Reference Guide
Cause A temperature sensor on the backplane board, system board, CPU, or drive carrier in the specied system
exceeded its warning threshold. The sensor location, chassis location, previous state, and temperature
sensor value are provided.
Event ID — 1054
Description
Temperature sensor detected a failure value Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state: <State>
Severity Error
Cause A temperature sensor on the backplane board, system board, or drive carrier in the specied system
exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor
value are provided.
Event ID — 1055
Description
Temperature sensor detected a non-recoverable value Sensor location:
<Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state: <State>
Severity Error
Cause A temperature sensor on the backplane board, system board, or drive carrier in the specied system
detected an error from which it cannot recover. The sensor location, chassis location, previous state, and
temperature sensor value information is provided.
Cooling Device Messages
The cooling device sensors listed monitor how well a fan is functioning. Cooling device messages provide status and warning
information for fans in a particular chassis.
Event ID — 1100
Description
Fan sensor has failed Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Severity Error
30