Reference Guide

Severity Warning / Non-critical
Cause and Action Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may
occur after a power surge, a battery failure, or for other reasons. The controller is
reinitializing the NVRAM. The controller properties reset to the default settings after
the reinitialization is complete.
NOTE: The controller is taking the required corrective action. If this alert is
generated often (such as during each reboot), replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2266
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2328
Description The NVRAM has corrupt data.
Severity Warning / Non-critical
Cause and Action Cause: The NVRAM has corrupt data. The controller is unable to correct the
situation.
Action: Replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 20601
SNMP Trap
Numbers
753
Event ID — 2329
Description SAS port report: %1
Severity Warning / Non-critical
Cause and Action Cause: The text for this alert is generated by the controller and can vary depending
on the situation. The %1 indicates a substitution variable. The text for this
substitution variable is generated by the controller and is displayed with the alert in
the alert log. This text can vary depending on the situation.
Action: Run the PHY integrity test diagnostic. Make sure the cables are attached
securely. If the problem persists, replace the cable with a valid cable according to
SAS specifications. If the problem still persists, you may need to replace some
164