CMC and make sure the firmware version matches the primary CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service provider.
RDU8512 Message CMC arg1 : firmware versions are different [ arg2 arg3 : arg4 arg5 ] Arguments arg1 = slot number, arg2 = local fw version, arg3 = factory revision, arg4 = remote version, arg5 = factory revision Detailed Description The firmware versions of the Active CMC and the Standby CMC are different. Recommended Response Action Update the firmware so that the Active and Standby CMC firmware versions are the same.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RDU8514 Message CMC arg1 : cannot failover, firmware update is in progress. Arguments arg1 = slot number Detailed Description A failover operation has been requested, but a failover operation cannot be completed while CMC firmware update is in progress. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8516 Message CMC arg1 : failover initiated by RACADM interface. Arguments arg1 = slot number Detailed Description A failover has been requested from the RACADM command line interface. Recommended Response Action No response action is required.
Category Audit (RDU = Redundancy) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* RDU8518 Message CMC arg1 : active CMC arg2 requests Standby CMC to go active state. Arguments arg1 = slot number, arg2 = slot number Detailed Description The active CMC requests the Standby CMC to go active.
Recommended Response Action Wait for 10 minutes for: 1)Firmware update operations to complete and 2) The CMC to finish restarting. If the communication is not reestablished, remove and reinsert the CMC.
Arguments arg1 = slot number Detailed Description The active CMC has been removed from the chassis. If standby CMC is present, it will become active. Recommended Response Action Reinstall the CMC that was removed.
RDU8523 Message CMC arg1 : reset by peer CMC Arguments arg1 = slot number Detailed Description The CMCidentified in the message was reset by other CMC. This occurs during failover and CMC firmware update to the standby CMC. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* 1508 LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔*
RED Event Messages RED000 Message Unrecognized error code encountered. Detailed Description An unknown error was returned. Recommended Response Action Check the uniform resource identifier (URI) target path and make sure the repository server is available.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RED002 Message Package successfully downloaded. Detailed Description Package has been successfully downloaded. The Job Scheduler will schedule it at the time specified. Recommended Response Action Schedule the job if it is not already scheduled.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED004 Message The job cannot be run because of an unknown issue. Detailed Description The job cannot be run because of an unknown issue. Recommended Response Action Check the uniform resource identifier (URI), target path and make sure the repository server is available.
Severity Severity 2 (Warning) Trap/EventID 6210 Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ iDRAC ✔ CMC ✔* WS Eventing ✔ CMC LC Log Remote System Log LCD ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RED006 Message Unable to download Update Package. Detailed Description The Update Package cannot be successfully downloaded. Recommended Response Action Check the network connection and access to the update package from the iDRAC.
Recommended Response Action Re-acquire the Update Package from the service provider. Category Updates (RED = FW Download) Severity Severity 2 (Warning) Trap/EventID 6210 Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ iDRAC ✔ CMC ✔* WS Eventing ✔ CMC LC Log Remote System Log LCD ✔ ✔ ✔ OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* RED008 Message Unable to extract payloads from Update Package.
RED009 Message Lifecycle Controller is not present. Detailed Description Lifecycle Controller is not present. Recommended Response Action Verify if Lifecycle Controller is installed on the system by pressing F10 on boot up. If the Lifecycle Controller application is not present, use the update package to reinstall it.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED0101 Message Rollback successfull. Detailed Description The firmware was rolled back to the previous version. Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) No alerts are applicable for this message RED011 Message USC version is not compatible. Detailed Description Current USC version does not support this component.
RED012 Message Unable to create Lifecycle Controller update task. Detailed Description Unable to create a Lifecycle Controller update task. The related job status is marked Failed. Recommended Response Action Retry the update operation after one minute.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED014 Message Job for this device is already present. Detailed Description A job for this update already exists in the queue and prevents the new job from being scheduled. Recommended Response Action Delete the existing job before scheduling a new update job. For Remote Services API consumers, enumerate all the jobs to find and identify the duplicate job.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED016 Message Mount of remote share failed. Detailed Description The remote share location that has the file(s) or ISO image did not mount correctly. Recommended Response Action 1. Verify that the path to the share is correct and that the parameters to the call are correct. 2.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED018 Message Reinstall or Rollback not supported for this device. Detailed Description Reinstall or Rollback not supported for this device. Recommended Response Action 1. Update the device directly using the update methods since rollback is not supported for this device. 2.
Category Updates (RED = FW Download) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED020 Message Feature not supported on current version of USC. Detailed Description The feature invoked is not supported by the current version of the Unified Server Configurator.
Recommended Response Action Ensure the component specified for updates is present in the system. Restart the system with Collect System Inventory on Restart enabled and verify that the component is represented by an instance of DCIM_SoftwareIdentity.
Detailed Description The Lifecycle Controller is unable to access internal storage currently in use by another operation. Recommended Response Action Make sure all other Lifecycle Controller operations are finished and retry the operation. Using the iDRAC Web UI, select Server and then Job Queue, check the job queue for unfinished jobs and wait for the jobs to finish before retrying the operation.
RED025 Message arg1 firmware updated successfully. Current version: arg2 Arguments arg1 = device name, arg2 = firmware version Detailed Description The firmware for the indicated device updated successfully to the identified firmware version. Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message Updated successfully.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED027 Message Insufficient space to upload the requested file. Detailed Description The temporary storage is full. The uploaded files must be installed to clear space for additional uploads. Recommended Response Action Select and install the currently uploaded files before uploading additional files.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED029 Message A reboot is pending. Detailed Description This task will reboot the system at the scheduled start time. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy RED031 Message Approaching maximum size limit allowed for storing firmware images. Detailed Description The internal space available for storing firmware images is almost full. Normal operations will continue until the critical limit is reached. When the critical limit is reached, all the rollback firmware images will be deleted. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED033 Message Unable to reboot system. Detailed Description The request to shut down the operating system did not complete successfully. The iDRAC was unable to complete the system reboot. Any operation that depends on the system reboot will not complete until reboot is complete.
Severity Severity 2 (Warning) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC ✔* CMC ✔* Reset Chassis Event Proxy RED035 Message arg1 Rollback successful. Earlier version: arg2 , Current version: arg3 .
Detailed Description Firmware updates are available for component identified in the message in the specified remote repository and it is recommended to update to the firmware available in the repository. Recommended Response Action Update the component firmware to the version available in the specified remote repository.
RED038 Message A recurring task of type arg1 is added. Arguments arg1 = task type Detailed Description An Automatic Server Profile Export or Automatic Update task identified in the message has been added. Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message A recurring task was added.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED040 Message A recurring operation of type arg1 created a job arg2 . Arguments arg1 = operation type, arg2 = job ID Detailed Description The job identified in the message was created by an Automatic Server Profile Backup, Automatic Update, or other recurring operation.
Recommended Response Action Install an iDRAC license that supports the following features: Automatic Update or Server Profile Export and Import. After the appropriate license has been installed, retry the operation. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message A recurring task was not created because the required license is not present.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED043 Message A recurring operation of type arg1 was not created because the operation type is disabled. Arguments arg1 = operation type Detailed Description The operation identified in the message is currently disabled. Recommended Response Action Enable the operation identified in the message and retry the operation.
Recommended Response Action Install an iDRAC license that supports the following features: Automatic Update or Server Profile Export and Import. After the appropriate license has been installed, retry the operation. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message A recurring task was unable to create a job because the required license is no longer present.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED046 Message A recurring operation of type arg1 was unable to create a job because the task type is now disabled. Arguments arg1 = operation type Detailed Description The operation identified in the message was disabled and the iDRAC was unable to create the next job in the sequence. Recommended Response Action Enable the operation identified in the message and retry the operation.
Recommended Response Action Clear the existing configuration settings for the operation identified in the message and retry the operation. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message A recurring task was not created because a task of that type is already present.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED049 Message The job arg1 is deleted because the recurring operation arg2 is currently not enabled. Arguments arg1 = job ID, arg2 = operation type Detailed Description When an Automatic Backup or Automatic Update recurring operation is disabled or the license for this feature is expired, the next job in the sequence had not started yet and was deleted. Recommended Response Action No response action is required.
Category Updates (RED = FW Download) Severity Severity 2 (Warning) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC ✔* Reset Chassis Event Proxy ✔ CMC RED051 Message The network file transfer of an update package was not successful. Detailed Description The update package file download was not successful.
Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED053 Message Processing of update packages has completed. Detailed Description Processing of update packages has completed.
Detailed Description A job for applying an update package was created. Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED055 Message A reboot job arg1 was created.
RED056 Message An internal error occurred. Unable to complete the specified operation. Detailed Description An internal error occurred because of insufficient memory available on iDRAC. Recommended Response Action Retry the operation. If the issue persists, reset the iDRAC and retry the operation.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED058 Message A repository update job arg1 was created. Arguments arg1 = job ID Detailed Description A repository update job with the job ID identified in the message was created. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC Reset Chassis Event Proxy ✔ CMC RED060 Message The specified repository catalog is not supported. Detailed Description The specified repository catalog is either not supported or the structure is incorrect. Only Windows Update Packages are supported by iDRAC and Lifecycle Controller for the operation.
Category Updates (RED = FW Download) Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED062 Message Unable to successfully authenticate user credentials to the specified repository. Detailed Description Unable to successfully authenticate.
Detailed Description The iDRAC firmware updated successfully to the firmware version identified in the message. Recommended Response Action No response action is required. Category Updates (RED = FW Download) Severity Severity 3 (Informational) LCD Message IDRAC Updated successfully.
RED065 Message The recurring scheduled update from repository job completed and updates were applied. A system restart was not required. Detailed Description The recurring scheduled update from repository job completed and updates were applied. A system restart was not required. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED067 Message The recurring scheduled update from repository job completed and updates were staged. The system will now restart to apply the staged updates. Detailed Description The recurring scheduled update from repository job completed and updates were staged. The system will now restart to apply the staged updates. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RED070 Message Unable to configure the Automatic Backup schedule. Detailed Description Unable to configure the Automatic Backup schedule due to invalid input parameters. Recommended Response Action Verify the input parameters to the set Automatic Backup schedule method are correct and retry the operation.
Recommended Response Action Configure the Automatic Backup schedule. Category Configuration (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED073 Message The input value entered for the parameter arg1 is invalid. Arguments arg1 = parameter Detailed Description The operation did not complete successfully because of an invalid value for the parameter identified in the message.
Recommended Response Action Check the Automatic Backup schedule to verify if it is accurate or delete the existing schedule and retry the operation. Category Configuration (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED076 Message Unable to create an Automatic Update schedule, because an invalid parameter is entered. Detailed Description Unable to create the Automatic Update schedule because an input parameter is invalid..
Recommended Response Action Configure the Automatic Update schedule. Category Updates (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED079 Message The input value entered for the parameter arg1 is invalid. Arguments arg1 = parameter Detailed Description The operation did not complete successfully because of an invalid value for the parameter identified in the message.
Recommended Response Action Delete the existing Automatic Update schedule operation before retrying the operation. Category Updates (RED = FW Download) Severity Severity 2 (Warning) No alerts are applicable for this message RED082 Message The requested job cannot be scheduled, because job schedule type such as Automatic Backup or Automatic Update is not enabled. Detailed Description The Automatic Update or Automatic Backup feature is disabled.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RED084 Message Unable to update the Chassis firmware because of an issue in the network communication between iDRAC and CMC. Detailed Description The Chassis firmware cannot be updated because of an issue in the communication between iDRAC and CMC. Recommended Response Action Verify the status of CMC by accessing the CMC and making sure it is functioning and responding and then retry the operation.
Recommended Response Action Make sure that the Chassis Management at Server attribute is set to Monitor and Configure, and then retry the operation. To set the correct attribute using Chassis Management Controller (CMC) GUI, navigate to Chassis Overview, then Setup, then General, and then click on the Chassis management at Server attribute to select the correct value.
Detailed Description A Chassis firmware update operation is in progress. Any attempt to update Chassis firmware during this period will be unsuccessful. Recommended Response Action No response action is required.
RED091 Message Unable to install Lifecycle Controller firmware. Detailed Description Unable to install Lifecycle Controller firmware. Recommended Response Action Reinstall the iDRAC7 firmware (DUP) to repair Lifecycle Controller. For more information, see Lifecycle Controller Users Guide. Category Updates (RED = FW Download) Severity Severity 1 (Critical) No alerts are applicable for this message RED092 Message The arg1 firmware updated successfully.
Detailed Description Lifecycle Controller is not enabled and must be enabled in order for scheduled jobs to be created. Recommended Response Action Enable Lifecycle Controller and retry the operation. Lifecycle Controller can be enabled by using the F2 System Setup by pressing F2 during server startup, then select iDRAC Settings > Lifecycle Controlller and enable the Lifecycle Controller feature. Retry the operation after the server restarts.
RED095 Message Update of rSPI was not successful after the Diagnostics package was updated. Detailed Description An item named rSPI that is dependent on the Diagnostics package was not updated successfully when the Diagnostics package was updated. Recommended Response Action No response action is required.
RFL Event Messages RFL2000 Message Internal Dual SD Module arg1 is present. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC RFL2003 Message Internal Dual SD Module arg1 is online. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Reinstall the SD module and remove and reinstall SD cards. Category System Health (RFL = IDSDM Media) Severity Severity 1 (Critical) Trap/EventID 2209 LCD Message Internal Dual SD Module failed.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RFL2006 Message Internal Dual SD Module arg1 is write protected. Arguments arg1 = name Detailed Description The module is write-protected. Changes may not be written to the media. Recommended Response Action if unintended, remove the media and disable write protection.
Trap/EventID iDRAC 2211 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC RFL2008 Message Internal Dual SD Module arg1 is disabled. Arguments arg1 = name Detailed Description The Internal Dual SD Card redundancy feature was disabled. The SD card identified in the message is disabled. Recommended Response Action No response action is required.
Recommended Response Action No response action is required.
RFLA Event Messages RFLA2001 Message Internal Dual SD Module arg1 is absent. Arguments arg1 = name Detailed Description The SD card module is not detected or not installed. Recommended Response Action If unintended, reinstall the SD module. Category System Health (RFLA = IDSDM Absent) Severity Severity 1 (Critical) Trap/EventID 2481 LCD Message Internal Dual SD Module is absent. Check SD card.
RFM Event Messages RFM1018 Message Removable Flash Media is absent. Detailed Description None Recommended Response Action No response action is required. Category System Health (RFM = FlexAddress SD) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1019 Message Removable Flash Media is present.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1020 Message Removable Flash Media is IPMI-function ready. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1022 Message Removable Flash Media is ready. Detailed Description None Recommended Response Action If unintended, reinstall the flash media.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RFM1024 Message Removable Flash Media is offline. Detailed Description At boot, the Card Identification (CID) signature of the card is different from the Non-volatile (NV) storage value or the card is the destination of a copy operation that is in-progress. Recommended Response Action If unintended, reinstall the flash media.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1026 Message Failure detected on Removable Flash Media. Detailed Description An error is reported during a SD card read or write. Recommended Response Action Re-install the flash media, if the issue persists replace the media.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1028 Message Removable Flash Media was activated. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1030 Message Removable Flash Media is booting. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1032 Message Removable Flash Media is write protected. Detailed Description The card is write-protected by the physical latch on the SD card. IDSDM cannot use a write-protected card. Recommended Response Action if unintended, remove the media and disable write protection.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC RFM1034 Message Media not present for Removable Flash Media. Detailed Description The SD card is not detected or not installed. Recommended Response Action If unintended, reinstall the flash media.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC 1575
RRDU Event Messages RRDU0001 Message Internal Dual SD Module is redundant. Detailed Description None Recommended Response Action No response action is required.
OMSA Event ID 5306 OMSA Trap ID 5306 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC RRDU0003 Message Internal Dual SD Module redundancy is degraded. Detailed Description Either one of the SD card or both the SD cards are not functioning properly. Recommended Response Action Replace the failed SD card.
Detailed Description None Recommended Response Action Install additional SD card and configure for redundancy if redundancy is desired.
RRDU0006 Message Internal Dual SD Module rebuild initiated. Detailed Description Internal Dual SD Module rebuild initiated. Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC RRDU0008 Message Internal Dual SD Module rebuild did not complete successfully. Detailed Description Internal Dual SD Module rebuild failed because read/write to one of the SD cards failed. Recommended Response Action Replace the failed SD card and retry rebuild.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC RRDU0011 Message Unable to determine the redundancy status of the Internal SD Module. Detailed Description This occurs because of one of the following reasons: 1) Either one of the SD card or both the SD cards have failed. 2) The Internal SD Module has failed.
RSI Event Messages RSI0001 Message The Lifecycle Controller Remote Services is available. Detailed Description The Lifecycle Controller Remote Services instrumentation is available. Recommended Response Action No response action is required.
RSI0004 Message The remote service is unavailable Detailed Description The Remote Service database is unavailable. Recommended Response Action Reset Integrated Remote Access Controller (iDRAC).
SEC Event Messages SEC0000 Message The chassis is open. Detailed Description The chassis is open. System performance may be degraded, and security may be compromised. Recommended Response Action Close the chassis. Check system logs. Category System Health (SEC = Security Event) Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Intrusion detected.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0002 Message The I/O card area is open. Detailed Description The I/O card area is open. I/O cards may be added or removed. System performance may be degraded. Recommended Response Action Close the I/O card area. Check system logs.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0004 Message The LAN is disconnected. Detailed Description The LAN is disconnected. Network performance may be degraded. Recommended Response Action If unintentional, connect network cable.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0006 Message The fan area is open. Detailed Description The fan area is open. System performance may be degraded. Recommended Response Action Close the fan area. Check system logs.
Trap/EventID 2387 OMSA Event ID 5252 OMSA Trap ID 5252 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEC0017 Message The drive bay is closed. Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (SEC = Security Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0019 Message The processor area is closed. Detailed Description None Recommended Response Action No response action is required.
Detailed Description None Recommended Response Action No response action is required. Category System Health (SEC = Security Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0021 Message The docking is authorized. Detailed Description None Recommended Response Action No response action is required.
SEC0022 Message The fan area is closed. Detailed Description None Recommended Response Action No response action is required. Category System Health (SEC = Security Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0031 Message The chassis is open while the power is on. Detailed Description The chassis is open.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* SEC0032 Message The chassis is closed while the power is on. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* SEC0034 Message The chassis is closed while the power is off. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2385 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SEC0041 Message BIOS is unable to configure the Intel Trusted Execution Technology (TXT). Detailed Description TXT initialization cannot be completed because system configuration may have changed.
Detailed Description TXT CPU microcode boot cannot be completed because system configuration may have changed. Recommended Response Action Check system hardware inventory for TPM presence, clear and reconfigure TPM and TXT in BIOS setup menu. Category System Health (SEC = Security Event) Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Problem with TXT operation. Reconfigure TPM and TXT in BIOS.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SEC0044 Message SINIT Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) problem at boot. Detailed Description TXT initialization cannot be completed because system configuration may have changed. Recommended Response Action Check system hardware inventory for TPM presence, clear and reconfigure TPM and TXT in BIOS setup menu.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SEC0051 Message Unable to determine the redundancy status of the chassis intrusion sensor. Detailed Description The chassis may be open. This condition can lead to degraded system performance because of insufficient cooling and the system security may be compromised.
Recommended Response Action Replace the chassis intrusion sensor. For more information, contact your service provider. Category System Health (SEC = Security Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SEC0100 Message The arg1 in slot arg2 is open.
SEC0101 Message The arg1 in slot arg2 is opened for more than 3 minutes. Arguments arg1 = module name, arg2 = slot number Detailed Description The Storage disk tray in the slot identified in the message has been open for an extended period of time. The tray should be closed as soon as any service action is completed. Leaving it open for extended period may result in drives overheating.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* SEC0600 Message A secure mode violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0602 Message User password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0604 Message A setup password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0606 Message The network boot password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0608 Message A password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0610 Message An Out-of-band password violation detected. Detailed Description This may apply to a remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEC0612 Message The default username and password is currently in use. It is recommended to immediately change the default credentials. Detailed Description The default username and password is currently in use and unauthorized access to the iDRAC may occur because the default values are widely known.
Recommended Response Action No response action is required. Category System Health (SEC = Security Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ ✔ OS Log Power Off Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD ✔* Power Cycle Reset Chassis Event Proxy ✔ CMC SEC0700 Message Warning: Default username and password are currently in use. It is strongly recommended to change the default password before configuring the propery.
SEC0701 Message Warning: Default username and password are currently in use. It is strongly recommended to change the default password immediately. Detailed Description This warning message is displayed when using the default username and password (root and calvin). Using the default password causes a severe security risk for iDRAC. Recommended Response Action To change the password, run the following racadm commands: racadm set iDRAC.Users..Password .
SEL Event Messages SEL0002 Message Logging is disabled. Detailed Description This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h) Recommended Response Action If unintended, re-enable logging.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* SEL0004 Message Log cleared. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL0007 Message All event logging is enabled. Detailed Description None Recommended Response Action No response action is required.
Category System Health (SEL = Sys Event Log) Severity Severity 1 (Critical) Trap/EventID 2377 LCD Message SEL is full. Review & clear log Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* SEL0010 Message System event log (SEL) is almost full.
Detailed Description if the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions. Recommended Response Action Reboot the management controller or iDRAC. Cycle system input power. If problem persists call support.
SEL0014 Message The System Event Log (SEL) was cleared by arg1 from arg2 . Arguments arg1 = username, arg2 = IP address Detailed Description The System Event Log (SEL) was cleared by the username identified in the message from the IP address identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1202 Message OEM system boot. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SEL1205 Message The unknown system hardware failure was corrected. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEL1207 Message An entry was removed from auxiliary log. Detailed Description None Recommended Response Action No response action is required.
Category System Health (SEL = Sys Event Log) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEL1209 Message The platform event filter action failed. Detailed Description System policies or permissions may prevent the action from executing.
