Reference Guide
Cause and Action Cause: The controller battery cannot be recharged. The battery may be old or it may have been already
recharged the maximum number of times. In addition, the battery charger may not be working.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2118
Local Response Agent (LRA) Number: 2101
SNMP Trap
Numbers
1154
Event ID — 2170
Description The controller battery charge level is normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2171
Description
The controller battery temperature is above normal.
Severity Warning / Non-critical
Cause and Action Cause: The battery may be recharging, the room temperature may be too hot, or the fan in the system may
be degraded or failed.
Action: If this alert was generated due to a battery recharge, the situation is corrected when the recharge is
complete. You should also check if the room temperature is normal and that the system components are
functioning properly.
Related Alert
Information
Clear Alert Number: 2172
Related Alert Number: None
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2172
Description
The controller battery temperature is normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2172 is a clear alert for alert 2171.
Related Alert Number: None