Reference Guide
Event ID — 1354
Description
Power supply detected a failure Sensor Location: <Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply>
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Error
Cause A power supply has been disconnected or has failed. The sensor location, chassis location, previous state,
power supply type, additional power supply status, and conguration error type information are provided.
Memory Device Messages
The memory device messages listed provides status and warning information for memory modules present in a particular system.
Memory devices determine health status by monitoring the ECC memory correction rate and the type of memory events that have
occurred.
NOTE: A critical status does not always indicate a system failure or loss of data. In some instances, the system has
exceeded the ECC correction rate. Although the system continues to function, you should perform system maintenance
as described.
NOTE: The <status> can be either critical or non-critical.
Event ID — 1400
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device monitoring has been disabled. The memory module may not be correctly seated, wrongly
congured, or has failed.
Event ID — 1401
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device status is unknown. The memory module may not be correctly seated, wrongly congured, or
has failed.
Event ID — 1402
Description
Memory device status is <status>
Memory device location: <location in chassis>