Recommended Response Action No response action is required. Category System Health (SEL = Sys Event Log) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SEL1211 Message The time-stamp clock could not be synchronized. Detailed Description The time stamp on system event log events may not correlate to the system time.
Detailed Description System setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1eh - offset 00h) Recommended Response Action Check system boot settings. Check mass storage controller configuration settings is applicable.
SEL1302 Message Non-bootable diskette detected. Detailed Description The disk in the drive is not formatted correctly or does not contain the necessary operating system files(IPMI sensor type code 1eh - offset 01h) Recommended Response Action Replace diskette with bootable disk.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1304 Message The PXE server not found. Detailed Description PXE is one way to boot a system from the network. (IPMI sensor type code 1eh offset 02h) Recommended Response Action Check network and PXE server configuration.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1306 Message Invalid boot sector found. Detailed Description The disk in the drive is not formatted correctly or does not contain the necessary operating system files (IPMI sensor type code 1eh - offset 03h) Recommended Response Action Replace diskette with bootable disk.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1308 Message A time-out occurred while waiting for user to select a boot source. Detailed Description The system has failed to boot to an operating system and needs the user to select a boot source. (IPMI sensor type code 1eh - offset 04h) Recommended Response Action Select boot source within the time allowed.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1400 Message The platform generated a page alert. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1404 Message A platform event trap (PET) was generated. Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SEL1500 Message The chassis management controller (CMC) is redundant. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL1502 Message Chassis management controller (CMC) redundancy is degraded. Detailed Description An action or failure has taken place that degrades CMC redundancy. This includes firmware mismatch between CMCs and a CMC missing SD card.
Severity Severity 3 (Informational) Trap/EventID 2379 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL1504 Message The chassis management controller (CMC) is not redundant. Insufficient resources to maintain normal operations. Detailed Description There is not enough available power for two CMCs to operate.
Detailed Description The primary CMC has lost communication with the indicated member CMC. Recommended Response Action Check network cable and network connections.
SEL1508 Message Member arg1 could not join the Chassis Group. Arguments arg1 = number Detailed Description The indicated member may be a member of another chassis group or may be incompatible with membership. Recommended Response Action 1)Check that the Name or IP address, User Name, and Password of the member are correct. 2)Check that the member is not a leader or member of another group. 3)Check that the member can be reached by the leader.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL1510 Message An authentication error detected for Chassis Group Member arg1 . Arguments arg1 = number Detailed Description Group master CMC could not log into the group member CMC.
Recommended Response Action No response action is required. Category System Health (SEL = Sys Event Log) Severity Severity 3 (Informational) Trap/EventID 2379 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SEL9900 Message An unsupported event occurred.
SEL9901 Message OEM software event. Detailed Description The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC 1635
SSD Event Messages SSD1001 Message Write-cache on arg1 is enabled. Arguments arg1 = PCIe SSD name Detailed Description Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 90300 IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1003 Message arg1 is ready for removal. Arguments arg1 = PCIe SSD name Detailed Description The PCIe solid state drive (SSD) identified in the message is ready for removal. Recommended Response Action No response action is required.
Detailed Description The log file of the PCIe solid state drive (SSD) identified in the message is successfully exported. Recommended Response Action No response action is required.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1006 Message The arg1 has reached arg2 of warranted device wear-out limit. Arguments arg1 = PCIe solid state device name, arg2 = percent Detailed Description The PCIe solid state device identified in the message is approaching the warranted wear-out limit. Recommended Response Action No response action is required.
OMSA Event ID 2434 OMSA Trap ID 90300 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC SSD1008 Message The arg1 is approaching read-only mode. Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode.
Arguments arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is in read-only mode. Recommended Response Action Back up the data on the device, and contact your service provider for further instructions.
LC Log iDRAC CMC 1642 LCD OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy
STOR Event Messages STOR001 Message The command is successfully run. Detailed Description The command is successfully run. Recommended Response Action No response action is required. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR003 Message Missing parameter. Detailed Description Required parameter is missing. Recommended Response Action Refer to the RAID profile to determine required parameters.
STOR006 Message Unable to complete the operation. Detailed Description The operation could not be completed because of an issue with the management controller (either the iDRAC or the Chassis Management Controller (CMC)) that is managing the storage. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
STOR010 Message RAID level not supported on controller. Detailed Description The operation cannot be completed because the RAID level entered is not supported by the controller. Recommended Response Action Enter a valid RAID level and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR0101 Message No RAID controller is displayed. Detailed Description No RAID controller data to display.
STOR0103 Message No physical disks are displayed. Detailed Description No physical disk data to display. The system is powered off, physical disks are not present on the system, or physical disks are not connected to the enclosure or backplane Recommended Response Action Check if the server has power, physical disks are available, and physical disks are connected to the enclosure or backplane.
STOR0106 Message Fans are not connected to enclosures or data about fans is unavailable. Detailed Description No fan data to display. The system is powered off, no fan enclosures are present in the system, or the fans are not connected to the enclosures. Recommended Response Action Check if the server has power, enclosure fan is available, and fan is connected to the enclosure.
STOR0109 Message Power supply unit is not connected to the enclosure or data about power supply unit is unavailable. Detailed Description No power supply unit data to display. The system is powered off, no power supply unit is present in the system, or the power supply unit is not connected to the enclosure. Recommended Response Action Check if the server has power, enclosure power supply unit is available, and power supply unit is connected to the enclosure.
STOR0111 Message Invalid reference key. Detailed Description The specified reference key is invalid. Recommended Response Action Verify that the correct reference key is specified. See the help text or documentation for valid reference keys. Category Storage (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR012 Message Provided Physical disk not valid for this operation.
STOR015 Message Maximum virtual disks allowed for this controller has been reached. Detailed Description A new virtual disk cannot be created because the maximum number of virtual disks are already created. Recommended Response Action A new virtual disk cannot be created until one is deleted.
STOR018 Message No foreign drives detected. Detailed Description This operation did not detect any foreign drives. This may be because no foreign drives are present or the only foreign drives are in a secured state. Recommended Response Action If the only foreign drives present are in a secured state, run a secure erase operation on the drives and retry the operation. Otherwise the operation was not successful because there are no foreign drives.
STOR0200 Message Array Manager is installed on the system. Detailed Description Installing Storage Services and Array Manager on the same system is not a supported configuration. Storage Services is not installed on a system where Array Manager is installed. Recommended Response Action Uninstall either Storage Services or Array Manager and retry the operation.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0202 Message The configuration file (Path: arg1 ) that contains firmware and driver information for arg2 is not updated or is incorrectly formatted to complete the comparison.
Detailed Description The version of the operating system kernel and the driver do not meet the minimum requirements. Storage Services may not be able to display or perform storage management functions until the system meets the minimum requirements. Recommended Response Action See the Readme file on the installation media for operating system kernel and driver version requirements. Update the system to meet the minimum requirements and then reinstall Storage Services.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0205 Message Global rescan initiated for all storage components in the system. Detailed Description A rescan of all storage components in the system is initiated. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0207 Message Smart thermal shutdown feature is disabled. Detailed Description The storage shutdown feature based on high ambient temperature (smart themal shutdown) is disabled. Recommended Response Action No response action is required.
Category Storage (STOR = Storage) Severity Severity 3 (Informational) OMSA Event ID 2287 OMSA Trap ID 10100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR0209 Message Unable to monitor or manage SAS components because the initialization sequence of the devices did not complete.
STOR021 Message The controller key is not present. Detailed Description The virtual disk cannot be secured because a controller key is not present. Recommended Response Action Set an appropriate controller key and retry the operation. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR0210 Message SCSI sense data ( arg1 ) received from arg2 .
Arguments arg1 = device name Detailed Description The device identified in the message that was previously in an error state has returned to a normal state. For example, if an enclosure became too hot and subsequently cooled down, or if a degraded virtual disk returns to normal state. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC STOR022 Message The controller is not security capable. Detailed Description The specified controller does not have the capability to secure virtual disks. Recommended Response Action No response action is required.
Detailed Description Configuration changes for the specified device are already scheduled. Recommended Response Action No response action is required. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR025 Message Unable to delete any pending configuration because the configuration job is already scheduled. Detailed Description The pending configuration cannot be deleted because the configuration job is already scheduled.
Detailed Description Setting the Virtual disk name is not a valid operation on the specified controller. Recommended Response Action Do not specify the virtual disk name and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR028 Message Virtual disk not found. Detailed Description The requested operation cannot be completed because the specified virtual disk is not found.
Recommended Response Action Provide a valid controller FQDD (Fully Qualified Device Descriptor) and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR031 Message Lifecycle Controller is not enabled. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation.
STOR033 Message Invalid parameter value for Start/Until Time. Detailed Description The requested operation cannot be completed because an invalid value is specified for Start/Until Time. Recommended Response Action Enter a valid Start/Until Time and retry the operation. For more information about the Start/Until Time, see the RAID Profile specification.
STOR037 Message Missing required parameter arg1 . Arguments arg1 = parameter name Detailed Description Unable to complete the requested operation because one or more input parameters identified in the message are not specified. Recommended Response Action Enter all the required parameters and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR038 Message Invalid parameter value for arg1 .
STOR040 Message Invalid AttributeName arg1 . Arguments arg1 = attribute name Detailed Description Unable to complete the requested operation because an invalid AttributeName value is specified. Recommended Response Action Specify a valid AttributeName value for the attribute identified in the message and retry the operation.
No alerts are applicable for this message STOR043 Message One or more selected physical disk drives are part of virtual disk that is not Secondary RAID Level 0. Detailed Description One or more physical disk drives selected for the operation are part of a virtual disk that is not Secondary RAID Level 0. Recommended Response Action This operation is not supported unless the previous virtual disk on the selected physical disk drives are deleted first.
STOR046 Message The specified StartingLBA and Size values combination result in an overlapping virtual disk. Detailed Description Unable to complete the create virtual disk operation because the StartingLBA and Size value combination results in an overlapping virtual disk. Recommended Response Action Refer to the users guide to provide the correct StartingLBA and Size combination values.
STOR049 Message Controller is in Local Key Management mode. Detailed Description The controller is in Local Key Management mode. Recommended Response Action No response action is required. Category Configuration (STOR = Storage) Severity Severity 3 (Informational) No alerts are applicable for this message STOR050 Message Controller is in Dell Key Management mode. Detailed Description The controller is in Local Key Management mode. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC STOR0502 Message Unable to launch RAID Configuration wizard. Detailed Description No RAID controller is installed on the system. Recommended Response Action Install the RAID controller and do the following: 1) Reboot the system. 2) Press the key to re-enter Lifecycle Controller. 3) Retry RAID configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC STOR0504 Message Successfully completed RAID operation. Detailed Description The RAID operation was successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC STOR0506 Message Unable to create virtual disk. Detailed Description The physical disk is unreadable or the RAID controller is not responding. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC STOR0508 Message No supported controllers present for RAID configuration. Detailed Description Unable to configure RAID as the supported RAID controller is not present.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC STOR051 Message StartingLBA and Size value combination is greater than allowed by the physical disk size. Detailed Description The requested operation cannot be completed because the specified StartingLBA and Size value combination is greater than allowed by the physical disk size.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR0511 Message Unable to change the encryption key. Detailed Description Unable to change the encryption key due to an internal error. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR0513 Message Unable to encrypt virtual disks. Detailed Description Unable to encrypt unsecure virtual disks due to an internal error. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation. If the problem persists, update the RAID controller firmware to the latest version and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC STOR052 Message Unable to create virtual disk, maximum number of created virtual disks per controller or diskgroup has been reached. Detailed Description Virtual disks cannot be created because the maximum number of logical drives per controller or diskgroup is reached.
Severity Severity 3 (Informational) No alerts are applicable for this message STOR055 Message BIOS does not support Dell Key Manager capabilities. Detailed Description The BIOS on the server is not Dell Key Management capable. Recommended Response Action For more information about key management capabilities, see Dell Key Manager or Lifecycle Controller Remote Services Guide availalbe at dell.com/support/manuals.
Severity Severity 3 (Informational) No alerts are applicable for this message STOR058 Message This operation is not supported on this device. Detailed Description The operation is not supported on the target device. Recommended Response Action For more information, see Lifecycle Controller-Remote Services documentation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR061 Message Initializing virtual disk is not supported on the RAID controller. Detailed Description The initializing virtual disk operation is not supported on the target device.
Severity Severity 3 (Informational) No alerts are applicable for this message STOR063 Message Unable to assign the specified virtual disk to multiple Virtual Adapters in single assignment mode. Detailed Description In order to prevent data loss, the system has prevented the assignment of a Virtual Disk to multiple Virtual Adapters because the clustered assignment mode is not enabled.
Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR066 Message Controller is not T10 Protection Information capable. Detailed Description The requested operation did not succeed because the selected RAID controller is not T10 Protection Information capable. Recommended Response Action Verify that the RAID controller selected for the operation is T10 Protection Information capable, and then retry the operation.
No alerts are applicable for this message STOR069 Message Unable to run the arg1 method, because the number of elements entered for VDPropNameArry and VDPropValueArray is unequal. Arguments arg1 = method name Detailed Description The method name identified in the message could not be successfully completed, because the number of elements entered for VDPropNameArry and VDPropValueArray is not equal. Recommended Response Action Enter equal number of elements (pair value), and then retry the operation.
Recommended Response Action Storage objects are unavailable in the current system configuration. Make sure that the storage devices are installed in the system, and then retry the operation after the Collect System Inventory On Restart (CSIOR) feature has updated the system inventory. If the issue persists, contact your service provider.
Severity Severity 2 (Warning) No alerts are applicable for this message STOR072 Message iDRAC Service Module (ISM) is either not present or not running on the server OS. Detailed Description The configuration operation could not be performed because it requires iDRAC Service Module (ISM) service to be present and running in the server Operating System. Recommended Response Action Make sure the iDRAC Servive Module (ISM) service is running on the server Operating System and then retry the operation.
Severity Severity 2 (Warning) No alerts are applicable for this message STOR075 Message The operation cannot be performed because the enclosure configuration mode (Split or Unified) change request is pending. Detailed Description The requested operation could not be completed because there is an operation pending to change the enclosure configuration mode (Split or Unified). This operation is exclusive because it involves changing the RAID backplane topology.
Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR078 Message The requested operation requires a reboot type that does not match the reboot type required for pending operations. Detailed Description The requested operation cannot be performed because it involves server reboot type which is different than the reboot type of pending operations.
Recommended Response Action Change the reboot type for job creation and retry the operation. Category Configuration (STOR = Storage) Severity Severity 2 (Warning) No alerts are applicable for this message STOR082 Message The operation cannot be stopped or cancelled because the operation is not currently running. Detailed Description The operation cannot be stopped or canceled because the operation is not currently running.
configuration and job creation on the next controller. 2) Schedule multiple jobs to run at a later time using the scheduling options. Recommended Response Action Make sure that the currently running job is completed, and then retry the operation. If necessary, recreate the configuration and the job. For information about running jobs on multiple storage controllers, see the iDRAC Online Help or iDRAC Users Guide.
Category Storage (STOR = Storage) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR092 Message Unable to run the configuration operation on the controller because foreign configuration import operation is in progress.
Recommended Response Action Make sure an operation is not pending on the controller. If an operation is pending, wait for the operation to complete or cancel the pending operation and then rety the operation. Refer to the storage controller documentation for compatibility information.
STOR095 Message Storage operation is successfully completed. Detailed Description Storage operation is successfully completed. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR097 Message Unable to complete the operation because the memory size of the physical disk drive is less than the available or entered virtual disk size. Detailed Description A virtual disk cannot be created because the memory size of the physical disk drive is less than available or entered virtual disk size.
Severity Severity 2 (Warning) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR1 Message A device arg1 is in an unknown state. Arguments arg1 = device name Detailed Description The controller cannot communicate with a device. The state of the device cannot be determined.
STOR10 Message Access to shared storage will not be available, because the RAID controller is unable to turn on. Detailed Description The RAID controller was detected, however it is unable to turn on. Access to shared storage will not be available. Recommended Response Action Update the Chassis Infrastructure firmware.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔* CMC ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* STOR12 Message Chassis is operating with a disabled RAID controller. Detailed Description One or more RAID controllers is disabled. This prevents Fault Tolerant mode from operating. Recommended Response Action No response action is required.
Recommended Response Action Make sure that the newly inserted storage sled has the same number of PERC controllers as the pervious storage sled so that the new sled will have the same operation mode after part replacement.
STOR15 Message The storage sled arg1 is improperly configured. Arguments arg1 = slot number Detailed Description The storage sled identified in the message was inserted in a location which does not support split dual host operation mode. The storage sled can functionally work in the current location with only primary PERC controller enabled. Recommended Response Action Do one of the following: 1) Change the operating mode of the storage sled indentified in the message.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔* iDRAC ✔ ✔* ✔* ✔* CMC ✔ ✔* ✔* ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔* ✔* ✔* STOR17 Message The fault-tolerant pair of RAID controllers arg1 and arg2 can have issues in their PCIe fabric because both controllers are on the same PCIe fabric.
Recommended Response Action Remove the shared storage device from the unsupported slot and place it in slot 5 or 6. Category Storage (STOR = Storage) Severity Severity 2 (Warning) Trap/EventID 4178 Filter Visibility iDRAC ✔ CMC ✔ IPMI Alert LC Log LCD ✔ ✔* SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ ✔* OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC STOR2 Message SCSI sense data arg1 .
STOR3 Message CEM Storage Management has lost communication with the arg1 . Arguments arg1 = Controller Name Detailed Description Storage Management has lost communication with a controller. This may occur if the connectivity between the controller and iDRAC is disrupted or any underlying hardware problems are encountered. Recommended Response Action Reboot the system or iDRAC. If the problem is not resolved, contact technical support.
STOR301 Message Unable to perform the operation because the controller mode change request is pending. Detailed Description The requested operation could not be completed because there is an operation pending to change the controller mode. This operation is exclusive because it requires a server reboot for changes to apply..
No alerts are applicable for this message STOR304 Message Unable to change controller mode while Virtual Disks and/or Hotspares are present on the controller. Detailed Description Controller mode cannot be changed as the controller has virtual disk or hotspare associated with it. Recommended Response Action Delete the Virtual Disks and/or Hotspares and retry the operation.
STOR307 Message Unable to perform the configuration operation because the export log operation is currently in progress. Detailed Description Unable to perform the configuration operation because the export log operation is currently in progress. Recommended Response Action Wait until the current export operation is complete, and then try the configuration operation again.
STOR310 Message Unable to initialize the virtual disk because the RAID controller selected does not support the initialization mode. Detailed Description The virtual disk cannot be initialized because the RAID controller selected does not support the initialization mode. Recommended Response Action Make sure that the RAID controller selected for the operation supports the initialization mode, and they retry the operation.
Arguments arg1 = VD/Enclosure Name Detailed Description A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more physical disks included in the virtual disk have failed. Due to the failed physical disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an additional physical disk will result in lost data. In the case of an enclosure, more than one enclosure component has failed.
Severity Severity 3 (Informational) Trap/EventID 4179 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* STOR7 Message The storage management instrumentation is performing an inventory refresh operation. Detailed Description The storage monitoring instrumentation detected a burst of events from underlying storage controllers.
Detailed Description High Availability RAID is not supported by this firmware release. This event may occur during the upgrade process. Recommended Response Action Remove one RAID controller.
SUP Event Messages SUP001 Message Insufficient parameters provided. Detailed Description Insufficient Parameters provided for the WSMAN command. Recommended Response Action Make sure the parameters are correct and in the right number and format and retry the action. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP002 Message Job creation failure.
SUP005 Message Invalid reboot value. Detailed Description Reboot value specified is not supported. Recommended Response Action Verify the reboot value and retry the action. Current options available are 1)Power Cycle 2) Graceful shutdown without forced shutdown 3) Graceful shutdown with forced shutdown (~10 minutes wait time). Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP006 Message Update package downloading - Delete failed.
SUP009 Message Driver pack update in progress - Delete failed. Detailed Description Because of the size of the driver pack, the update process removes the older version of the driver pack from the system before installing the newer version. For that reason, the driver pack update cannot be deleted. Recommended Response Action Wait for the Driver Pack update to complete. To revert to the previous version of the update, download and update the firmware to the version desired.
SUP0102 Message Invalid TFTP IP address specified. Detailed Description The TFTP IP Address specified is invalid. Recommended Response Action Specify a valid TFTP IP Address. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP0103 Message TFTP IP address is not reachable. Detailed Description The specified TFTP server is not reachable. Recommended Response Action Check if the TFTP server is alive.
SUP0105 Message Invalid firmware image Detailed Description The firmware image provided by the user is not valid. Recommended Response Action Provide a valid firmware image. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP0106 Message Unable to locate firmware image file in specified path. Detailed Description There is no firmware image present at the specified path.
SUP0108 Message A firmware update operation is already in progress. Detailed Description The firmware update is in progress and another update cannot be done. Recommended Response Action Wait for the update operation to conclude and then re-try. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP0109 Message A TFTP IP address has not been specified but is required.
SUP0110 Message Uninitializing firmware update services. Please wait... Detailed Description The firmware update is being uninitialized. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0111 Message Timeout waiting for firmware update process to complete. Detailed Description Firmware Update time-out occurred.
SUP0113 Message TFTP firmware update is currently disabled. Detailed Description The cfgRhostsFwUpdateTftpEnable object must be set. Recommended Response Action Set the cfgRhostsFwUpdateTftpEnable object in cfgRemoteHosts group using config subcommand. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP0114 Message The firmware update operation could not be completed successfully.
