Reference Guide
Power Supply Events
The power supply sensors monitor the functionality of the power supplies. These messages provide status and warning information 
for power supplies for a particular system.
Table 9. Power Supply Events
Event Message Severity Cause
<Power Supply Sensor Name> 
power supply sensor removed.
Critical This event is generated when the power 
supply sensor is removed.
<Power Supply Sensor Name> 
power supply sensor AC 
recovered.
Information This event is generated when the power 
supply has been replaced.
<Power Supply Sensor Name> 
power supply sensor returned 
to normal state.
Information This event is generated when the power 
supply that failed or removed was 
replaced and the state has returned to 
normal.
<Entity Name> PS Redundancy 
sensor redundancy degraded.
Information Power supply redundancy is degraded if 
one of the power supply sources is 
removed or failed.
<Entity Name> PS Redundancy 
sensor redundancy lost.
Critical Power supply redundancy is lost if only 
one power supply is functional.
<Entity Name> PS Redundancy 
sensor redundancy regained.
Information This event is generated if the power 
supply has been reconnected or replaced.
<Power Supply Sensor Name> 
predictive failure was 
asserted.
Critical This event is generated when the power 
supply is about to fail.
<Power Supply Sensor Name> 
input lost was asserted.
Critical This event is generated when the power 
supply is unplugged.
<Power Supply Sensor Name> 
predictive failure was 
deasserted.
Information This event is generated when the power 
supply has recovered from an earlier 
predictive failure event.
<Power Supply Sensor Name> 
input lost was deasserted.
Information This event is generated when the power 
supply is plugged in.
PS 1 Status: Power supply 
sensor for PS 1, presence was 
asserted.
Information This event is generated when the power 
supply is plugged in.
PS 1 Status: Power supply 
sensor for PS 1, presence was 
deasserted.
Critical This event is generated when the power 
supply is removed.
PS 1 Status: Power supply 
sensor for PS 1, failure was 
asserted.
Critical This event is generated when the power 
supply has failed.
PS 1 Status: Power supply 
sensor for PS 1, failure was 
deasserted.
Information This event is generated when the power 
supply has recovered from an earlier 
failure event.