Reference Guide

Severity Critical / Failure / Error
Cause and Action Cause: AA physical disk included in the virtual disk failed or there is an error in the parity information. A failed
physical disk can cause errors in parity information.
Action: Replace the failed physical disk. You can identify which disk has failed by locating the disk that has a
red “X” for its status. Rebuild the physical disk. When nished, restart the check consistency operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2077
Description Virtual disk format failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk failed.
Action: Replace the failed physical disk. You can identify which physical disk has failed by locating the disk
that has a red X for its status. Rebuild the physical disk. When nished, restart the virtual disk format
operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2079
Description
Virtual disk initialization failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk has failed or a user has cancelled the initialization.
Action: If a physical disk has failed, then replace the physical disk
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2080
Description
Physical disk initialization failed.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk has failed or is not functioning.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk
that has a red “X” for its status. Restart the initialization.
60