SUP0116 Message The RAC configuration has initiated restoration to factory defaults. \nPlease wait up to a minute for this process to complete before accessing \nthe RAC again. Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0117 Message Firmware rollback initiated successfully. \nThe iDRAC will now reset to complete the firmware
SUP0119 Message Firmware rollback failed Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 1 (Critical) No alerts are applicable for this message SUP0120 Message Preparing for firmware update. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
SUP0122 Message Firmware update completed successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0123 Message Firmware update completed successfully. The RAC is in the process of\nresetting. Your connection will be lost. Please wait up to a minute before starting a new session. Detailed Description Success message.
SUP0125 Message Current firmware update status is unknown Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0126 Message Firmware update in progress. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
SUP0128 Message Ready for firmware update Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0129 Message Resetting the RAC. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
SUP0130 Message TFTP firmware update has been initiated. This update process may take several minutes to complete. Detailed Description Success message. Recommended Response Action No response action is required. Category Updates (SUP = FW Update Job) Severity Severity 3 (Informational) No alerts are applicable for this message SUP0131 Message FTP firmware update has been initiated. This update process may take several minutes to complete. Detailed Description Success message.
SUP015 Message Input parameters values should not be NULL. Detailed Description One of the parameters specified received a NULL value that prevented the action from completing. Recommended Response Action Correct the parameter value and retry the command. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP016 Message Job cannot be scheduled.
SUP018 Message Invalid until time. Detailed Description The specified until time is invalid. Recommended Response Action Until Time should be in the form YYYYMMDDHHMMSS. Verify the specified until time and retry the action. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP019 Message Lifecycle Controller is not enabled. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation.
Severity Severity 3 (Informational) No alerts are applicable for this message SUP021 Message Diagnostics, Driver Pack or Lifecycle Controller update is a direct update and cannot be scheduled. Detailed Description Diagnostics and USC updates are direct updates and cannot be scheduled Recommended Response Action Do not schedule USC or Diagnostics Jobs.
SUP024 Message InstanceID value provided for the update operation is invalid Detailed Description The InstanceID value provided for update operation is invalid.
SUP027 Message Missing required parameter arg1 Arguments arg1 = parameter Detailed Description The required parameter identified in the message is missing. Recommended Response Action Verify the required parameter value for the method is specified and retry the operation. Category Updates (SUP = FW Update Job) Severity Severity 2 (Warning) No alerts are applicable for this message SUP028 Message The GetRepoBasedUpdateList method did not complete successfully.
SUP030 Message Proxy IP and User Credential pare valid only if the ProxySupport parameter is TRUE. Detailed Description The value of the ProxySupport parameter must be TRUE if the Proxy IP and User Credentials need to be provided for the operation requested. Recommended Response Action Do not specify Proxy IP and User Credential parameters if the ProxySupport parameter is FALSE.
Recommended Response Action Retry the operation. If the problem persists do the following: 1) Turn off the system and disconnect the power cord. 2.) Wait for five seconds. 3.) Reconnect the power cord and turn on the system. 4) Press the key to re-enter Lifecycle Controller, and retry the operation. If the problem continues to persist, update iDRAC firmware to the latest version, and retry the operation. Else, contact the service provider.
SUP0504 Message Unable to authenticate the catalog file in the update repository. Detailed Description The catalog file in the update repository is not digitally signed. Recommended Response Action Use a repository that has the catalog file from a trusted source and retry the operation. If the catalog is from a trusted source, click OK to proceed without digital signature verification.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0506 Message Unable to decompress the catalog file. Detailed Description The catalog file in the selected repository is corrupt or compressed in an unsupported format. Recommended Response Action Select a repository with a valid catalog file, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0511 Message Unable to find Diagnostics application. Detailed Description The Diagnostic application (Embedded Preboot System Assessment - Enterprise UEFI Diagnostics) is not installed or is corrupt. Recommended Response Action Update the Diagnostics application using the Firmware Update feature in Lifecycle Controller. For the latest Update Packages, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0514 Message Unable to perform firmware rollback. Detailed Description An internal error occurred while performing firmware rollback operation. Recommended Response Action Exit the Firmware Rollback wizard and retry the operation. If the problem persists, reboot the system and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0516 Message Updating firmware for arg1 to version arg2 . Arguments arg1 = component, arg2 = version Detailed Description Do not turn off the system while firmware update is in progress. Recommended Response Action No response action required.
Category Updates (SUP = FW Update Job) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0518 Message Successfully updated the arg1 firmware to version arg2 . Arguments arg1 = component, arg2 = version Detailed Description The specified firmware for the component was successfully updated.
Recommended Response Action Retry the operation. If the problem persists, download the latest Update Package from your service provider and retry the operation. Category Updates (SUP = FW Update Job) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0520 Message Unable to update the arg1 firmware to version arg2 .
Detailed Description Write protection is enabled for the BIOS image and local BIOS update is disabled. Recommended Response Action To flash the BIOS locally, enable local BIOS update by selecting System Setup.
SUP0526 Message Unable to continue with firmware update. Detailed Description Unable to continue the firmware update because the catalog file or the update package is corrupt. Recommended Response Action Retry the operation. If the issue persists, download the latest Update Package or Catalog file from your service provider and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0528 Message Unable to generate a firmware comparison table. Detailed Description An internal error occurred in the Lifecycle Controller while generating the firmware comparison report. Recommended Response Action Exit the Platform Update wizard and retry the operation. If the problem persists, update the Lifecycle Controller firmware to the latest version and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0530 Message Incorrect repository path location. Detailed Description The catalog repository path entered is not accessible. Recommended Response Action Retry the operation with the correct catalog repository path.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0532 Message The repository contains corrupt Update Packages. Detailed Description The repository contains corrupt Update Packages. Recommended Response Action Enter another repository location that contains the desired Update Packages and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SUP0534 Message Unable to locate the catalog file. Detailed Description The catalog file cannot be found in the specified location. Recommended Response Action Specify the correct repository location and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0536 Message Successfully updated arg1 . Arguments arg1 = component and version Detailed Description Component firmware update was successful. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0538 Message Unable to update arg1 . Arguments arg1 = component and version Detailed Description Unable to update firmware due to one the following: 1) Update Package is not supported. 2) Trusted Platform Module feature is enabled in BIOS settings.
Recommended Response Action Enter another repository location that contains the desired Update Packages and retry the operation. Category Updates (SUP = FW Update Job) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP0540 Message Unable to install update packages because of insufficient space in the iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP1902 Message Firmware update stopping services. Detailed Description Firmware update stopping services. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP1904 Message Firmware update checksumming image. Detailed Description Firmware update checksumming image. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP1906 Message Firmware update successful. Detailed Description Firmware update successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP1908 Message Firmware update failed checksum. Detailed Description Firmware update failed checksum. Recommended Response Action Reacquire the image from the original source and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP1910 Message Firmware update is not pending. Detailed Description Firmware update is not pending. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SUP1912 Message Firmware update RAC recover successful. Detailed Description Firmware update RAC recover successful. Recommended Response Action No response action is required.
SWC Event Messages SW0725 Message iDRAC7 communication failure. Detailed Description iDRAC7 is busy and does not respond to iDRAC7 configuratorIPMI requests. Recommended Response Action Try AC power cycling the server or upgrade the iDRAC firmware. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0001 Message Unable to save the network settings.
Detailed Description The Part Replacement policy configuration operation encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
SWC0004 Message Unable to add a work note to the Lifecycle Log. Detailed Description The operation to add a work note to the Lifecycle Log encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0006 Message Unable to display the As Shipped hardware inventory. Detailed Description The view As Shipped hardware inventory operation encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0008 Message Unable to write the As Shipped hardware inventory to the specified destination. Detailed Description The export As Shipped hardware inventory operation did not complete because the destination: 1) does not have the specified folder, 2) does not have enough free space, or 3) is read-only.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0012 Message Unable to retrieve the front panel security settings. Detailed Description The operation to retrieve the front panel security settings encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation.
Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0014 Message Unable to set new date and time. Detailed Description Unable to apply the changes to the date and time settings because an internal error occurred.
Recommended Response Action Update the system with the latest Lifecycle Controller OS Driver Pack. Obtain the OS Driver Pack from the service provider. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0016 Message Unable to initialize OS Deployment wizard.
Detailed Description An unrecoverable error occurred while retireving the drivers. Recommended Response Action Exit the OS Deployment wizard and retry the operation. If the problem persists, exit Lifecycle Controller and perform an AC power cycle.
SWC0019 Message The Test Network Connection operation completed with errors. Detailed Description The Test Network Connection ping test timed-out. The network cable is disconnected or the network is not configured correctly. Recommended Response Action Check the network cable connection and network configuration settings, then retry the operation. If the problem persists, reconfigure the network settings and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0024 Message The Test Network Connection ping test timed-out. Detailed Description The Test Network Connection ping test timed-out. The network cable is disconnected or the network is not configured correctly. Recommended Response Action Check the network cable connection and network configuration settings, then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0026 Message Unable to retrieve status of backup Server Profile operation. Detailed Description Status of backup Server Profile operation could not be retrieved because an unrecoverable error occurred while communicating with iDRAC. Recommended Response Action Reset iDRAC and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0028 Message The backup Server Profile operation did not successfully complete. Detailed Description iDRAC is unable to complete the backup Server Profile operation because an unrecoverable error occurred. Recommended Response Action Reset iDRAC and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0030 Message Unable to complete the backup Server Profile backup operation. Detailed Description iDRAC is unable to complete the backup Server Profile operation. Recommended Response Action Reset iDRAC and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0032 Message Successfully exported the Server Configuration Profile image file to the USB drive. Detailed Description Exporting the Server Configruation Profile image file to the USB drive was successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0034 Message Unable to export the file to the network share. Detailed Description Lifecycle Controller is unable to export the file to the network share because it has insufficient free space. Recommended Response Action Make sure that the network share has sufficient free space then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0036 Message Unable to launch hardware diagnostics. Detailed Description Unable to launch hardware diagnostics because the Enterprise UEFI Diagnostics application is corrupt or iDRAC is not responding. Recommended Response Action Retry the operation.
Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0038 Message Unable to export the file to the network share. Detailed Description Lifecycle Controller is unable to export the file to the network share because the destination folder is read-only or inaccessible.
Recommended Response Action A backup Server Configuration Profile is required to import or export a Server Profile. Perform the backup operation and retry import or export operation. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0040 Message Unable to complete the Import operation.
Detailed Description The specified source file location is incorrect. Recommended Response Action Make sure that the specified source file location is correct and retry the operation.
SWC0043 Message Import Server Profile operation completed with errors. Detailed Description The Import Server Profile operation has completed with errors. For more information, see the Lifecycle Log. Recommended Response Action Exit the Import Server Profile wizard and retry the operation. If the problem persists, do the following: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0045 Message Unable to complete the Import operation. Detailed Description The Import operation did not successfully complete. For more information, see the Lifecycle Log. Recommended Response Action Exit the Import Server Profile wizard and retry the operation. If the problem persists, do the following: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0047 Message Incorrect backup Server Configuration Profile file passphrase provided. Detailed Description The passphrase specified is not correct. Recommended Response Action Enter the valid passphrase and retry the operation.
Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0049 Message Unable to continue the Import operation. Detailed Description The Import operation cannot continue because backup image file is not present on the vFlash SD card, the image is invalid, or the entered passphrase is incorrect.
Recommended Response Action Retry the Import operation using a valid backup image file and the correct passphrase. If the problem persists, do the following: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
Detailed Description An error occurred while retrieving the operating system drivers. Recommended Response Action Exit the OS Deployment wizard and update the system with the latest operating system driver packs available from the service provider and retry the operation. For more information, see the Lifecycle Controller users guide.
SWC0054 Message Unable to save settings. Detailed Description There was an internal error while saving the settings. Recommended Response Action Retry the operation. If the problem persists, reboot the system or update the Lifecycle Controller firmware to the latest version and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0056 Message Unable to export the file to the USB drive. Detailed Description Unable to export the file to the USB drive because it does not have the specified folder, does not have enough free space, or is read-only. Recommended Response Action Make sure that the USB drive contains the folder specified, has enough free space, or is not read-only.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0058 Message Unable to complete the operation. Detailed Description An internal processing error occurred. Recommended Response Action Reboot the system and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0060 Message Unable to complete the operation. Detailed Description One or more vFlash partitions are attached. Recommended Response Action Use iDRAC Web interface to detach the vFlash partitions and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0062 Message Unable to export Lifecycle Log. Detailed Description The destination folder is not present, the destination is full or write-protected. Recommended Response Action Verify the following and retry the operation: 1) Destination folder is present. 2) Destination has enough free space.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0064 Message Unable to mount the network share. Detailed Description The details provided to access the network share are incorrect. Recommended Response Action Enter the correct network share details, and retry the operation.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0066 Message Unable to connect to the Network Share. Detailed Description Unable to connect to the Network Share due to one of the following: 1) Login credentials entered are incorrect. 2) Network is inaccessible. 3) System IP address conflicts with another system on the network.
Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0068 Message Unable to retrieve the boot mode settings from BIOS. Detailed Description The BIOS boot mode settings could not be retrieved because of an internal issue.
Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0070 Message The Tech Support Report is successfully exported to the USB drive. Detailed Description The Tech Support Report is successfully exported to the USB drive.
Detailed Description The Tech Support Report is successfully exported to the network share folder. Recommended Response Action No response action is required.
SWC0073 Message Unable to start operation with the current iDRAC version. Detailed Description The Repurpose or Retire system operation cannot be successfully started because the current version of iDRAC firmware does not support the operation. Recommended Response Action Update iDRAC firmware to the latest version and retry the operation. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC0075 Message Unable to perform RAID operations because the selected controller is in HBA mode. Detailed Description Unable to perform RAID operations because the selected controller is in HBA mode. Recommended Response Action Do one of the following: 1) Retry the operation using other controllers that support RAID operations and are not in HBA mode.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC0077 Message Unable to initiate the Repurpose or Retire System operation. Detailed Description iDRAC is unable to initiate the Repurpose or Retire System operation because the iDRAC is not responding or another operation is in progress. Recommended Response Action Retry the operation.
No alerts are applicable for this message SWC0102 Message The -m option is not supported by the interface being used. Detailed Description The option requested is not available on the interface being used. Recommended Response Action Refer to the help to get the list of options valid for the interface. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0103 Message The -E option is not valid for the specified log.
SWC0105 Message Invalid -m option. Try --more or refer help for proper usage Detailed Description The command does not take in the -m option. Recommended Response Action Refer the help text for getraclog command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0106 Message The -u option is not supported on the current RAC configuration. Detailed Description The specified option is not supported on the RAC.
SWC0108 Message The service tag is not currently populated. Detailed Description The Service Tag string is empty. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0109 Message No process information is currently available. Detailed Description There is no RAC diagnostic information available. Recommended Response Action No response action is required.
SWC0111 Message A server action command must be specified. Detailed Description The serveraction subcommand requires an option to be specified. Recommended Response Action Refer the help for serveraction subcommand, and enter a valid option. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0112 Message Timeout while waiting for server to perform requested power action.
SWC0114 Message The -o option cannot be used with any other options. Detailed Description The syntax of the setniccfg command is invalid. Recommended Response Action Refer the help text for setniccfg subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0115 Message The -s option cannot be used with any other options. Detailed Description The syntax of the setniccfg command is invalid.
SWC0117 Message Invalid syntax. Both -f and -t must be specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Refer the help text for sslcertdownload subcommand. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0118 Message Invalid syntax. -f must be specified. Detailed Description The syntax of the sslcertupload command is invalid.
SWC0120 Message Invalid syntax. Certificate type (-t) must be specified. Detailed Description The syntax of the sslcertview command is invalid. Recommended Response Action Refer the help text for sslcertview subcommand. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0121 Message Invalid syntax. User index (-i) must be specified. Detailed Description The syntax of the sslcertview command is invalid.
SWC0123 Message The -s option is not valid with any other options. Detailed Description The syntax of the sslcsrgen command is invalid. Recommended Response Action Refer the help text for sslcsrgen subcommand. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0124 Message The -u option requires -f to be specified. Detailed Description The syntax of the sslcsrgen command is invalid.
SWC0126 Message Unable to download CSR file. Detailed Description Racadm tool was unable to download the generated CSR file. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0127 Message Unable to open file for writing. Detailed Description The file may be write protected and hence could not be edited.
SWC0129 Message Unable to send test email. Please make sure that your email alerts\nhave been configured correctly and connectivity to \nthe SMTP server exists. Detailed Description Racadm tool was not able to send a test email for the configuration. Recommended Response Action Check for the parameters mentioned in the message.
SWC0132 Message Unable to send test trap. Please make sure that your trap\nhas been configured correctly and connectivity to \nthe destination endpoint exists. Detailed Description Either the destination Ip address is not reachable or the required values are not configured. Recommended Response Action Check for the connectivity to the configured Ip address.
SWC0135 Message The SEL was cleared successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0136 Message Object value modified successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0138 Message Coredump request completed successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0139 Message Total Records: arg1 Arguments arg1 = Number of Records Detailed Description Success message. Recommended Response Action No response action is required.
SWC0141 Message Certificate successfully downloaded from the RAC Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0142 Message Certificate successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required.
SWC0144 Message Certificate successfully uploaded to the RAC. The RAC will now reset\nto enable the new certificate and may be offline temporarily. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0145 Message A CSR was generated successfully Detailed Description Success message.
SWC0147 Message ASR request completed successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0148 Message Test email sent successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0150 Message Object value is valid Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0151 Message RAC configuration saved to file successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0153 Message RAC configuration file is valid Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0154 Message Generating CSR. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
SWC0156 Message CSR file downloaded from RAC successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0157 Message User certificate successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required.
SWC0159 Message Kerberos Keytab successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0160 Message PK SSH Authentication Key file successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required.
SWC0201 Message All keys successfully deleted Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0202 Message Key successfully deleted Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0204 Message Key text successfully uploaded Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0205 Message Upload an SSL key to the RAC Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0207 Message Display the version info of RACADM Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0208 Message Disconnect Virtual Media connections Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0210 Message Display NIC teaming information Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0211 Message Perform vFlash operations Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0213 Message Disable the Virtual Console from a local Console Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0214 Message Makes a remote ISO image available to the server Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0216 Message The -c option requires -l to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0217 Message The -c option requires -u to also be specifed. Detailed Description The syntax of the command is incorrect.
SWC0219 Message The -p option requires -c to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0220 Message The -u option requires -c to also be specifed. Detailed Description The syntax of the command is incorrect.
SWC0222 Message Invalid syntax. The -d option is not valid with -c. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0223 Message Invalid syntax. The -d option is not valid with -p. Detailed Description The syntax of the command is incorrect.
SWC0225 Message Invalid syntax. The -d option is not valid with -l. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0226 Message No valid directory service certificate exists Detailed Description The Remote/Firmware racadm did not find any AD/LDAP certificate at specified path.
SWC0228 Message Partition label must be an alphanumeric character string. Detailed Description Invalid values passed to the function. Recommended Response Action Enter a shorter Partition label. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0229 Message Some Necessary tag(s) are missing: -i -o -e -t -f & -s must be specified for create partition. Detailed Description Insufficient arguments passed to the command.
SWC0231 Message Partition of type \"image\" not supported on local racadm. Detailed Description The partition image type specified is not available on local racadm. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0232 Message Remote RACADM commands are not supported on this iDRAC. To upgrade your iDRAC version, contact your service provider.
SWC0234 Message Remote host is not reachable or connection is interrupted. Detailed Description The remote host specified for the ftp update is not reachable. Recommended Response Action Check the connectivity between iDRAC and the remote host used for the ftp update. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0235 Message All keys successfully deleted.
SWC0237 Message Key text appears to be corrupted. Detailed Description The key text in the public key specified is corrupt. Recommended Response Action Request for a valid public key from the system and re-try the command. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0238 Message Key is too long. Detailed Description The key specified by the public key is too long.
SWC0240 Message The IPv6 DNS Server IP address is not allowed to be configured if IPv6 DNS Server DHCP (cfgIPv6DNSServersFromDHCP6) is enabled Detailed Description The requested object is auto-assigned if DNS Server DHCP is enabled, and hence cannot be configured. Recommended Response Action Disable DNS Server DHCP and re-try the command.
SWC0243 Message Certificate regenerated successfully and webserver restarted Detailed Description SSL Certificate is regenerated successfully and the Web server is restarted. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0244 Message Invalid Fully Qualified Device Descriptor (FQDD).
SWC0246 Message Value specified is invalid: Valid range is arg1 . Arguments arg1 = index Detailed Description The specified value is outside of the valid range. Recommended Response Action Verify that a valid value is specified. See the help text or documentation for valid values. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0247 Message Invalid subcommand specified.
SWC0249 Message Invalid syntax. The requestsed subcommand requires -i arg1 to be specified. Arguments arg1 = index Detailed Description The specified parameter needs to be given with its legal value. Recommended Response Action Enter the proper index preceeded by -i. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0250 Message Invalid syntax. The specified subcommand does not require any options.
SWC0252 Message No options were specified. The subcommand requires options to be used. Detailed Description Invalid number of arguments were passed to the command. Recommended Response Action Refer the help text for the command, and enter the required parameters. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0253 Message Unable to allocate memory needed to perform operation.
SWC0255 Message Unable to open file. Detailed Description Unable to open the specified file. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0256 Message Unable to read file. Detailed Description Unable to read the specified file. Recommended Response Action No response action is required.
SWC0258 Message Insufficient resources to perform operation. Detailed Description Insuffcient resources to execute the command. Recommended Response Action Power Cycle the system and re-enter the command. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0259 Message Invalid group specified. Detailed Description The value of specified parameter is invalid.
SWC0261 Message The specified option is not supported with the interface being used. Detailed Description The option requested is not available on the interface being used. Recommended Response Action Refer to the help to get the list of commands/options valid for the interface. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0262 Message Unable to perform operation. Please make sure RAC controller and \nappropriate I
SWC0264 Message Resource currently in use by another process. Please retry again later. Detailed Description The resources required for the execution are in use by another process Recommended Response Action Wait for the process to release the resources and try again. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0265 Message This option is not supported on this type of DRAC.
