Reference Guide

Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2309
Description A physical disk is incompatible.
Severity Warning / Non-critical
Cause and Action Cause: You have attempted to replace a disk with another disk that is using an
incompatible technology. For example, you may have replaced one side of a mirror
with a SAS disk when the other side of the mirror is using SATA technology.
Action: See the hardware documentation for information on replacing disks.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2310
Description A virtual disk is permanently degraded.
Severity Critical / Failure / Error
Cause and Action Cause: A redundant virtual disk has lost redundancy. This may occur when the
virtual disk suffers the failure of multiple physical disks. In this case, both the source
physical disk and the target disk with redundant data have failed. A rebuild is not
possible because there is no redundancy.
Action: Replace the failed disks and restore from backup.
Related Alert
Information
Clear Alert Number: 1204
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
157