Reference Guide
Event ID — 2166
Description The RAID controller rmware and driver validation was not performed. The conguration le is out of date, missing 
the required information, or not properly formatted to complete the comparison.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of the 
RAID controller rmware and drivers. This situation has occurred because a conguration le is out of date, missing 
the required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap 
Numbers
753
Event ID — 2167
Description
The current kernel version and the non-RAID SCSI driver version are older than the minimum required levels. See 
readme.txt for a list of validated kernel and driver versions.
Severity Warning / Non-critical
Cause and Action Cause: The version of the kernel and the driver do not meet the minimum requirements. Storage Management may 
not be able to display the storage or perform storage management functions until you have updated the system to 
meet the minimum requirements.
Action: See the Readme le for a list of validated kernel and driver versions. Update the system to meet the 
minimum requirements and then reinstall Storage Management.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap 
Numbers
103
Event ID — 2168
Description
The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validated driver 
version.
Severity Warning / Non-critical
Storage Management Message Reference 101