Reference Guide

Action: Replace the power supply.
Related Alert
Information
Clear Alert Number: 1003
Related Alert Number: 2122, 2324
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1003
Event Id — 2313
Description A power supply in the enclosure has a DC failure.
Severity Warning / Non-critical
Cause and Action Cause: The power supply has a DC failure.
Action: Replace the power supply.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: 2122, 2333
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1003
Event ID — 2314
Description
The initialization sequence of SAS components failed during system startup. SAS management and
monitoring is not possible.
Severity Critical / Failure / Error
Cause and Action Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and
rmware. Also, you may need to reinstall Storage Management or Server Administrator because of some
missing installation components.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2051
SNMP Trap
Numbers
104
Event Id — 2315
Description
Diagnostic message %1
Severity OK / Normal / Informational
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the
utility that ran the diagnostics and is displayed with the alert in the alert log. This text can vary depending on
the situation. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
128