SWC0267 Message Unable to perform the requested operation. Make sure a non write protected SD card is inserted. Detailed Description Unable to edit the SD card, since it is write protected. Recommended Response Action Check if the SD card is write protected. If yes, disable the write protection.
SWC0270 Message Unable to clear the SEL. \nPossible reason may be that Local Configuration using RACADM is disabled. Detailed Description Local Configuration using RACADM may be disabled. Recommended Response Action Check if the Local Configuration using RACADM is disabled and enable it through GUI. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0271 Message Invalid syntax. The -f option is only valid with -p and -c.
SWC0273 Message Invalid syntax. The -g option requires -o to also be specified. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0274 Message Invalid syntax. An object value must be specified. Detailed Description The value of specified parameter is invalid.
SWC0276 Message Invalid syntax. The -p option is only valid with -f. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0277 Message Invalid syntax. The -i option is only valid with -g and -o. Detailed Description The syntax for the config command is invalid.
SWC0279 Message The specified group is not indexed and does not support -i. Detailed Description The group is not indexed and does not require an index to be specified. Recommended Response Action Enter the command without the index. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0280 Message The indexed group specified requires -i arg1 .
SWC0282 Message The specified object is READ ONLY for this index and cannot be modified. Detailed Description The value being modified is READ only. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0283 Message The specified object value is not valid. Detailed Description The value given for the object is not valid.
SWC0285 Message Object value is invalid. Detailed Description The value given for the object is not valid. Recommended Response Action Enter a valid value for the corresponding object. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0286 Message Modifying the user configuration at index 1 is not allowed. Detailed Description Objects in the cfgUserAdmin group corresponding to index 1 cannot be modified.
SWC0288 Message Object arg1 in arg2 group must be specified. Line: arg3 Arguments arg1 = object name, arg2 = group name, arg3 = line no. Detailed Description The object specified in the message in the group specified in the message is not configured. Recommended Response Action Configure the object specified in the message in specified group, before performing a config to file action.
No alerts are applicable for this message SWC0291 Message Another object exists with the specified value. Duplicate values are\nnot allowed for the requested object. Detailed Description Another object of the same value exists. Typically in the case of username. Recommended Response Action Change the specified value and re-try.
SWC0294 Message Invalid group name specified. Detailed Description The group name specified is incorrect. Recommended Response Action Refer to the list of groups available and choose the correct one. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0295 Message Invalid object name specified. Detailed Description The object name specified is incorrect.
SWC0297 Message Unable to remove passwords because file could not be saved. Detailed Description After the Groups are downloaded to a file, the passwords are to be deleted. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 2 (Warning) No alerts are applicable for this message SWC0298 Message The specified object value cannot be configured if local configuration is disabled or smart card logon is enabled.
SWC0300 Message There is no coredump currently available. Detailed Description There is no coredump available to display. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0301 Message The specified IP address is not valid. Detailed Description The IP address provided is not valid. Recommended Response Action Specify a valid IP Address.
SWC0303 Message The -r option is not valid with any other option. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0304 Message The -g option requires -u to also be specifed. Detailed Description The syntax of the fwupdate command is invalid.
SWC0306 Message The -a option requires -g and -u to also be specifed. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0307 Message The -d option requires -p or -g to also be specifed. Detailed Description The syntax of the fwupdate command is invalid.
SWC0309 Message The -p option is not supported with the interface being used. Detailed Description The platform does not support the specified functionality of fwupdate. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0310 Message Invalid syntax. The -f is not valid with the option specified.
SWC0312 Message Invalid syntax. The -u option is not valid with any other options. Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0313 Message Invalid syntax. The -h option is not valid with any other options.
SWC0315 Message Failed to get object value. Detailed Description The getconfig subcommand failed to get the object value. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0316 Message The index must be greater than 0. Detailed Description The value for index must be greater than zero. Recommended Response Action Enter a positive value for index.
SWC0318 Message The starting record must be greater than zero. Detailed Description The value for -s must be greater than zero. Recommended Response Action Enter a value greater than zero, for the option -s. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0319 Message The -i option is not valid with any other options. Detailed Description The syntax for the getraclog command is invalid.
SWC0321 Message Unable to open the log for reading. Detailed Description Could not open the log file for reading. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0322 Message Starting record specified exceeds number of records available. Detailed Description The starting record value has to be lesser than the number of records available.
SWC0324 Message There are no records available to display. Detailed Description There are no records to display. This might be a result of the log being cleared. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0325 Message The specified object is WRITE-ONLY and cannot be displayed. Detailed Description The requested property is write-only.
SWC0701 Message Power capping is enabled. Detailed Description Power capping is enabled and sets user-defined power capping limits for the system. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) No alerts are applicable for this message SWC0702 Message Power capping is disabled. Detailed Description Power capping is disabled and sets recommended limits for the system.
SWC0722 Message Error occurred while resetting to defaults. The reset command was not accepted. Detailed Description iDRAC is processing a previous reset to default command. Recommended Response Action Retry after a few minutes. Category Configuration (SWC = Software Config) Severity Severity 1 (Critical) No alerts are applicable for this message SWC0723 Message Error occurred while Resetting to defaults. The Reset status is not available.
SWC1903 Message RAC SSL Certificate has been changed. Detailed Description RAC SSL Certificate has been changed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1909 Message User ID arg1 RAC Privilege has been changed. Arguments arg1 = username Detailed Description The privilege level of the iDRAC User ID indicated in the message has been changed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1911 Message User ID arg1 User Password has been changed. Arguments arg1 = username Detailed Description User ID Password has been changed. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1913 Message Network Time Protocol configuration is enabled. Detailed Description Network Time Protocol configuration is enabled. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC1915 Message iDRAC time zone has changed. Detailed Description iDRAC time zone has changed. Recommended Response Action No response action is required.
Detailed Description Network Time Protocol server configuration has changed. Recommended Response Action No response action is required. Category Audit (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1917 Message HTTPS redirection is disabled.
SWC1918 Message HTTPS redirection is enabled. Detailed Description HTTP to HTTPS redirection is enabled. Any iDRAC connection made over the HTTP port (default port number 80) will be redirected to the secure HTTPS port (default port number 443). Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1921 Message The Chassis Management at Server Mode is disabled. Detailed Description The Chassis Management at Server Mode is disabled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1923 Message Unable to modify the server configuration by using Quick Sync because invalid credentials are entered. Detailed Description The server configuration cannot be modified by using Quick Sync because invalid credentials are entered.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1925 Message The iDRAC Quick Sync access feature is set to the Disabled mode. Detailed Description The iDRAC Quick Sync access feature is set to the Disabled mode. Recommended Response Action No response action is required.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1927 Message The iDRAC Quick Sync access feature is set to the read-only mode. Detailed Description The iDRAC Quick Sync access feature is set to the read-only mode. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC WS Eventing ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SWC1929 Message The iDRAC Quick Sync inactivity timeout value is set to arg1 .
Detailed Description The iDRAC Quick Sync feature is set to automatically disable after a specified inactivity time. Recommended Response Action No response action is required.
SWC4004 Message A firmware or software incompatibility detected between iDRAC in slot arg1 and CMC. Arguments arg1 = number Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions of iDRAC and CMC. Update to latest version.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SWC4006 Message A firmware or software incompatibility detected between system BIOS in slot arg1 and CMC. Arguments arg1 = number Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware.
Recommended Response Action No response action is required. Category System Health (SWC = Software Config) Severity Severity 3 (Informational) Trap/EventID 2339 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔* LCD Reset Chassis Event Proxy ✔ ✔* SWC4008 Message A firmware or software incompatibility detected between CMC 1 and CMC 2.
SWC4009 Message A firmware or software incompatibility was corrected between CMC 1 and CMC 2. Detailed Description None Recommended Response Action No response action is required.
SWC4011 Message A firmware or software incompatibility is automatically corrected between the arg1 arg2 in Server- arg3 and the Chassis Management Controller (CMC). Arguments arg1 = network device name, arg2 = network device location, arg3 = server location Detailed Description A firmware or software incompatibility was automatically corrected between the network device in the Server identified in the message and the Chassis Management Controller (CMC).
LC Log LCD OS Log iDRAC ✔ ✔ CMC ✔* ✔ Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC4013 Message A firmware or software incompatibility was corrected between arg1 arg2 and arg3 arg4 . Arguments arg1 = first component name, arg2 = first component location, arg3 = second component name, arg4 = second component location Detailed Description A firmware or software incompatibility was corrected between the components identified in the message.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC5001 Message arg1 upgrade failed. Arguments arg1 = name Detailed Description None Recommended Response Action Reboot the system and attempt the upgrade again.
Recommended Response Action Check system logs for minor errors. Category System Health (SWC = Software Config) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SWC5003 Message System Controller (SC) has either stopped functioning or is updating a firmware version.
SWC5005 Message Unable to update the System Controller (SC) firmware Detailed Description The System Controller (SC) firmware cannot be updated. For information about the causes, see SEL Event Data Byte 2. Recommended Response Action Retry the SC firmware update operation. If the issue persists, try updating by using a different firmware update file.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8501 Message Unable to generate Profile. Detailed Description Unable to communicate with iDRAC. Recommended Response Action Check if iDRAC is ready and system is running properly. Utilize the RACADM command by running "racadm getversion" to list all the servers and make sure the iDRAC version is displayed.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8503 Message arg1 Profile is renamed to arg2 Arguments arg1 = profile name, arg2 = new profile name Detailed Description The Profile identified in the message has been renamed.
Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8505 Message arg1 Profile description edited.
Arguments arg1 = profile name Detailed Description The Profile identified in the message has been deleted. Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8507 Message arg1 Profile created.
SWC8508 Message Unable to capture Profile from server in slot arg1 Arguments arg1 = slot number Detailed Description Unable to communicate with iDRAC. Recommended Response Action Check if iDRAC is ready and system is running properly. Utilize the RACADM command by running "racadm getversion" to list all the servers and make sure the iDRAC version is displayed. If the iDRAC is listed as Not Ready then wait until it becomes ready. A Virtual Reseat may be required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8510 Message Unable to apply arg1 Profile to requested Server(s) Arguments arg1 = profile name Detailed Description Unable to communicate with the iDRAC of the requested Server. Recommended Response Action Check if iDRAC is ready and system is running properly.
Recommended Response Action No response action is required.
Arguments arg1 = user name Detailed Description The user name identified in the message was successfully deleted. Recommended Response Action No response action is required.
SWC8515 Message Successfully modified privileges of User arg1 . Arguments arg1 = user name Detailed Description Successfully modified privileges of User identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8517 Message Successfully modified password of User arg1 . Arguments arg1 = user name Detailed Description Successfully modified the password for the User identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8519 Message Successfully modified user name from arg1 to arg2 . Arguments arg1 = original user name, arg2 = new user name Detailed Description The user name identified in the message was successfully modified. Recommended Response Action No response action is required.
Recommended Response Action Make sure: 1) The login credentials for the operation have user config administration privilege, 2) The user name given is valid. If the issue persists, restart the CMC and retry the operation.
Arguments arg1 = member id Detailed Description Successfully completed a configuration sync with the member identified in the message. Recommended Response Action No response action required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8524 Message Unable to add arg1 to Chassis Group because a member already exists with the same addressing information. Arguments arg1 = target Detailed Description A Chassis Group member already exists with the same hostname or IP address information as the target identified in the message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8526 Message Unable to delete Chassis Group member arg1 ( arg2 ) Arguments arg1 = member id, arg2 = DNS or IP address of member Detailed Description Unable to delete Chassis Group member identified in the message.
Recommended Response Action Make sure the user name is valid. If communication with iDRAC is not successful, reset the iDRAC. Retry the operation after a few minutes.
SWC8529 Message Chassis Management Controller unable to enable the iDRAC root user. Detailed Description The Chassis Management Controller is unable to enable the iDRAC root user. This can happen if the communication to the iDRAC from CMC is non-functional or iDRAC is rebooting Recommended Response Action If communications with the iDRAC is not functioning, reset the iDRAC and retry the operation after a few minutes. Run the RACADM command "racadm ping server " to check the communications.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8531 Message Chassis Management Controller unable to set iDRAC administrator role for root user account. Detailed Description The Chassis Management Controller is unable to set the administrator role for the iDRAC root user.
Recommended Response Action Make sure there are enough IPv4 addresses for all the iDRACs and then retry the operation.
Detailed Description All keys saved in the Chassis Management Controller for PK SSH Authentication are deleted. Recommended Response Action No response action is required.
SWC8536 Message Unable to add key for slot arg1 of service account, due to corrupt key. Arguments arg1 = slot number Detailed Description The add key operation did not complete successfully for the slot identified in the message due to the key being invalid or corrupt. Recommended Response Action Retry the operation. If the issue persists, contact your service provider.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8538 Message Unable to delete key for slot arg1 of service account, due to problem saving key file. Arguments arg1 = slot number Detailed Description The Public Key (PK) SSH Authentication key file delete operation did not complete successfully because the Chassis Management Controller is unable to access the configuration database. Recommended Response Action Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8540 Message The add key operation successfully completed for slot arg1 of service account. Arguments arg1 = slot number Detailed Description The Public Key (PK) SSH Authentication key file is successfully uploaded to the Chassis Management Controller.
Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8542 Message The Profile arg1 is exported. Arguments arg1 = profile name Detailed Description The Profile identified in the message is exported. Recommended Response Action No response action is required.
Recommended Response Action Make sure that profile versions are compatible with target servers when attempting application of profiles to servers.
Arguments arg1 = server number Detailed Description The system is busy with other operations. The feature was unable to get mutex. Recommended Response Action Retry the operation. If the issue persists, make sure any other operations have completed and then retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8604 Message Quick Deploy Profile: Server arg1 does not support configuration using profiles. Arguments arg1 = server number Detailed Description The target server identified in the message does not support server configuration using profiles. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8606 Message Quick Deploy Profile: Timeout exceeded while waiting for remote services ready on Server arg1 . Arguments arg1 = server number Detailed Description The server identified in the message never reported that remote services were ready.
Detailed Description The Quick Deploy of Profile process has started for the server identified in the message.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8609 Message Server Profiles: unknown response received from server: arg1 for operation [ arg2 ] because of one or more of the following reasons: 1) iDRAC is not ready. 2) Lifecycle Controller of the server is disabled.
Recommended Response Action No response action is required. Category Configuration (SWC = Software Config) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWC8611 Message Profile " arg1 " and Server (Service Tag: arg2 in Slot arg3 ) are not compatible.
Arguments arg1 = profile name Detailed Description The profile identified in the message does not contain boot device information in a usable format. Recommended Response Action Recreate the profile identified in the message or use a different profile.
SWC8614 Message Legacy profile setting: arg1 is not recognized. Arguments arg1 = attribute name Detailed Description The setting identified in the message is not recognized because the profile is not in a usable format or contains settings that are no longer supported. Recommended Response Action Recreate the profile or use a different profile.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWC8616 Message Server in slot arg1 is not ready to be accessed remotely because of one or more of the following reasons: 1) iDRAC is not ready. 2) Lifecycle Controller for of the server is disabled. Arguments arg1 = slot number Detailed Description The server identified in the message cannot be accessed remotely by iDRAC because of one or more of the following reasons: 1) iDRAC is not ready.
Recommended Response Action Make sure that iDRAC is ready and system is functioning properly. Run the RACADM command "racadm getversion" to list all the servers and make sure the iDRAC version is displayed. If the iDRAC is listed as Not Ready then wait until iDRAC is ready for use. A Virtual Reseat may be required.
SWC8619 Message The Chassis Management Controller is unable to process data from the server in slot arg1 . Arguments arg1 = slot id Detailed Description The Chassis Management Controller (CMC) is unable to process inventory data from the server in the slot identified in the message. This can happen if: 1) There is a communications issue between the CMC and the iDRAC on the server identified in the message. 2) Incorrect firmware is installed on network cards.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔* CMC ✔ ✔* LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* SWC8621 Message The Chassis Management Controller is unable to process inventory data from the server in slot arg1 . Arguments arg1 = slot id Detailed Description The Chassis Management Controller (CMC) is unable to process inventory data from the server slot identified in the message.
Detailed Description The remote network share settings are accessible on the CMC web interface at Server Overview/Setup/Remote Network Share tab. These settings must be correct for the CMC to connect to the remote network share and perform the application of the profile as specified in the Quick Deploy tab on the Profiles page. Recommended Response Action Make sure that the remote network share settings in the CMC are correct and that the remote share NFS/CIFS server is functioning correctly.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* SWC8624 Message The network communication session between CMC and I/O Aggregator cannot be started on arg1 . Arguments arg1 = slot id Detailed Description The network communication session between CMC and I/O Aggregator (IOA) cannot be started because the IOA did not respond. Recommended Response Action Power-cycle the IOA and retry the operation.
SWU Event Messages SWU001 Message The expander or storage enclosure processor firmware is successfully updated. Detailed Description The expander or storage enclosure processor firmware is successfully updated. Recommended Response Action No response action is required. Category Storage (SWU = Software Change) Severity Severity 3 (Informational) No alerts are applicable for this message SWU002 Message The backplane firmware update did not complete successfully.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8501 Message The reinstall/rollback request to Lifecycle Controller on server arg1 was not successful. Arguments arg1 = slot number Detailed Description This message is displayed when: 1. A reboot job is unable to provide a valid reboot ID. 2.
Recommended Response Action No response action required. Category Updates (SWU = Software Change) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8503 Message A reinstall/rollback request was submitted to the Lifecycle Controller on server arg1 .
SWU8504 Message Successfully scheduled the arg1 operation on the server arg2 . Arguments arg1 = update/reinstall/rollback, arg2 = slot number Detailed Description The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria. Recommended Response Action No response action required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8506 Message Completed the Firmware update operation for CMC arg1 . Arguments arg1 = slot number Detailed Description Completed the Firmware update operation for the CMC identified in the message.. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8514 Message Unable to update the IOM infrastructure firmware of slot arg1 . ErrorCode=0x arg2 . Arguments arg1 = slot number, arg2 = error no Detailed Description The IOM infrastructure firmware update operation is not successful.
Recommended Response Action Retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8516 Message Unable to update the iDRAC firmware on the server in slot arg1 . Transfer is not successful. ErrorCode=0x arg2 .
SWU8517 Message Unable to update the iDRAC firmware on the server in slot arg1 . The Image file is not accessible. ErrorCode=0x arg2 . Arguments arg1 = slot number, arg2 = error no Detailed Description Unable to update the iDRAC firmware. The firmware Image file is not accessible. Recommended Response Action Make sure the iDRAC firmware Image file is available in the given path and retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8519 Message The firmware update operation of the iDRAC on the server in slot arg1 is stopped. The Image file is corrupted. Arguments arg1 = slot number Detailed Description The iDRAC firmware update operation was stopped, because the Image file is corrupted. Recommended Response Action Reacquire the Image file from the original source, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8521 Message The firmware update operation of the iDRAC on the server in slot arg1 was stopped. The selected Image file is not compatible with the server hardware. Arguments arg1 = slot number Detailed Description The firmware update operation of iDRAC identified in the message was stopped.
Recommended Response Action Reacquire the Image file from the original source, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8523 Message The firmware update operation of the iDRAC on the server in slot arg1 is successfully completed.
SWU8524 Message Unable to update the iDRAC on the server in slot arg1 firmware: ErrorCode=0x arg2 . Arguments arg1 = slot number, arg2 = error no Detailed Description The firmware update operation is not successful. This may be due to a problem encountered by the firmware, or because a server was removed during the firmware update operation. Recommended Response Action Reacquire the Image file from the source folder, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8526 Message The firmware update operation of the iDRAC on the server in slot arg1 is initiated. Arguments arg1 = slot number Detailed Description The firmware update operation of iDRAC identified in the message is initiated. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8528 Message Unable to update the iKVM firmware, because of a checksum error. Detailed Description The process of iKVM firmware update is not successful due to a checksum error of the firmware image.
Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8530 Message Unable to update the iKVM firmware. Detailed Description The process for iKVM firmware update was not successful.
Recommended Response Action Retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8532 Message Unable to update the LKVM firmware, because an invalid parameter is entered. ErrorCode=0x arg1 .
SWU8533 Message Unable to update the LKVM firmware, because the target is not ready. ErrorCode=0x arg1 . Arguments arg1 = error no Detailed Description The LKVM firmware update operation is not successful, because the target is not ready. Recommended Response Action Wait for the target to become ready. This may take a few minutes. After the target is ready, then retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8535 Message Unable to update the LKVM firmware, because the Image file transfer is not successful. ErrorCode=0x arg1 . Arguments arg1 = error no Detailed Description The LKVM firmware update operation was not successful, because the firmware Image file could not be transferred.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8537 Message Unable to update the LKVM firmware, because the IP address provided is invalid. ErrorCode=0x arg1 . Arguments arg1 = error no Detailed Description The LKVM firmware update operation was not successful, because the IP address of the active CMC that is provided to the LKVM is invalid.
Recommended Response Action Retry the Update operation. If the issue persists, reinsert the iKVM and retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8540 Message Unable to update the PSU firmware, because the transfer of Image file is not successful.
SWU8541 Message Unable to update the PSU firmware, because the Image file is not accessible. ErrorCode=0x arg1 . Arguments arg1 = error no Detailed Description The PSU firmware update operation was not successful, because the firmware Image file could not be transferred. Recommended Response Action Make sure that the PSU firmware image file is available at the location specified in the operation, and then retry the operation.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* SWU8543 Message Unable to update the Active CMC firmware. The Image file was not accessible. Detailed Description The firmware update operation of CMC was not successful. The Image file was not accessible. Recommended Response Action Make sure that the CMC firmware image file is available at the location specified in the operation, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8545 Message Unable to update the Standby CMC firmware. Detailed Description The firmware update operation of the Standby CMC was not successful. Recommended Response Action Retry the update operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8547 Message Unable to update the Standby CMC firmware. The Image transfer process was not successful. Detailed Description The firmware update operation of Standby CMC was not successful. The firmware image could not be transferred.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8549 Message Unable to update the firmware of Standby CMC and Active CMC. The checksum process was not successful. Detailed Description The firmware update process of Active CMC and Standby CMC was not successful, because of a firmware image checksum error.
Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8551 Message Unable to update the firmware of Active CMC. The checksum process was not successful. Detailed Description The firmware update process of Active CMC was not successful, because of a firmware image checksum error.
Recommended Response Action Reacquire the Image file from the source location, and then retry the operation. Category Updates (SWU = Software Change) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8553 Message Unable to update the Active CMC firmware. The Image file was not accessible.
Detailed Description Local CMC firmware update process is initiated. Recommended Response Action No response action is required. Category Updates (SWU = Software Change) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SWU8555 Message Active CMC and Standby CMC firmware updates have been initiated.
SWU8556 Message Unable to configure the sled network uplink on sled arg1 . Arguments arg1 = slot number Detailed Description The sled network uplink on the sled identified in the message could not be configured. The servers on the sled may not have expected network connectivity. Recommended Response Action Perform a Virtual Reseat operation, and then retry the operation.
SWU8558 Message Invalid firmware: The uploaded firmware image validation was unsuccessful. Detailed Description Invalid firmware: The uploaded firmware image validation was unsuccessful. Recommended Response Action Use a valid firmware image and retry the operation. Category Audit (SWU = Software Change) Severity Severity 2 (Warning) No alerts are applicable for this message SWU8559 Message The firmware downgrade operation is unsuccessful.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC ✔* CMC ✔* Reset Chassis Event Proxy ✔* SWU8561 Message Unable to downgrade the firmware version because the current hardware configuration does not support rollback to the earler firmware version. Detailed Description The firmware version selected for rollback does not support the current chassis hardware configuration.
Detailed Description The IOA firmware cannot be updated because of an issue in the network communication session between CMC and IOA. Recommended Response Action Power-cycle the IOA and if the firmware version is unchanged, retry the firmware update operation.
SYS Event Messages SYS001 Message The operation was successful. Detailed Description The operation requested successfully completed. Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS002 Message Unable to perform the operation due to an unknown error in iDRAC. Detailed Description The operation did not complete successfully because of an unknown error in iDRAC.
SYS004 Message Invalid parameter value for arg1 . Arguments arg1 = parameter name Detailed Description The value provided for the specified parameter is invalid. Recommended Response Action Refer to the Lifecycle Controller Remote Services documentation and retry the operation with a valid value for the identified parameter.
SYS007 Message Input out of range for arg1 . Arguments arg1 = attribute name Detailed Description The input value for the attribute being set is not within the acceptable range for the attribute. Recommended Response Action Refer to the Lifecycle Controller-Remote Services documentation for the specific attribute and retry the operation with valid value within the range of the attribute.
No alerts are applicable for this message SYS010 Message Invalid character in value for attribute: arg1 Arguments arg1 = attribute name Detailed Description The input value for the specified attribute is not valid. Recommended Response Action Refer to Lifecycle Controller-Remote Services documentation and provide valid attribute value for the specified attribute.
No alerts are applicable for this message SYS013 Message Invalid attribute name: arg1 . Arguments arg1 = attribute name Detailed Description The attribute name provided for the requested operation does not exist on the target system or is invalid. Recommended Response Action For more information, see Lifecycle Controller-Remote Services documentation.
No alerts are applicable for this message SYS016 Message Job completed with errors Detailed Description All the operations in the Job were attempted, but some did not complete successfully. Recommended Response Action Review the Job content and verify the values are correct. For more information, see Lifecycle Controller Remote Services documentation.
SYS019 Message Required dependency input not found. Detailed Description The input is missing a required dependency necessary for the operation. Recommended Response Action Provide the required dependency and retry. For more information, see Lifecycle Controller Remote Services documentation. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS020 Message Invalid required Attribute value.
SYS022 Message Resource allocation failure. Detailed Description The operation could not complete because of an internal resource allocation issue with the firmware. Recommended Response Action Reset the iDRAC and retry the operation. Category Configuration (SYS = System Info) Severity Severity 1 (Critical) No alerts are applicable for this message SYS023 Message No configuration changes pending. Detailed Description There are no pending values to change.
No alerts are applicable for this message SYS025 Message Unable to delete pending configuration. Detailed Description There are no pending configurations to be deleted. Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS029 Message Unsupported parameter name arg1 . Arguments arg1 = parameter name Detailed Description The parameter name is not supported.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS031 Message Updating component configuration. Detailed Description The configuration is being applied to a component. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS033 Message Staged component configuration completed with errors. Detailed Description The staged component configuration update performed in the UEFI environment on the host system has completed, but there were errors. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS035 Message Some configuration values were not applied to: arg1 Arguments arg1 = device name Detailed Description The component configuration operation was completed, however some of the configuration values were not successfully applied.
Recommended Response Action Retry the operation or try the attribute set operation for the component. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS037 Message Component update initialization failure. Detailed Description Operation validation is unsuccessful.
Detailed Description Unable to locate the configuration data associated with the job. Recommended Response Action Retry the operation. If this issue persists, contact your service provider.
SYS040 Message The firmware update operation did not complete successfully. Detailed Description An operation to update the frmware of a component did not complete successfully. Recommended Response Action Check the Lifecycle Log for more details about the unsuccessful operation. Resolve the issue and retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS042 Message Component configuration successfully completed. Detailed Description The requested component configuration successfully completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS044 Message Unable to export one or more component configurations. Detailed Description Unable to collect the configuration information for one or more components. An internal error occurred while processing component information.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS046 Message Unable to import the system configuration XML file from the network share. Detailed Description An error occurred while copying the system configuration XML file from the network share. Recommended Response Action If the file is being copied from an NFS share, make sure that it is accessible from iDRAC.
Category Configuration (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS048 Message System configuration XML input file contains invalid characters, arg1 at line arg2 .
Detailed Description The system configuration XML file for the import configuration operation is not compliant with schema nesting checks. Only RAID controllers can have nested Component nodes up to a maximum nesting depth of three. Recommended Response Action Make sure that the system configuration XML file is compliant with the system configuration schema published on delltechcenter.com/lc in the LC XML Schema Guide. Only RAID controllers can have nested Component nodes.
SYS052 Message Analyzing iDRAC, System, or Lifecycle Controller configuration for changes to be applied. Detailed Description Configuration changes that do not require a system restart are currently being applied. Recommended Response Action No response action is required.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS054 Message No configuration changes requiring a system restart need to be applied. Detailed Description The current configuration for components that require staged configuration already match the configuration specified by the input file. A system restart to apply staged configuration is not required. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS056 Message Waiting for the system to shut down. Detailed Description Waiting for the system to shut down before applying configuration changes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS058 Message Applying configuration changes. Detailed Description Running Lifecycle Controller Automated Task Execution application in Unified Extensible Firmware Interface (UEFI) environment to apply configuration changes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS060 Message Component configuration completed with errors. Detailed Description Some configuration changes for the component identified by the Fully Qualified Device Descriptor (FQDD) in the configuration job results were not successfully applied.
Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS062 Message Input file for import configuration operation is invalid. The expected XML root element was not found. Detailed Description The input file for the import configuration operation does not contain a valid XML root element.
Recommended Response Action Open the input file in any Web browser to check for invalid content before the expected root element. Correct the invalid content and make sure that the XML file is compliant to the system configuration schema before retrying the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS066 Message No changes detected for iDRAC, System, or Lifecycle Controller configuration. Detailed Description No iDRAC, System, or Lifecycle Controller configuration changes were applied. The settings specified in the system configuration XML input file match the current configuration for these components.
Category Configuration (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS068 Message Configuration changes that require system reboot were not applied. Detailed Description Some configuration changes that require system reboot were not applied because the values specified in the input XML file are incorrect.
Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS070 Message Configuration changes that require system reboot were not applied.
Detailed Description The export of system configuration XML did not complete because the operation took too long. Recommended Response Action Make sure the Collect System Inventory On Restart (CSIOR) Lifecycle Controller setting is enabled and reboot the system. Retry the operation after CSIOR has completed. If the problem persists, reset iDRAC by pressing the System ID button for at least 15 seconds and retry the operation after iDRAC has fully restarted.
SYS073 Message Unable to apply changes that require system reboot because the Lifecycle Controller State setting is disabled in the configuration XML. Detailed Description The import of system configuration XML file operation completed with errors because the Lifecycle Controller State was disabled in the input XML. Configuration changes requiring a system reboot were not applied. Recommended Response Action Enable the Lifecycle Controller State setting and retry the operation.
Detailed Description Unable to perform the import operation because the specified file does not exist on the remote share. Recommended Response Action Make sure the import configuration file exists on the remote share before retrying the operation. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS076 Message Invalid or unsupported component specified in the input configuration XML file.
Detailed Description Unable to retrieve the system configuration XML file from the network share for the requested preview operation. This may be due to issues with network accessibility. Recommended Response Action If the configuration XML file is on an NFS share, make sure that the network share is accessible from iDRAC. If the configuration XML file is on a CIFS share, make sure that the network share is accessible from iDRAC using the share credentials specified.
SYS081 Message Successfully previewed system configuration XML file import operation. Detailed Description Successfully previewed system configuration XML file import operation. Recommended Response Action No response action is required. Category Configuration (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS082 Message Completed the preview of system configuration XML file import operation.
Severity Severity 2 (Warning) No alerts are applicable for this message SYS084 Message Export of ePSA Diagnostics results did not complete successfully because the iDRAC internal storage containing the results could not be accessed. Detailed Description Export of ePSA Diagnostics results did not complete successfully because the iDRAC internal storage containing the results could not be accessed.
No alerts are applicable for this message SYS087 Message A system reboot will occur when the previewed configuration XML file is imported to the system. Detailed Description When the configuration XML file specified in the Preview operation is imported to the system, a system reboot will occur to apply the configuration changes. Recommended Response Action No response action is required.
SYS090 Message The configuration XML input file contains unsupported DOCTYPE tags. Detailed Description The configuration XML Input file contains XML DOCTYPE tags which may contain injection security threats. The XML DOCTYPE tag is not supported in configuration XML files. Recommended Response Action Check the input XML file for DOCTYPE XML tags and remove them before retrying the operation.
SYS093 Message The iDRAC is exporting the Tech Support Report. Detailed Description The iDRAC is exporting the Tech Support Report to the specified destination. Recommended Response Action No response action is required. Category System Health (SYS = System Info) Severity Severity 3 (Informational) No alerts are applicable for this message SYS094 Message The iDRAC is unable to start the Tech Support Report job, because a report collection job is already running on the server.
SYS096 Message Unable to complete the diagnostics operation because the required Dell Diagnostics firmware package is not installed. Detailed Description The required Dell Diagnostics firmware package is not installed or cannot be found in the iDRAC internal storage. Recommended Response Action Install the Dell 64bit uEFI Diagnostics firmware package, and then retry the operation. The Dell Diagnostics can be installed using the Dell 64bit uEFI Diagnostics Dell Update Package (DUP).
SYS099 Message Unable to export the diagnostics results because the results do not exist. Detailed Description The diagnostics results could not be exported because either the diagnostics tests were never run on the system or the results could not be found on the internal storage of the iDRAC. Recommended Response Action Run the RunEPSADiagnostics method to make sure that the diagnostics results are available, and then retry the operation.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SYS1001 Message System is turning off. Detailed Description System is turning off. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 8579 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC SYS1003 Message System CPU Resetting. Detailed Description System is performing a CPU reset because of system power off, power on or a warm reset like CTRL-ALT-DEL. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Audit (SYS = System Info) Severity Severity 3 (Informational) OMSA Event ID 5008 Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS102 Message Server Administrator Data Manager service has stopped. Detailed Description The Server Administrator Data manager service has stopped.
SYS103 Message Administrator has started. Detailed Description The Server Administrator has started. Recommended Response Action No response action is required.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS105 Message Unable to process the event: arg1 Date and time of event: arg2 . Arguments arg1 = event, arg2 = date time Detailed Description The current software version is unable to process this event because of an internal error. Recommended Response Action Contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS107 Message A system reboot was initiated by the user. Detailed Description The user initiated a system reboot. Recommended Response Action No response action is required.
Category Audit (SYS = System Info) Severity Severity 3 (Informational) OMSA Event ID 5007 OMSA Trap ID 5007 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS109 Message A system power cycle was initiated by the user. Detailed Description The user has initiated a system power cycle action.
SYS110 Message The actions Shutdown OS First and Reboot System were initiated by the user. Detailed Description The actions will shut down the operating system and then reboot the system. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS112 Message The actions Shutdown OS First and Power Cycle System were initiated by the user. Detailed Description The actions will shut down the operating system and then power cycle the system. Recommended Response Action No response action is required.
Category Audit (SYS = System Info) Severity Severity 3 (Informational) OMSA Event ID 5007 OMSA Trap ID 5007 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS114 Message The IPMI status for the interface: arg1 , Baseboard Management Controller (BMC): arg2 , Sensor Data Records (SDR): arg3 , System Event Log (SEL): arg4 .
SYS115 Message The power cord sensor is non-functional. Detailed Description The power cord sensor becomes non-functional because of one of the following reasons: 1) The power cable may not be connected properly or disconnected. 2) The power cord sensor in the power supply unit has failed. However, the power supply unit may still function. 3) There is an input power failure. Recommended Response Action Do of the following to resolve the issue: 1) Reconnect the power cord to the power supply unit.
LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS117 Message The input power supply is restored. Detailed Description The input power supply is restored to the system. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy iDRAC CMC SYS119 Message Unable to expose the OS Collector to the server OS. Detailed Description The OS collector cannot be exposed to the host server because of communication issues between the iDRAC and server OS. Recommended Response Action Do the following: 1) Retry the operation.
OC Collector update package and then select the Update and Rollback link from the iDRAC Web UI home page and upload the install package. If the issue persists, contact your service provider.
Detailed Description The operation to collect OS and Application Data is successfully completed. Recommended Response Action No response action is required. Category System Health (SYS = System Info) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS123 Message OS Collector: An unexpected issue has been encountered.
SYS124 Message OS Collector: The OS Collector application does not support execution in the OS installed on the server. Detailed Description The OS and Application data collection by the OS Collector application is unable to execute on the OS installed on the server because the OS is not supported. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS126 Message OS Collector: Unable to collect Application Data. Detailed Description Application data source was not found. An issue occurred while collecting Application Data because of an unknown exception. Recommended Response Action Do the following: 1) Retry the operation. 2) If the issue persists, reinstall the latest OS Collector on the iDRAC, and then retry the operation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS128 Message OS Collector: Unable to generate a zip archive of the OS and Application Data report. Detailed Description Unable to generate a zip archive of the OS and Application Data report. Recommended Response Action Do the following: 1) Retry the operation. 2) If the issue persists, reinstall the latest OS Collector on the iDRAC, and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS130 Message OS Collector: Unable to create filename for zip archive. Detailed Description Unable to create the final zip archive name because the Service Tag and time stamp could not be retrieved from OS interfaces.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS132 Message OS Collector: Unable to communicate with OS Collector IPMI library. Detailed Description An issue occurred while loading the OS Collector IPMI library. This may be because the OS collector binary images are not valid and need to be re-installed.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS134 Message OS Collector: Zip archive size exceeded the limit. Detailed Description The report size is more than the 30MB allowed size which will cause a truncated, partial report to be generated. Recommended Response Action Remove older log entries so that the final zip archive size can be reduced.
Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS136 Message An issue was encountered while communicating with iDRAC Service Module (iSM) present on the operating system. Detailed Description An issue was encountered while communicating with iDRAC Service Module (iSM) present on the operating system.
Recommended Response Action Enable the Lifecycle Controller by pressing F2 during server startup and select iDRAC Settings > Lifecycle Controller and then enable the Lifecycle Controller. Retry the operation after the server has restarted.
Detailed Description Unable to start the collection of OS and Application Data because the server is in POST and has not finished startup. Recommended Response Action Retry the operation after the server has finished starting and POST has completed.
SYS141 Message Lifecycle Controller data is deleted. Detailed Description The Lifecycle Controller data is deleted because of a System Erase operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS143 Message ePSA Diagnostics are deleted. Detailed Description ePSA Diagnostics are deleted because of a System Erase operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS145 Message vFlash SD Card data is deleted. Detailed Description vFlash SD Card data is deleted because of a System Erase operation. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS147 Message Starting non-secure erase-capable drive erase operations. Detailed Description Starting non-secure erase-capable drives erase operations because of a System Erase operation request. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS149 Message The process of resetting iDRAC to default settings is initiated. Detailed Description Initiating iDRAC reset to defaults operation because of a System Erase operation. The iDRAC will restart after firmware default values are restored. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS151 Message Completed System Erase Job ID: arg1 Arguments arg1 = job ID Detailed Description A System Erase job with the job ID identified in the message is completed. Recommended Response Action No response action is required.
Category Configuration (SYS = System Info) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS153 Message Deleting hardware cache data for controller: arg1 . Arguments arg1 = device name Detailed Description The non-volatile cache of the controller identified in the message is being erased.
Detailed Description Initiating secure erase operation on secure erase-capable drives for the controller identified in the message. Recommended Response Action No response action is required.
SYS156 Message Erase operations for System Erase tasks successfully completed. Detailed Description The requested component erase tasks of the System Erase operation is successfully completed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS158 Message Hardware cache erase is unsuccessful. Detailed Description Unable to erase hardware caches during the System Erase operation. Recommended Response Action Retry the System Erase operation with only the hardware cache erase option selected.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS160 Message The Lifecycle Controller logs are cleared. Detailed Description The Lifecycle Controller log data deleted as part of a System Erase operation. All previously stored information is no longer available. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS162 Message Turning on the server to perform System Erase tasks. Detailed Description The server will be turned on to enter UEFI System Services Manager (SSM). The storage-related erase operations selected, if any, will be processed by SSM. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS164 Message Access to Lifecycle Controller internal storage was not acquired. Detailed Description The System Erase operation attempted to access Lifecycle Controller internal storage that is already being accessed by another function.
Recommended Response Action Look at the Lifecycle Log for exception messages and resolve the issues described. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS166 Message The collection of OS and Application Data did not start within the allocated time. Detailed Description The collection of OS and Application Data did not start within the allocated time.
Recommended Response Action Wait for the job or System Services task in progress to complete before initiating a System Erase job. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS169 Message The iDRAC Service Module installed on the operating system is not up to date and does not support the Technical Support Report feature.
Recommended Response Action The SHA1v3Key and the MD5V3Key values must be entered together for an import operation. Category Configuration (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS172 Message A Remote Diagnostic operation has been interrupted. Detailed Description A Remote Diagnostic operation has been interrupted because the server was restarted during the operation.
Recommended Response Action Make sure the entered sharetype, sharename, IP address, username and password are valid and retry the operation. The network share connectivity can be tested by using the Test Network Connection feature of the iDRAC. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS175 Message Unable to find a device configuration for the FQDD entered.
Recommended Response Action Make sure that at least one storage controller is present in the server, and then retry the operation. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS179 Message Unable to export TTY log data because the storage controller present in the server does not support the feature.
Detailed Description The collect OS and Application Data operation cannot be completed because the OS Collector is not installed on the iDRAC. Recommended Response Action Install OS Collector on the iDRAC and retry the operation. To install the OS Collector using the iDRAC Web UI, get the latest OC Collector update package and then select the Update and Rollback link from the iDRAC Web UI home page and upload the install package.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC SYS183 Message Unable to allocate memory because of insufficient storage space in iDRAC. Detailed Description The memory cannot be allocated because of insufficient storage space in iDRAC. Recommended Response Action Reset iDRAC and then retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC SYS185 Message The Tech Support Report job has been cancelled. Detailed Description The Tech Support Report job that was running has been cancelled by user request.
Recommended Response Action Retry the operation after the server has finished starting and POST has completed. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS188 Message Unable to perform the import operation because the specified file on the remote share has a file size of zero, which is not valid.
Recommended Response Action Install supported operating system and then retry the operation. Category System Health (SYS = System Info) Severity Severity 2 (Warning) No alerts are applicable for this message SYS8500 Message Delay Auto-throttle sent to arg1 server(s). arg2 arg3 Arguments arg1 = number of servers, arg2 = error string, arg3 = errors Detailed Description The Chassis Management Controller (CMC) sent messages to delay power throttling to all capable servers in the chassis.
TMP Event Messages TMP0100 Message The system board arg1 temperature is less than the lower warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0102 Message The system board arg1 temperature is greater than the upper warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message System board temperature is outside of range.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC TMP0105 Message The system board arg1 temperature is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0107 Message The memory module arg1 temperature is less than the lower critical threshold. Arguments arg1 = number Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC TMP0110 Message The memory module arg1 temperature is outside of range. Arguments arg1 = number Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures.
Trap/EventID iDRAC 2163 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC TMP0112 Message The arg1 temperature is less than the lower warning threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
Recommended Response Action Check system operating environment. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message The temperature is outside of range.
TMP0115 Message The arg1 temperature is greater than the upper critical threshold. Arguments arg1 = name Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message The temperature is outside of range .
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* TMP0117 Message The arg1 temperature is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health (TMP = Temperature) Severity Severity 2 (Warning) Trap/EventID 2162 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* TMP0119 Message The system inlet temperature is less than the lower critical threshold. Detailed Description Ambient air temperature is too cool.
Detailed Description Ambient air temperature is too warm. Recommended Response Action Check system operating environment.
TMP0122 Message The system inlet temperature is outside of range. Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Inlet temperature is outside of range .
