Connectivity Guide
Table 1703. Battery ID
Name 
batteryID
Object ID  1.3.6.1.4.1.674.10893.1.20.130.15.1.13
Description  Represents unique id for battery.
Syntax  Integer
Access  Read-only
Table 1704. Battery Maximum Learn Delay
Name 
batteryMaxLearnDelay
Object ID  1.3.6.1.4.1.674.10893.1.20.130.15.1.14
Description The maximum amount of time (in hours) that the battery learn cycle can be delayed.
Syntax  Integer
Access  Read-only
Table 1705. Battery Learn Mode
Name 
batteryLearnMode
Object ID  1.3.6.1.4.1.674.10893.1.20.130.15.1.15
Description  Indicates current learn mode of the battery.
Possible values:
1: Auto
2: Warn
4: Autowarn
8: Unknown
Syntax  Integer
Access  Read-only
Battery Connection Table
This table describes the connection between each controller battery on the managed system and its controller. Each controller number in 
the table corresponds to that controller instance in the controller Table.
The following object sets up the Battery Connection Table.
Table 1706. Battery Connection Table
Name 
batteryConnectionTable
Object ID  1.3.6.1.4.1.674.10893.1.20.130.16
Description Denes the battery connection table.
428 Storage Management Group