Reference Guide

Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2356
Description SAS SMP Communications error %1.
Severity Critical / Failure / Error
Cause and Action Cause: The text for this alert is generated by the rmware and can vary depending on the situation. The
reference to SMP in this text refers to SAS Management Protocol.
Action: There may be a SAS topology error. See the hardware documentation for information on correct
SAS topology congurations. There may be problems with the cables such as a loose connection or an
invalid cabling conguration. See the Cables Attached Correctly section for more information on checking
the cables. See the hardware documentation for information on correct cabling congurations. Verify that
the rmware is a supported version.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2357
Description
SAS expander error: %1.
Severity Critical / Failure / Error
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the
rmware and is displayed with the alert in the alert log. This text can vary depending on the situation.
Action: There may be a problem with the enclosure. Check the health of the enclosure and its components
by selecting the enclosure object in the tree view. The Health subtab displays a red X or yellow exclamation
point for enclosure components that are Failed or Degraded. See the enclosure documentation for more
information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2358
Description
The battery charge cycle is complete.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None