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* TMP0124 Message Disk drive bay temperature is less than the lower warning threshold. Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0126 Message Disk drive bay temperature is greater than the upper warning threshold. Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures.
Severity Severity 1 (Critical) Trap/EventID 2161 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0128 Message Disk drive bay temperature is outside of range. Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures.
Recommended Response Action No response action is required. Category System Health (TMP = Temperature) Severity Severity 3 (Informational) Trap/EventID 2163 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC TMP0130 Message The control panel temperature is less than the lower warning threshold.
TMP0131 Message The control panel temperature is less than the lower critical threshold. Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy TMP0133 Message The control panel temperature is greater than the upper critical threshold. Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy TMP0135 Message The control panel temperature is within range. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Insufficient system cooling detected. Check fans Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC TMP0137 Message The system cooling is working normally. Detailed Description The system cooling is working normally. Recommended Response Action No response action is required.
Detailed Description Disabling the C1E state in servers with processors that have their Thermal Design Power (TDP) value set to equal to or greater than 155 Watt results in increased fan speed during high CPU workloads. Recommended Response Action No response action is required.
TMP0201 Message CPU arg1 temperature is less than the lower critical threshold. Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message CPU temperature is outside of range.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC TMP0203 Message CPU arg1 temperature is greater than the upper critical threshold. Arguments arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment, fans, and heatsinks.
Recommended Response Action Check system operating environment, fans, and heatsinks. Category System Health (TMP = Temperature) Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message CPU temperature is outside of range.
TMP0300 Message The Enhanced Cooling Mode feature is enabled. Detailed Description The Enhanced Colling Mode feature is enabled. Recommended Response Action No response action is required. Category System Health (TMP = Temperature) Severity Severity 3 (Informational) No alerts are applicable for this message TMP0301 Message The Enhanced Cooling Mode feature is disabled. Detailed Description The Enhanced Colling Mode feature is disabled.
TMP1000 Message arg1 exceeded the maximum warning threshold. Arguments arg1 = tempsensor name Detailed Description The enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot. Recommended Response Action Check for factors that may cause overheating. For example, verify that the enclosure fan is working.
Trap/EventID 4210 OMSA Event ID 2101 OMSA Trap ID 105300 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* TMP1002 Message arg1 has exceeded the maximum failure threshold. Arguments arg1 = tempsensor name Detailed Description The enclosure is too hot. A variety of factors can cause the excessive temperature.
TMP1003 Message arg1 has crossed the minimum failure threshold. Arguments arg1 = tempsensor name Detailed Description The enclosure is too cold. Recommended Response Action Check whether the thermostat setting is too low and whether the room temperature is too cool.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* TMP5 Message The temperature probe maximum warning value was changed on arg1 . Arguments arg1 = Enclosure name Detailed Description You have changed the value for the maximum temperature probe warning threshold. This alert is provided for informational purposes.
Detailed Description A temperature sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC TMP502 Message The arg1 sensor has returned to a normal state with a value of arg2 degrees Celsius. Arguments arg1 = sensor name, arg2 = temperature Detailed Description The sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
temperature sensor (if applicable) such that it corresponds to the hardware configuration. Category System Health (TMP = Temperature) Severity Severity 2 (Warning) OMSA Event ID 5053 OMSA Trap ID 5053 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC TMP504 Message The arg1 sensor has detected an error with a value of arg2 degrees Celsius.
TMP505 Message The arg1 sensor has failed with a value of arg2 degrees Celsius. Arguments arg1 = sensor name, arg2 = temperature Detailed Description The temperature sensor identified in the message has failed. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log ✔* ✔ ✔* OS Log Power Off Power Cycle WS Eventing iDRAC CMC ✔ LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔* TMP7 Message arg1 has failed. Arguments arg1 = Temp Sensor Name Detailed Description A device has been failed and the system is no longer functioning in optimal condition. Recommended Response Action Replace the device.
Recommended Response Action Check the chassis event log for fan issues and fix any issues present. If no fan issues are detected, check chassis ambient temperature and make sure the temperature is within operating range. Utilize the RACADM command "racadm getsensorinfo" to check the chassis ambient temperature.
Detailed Description The system has recovered from being unable to read planar board or control panel temperature sensors. Recommended Response Action No response action required.
TMPS Event Messages TMPS0100 Message Inlet temperature is above warning level for extended duration. Detailed Description Inlet temperature has been above the warning threshold for duration of 8% or more for the operational time during the last one year. Recommended Response Action This condition will occur if the ambient temperature is high. Make sure the ambient temperature of the environment is in normal range.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔ CMC TMPS0102 Message Inlet temperature is above warning level for extended duration. Detailed Description Inlet temperature has been above the warning threshold for duration of 10% or more for the operational time during the last one year.
Severity Severity 1 (Critical) Trap/EventID 2521 Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle CMC LC Log iDRAC ✔* LCD Reset Chassis Event Proxy ✔ CMC 2077
TST Event Messages TST100 Message The operation was successful. Detailed Description The operation completed successfully. Recommended Response Action No response action is required. Category Configuration (TST = Test Alert) Severity Severity 3 (Informational) No alerts are applicable for this message TST101 Message Resource allocation failure. Detailed Description The operation did not complete successfully because of lack of memory or file space in the iDRAC firmware.
TST103 Message Missing parameters arg1 Arguments arg1 = parameter names Detailed Description One or more required parameters needed for the operation are missing. Recommended Response Action To provide the correct parameters, see Lifecycle Controller-Remote Services documentation. Category Configuration (TST = Test Alert) Severity Severity 2 (Warning) No alerts are applicable for this message TST104 Message SNMP traps not configured.
TST106 Message Email alert destination address not configured. Detailed Description The email alert being tested is not properly configured. Recommended Response Action Configure the email alert and retry the operation. If the failure persists, reset iDRAC.
UEFI Event Messages UEFI0000 Message CPU Exception Type 0x00: Divide by Zero (Software). Detailed Description A CPU type 0x00, divide by zero exception, (type 0x00) occurred in the pre-boot UEFI environment. The software attempted to do a mathematical divide by zero, an illegal operation. Recommended Response Action Recently installed hardware or updated software may cause this exception.Update or remove the hardware or software.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0004 Message CPU Exception Type 0x06: Invalid Opcode (Software). Detailed Description A CPU invalid opcode exception (type 0x06) occurred in the pre-boot UEFI environment. The software attempted to execute invalid code. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0006 Message CPU Exception Type 0x08: Double Fault (Software). Detailed Description A CPU double fault exception (type 0x08) occurred. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0008 Message CPU Exception Type 0x0A: Invalid Task Segment State Segment (TSS) (Software). Detailed Description A CPU invalid task segment state (TSS) exception (type 0x0A) occurred in the preboot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0010 Message CPU Exception Type 0x0C: Stack-Segment Fault (Software). Detailed Description A CPU stack-segment fault (type 0x0C) exception occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0012 Message CPU Exception Type 0x0E: Page Fault (Software). Detailed Description A CPU page fault (type 0x0E) exception occurred in the pre-boot UEFI environment. A program accessed a page mapped in the virtual address space, but not loaded in physical memory. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0014 Message CPU Exception Type 0x11: Alignment Check (Software). Detailed Description A CPU alignment check exception (type 0x11) occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0016 Message Lifecycle Controller (LC) firmware was not accessible and is therefore in Recovery mode. Detailed Description Unable to find a Lifecycle Controller partition.
Detailed Description Unable to locate a file required to run Lifecycle Controller. No Lifecycle Controller functionality is available while in Recovery Mode. Recommended Response Action Repair Lifecycle Controller firmware using the Lifecycle Controller Dell Update Package (DUP) or Lifecycle Controller Repair Package via iDRAC. For more information, see Lifecycle Controller Users Guide.
UEFI0019 Message Lifecycle Controller (LC) is unable to complete a requested task or function and prevented the boot process from completing on multiple attempts. LC is in Recovery Mode. Detailed Description The system boot process did not complete repeatedly due to problems encountered while performing a Lifecycle Controller task for function. No Lifecycle Controller functionality is available while in Recovery Mode.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0021 Message The Lifecycle Controller feature is disabled. Detailed Description The Lifecycle Controller feature is disabled. The feature was disabled because of one of the following conditions: 1) The feature was disabled manually using the F2 System Setup utility or through an iDRAC interface, 2) BIOS encountered an issue starting the feature and automatically disabled it.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0023 Message BIOS is unable to send the End of POST message to Management Engine because the Management Engine is not responding. Detailed Description The End of POST message could not be sent to the Management Engine because the Management Engine is not responding.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0025 Message Unable to initialize Management Engine firmware. Detailed Description The Management Engine firmware cannot be initialized. The BIOS will reset the system to retry the initialization process.
Category System Health (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0027 Message The system must be restarted for the new license to become effective. Detailed Description A license change for the system or a component in the system requires a system reset in order for the new license to take effect.
Recommended Response Action Remove input power from the system, wait for 30 seconds, and re-apply input power. Turn on the system. Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0029 Message Unable to initialize iDRAC because of some critical issues.
UEFI0030 Message A keyboard device is not connected to the system. Detailed Description A keyboard device is not connected to the system. Recommended Response Action Connect a keyboard device to the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0032 Message Unable to initialize the TPM chip because the TPM chip is not functioning. Detailed Description The TPM chip cannot be initialized because the TPM chip is not functioning. Recommended Response Action Remove input power from the system, wait for 30 seconds, and re-apply input power. Turn on the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0034 Message A CMOS battery loss is detected resulting in an invalid BIOS configuration. Detailed Description A CMOS battery loss is detected resulting in an invalid BIOS configuration. Recommended Response Action Go to the System Setup to configure system settings, system time and date.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0036 Message Unable to initialize the iDRAC Shared Memory Architecture (SMA) interface. Detailed Description The iDRAC Shared Memory Architecture (SMA) interface cannot be initialized. The BIOS will use the Keyboard Controller Style (KCS) interface.
Recommended Response Action Do one of the following: 1) Remove input power from the system, wait for 30 seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC firmware on the system.
UEFI0039 Message Unable to communicate with iDRAC because of an issue in the iDRAC Keyboard Controller Style (KCS) Intelligent Platform Management Interface (IPMI). Detailed Description Unable to communicate with iDRAC because of an issue in the iDRAC Keyboard Controller Style (KCS) Intelligent Platform Management Interface (IPMI).
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0041 Message Unable to enable the TXT feature because the Virtualization Technology (VT) feature is not enabled on the processor. Detailed Description Unable to turn on the TXT feature because the Virtualization Technology (VT) feature is not enabled on the processor.
Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0043 Message Unable to enable the TXT feature because the processor does not support TXT. Detailed Description Unable to enable the TXT feature because the processor does not support TXT.
Recommended Response Action Contact your service provider. Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0045 Message Unable to enable the TXT feature because a TPM chip is not present. Detailed Description Unable to enable the TXT feature because a TPM chip is not present.
Detailed Description An issue in observed in the previous invocation of TXT SINIT Authenticated Code Module (ACM) because the TXT information stored in the TPM chip may be corrupted. Recommended Response Action Do one of the following: 1) Update the BIOS firmware. 2) Go to System Setup > System Security page, click the "Clear" option under TPM command. Restart the system, go to System Setup > System Security page, click the "Activate" option under TPM command, and then enable TXT.
UEFI0048 Message The Collect System Inventory on Restart (CSIOR) operation is not performed during this restart because Lifecycle Controller is not functioning. Detailed Description The Collect System Inventory on Restart (CSIOR) operaiton is not performed during this restart because Lifecycle Controller firmware could not be accessed or run properly. Recommended Response Action Repair Lifecycle Controller using the Update Package. For more information, see the Lifecycle Controller Users Guide.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0050 Message The process of collecting Brand information is started. Detailed Description The rebranding process is started. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0052 Message Unable to complete the rebranding operation because of the issue(s) displayed earlier. Detailed Description The rebranding process cannot be completed because of the reasons identified on the computer screen. Recommended Response Action Do one of the following and retry the operation: 1) Update the iDRAC firmware. 2) Update the system BIOS. 3) Update the OEM ID module.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0054 Message Debranding process is completed. The system is being restarted. Detailed Description Debranding process is completed. The system is being restarted. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0056 Message A PCIe error has occurred. Detailed Description The PCIe error is logged during Power-on-Self-Test (POST). The error could have occurred during either the current or the previous POST.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0058 Message An uncorrectable Memory Error has occurred because a Dual Inline Memory Module (DIMM) is not functioning.
Recommended Response Action Check the PSU types and make sure they are appropriately matched, and then retry the operation. For more information, see the platform Owners Manual.
Detailed Description The request to change one or more attribute(s) is being processed. Recommended Response Action No response action is required. Category Updates (UEFI = UEFI Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0062 Message One or more attributes are successfully changed.
UEFI0063 Message Unable to change an attribute because of issues in the Attribute Configuration Interface (ACI) data block. Detailed Description An attribute cannot be successfully configured because of an issue in the ACI data block. Recommended Response Action Check the ACI data block for any invalid configuration dtata and settings, and then retry the operation. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0065 Message One or more attributes are successfully configured. The system will be automatically turned off in 5 seconds. Detailed Description One or more attributes are successfully configured. The system is automatically turned off in 5 seconds. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0067 Message A PCIe link training failure is observed in arg1 and device link is disabled. Arguments arg1 = PCIe device Detailed Description A PCIe link failure is observed in the PCIe device identified in the message and device link is disabled.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0069 Message A CMOS checksum error has occurred. CMOS is reinitialized. Detailed Description A CMOS checksum error has occurred resulting in an invalid BIOS configuration. BIOS configuraiton is reset to detault settings.
Recommended Response Action Check the System Event Log (SEL) to identify the PCIe device, and then update its firmware. Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0071 Message One or more UEFI network interfaces is not available. The corresponding UEFI network devices are disabled.
Arguments arg1 = device name Detailed Description When the Secure Boot feature is enabled, the system BIOS authenticates each UEFI driver against the Secure Boot policy. If a UEFI driver does not meet the policy criteria, the system BIOS does not load or execute the UEFI driver and displays this message at the end of POST. The Secure Boot policy consists of authorized and unauthorized X.509 certificates; signed drivers must chain to an authorized certificate.
Signature Database. 2) If the boot option is not authorized but it can be trusted, enter System Setup > System BIOS > Security Settings page, set Secure Boot Policy to Custom, and add a entry for the boot option in the Authorized Signature Database (System Setup > System BIOS > Security Settings > Custom Policy Settings > Authorized Signature Database > Import Database Entry).
UEFI0075 Message Network Daughter Card 1 is not detected. Detailed Description The Network Daughter Card 1 is not detected. Recommended Response Action Install a Network Daughter Card in the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0077 Message One or more PCIe device errors occurred in the previous boot. Detailed Description One or more PCIe device errors occured in the previous boot. Recommended Response Action Check the System Event Log (SEL) to identify the PCIe device with errors, and then update its firmware.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0079 Message One or more Uncorrectable Memory errors occurred in the previous boot. Detailed Description One or more Uncorrectable Memory errors occurred in the previous boot. Recommended Response Action Check the System Event Log (SEL) to identify the non-functional DIMM, and then replace the DIMM.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0081 Message Memory size has changed from the last time the system was started. Detailed Description Memory size has changed from the last time the system was started. No action is required if memory was added or removed. Recommended Response Action If the change is expected, no action is necessary.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0083 Message One or more PCI System errors (SERR) have occurred. Detailed Description One or more PCI System errors (SERR) have occurred. Recommended Response Action Check the System Event Log (SEL) to identify the PCI device that caused the SERR. Update the identifed device firmware.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0085 Message One or more chipset errors have occurred. Detailed Description One or more chipset errors have occurred. Recommended Response Action Check the System Event Log (SEL) to identify the chipset error. Do one of the following: 1) Turn off the input power to the system and turn on again.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0087 Message Unsupported 4Gb technology DIMM module is installed on memory slot: arg1 . Arguments arg1 = slot number Detailed Description Unsupported 4Gb technology DIMM module is installed on the memory slot indentified in the message.
Recommended Response Action Remove the unsupported DIMM module from the identified memory slot and replace it with a supported module. For more information, see the platform Owners Manual.
Arguments arg1 = slot number Detailed Description A DIMM with an incompatible number of ranks is installed on the memory slot identified in the message. Recommended Response Action Remove the unsupported DIMM module from the identified memory slot and replace it with a supported module. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0092 Message The number of DIMM ranks has exceeded the maximum allowed ranks per channel limit. Detailed Description The number of DIMM ranks has exceeded the maximum allowed ranks per channel limit. Recommended Response Action Check the total number of ranks in each channel to make sure it does not exceed the maximum allowed limit. For more information, see the platform Owners Manual.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0094 Message Unsupported Non-ECC memory module is installed on memory slot: arg1 . Arguments arg1 = slot number Detailed Description Unsupported Non-ECC memory module is installed on the memory slot identified in the message. Recommended Response Action Remove all Non-ECC DIMMs and replace them with ECC DIMMs.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0096 Message Unable to enable the Advanced ECC memory operating mode because the current DIMM population or system configuration does not support Advanced ECC mode.
Recommended Response Action Make sure identical memory modules in corresponding slots of channel pairs are populated. For more information, see the platform Owners Manual.
UEFI0099 Message Unable to enable the Memory Mirroring feature because the current DIMM population or hardware configuration does not support the feature. Detailed Description The Memory Mirroring feature cannot be enabled because the current DIMM population or hardware configuration does not support the feature. Recommended Response Action Check the DIMM population and hardware configuration to make sure the Memory Mirroring feature can be supported. For more information, see platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0101 Message Total amount of installed memory has exceeded limit. Detailed Description The total amount of installed memory has exceeded the amount supported by the platform. Recommended Response Action Remove memory modules from the system to reduce the total amount of installed memory. For more information on installed memory limit, see the platform Owners Manual.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0103 Message One or more memory initialization errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory initialization error have occurred on the memory slot identified in the message.
Recommended Response Action Install DIMM modules in sequential order without skipping any slots in the channel. For more information, see the platform Owners Manual.
Arguments arg1 = slot Detailed Description One or more memory correctable training errors have occurred on the memory slot identified in the message. Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system. If the correctable error persists, then replace the faulty memory module identified in the message.
UEFI0108 Message One or more memory errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error occured during Read Receiving Enable initialization. Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system. If the issues persist, then replace the faulty memory module identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0110 Message One or more memory errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error occurred during Write DQ/DQS initialization. Recommended Response Action Remove input power to the system, reseat the DIMM module and restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0112 Message One or more memory errors have occurred on memory slot: arg1 . Arguments arg1 = slot Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error occurred during the LRDIMM interface initialization.
Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0114 Message Unable to enable the Fault Resilient Memory (FRM) operating mode because of mismatches in DIMM channel configurations.
Recommended Response Action The Management Engine is functioning normally now. No response action is required. Category System Health (UEFI = UEFI Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0116 Message One or more boot drivers have reported issue(s).
Detailed Description Card identification signature is not present on Internal Dual Secure Digital Module (IDSDM) SD card 1. Recommended Response Action Do one of the following: 1) Check the IDSDM or the SD card media. 2) Try reseat or replace the SD card media. If the issue persists, contact your service provider.
UEFI0119 Message The Internal Dual Secure Digital Module (IDSDM) RAID redundancy was lost. Detailed Description Internal Dual Secure Digital Module (IDSDM) RAID redundancy was lost. The system BIOS should have prompted the user for the rebuild process. Recommended Response Action No additional response action is required if you have followed the instructions on the screen to start the rebuild process.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0121 Message The primary SD card is missing, not responding, or in write-protected mode. Detailed Description The primary SD card is missing, not responding, or in write-protected mode. Recommended Response Action Do one of the following: 1) Install a SD card media in the primary SD card slot. 2) Reseat or replace the SD card media. 3) If write-protected mode is expected, then no response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC UEFI0123 Message The secondary SD card has now become the primary SD card. Detailed Description The secondary SD card has now become the primary SD card. Recommended Response Action Check the screen display or the Lifecycle Log for prior messages. If the switch is expected, then no response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0125 Message Unable to finish The Internal Dual Secure Digital Module (IDSDM) image rebuild process because of issues. Detailed Description Unable to finish The Internal Dual Secure Digital Module (IDSDM) image rebuild process because of issues.
Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0127 Message The secondary SD card is in write-protected mode. Detailed Description The secondary SD card is write-protected mode. Recommended Response Action No response action is required if this is intentional.
Category Configuration (UEFI = UEFI Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0129 Message The Internal Dual Secure Digital Module (IDSDM) has encountered an unknown issue. Detailed Description The Internal Dual Secure Digital Module (IDSDM) has encountered an unknown issue.
Recommended Response Action Go to the System Setup to set the current time and date. Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC UEFI0131 Message Unable to load one or more option ROMs because of insufficient shadow memory.
Detailed Description Unable to load one or more option ROMs because of insufficient base memory. The base memory is memory below 640K. Recommended Response Action Do one of the following: 1) Remove unused PCIe card(s) to free up option ROM space. 2) Disable unused boot protocol instances (such as PXE, iSCSI, etc.) from applicable PCIe card(s) option ROM configurations. 3) If possible, install and run the Operating System in UEFI boot mode.
UEFI0134 Message Unable to allocate Memory Mapped Input Output (MMIO) resources for one or more PCIe devices because of insufficient MMIO memory. Detailed Description Unable to allocate Memory Mapped Input Output (MMIO) resources for one or more PCIe devices because of insufficient MMIO memory. Recommended Response Action Do one of the following: 1) Remove unused PCIe card(s) to free up MMIO space. 2) Go to System Setup and enable the Memory Mapped I/O above 4GB option.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0136 Message Unable to execute CSIOR (Collect System Inventory on Restart) because the Lifecycle Controller (LC) firmware was not accessible. Detailed Description The CSIOR (Collect System Inventory on Restart) operation cannot be executed because the Lifecycle Controller (LC) firmware was not accessible. This issue is caused by missing LC partitions.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0138 Message Unable to execute CSIOR (Collect System Inventory on Restart) because the Lifecycle Controller (LC) firmware was unable to complete a requested task or function.
