Event Message Severity Cause
PS 1 Status: Power supply 
sensor for PS 1, configuration 
error was asserted.
Warning/Critical This event is generated when an invalid 
power supply conguration is detected.
PS 1 Status: Power supply 
sensor for PS 1, configuration 
error was deasserted.
Information This event is generated when the power 
supply has recovered from an earlier invalid 
conguration.
Power supply <number> is 
present.
Information This event is generated when the power 
supply is plugged in.
Power supply <number> is 
absent.
Critical This event is generated when the power 
supply is removed.
Power supply <number> failed.
Critical This event is generated when the power 
supply has failed.
A predictive failure detected 
on power supply <number>.
Warning This event is generated when the power 
supply is about to fail.
The power input for power 
supply <number> is lost.
Critical This event is generated when input power is 
removed from the power supply.
The input power for power 
supply <number> has been 
restored.
Information This event is generated if the power supply 
has been reconnected or replaced.
Power supply <number> is 
incorrectly configured.
Critical/Warning This event is generated when an invalid 
power supply conguration is detected.
Power supply <number> is 
correctly configured.
Information This event is generated when the power 
supply has recovered from an earlier invalid 
conguration.
Power supply <number> is 
operating normally.
Information This event is generated when the power 
supply has recovered from an earlier failure 
event.
Cannot communicate with power 
supply <number>.
Critical The power supply may operate, however 
power supply monitoring is degraded.
The temperature for power 
supply <number> is in a 
warning range.
Warning Temperature of specied power supply 
entered into non-critical state.
The temperature for power 
supply <number> is outside of 
range.
Critical Temperature of specied power supply 
entered into critical state.
An under voltage fault 
detected on power supply 
<number>.
Critical The specied power supply detected 
inecient voltage.
An over voltage fault detected 
on power supply <number>.
Critical The specied power supply detected an 
over voltage condition.
An over current fault detected 
on power supply <number>.
Crotoca; The specied power supply detected an 
over current condition.
System Event Log Messages for IPMI Systems 221