Reference Guide

Previous redundancy state was: <State>
Severity Information
Cause A redundancy sensor in the specied system detected that a unit was not redundant. The redundancy
location, chassis location, previous redundancy state, and the number of devices required for full redundancy
information is provided.
Event ID — 1303
Description
Redundancy is offline Redundancy unit: <Redundancy Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Severity Information
Cause A redundancy sensor in the specied system detected that a redundant unit is oine. The redundancy unit
location, chassis location, previous redundancy state, and the number of devices required for full redundancy
information is provided.
Event ID — 1304
Description
Redundancy regained Redundancy unit: <Redundancy Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Severity Information
Cause A redundancy sensor in the specied system detected that a “lost” redundancy device has been
reconnected or replaced; full redundancy is in eect. The redundancy unit location, chassis location, previous
redundancy state, and the number of devices required for full redundancy information is provided.
Event ID — 1305
Description
Redundancy degraded Redundancy unit: <Redundancy Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Severity Warning
Cause A redundancy sensor in the specied system detected that one of the components of the redundancy unit
has failed but the unit is still redundant. The redundancy unit location, chassis location, previous redundancy
state, and the number of devices required for full redundancy information is provided.
Event ID — 1306
Description
Redundancy lost Redundancy unit: <Redundancy Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Severity Error
Cause A redundancy sensor in the specied system detected that one of the components in the redundant unit has
been disconnected, has failed, or is not present. The redundancy unit location, chassis location, previous
redundancy state, and the number of devices required for full redundancy are provided.
38