Recommended Response Action Do one of the following: 1) Restart the system and retry the operation. 2) Update the iDRAC firmware. If the issue persists, contact your service provider.
Detailed Description The System Service Mode (SSM) cannot be entered because the Lifecycle Controller (LC) firmware was not accessible. This situation is caused by missing LC files. Recommended Response Action Do one of the following: 1) Restart the system and retry the operation. 2) Update the iDRAC firmware. If the issue persists, contact your service provider.
UEFI0143 Message Unsupported processor(s) are installed. Detailed Description Unsupported processor(s) are installed. Recommended Response Action Replace the processor(s) with supported ones. For more information about supported processors, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0145 Message The Trusted Platform Module (TPM) installed on this system is not supported. Detailed Description The Trusted Platform Module (TPM) installed on this system is not supported. Recommended Response Action Do one of the following: 1) Update the BIOS firmware. 2) Replace the TPM with a supported one. If the issue persists, contact your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0147 Message The system hardware or cabling configuration is invalid. Detailed Description The system hardware or cabling configuration is invalid. Recommended Response Action Do the following: 1) Make sure the system cables, risers, and CPU configuration are installed correctly.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0149 Message The PERC storage adapter in arg1 is not supported by the installed storage backplane.
Detailed Description The system has detected a storage backplane that is not supported in this system or configuration. The backplanes functionality may be degraded or disabled. Recommended Response Action Install a supported backplane configuration. For more information, see the platform Owners Manual.
UEFI0152 Message This BIOS is for testing purpose only. Detailed Description This is a test BIOS and must not be used in production environment. Recommended Response Action Do not use this BIOS in production.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0154 Message Unable to find the Dell Processor Acceleration Technology (DPAT) Enterprise license after three consecutive boots. The Dell Controlled Turbo BIOS setup configuration is being reverted to default because of the absent license. Detailed Description Unable to find the Dell Processor Acceleration Technology (DPAT) Enterprise license after three consecutive boots.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0156 Message Unable to find the Dell Processor Acceleration Technology (DPAT) Enterprise license in three consecutive boots.
UEFI0157 Message The iDRAC request to reset BIOS to default settings is successfully completed. Detailed Description The request to reset BIOS to default settings is successfully completed. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0159 Message Unsupported Unregistered Dual In-line Memory Module (UDIMM) memory is installed on memory slot: arg1 Arguments arg1 = slot number Detailed Description Unsupported 4Gb technology DIMM module is installed on the memory slot identified in the message. Recommended Response Action Remove the unsupported DIMM module from the identified memory slot and replace it with a supported module.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0161 Message An unsupported DIMM population has been detected on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An unsupported DIMM population has been detected on memory slots identified by this message. Recommended Response Action Remove all unsupported DIMM modules from the system.
Category Configuration (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0163 Message Unsupported DIMM module with less than 2Gb technology is installed on memory slot: arg1 .
Detailed Description The Advanced ECC memory operating mode cannot be enabled because of mismatches in the DIMM channel configurations. Recommended Response Action Make sure identical memory modules in corresponding slots of channel pairs are populated. For more information, see the platform Owners Manual.
UEFI0166 Message Unable to configure memory interleaving on DIMM modules on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description Memory could not be interleaved because the number of allowable Target Address Decode (TAD) rules exceeded during memory initialization. Recommended Response Action Check the DIMM population and hardware configuration to make sure interleaving can be supported. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0168 Message Unable to configure memory interleaving on DIMM modules on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description Memory could not be interleaved because a negative Target Address Decode (TAD) offset was calculated during memory initialization. Recommended Response Action Check the DIMM population and hardware configuration to make sure interleaving can be supported.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0170 Message Unable to configure memory interleaving on DIMM modules on memory slots: arg1 .
Recommended Response Action Dual Rank DIMM modules must be installed before Single Rank DIMM modules on the channel. Populate memory modules in a supported configuration. For more information, see the platform Owners Manual.
UEFI0173 Message A Quad Rank DIMM module is installed on memory slot arg1 after a Dual Rank DIMM module. Arguments arg1 = slot number Detailed Description A memory population violation has been detected on the identified DIMM slot. Recommended Response Action Quad Rank DIMM modules must be installed before Dual Rank DIMM modules on the channel. Populate memory modules in a supported configuration. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0175 Message A Octal Rank DIMM module is installed on memory slot arg1 after a Quad Rank DIMM module. Arguments arg1 = slot number Detailed Description A memory population violation has been detected on the identified DIMM slot. Recommended Response Action Quad Rank and Octal Rank DIMM modules cannot be mixed on a channel. Populate memory modules in a supported configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0177 Message A DIMM module is installed on memory slot arg1 after a Quad Rank DIMM module. Arguments arg1 = slot number Detailed Description A memory population violation has been detected on the identified DIMM slot. Recommended Response Action Only a single Quad Rank DIMM module can be installed on a channel.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the correctable error persists, then replace the faulty memory module identified in the message.
UEFI0180 Message One or more memory correctable training errors have occurred on memory slot: arg1 . Arguments arg1 = slot number Detailed Description One or more memory correctable training errors have occurred on the memory slot identified in the message. A corrected Write Leveling error was detected. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0182 Message One or more memory correctable training errors have occurred on memory slot: arg1 . Arguments arg1 = slot number Detailed Description One or more memory correctable training errors have occurred on the memory slot identified in the message. A corrected Early Vref Centering error was detected.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0184 Message One or more memory errors have occurred on memory slot: arg1 . Arguments arg1 = slot number Detailed Description One or more memory errors have occurred on memory slot identified in the message. The error occurred during Load Reduced DIMM (LR-DIMM) buffer initialization.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
UEFI0187 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Clock Detection phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0189 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Transmit DQS DCC phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0191 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the VCK Reference Clock phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
UEFI0194 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Fine Command Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0196 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Error Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0198 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Read Level Fine Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module identified in the message.
UEFI0201 Message An error occurred during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Scalable Memory Interconnect initialization during the Write Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0203 Message A failing memory buffer has been detected during Scalable Memory Interconnect (SMI) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description A failing memory buffer has been identified on the memory riser identified in the message. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0205 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Command Clock Training - Group 0 phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0208 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Command Clock Training - Group All phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0210 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Receive Buffer Vref Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0212 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Early Command Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0215 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Basic Write Level Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0217 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Basic Write DQ/DQS Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0219 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Read Timing Centering 2D Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0222 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Round Trip Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0224 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Transmit Buffer Per Bit Deskew Training phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0226 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the DDR4 LR-DIMM Transmit Buffer Training phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0229 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Memory Buffer Receive Enable Training - Calibration phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0231 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Memory Buffer Write Leveling Training - Configuration Read phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0233 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Memory Buffer Write Leveling Training - FIFO Reset phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
UEFI0236 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Write DQ/DQS Training - FIFO Reset phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system. If the issue persists, then replace the faulty memory module(s) identified in the message.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0238 Message An error occurred during DDR memory channel initialization on memory slots: arg1 . Arguments arg1 = slot numbers Detailed Description An error occurred during DDR memory initialization during the Write DQ/DQS Training - Calibration phase. Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the DIMM module and 3) Restart the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0240 Message An error occurred during Voltage Regulator (VR) initialization on memory riser arg1 . Arguments arg1 = riser letter Detailed Description An error occurred during Memory Voltage Regulator initialization during the VR0 SVID Ramp phase.
Recommended Response Action Do the following: 1) Remove input power to the system, 2) Reseat the memory riser and 3) Restart the system. For more information, see the platform Owners Manual.
UEFI0243 Message Scalable Memory Interconnect (SMI) operating at reduced width on memory riser arg1 . Arguments arg1 = riser letter Detailed Description The Scalable Memory Interconnect (SMI) channel identified in the message is operating at a degraded width. This allows continued uptime although indicates an error condition requiring further investigation.This maybe an early indication of upcoming memory riser failure.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0245 Message Quick Path Interconnect (QPI) link initialization error detected. Detailed Description Quick Path Interconnect (QPI) initialization failed to configure all installed processors to the maximum common frequency. Recommended Response Action Reseat all processors in the system and ensure all processors are matching. If the issue persists, contact your service provider.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0247 Message Quick Path Interconnect (QPI) initialization error detected. Detailed Description Quick Path Interconnect (QPI) initialization encountered a programmatic error. The requested Memory Mapped IO (MMIOH) size is not supported. MMIOH allocation was forced instead. Recommended Response Action Reseat all processors in the system and ensure all processors are matching.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0249 Message Quick Path Interconnect (QPI) initialization error detected. Detailed Description Quick Path Interconnect (QPI) initialization encountered a programmatic error. A requested resource could not be allocated. Resource was forced to maximum possible value instead.
Category System Health (UEFI = UEFI Event) Severity Severity 1 (Critical) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0251 Message Memory riser arg1 is populated behind an empty processor socket. Arguments arg1 = riser number Detailed Description A memory riser was detected behind an empty processor socket.
Detailed Description The watchdog timer is armed before the BIOS boot manager invokes an UEFI boot option. The watchdog is set to a period of 5 minutes. The Operating System boot loader from the boot option is required to disable the watchdog timer after it is successfully loaded, otherwise the system will reset if the timer expires. Recommended Response Action Check the boot option image and boot loader. Update them to the latest version if possible.
UEFI0254 Message Unable to enable NUMA Fault Resilient Memory operating mode because of channel configuration mismatches. Detailed Description Unable to enable NUMA Fault Resilient Memory operating mode because of channel configuration mismatches. Recommended Response Action Make sure identical memory modules in corresponding slots of channel pairs are populated. For more information, see platform Owners Manual.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC UEFI0256 Message Unable to allocate legacy I/O resources for one of more PCIe devices because the legacy I/O space limit was reached. Detailed Description Unable to allocate legacy I/O resources for one of more PCIe devices because the legacy I/O space limit was reached. The legacy I/O space limit is 64K.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔ CMC UEFI0258 Message An issue is observed on the Hard-drive/SSD backplane. Detailed Description An issue is observed on the Hard-drive/SSD backplane. Recommended Response Action Do one of the following: 1) Make sure the correct type of Hard-drive/SSD backplane is installed.
Recommended Response Action Check the network cable connection of the system and retry the operation. Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) No alerts are applicable for this message UEFI0264 Message Unable to perform iSCSI boot because the iSCSI initiator name is invalid. Detailed Description Unable to perform iSCSI boot because the iSCSI initiator name is invalid.
Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the iSCSI initiator IPv4 subnet mask address is invalid. Recommended Response Action Go to System Setup > Network Settings > iSCSI Device Settings page, make sure there is no typographical error in the Initiator Subnet Mask field, and retry the operation.
UEFI0269 Message Unable to perform iSCSI boot on connection arg1 because the iSCSI target IP address is invalid. Arguments arg1 = number Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the iSCSI target IP address is invalid. Recommended Response Action Go to System Setup > Network Settings > iSCSI Device Settings > Connection Settings page, do the following: 1) Make sure the Target IP Address is set correspoding to the mode enabled (IPv4/IPv6).
Category Configuration (UEFI = UEFI Event) Severity Severity 2 (Warning) No alerts are applicable for this message UEFI0272 Message Unable to perform iSCSI boot on connection arg1 because the BIOS cannot obtain the initiator information from DHCPv4 server. Arguments arg1 = number Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the BIOS cannot obtain the initiator information from DHCPv4 server.
Detailed Description Unable to perform iSCSI boot on the connection identified in the message because the iSCSI login operation did not complete successfully. Recommended Response Action Do the following: 1) Go to System Setup > Network Settings > iSCSI Device Settings > Connection Settings page, make sure the target name is correct. 2) On the iSCSI target system, make sure the initiator name is added into the target identifiers.
Severity Severity 2 (Warning) No alerts are applicable for this message UEFI0277 Message Unable to perform iSCSI boot on connection arg1 because the iSCSI target configuration data obtained from DHCPv6 server is invalid. Arguments arg1 = number Detailed Description Unable to perform iSCSI boot on the connection number identified in the message because the iSCSI target configuration data obtained from DHCPv6 server is invalid.
USR Event Messages USR0001 Message arg1 Arguments arg1 = message Detailed Description No detailed description is required. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0005 Message Login failed from arg1 : arg2 Arguments arg1 = username, arg2 = ip_address Detailed Description Login failed from UserID: IP Address Recommended Response Action Contact the iDRAC administrator and ensure the username and password credentials used are correct.
Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert Remote System Log LCD OS Log Power Off Power Cycle WS Eventing ✔ CMC LC Log iDRAC Reset Chassis Event Proxy ✔* CMC USR0008 Message The Default Login Warning feature is disabled. Detailed Description The Default Login Warning feature is disabled. No warning is provided if any local user is configured with default credentials, Recommended Response Action No response action is required.
No alerts are applicable for this message USR0014 Message The current user session is invalid. Detailed Description The user session which is currently in use is invalid. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) No alerts are applicable for this message USR0015 Message The specified user does not exist. Detailed Description The specified user does not exist.
USR0017 Message No active sessions currently exist for the specified user. Detailed Description There are no active sessions on the iDRAC for the specified user. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) No alerts are applicable for this message USR0018 Message No active sessions currently exist. Detailed Description There are no active sessions on the iDRAC which can be displayed.
USR0020 Message Invalid Session ID. Detailed Description The specified session id does not exist and is invalid. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 2 (Warning) No alerts are applicable for this message USR0021 Message Unable to close session with the specified ID Detailed Description The session could not be closed. A possible reason is that the session does not exist.
USR0023 Message The current user privilege is not valid. Detailed Description The user privilege is invalid. This may be due to invalid combinations of privileges given to the user. Recommended Response Action Request the administrator to assign appropriate user privileges to the specific user. Category Audit (USR = User Tracking) Severity Severity 2 (Warning) No alerts are applicable for this message USR0030 Message Successfully logged in using arg1 , from arg2 and arg3 .
Detailed Description Unsuccessful login for the username, IP address, and interface identified in the message. Recommended Response Action Make sure the login credentials are valid and retry the operation.
USR0033 Message Login for arg1 from arg2 using arg3 was incomplete. Arguments arg1 = username, arg2 = IP address, arg3 = interface name Detailed Description The IPMI over LAN login attempt was ended by the IPMI client before success or failure. Recommended Response Action No response action is required.
Filter Visibility iDRAC IPMI Alert ✔ SNMP Alert Email Alert Remote System Log WS Eventing ✔* ✔* ✔* ✔* OS Log Power Off Power Cycle CMC LC Log iDRAC LCD ✔* Reset Chassis Event Proxy ✔* CMC USR0150 Message Opening a remote VNC session from IP address arg1 . Arguments arg1 = IP address Detailed Description The VNC client is connected from the IP address identified in the message to the iDRAC VNC Server. Recommended Response Action No response action is required.
Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0152 Message Unable to connect the remote VNC session, beacause an incorrect VNC password was entered from the IP arg1 .
Detailed Description The VNC client is logged off from the IP address identified in the message. Recommended Response Action To re-establish the remote VNC session, log in again using the VNC client.
USR0171 Message The Front Panel USB port is detached from the iDRAC Disk.USBFront. arg1 . Device Details: Device Class arg2 , Vendor ID arg3 , Product ID arg4 . Arguments arg1 = port number, arg2 = class, arg3 = vendor ID, arg4 = product ID Detailed Description The device identified in the message is connected to the Front Panel USB port and detached from the iDRAC. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0173 Message The Front Panel USB port switched automatically from iDRAC to operating system. Detailed Description The Front Panel USB port switched automatically from iDRAC to operating system. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0175 Message The Front Panel USB Port Over Current is detected for the attached device on Disk.USBFront. arg1 . Arguments arg1 = port number Detailed Description The USB device attached to the port identified in the message is drawing more current than is supported by the port. Recommended Response Action Reinsert the USB device in the Front Panel USB Port and retry the operation.
Severity Severity 3 (Informational) Filter Visibility iDRAC IPMI Alert SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0177 Message Configuring the Front Panel USB Port Mode to Automatic because the iDRAC is unable to retrieve the Front Panel USB Port Mode.
Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0181 Message The Quick Sync feature is deactivated because the inactivity timeout limit was reached.
Detailed Description Server information has been accessed by using the iDRAC Quick Sync feature. Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR0183 Message A bezel with the iDRAC Quick Sync feature is detected.
USR0184 Message A bezel with the iDRAC Quick Sync feature has been disconnected and the feature is not available. Detailed Description A bezel with the iDRAC Quick Sync feature has been disconnected and the feature is not available. Recommended Response Action Connect a bezel wth the iDRAC Quick Sync feature. Press the activate button to enable the Quick Sync feature.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC USR100 Message The command was successful. Detailed Description The operation completed successfully. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) No alerts are applicable for this message USR103 Message Missing parameters arg1 . Arguments arg1 = parameter names Detailed Description One or more required parameters needed for the operation are missing. Recommended Response Action Refer to the Lifecycle Controller Remote Services documentation and provide the required parameters.
No alerts are applicable for this message USR106 Message arg1 unauthorized for arg2 on arg3 . arg4 Arguments arg1 = username, arg2 = operation, arg3 = classname, arg4 = methodname Detailed Description The username provided does not have sufficient privileges to perform the invoke operation on the method. Recommended Response Action Retry the operation using user credentials that are authorized to perform the operation.
Category Audit (USR = User Tracking) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔ CMC ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* USR8501 Message Successfully closed Session process: pid= arg1 sid= arg2 Arguments arg1 = process ID, arg2 = session ID Detailed Description The operation to close a user session using the process ID identified in the message was
Recommended Response Action No response action is required. Category Audit (USR = User Tracking) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔ CMC ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* USR8503 Message Domain user authentication was not successful.
Detailed Description The IP range filter feature is enabled in CMC. The IP address from where the login attempt was made is not in the specified range of IP address that can access the CMC. Recommended Response Action If access needs to be given to this specified IP address, change the IP range address and IP range mask accordingly and retry the operation.
USR8506 Message Successfully closed Session: sid= arg1 Arguments arg1 = session ID Detailed Description The operation to invalidate the Session identified in the message was successful. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* USR8508 Message arg1 login was not successful (username= arg2 , ip= arg3 , reason= arg4 ) Arguments arg1 = Session type, arg2 = user name, arg3 = ip address, arg4 = failure reason Detailed Description The login attempt with details specified in the message was not successful. Recommended Response Action Contact the administrator and ensure the username and password credentials used are correct.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log iDRAC ✔ ✔ CMC ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset WS Eventing Chassis Event Proxy ✔* USR8510 Message Login was successful arg1 (username= arg2 , type= arg3 , sid= arg4 ) Arguments arg1 = description, arg2 = username, arg3 = session type, arg4 = session ID Detailed Description Successful login by Username identified in the message.
Recommended Response Action No response action is required.
Arguments arg1 = username, arg2 = IP address, arg3 = session type Detailed Description Successful login from IP address identified in the message by username identified in the message. Recommended Response Action No response action is required.
VDR Event Messages VDR1 Message arg1 failed. Arguments arg1 = VD Name Detailed Description A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency. Recommended Response Action Replace the failed component. You can identify which component has failed by locating the component that has a red "X" for its status.
OMSA Trap ID Filter Visibility 120100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ VDR100 Message arg1 is unavailable because of incompatibilities with the current controller. Arguments arg1 = virtual disk Detailed Description The virtual disk identified in message cannot be used because of missing features on the current controller.
VDR101 Message Hot Spare Protection policy deviation with severity set at Informational level occured for arg1 . Arguments arg1 = virtual disk names Detailed Description The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Informational level. Recommended Response Action Make appropriate assignments of hotspares to meet the policy.
Trap/EventID Filter Visibility 4355 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ VDR102 Message Hot Spare Protection policy deviation with severity set at Warning level occured for arg1 .
Arguments arg1 = virtual disk names Detailed Description The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Critical level. Recommended Response Action Make appropriate assignments of hotspares to meet the policy.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR105 Message The arg1 on power save mode drives is available. Arguments arg1 = virtual disk name Detailed Description Virtual Disk creation using power save mode drives successfully completed and the Virtual Disk identified in the message is ready for use.
Recommended Response Action No response action is required. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) OMSA Event ID 2404 OMSA Trap ID 120100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR107 Message Successfully resized Controller Enhanced cache ( arg1 ).
LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR108 Message Successfully created Controller Enhanced cache ( arg1 ). Arguments arg1 = virtual disk name Detailed Description The Controller Enhanced cache identified in the message was successfully created. Recommended Response Action No response action is required.
OMSA Event ID 2414 OMSA Trap ID 120100 Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR11 Message arg1 has started initializing. Arguments arg1 = virtual disk Detailed Description This message is generated after initialization of a virtual disk starts. Recommended Response Action No response action is required.
VDR110 Message Unrecoverable storage medium error detected on arg1 . Arguments arg1 = virtual disk name Detailed Description This alert is generated when an unrecoverable storage medium error is detected on the virtual disk. This error can be a prelude to the physical disk disk becoming nonfunctional. Recommended Response Action Make sure a hot spare to the Virtual Disk identified in the message is available and back up the data on the virtual disk.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔ Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ CMC VDR112 Message Deleted the arg1 . Arguments arg1 = virtual disk Detailed Description The controller removed a virtual disk because of a delete virtual disk operation or a reset configuration operation. Recommended Response Action No response action is required.
Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2063 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔ VDR13 Message arg1 rebuild has started. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes.
VDR14 Message The consistency check on arg1 was cancelled. Arguments arg1 = virtual disk Detailed Description A user cancelled the consistency check operation for a virtual disk. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 120100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR16 Message Consistency check of arg1 failed. Arguments arg1 = virtual disk Detailed Description A physical disk included in the virtual disk failed or there is an error in the parity information. A failed physical disk causes errors in parity information.
