Release Notes
d Type: omcong system webserver action=start
• A temperature drop below a minimum failure threshold does not cause a system reset even if this alert action is set.
• Clicking the Back and Refresh buttons on the browser may not display the correct page regarding the Server Administrator component 
tree, tabs, tab menus, or help, as Server Administrator has been designed with limited functionality to reduce overhead. Full feature 
capabilities of the Web browser such as Back, Refresh, and Open in New Window may not be supported.
• Selecting the boot sequence under the BIOS Setup tab does not re-enable boot devices that have been disabled in the System Setup 
Program, earlier.
• The links on the Server Administrator home page may not work after repeated random clicking. To resolve this issue, refresh the 
browser by pressing <F5> or click the browser Refresh button.
• All unsecured HTTP requests to Server Administrator receive an invalid response. Server Administrator runs only one instance of the 
Web server, which is secure. Make all connections through https://<ip address>: <port number>. Any http://<ip address>: <port 
number> request for connection with the server receives an invalid response.
• If the web browser used with Server Administrator does not display a page or perform an action, make sure that the browser is in online 
mode. To go online, perform the following:
– In Internet Explorer, on the menu bar, click File and clear the Work Oine option. When Work Oine is selected, a check mark is 
displayed to the left of the option on the File menu.
• If Internet Explorer prompts you to Work Oine, Connect, or Try Again, always select Connect or Try Again. Do not select Work 
Oine.
• In Internet Explorer, on the menu bar, click File and clear the Work Oine option. When Work Oine is selected, a check mark is 
displayed to the left of the option on the File menu.
• If Internet Explorer prompts you to Work Oine, Connect, or Try Again, always select Connect or Try Again. Do not select Work 
Oine
.
• While setting dates in the Asset Information section of the Server Administrator home page, the current time is appended to the date. 
While setting dates with the CLI, the appended time is noon.
• On some systems, temperature probe values and settings are only supported for whole degrees, not tenths of a degree. On those 
systems, setting a fractional value for the minimum warning temperature threshold results in the set value being rounded o to the next 
whole number value. This behavior may cause the minimum warning threshold to have the same value as the minimum failure threshold.
• If you close the browser using the Close button on the browser or log o from the operating system, the Server Administrator session 
is not terminated. This session is listed in the Session Management page until the session time out occurs, or DSM SA connection 
service is restarted, or the operating system is rebooted.
• If you change the operating system Time Zone to a new time zone, Server Administrator session management does not display the time 
in the new time zone specied. Restart Server Administrator to display the accurate time for the time zone in the Session Management 
page.
• DF78425: The Server Administrator Auto Recovery feature may execute the congured action before the time interval when the 
system is under heavy stress.
The Auto Recovery feature can be set to execute an action (For example, system reboot) to recover a hung system. Since the Auto 
Recovery timer is now an application-level timer instead of a kernel-level timer, heavy resource stress on the system may result in an 
inaccurate measurement of a short keep alive interval (less than 120 seconds), and the congured action may be triggered. The issue is 
more prevalent in systems that have only one CPU with hyper-threading unsupported/disabled or systems that are subjected to 
persistent stressful conditions such as, resource depletion and CPU running at 100% usage with signicantly more threads than normal 
usage.
The Auto Recovery feature is not enabled by default. If the Auto Recovery feature has been enabled, increase the System Reset Timer 
value to at least 120 seconds.
• Using the Internet Explorer browser, if you install Server Administrator on a system that includes an underscore in its host name, you 
must use the IP address of the target system in the browser URL to launch Server Administrator, as Host names with underscores are 
not supported. For example, (assuming Server Administrator is listening on port 1311): https://192.168.2.3:1311.
For more information, see the following article on the: Microsoft website http://support.microsoft.com/kb/312461
• DF152755: The Server Administrator GUI does not respond when the alerts log has many events. If the Alert Log contains several 
entries and if you try to navigate to another page, the Server Administrator GUI may take about 30 seconds to display the content.
• DF172125: Power monitoring probes are displayed on certain systems that do not support power monitoring. On certain systems that 
do not support power monitoring, Server Administrator reports the two platform event lters related to a power monitoring as System 
Power Probe Warning and System Power Probe Failure. These two lters are not supported on these systems. That is, you can view 
and congure these lters, but no action is taken.
10
Dell EMC OpenManage Release Notes
Version 9.1.1