Arguments arg1 = VD Name Detailed Description A physical disk included in the virtual disk failed. Recommended Response Action Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a red "X" for its status. Rebuild the physical disk. When finished, restart the virtual disk format operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR19 Message Reconfiguration of arg1 has failed. Arguments arg1 = virtual disk Detailed Description The reconfiguration operation was not completed. This may be due to a user action or a physical disk failure.
Detailed Description The virtual disk has returned to a healthy state and is working properly. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* ✔* VDR21 Message Consistency check for arg1 has completed. Arguments arg1 = virtual disk Detailed Description This message is generated after a consistency check completes on a virtual disk. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2086 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR23 Message Initialization of arg1 has completed.
VDR24 Message Reconfiguration of arg1 has completed. Arguments arg1 = virtual disk Detailed Description The re-configuration operation on the virtual disk completed. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 120100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR26 Message The check consistency on a arg1 has been paused (suspended). Arguments arg1 = VD Name Detailed Description You paused the Check Consistency operation on a virtual disk.
Arguments arg1 = VD Name Detailed Description The check consistency on a virtual disk has resumed processing after a pause. Recommended Response Action This alert is provided for informational purposes.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR29 Message A mirrored virtual disk has been un-mirrored. Detailed Description A mirrored virtual disk is un-mirrored. When a virtual disk is mirrored, its data is copied to another virtual disk to maintain redundancy.
Detailed Description Data redundancy has been restored to a virtual disk that previously suffered a loss of redundancy. Recommended Response Action This alert is provided for informational purposes.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR31 Message Controller cache is preserved for missing or offline arg1 . Arguments arg1 = VD Name Detailed Description The controller is getting disconnected from its virtual disk, while Input Output (IO) is in-progress. Recommended Response Action Try importing foreign disks, if any. Check if the enclosure containing the Virtual Disk is disconnected from the controller.
Recommended Response Action No response action is required. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2127 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR33 Message Background initialization was cancelled for arg1 .
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR34 Message Background initialization failed for arg1 . Arguments arg1 = virtual disk Detailed Description Background initialization of a virtual disk failed. Recommended Response Action Run a consistency check on the virtual disk. If that fails, check the health of the member drives of the virtual disk and then recreate.
Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2130 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR36 Message arg1 initialization is in-progress arg2 . Arguments arg1 = VD Name, arg2 = progresspercent Detailed Description Virtual disk initialization is in-progress.
VDR37 Message Dead disk segments are restored on arg1 . Arguments arg1 = VD Name Detailed Description Disk space that was formerly "dead" or inaccessible to a redundant virtual disk has been restored. This alert is provided for informational purposes. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 120100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR39 Message The check consistency has made corrections and completed for arg1 . Arguments arg1 = VD name Detailed Description The virtual disk check consistency has identified issues and made corrections.
VDR4 Message arg1 was created. Arguments arg1 = virtual disk Detailed Description This message is generated after a virtual disk was created on a controller. Recommended Response Action No response action is required.
OMSA Trap ID Filter Visibility 120100 IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR41 Message arg1 read policy has changed. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Arguments arg1 = args Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR44 Message arg1 disk cache policy has changed. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* VDR47 Message A disk media error was corrected on arg1 . Arguments arg1 = virtual disk Detailed Description A disk media error was detected while the controller was completing a background task. A bad disk block was identified. The disk block was remapped. Recommended Response Action Check the Lifecycle log for information related to members of this virtual disk.
Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2281 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* ✔* VDR49 Message arg1 is permanently degraded. Arguments arg1 = VD Name Detailed Description A redundant virtual disk has lost redundancy.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR5 Message arg1 was deleted. Arguments arg1 = virtual disk Detailed Description The controller removed a virtual disk. This is due to a delete virtual disk operation, a reset configuration operation, or the removal of every physical disk that was a member of the virtual disk. Recommended Response Action No response action is required.
Recommended Response Action Review other messages to identify whether the physical disk that has errors. If the virtual disk is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual disk is non-redundant, you need to recreate the virtual disk after replacing the physical disk. After replacing the physical disk, run a consistency check to verify the data.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR52 Message The consistency check found inconsistent parity data on arg1 . Arguments arg1 = virtual disk Detailed Description The data on physical disk members of the virtual disk does not match. Redundancy may be lost. Recommended Response Action Rerun the consistency check task. If you receive this message again, verify the health of the physical disks included in the virtual disk.
Recommended Response Action See the storage hardware documentation for more information on consistency check operation. Contact technical support.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR55 Message arg1 initialization has failed. Arguments arg1 = VD Name Detailed Description The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective. Recommended Response Action Verify the health of attached devices. Review the Alert Log for significant events. Make sure the cables are attached securely.
Recommended Response Action Replace the missing or failed physical disk. Category Storage (VDR = Virtual Disk) Severity Severity 3 (Informational) Trap/EventID 4355 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR57 Message Background Initialization in arg1 corrected medium error.
VDR58 Message Bad block medium error is detected at block arg1 on arg2 . Arguments arg1 = args, arg2 = VD Name Detailed Description Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks. Recommended Response Action Recovering a physical disk bad block depends on the RAID level and state of the virtual disk. If a virtual disk is redundant, the controller can recover a bad block on a physical disk.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR6 Message arg1 configuration has changed. Arguments arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Detailed Description There are two modes of virtual disk initialization, full and fast. This initialisation type identified in the message is running on the virtual disk identified in the message. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR8 Message arg1 has become degraded. Arguments arg1 = virtual disk Detailed Description This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.
Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* VDR92 Message Consistency check for arg1 has completed with uncorrectable errors. Arguments arg1 = virtual disk Detailed Description This message occurs if there are medium errors in the physical drives. Recommended Response Action Replace the failed drives.
Severity Severity 3 (Informational) Trap/EventID 4355 OMSA Event ID 2389 OMSA Trap ID 120100 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR94 Message Controller preserved cache was recovered for arg1 . Arguments arg1 = virtual disk Detailed Description This message occurs if the controller pinned cache is recovered.
VDR95 Message Unable to log block arg1 .Bad block table on arg2 is full. Arguments arg1 = arg, arg2 = VD Name Detailed Description This alert message occurs if the virtual disk has bad blocks. Recommended Response Action Replace the disk in the Virtual disk, generating this alert and restore from backup. You may have lost data.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ iDRAC ✔ ✔ ✔ ✔ CMC ✔ ✔* ✔ ✔* OS Log Power Off Power Cycle LC Log iDRAC ✔* CMC ✔ LCD Reset Chassis Event Proxy ✔ ✔* VDR97 Message Patrol Read corrected a media error on arg1 . Arguments arg1 = VD Name Detailed Description The Patrol Read task has encountered an error such as a bad disk block and remapped data to correct the error. Recommended Response Action No response action is required.
Detailed Description The virtual disk identified in the message has changed active paths. This can be because of an attempt to optimize the throughput of the system or it could be because of a controller failover. Recommended Response Action No response action is required.
LC Log iDRAC ✔* CMC ✔ LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔ ✔* ✔* 2313
VF Event Messages VF001 Message Command successful. Detailed Description The command was successful Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF002 Message General failure Detailed Description The operation did not complete successfully because of an internal issue with the firmware.
VF004 Message Invalid value for the parameter: arg1 Arguments arg1 = parameter name Detailed Description The value of the input parameter identified in the message is not a valid value. Recommended Response Action Refer the iDRAC and Lifecycle Controller User Guides for the required input parameters for this method.
VF0060 Message Unable to perform the requested operation. Make sure the SD card is inserted and enabled. Detailed Description The SD card was not detected. Therefore, the requested operation cannot be completed. Recommended Response Action Verify whether the SD card is inserted and enabled, then re-try.
VF009 Message Partition formatting successful Detailed Description The specified partition was formatted. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF010 Message Partition formatting did not complete successfully. Detailed Description Formatting the specified partition did not complete successfully.
VF012 Message SD card not present Detailed Description There is no SD card detected. Recommended Response Action Check the SD card slot. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF013 Message SD card locked Detailed Description The SD card is locked by another operation.
VF015 Message vFlash not enabled Detailed Description Disabling vFlash was not successful because the vFlash feature is not enabled. Recommended Response Action The vFlash is disabled and an attempts to disable it will not be successful. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF016 Message SD card is read only Detailed Description The SD card is not writable.
VF018 Message Invalid partition index Detailed Description The specified partition index is not valid for the command. Recommended Response Action Check that the partition exists. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF019 Message Not enough space on SD card Detailed Description The SD card is full.
VF021 Message Exceeded maximum partition size of 4GB Detailed Description The size specified is greater than the maximum allowed for a partition. Recommended Response Action Try a partition size that is smaller than 4GB and the available space on the card.
VF024 Message Partition locked Detailed Description The partition is locked by another operation. Recommended Response Action Wait for the partition to be unlocked and check the partition status to see if it is attached.
VF027 Message Partition already attached Detailed Description This partition is attached and attempts to attach it will fail. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF028 Message Partition already detached Detailed Description This partition is detached and attempts to detach it will fail. Recommended Response Action No response action is required.
VF030 Message Invalid hash type Detailed Description The specified hash type is not a valid type. Recommended Response Action Provide a valid hash type. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF031 Message Invalid partition label. Detailed Description The specified partition label is not a valid label. Recommended Response Action Try a label that complies with the standards for an OS volume label.
VF033 Message Invalid partition format type. Detailed Description The specified format type is not a valid type. Recommended Response Action Try a format type that is supported. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF034 Message Invalid partition access type. Detailed Description The specified partition access type is not a valid type. Recommended Response Action Try a partition access type that is supported.
VF036 Message Attach partition successful. Detailed Description The partition was attached. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF037 Message Attach partition operation did not complete successfully. Detailed Description The attaching partition operation did not complete successfully. Recommended Response Action No response action is required.
VF039 Message Detach partition operation did not complete successfully. Detailed Description The detaching partition operation did not complete successfully. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF040 Message Image hash verification was not successful. Detailed Description The downloaded image did not successfully complete the hash verification.
VF042 Message Remote file missing. Detailed Description The remote file could not be found. Recommended Response Action Check the mount area. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF043 Message Remote file too large. Detailed Description The file size is too large to be used. Recommended Response Action Try a smaller file.
VF045 Message FTP download operation was not successful. Detailed Description File transfer was not successful. This could be because of network problems or an operational problem with the file server. Recommended Response Action Try the download again. If the issue persists, validate that the network share is operational. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF046 Message HTTP download operation was not successful.
VF048 Message Initialize media successful. Detailed Description The SD card was initialized. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 3 (Informational) No alerts are applicable for this message VF049 Message Initialize media operation did not complete successfully. Detailed Description The initializing SD card operation did not complete successfully. Recommended Response Action No response action is required.
VF051 Message Export partition operation did not complete successfully. Detailed Description The copying partition operation did not complete successfully. Recommended Response Action No response action is required. Category Configuration (VF = vFlash Media) Severity Severity 2 (Warning) No alerts are applicable for this message VF052 Message Media not ready. Detailed Description The device is not ready to access media information. Recommended Response Action Try the operation later again.
VFL Event Messages VFL0001 Message The vFlash SD Card operation is successful. Detailed Description The requested operation for the vFlash SD Card completed successfully. Recommended Response Action No response action is required. Category Configuration (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0002 Message Unable to query the vFlash media status.
VFL0004 Message Unable to perform the vFlash media operation. Detailed Description The requested vFlash media operation could not be performed, because some of the iDRAC services are busy. Recommended Response Action Retry the operation. If the issue persists, restart the iDRAC and retry the operation. If the issue continues to persist, contact your service provider.
VFL0009 Message vFlash media is currently in use by another operation. Detailed Description Unable to access the vFlash media, because another operation is currently using the vFlash media. Recommended Response Action Wait until the vFlash media is available for the requested operation, and then retry the operation. Category System Health (VFL = vFlash Event) Severity Severity 2 (Warning) No alerts are applicable for this message VFL0010 Message An operation is in progress on the SD card.
VFL0012 Message vFlash media is not enabled. Detailed Description The vFlash media is not enabled. Recommended Response Action Enable the vFlash media by running the command racadm set idrac.vFlashSD.Enable 1. Category System Health (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0013 Message The vFlash SD Card is in read-only mode.
VFL0015 Message vFlash media partition is of read-only type. Detailed Description The request could not be successfully completd, because the vFlash SD Card partition is in read-only mode. Write operations cannot be performed on the card partition. Recommended Response Action Change the partition access type to read-write by running the command racadm set idrac.vFlashPartition..accesstype 1.
VFL0018 Message The requested operation is in progress. Detailed Description The requested operation is currently in progress. Recommended Response Action Wait for the requested operation to complete. Category Configuration (VFL = vFlash Event) Severity Severity 3 (Informational) No alerts are applicable for this message VFL0019 Message The vFlash media partition is already in detached state.
VFL0021 Message One of the vFlash SD Card partitions is already attached to the host operating system. Detailed Description The requested operation cannot be performed if one of the vFlash SD cards is in an attached state. Recommended Response Action Detach the vFlash SD Card partitions by running the racadm command "racadm set iDRAC.vflashpartition..attachstate 0". and retry the operation.
VFL0705 Message Error occurred and SD card could not be initialized. Detailed Description An error has occurred while initializing the SD card. The SD card is not present or vFlash is not enabled, or the SD card is write-protected. Recommended Response Action Re-insert the SD card, enable the SD card, or disable write-protection on the SD card. Then try to initialize the SD card again.
VFL0711 Message SD card is write-protected and could not be initialized. Detailed Description An error occurred while initializing the SD card because the SD card writeprotection feature is enabled. Recommended Response Action Move the SD card write-protection tab to the disabled position and try again.
VFL0714 Message SD card is not ready and could not be initialized. Detailed Description none Recommended Response Action Retry after a few minutes. Category Configuration (VFL = vFlash Event) Severity Severity 1 (Critical) No alerts are applicable for this message VFL0715 Message Error occurred while initializing the SD Card due to insufficient permission. Detailed Description None Recommended Response Action Contact the administrator for the required permissions and try again.
VFL0719 Message One or more partitions are in use; the SD card could not be initialized. Detailed Description The SD card is in use by another process. Initialization requires exclusive access to the SD card to complete the initialization. Recommended Response Action The SD card is in use by another process. Retry after a few minutes.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VFL1002 Message Removable Flash Media arg1 is IPMI-function ready. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health (VFL = vFlash Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1004 Message Removable Flash Media arg1 is ready. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action Please wait for the media to be ready. Category System Health (VFL = vFlash Event) Severity Severity 2 (Warning) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1006 Message Removable Flash Media arg1 is offline.
VFL1007 Message Removable Flash Media arg1 is online. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health (VFL = vFlash Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1008 Message Failure detected on Removable Flash Media arg1 .
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VFL1009 Message Removable Flash Media arg1 is operating normally. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category System Health (VFL = vFlash Event) Severity Severity 3 (Informational) Trap/EventID 2507 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VFL1011 Message Removable Flash Media arg1 was deactivated.
VFL1012 Message Removable Flash Media arg1 is booting. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health (VFL = vFlash Event) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VFL1013 Message Removable Flash Media arg1 has finished booting.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VFL1014 Message Removable Flash Media arg1 is write protected. Arguments arg1 = name Detailed Description The card is write-protected by the physical latch on the SD card. IDSDM cannot use a write-protected card. Recommended Response Action if unintended, remove the media and disable write protection.
Trap/EventID iDRAC 2507 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VFL1016 Message Media not present for Removable Flash Media arg1 . Arguments arg1 = name Detailed Description The SD card is not detected or not installed. Recommended Response Action If unintended, reinstall the flash media.
Recommended Response Action No response action is required.
VFLA Event Messages VFLA1000 Message Removable Flash Media arg1 is absent. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
VLT Event Messages VLT0100 Message Processor module arg1 voltage is less than the lower warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VLT0102 Message Processor module arg1 voltage is greater than the upper warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action 1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (VLT = Voltage) Severity Severity 1 (Critical) LCD Message Processor module voltage is outside of range .
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0105 Message Processor module arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 2170 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* VLT0201 Message The system board arg1 voltage is less than the lower critical threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
VLT0202 Message The system board arg1 voltage is greater than the upper warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables.
LCD Message The system board voltage is outside of range. Contact support Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* VLT0204 Message The system board arg1 voltage is outside of range. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0207 Message The memory module arg1 arg2 voltage is less than the lower critical threshold. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions.
Category System Health (VLT = Voltage) Severity Severity 2 (Warning) Trap/EventID 2170 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0209 Message The memory module arg1 arg2 voltage is greater than the upper critical threshold.
VLT0210 Message The memory module arg1 arg2 voltage is outside of range. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support.
iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VLT0212 Message The disk drive bay arg1 voltage is less than the lower warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0215 Message The disk drive bay arg1 voltage is greater than the upper critical threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0217 Message The disk drive bay arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing iDRAC ✔ ✔* ✔ ✔ ✔ ✔ CMC ✔ ✔ ✔ ✔ OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ LC Log iDRAC ✔* CMC ✔* LCD Chassis Event Proxy ✔* VLT0220 Message The arg1 voltage is greater than the upper warning threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message The voltage is outside of range.
LC Log iDRAC ✔* CMC ✔* LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy ✔* VLT0223 Message The arg1 voltage is within range. Arguments arg1 = name Detailed Description None Recommended Response Action No response action is required.
Trap/EventID iDRAC 2170 Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0225 Message The memory module arg1 voltage is less than the lower critical threshold. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0228 Message The memory module arg1 voltage is outside of range. Arguments arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module.
Severity Severity 3 (Informational) Trap/EventID 2171 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle CMC iDRAC ✔* Reset Chassis Event Proxy ✔ CMC VLT0230 Message The mezzanine card arg1 arg2 voltage is less than the lower warning threshold. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0233 Message The mezzanine card arg1 arg2 voltage is greater than the upper critical threshold. Arguments arg1 = number, arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions.
Severity Severity 1 (Critical) Trap/EventID 2169 iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0235 Message The mezzanine card arg1 arg2 voltage is within range. Arguments arg1 = number, arg2 = name Detailed Description None Recommended Response Action No response action is required.
Detailed Description Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. The low voltage may cause the processor to fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LC Log iDRAC LCD ✔* OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ Chassis Event Proxy CMC VLT0302 Message CPU arg1 arg2 voltage is greater than the upper warning threshold. Arguments arg1 = number, arg2 = name Detailed Description High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other electronic components inside the system.
Category System Health (VLT = Voltage) Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message CPU voltage is outside of range. Reseat CPU iDRAC Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing ✔ ✔* ✔ ✔ ✔ ✔ LC Log LCD OS Log Power Off Power Cycle Reset ✔ ✔ ✔ ✔ CMC iDRAC ✔* Chassis Event Proxy CMC VLT0304 Message CPU arg1 arg2 voltage is outside of range.
VLT0305 Message CPU arg1 arg2 voltage is within range. Arguments arg1 = number, arg2 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert iDRAC Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VLT401 Message Unable to read arg1 sensor value. Arguments arg1 = sensor name Detailed Description A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Arguments arg1 = sensor name, arg2 = voltage Detailed Description The voltage sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert iDRAC SNMP Alert Email Alert ✔* Remote System Log WS Eventing ✔ ✔ CMC LC Log LCD iDRAC OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VLT404 Message The arg1 sensor detected an error with a value of arg2 Volts. Arguments arg1 = sensor name, arg2 = voltage Detailed Description The voltage sensor identified in the message is faulty, or the voltage exceeds the preset critical threshold.
VLT405 Message The arg1 sensor has failed with a value of arg2 Volts. Arguments arg1 = sensor name, arg2 = voltage Detailed Description A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults.
VME Event Messages VME0001 Message Virtual Console session started. Detailed Description Virtual Console session started. Recommended Response Action No response action is required. Category Audit (VME = Virtual Media) Severity Severity 3 (Informational) Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log LC Log LCD OS Log Power Off Power Cycle WS Eventing iDRAC CMC iDRAC Reset Chassis Event Proxy ✔* CMC VME0002 Message Virtual Media session started.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VME0003 Message Virtual Console session fails to start. Detailed Description Virtual Console session fails to start. Recommended Response Action Retry the Virtual Console session initiation.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VME0005 Message Virtual Console session exited. Detailed Description Virtual Console session exited. Recommended Response Action No response action is required.
LC Log iDRAC LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy ✔* CMC VME0007 Message Virtual Console session created. Detailed Description Virtual Console session created. Recommended Response Action No response action is required.
LC Log iDRAC CMC 2392 ✔* LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
VRM Event Messages VRM0009 Message No Virtual Media devices are currently connected. Detailed Description No virtual media was found to disconnect. Recommended Response Action No response action is required. Category System Health (VRM = Virtual Console) Severity Severity 1 (Critical) No alerts are applicable for this message VRM0010 Message Unable to disconnect Virtual Media devices. Detailed Description The virtual media could not be disconnected. Possible reason is that it might be in use.
VRM0012 Message The Virtual Media image server is already connected. Detailed Description The Virtual Media server is already connected. Recommended Response Action No response action is required. Category System Health (VRM = Virtual Console) Severity Severity 3 (Informational) No alerts are applicable for this message VRM0013 Message Virtual Media services is currently attached to the USB interface.\nIt must be detached before the image server can be connected.
VRM0015 Message Virtual Console is ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (VRM = Virtual Console) Severity Severity 3 (Informational) No alerts are applicable for this message VRM0016 Message Virtual Console is DISABLED Detailed Description Success message. Recommended Response Action No response action is required.
VRM0018 Message Virtual Media image server operation successful Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration (VRM = Virtual Console) Severity Severity 3 (Informational) No alerts are applicable for this message VRM0019 Message Remote Image is now Configured Detailed Description The Remote Image is now configured and ready to use. Recommended Response Action No response action is required.