Reference Guide
Event Message Severity Cause
<number> device <number> 
function <number>.
A bus correctable error was 
detected on a component at 
slot <number>.
Critical This is generated when the system has 
detected bus correctable errors.
A bus uncorrectable error was 
detected on a component at bus 
<number> device <number> 
function <>number>.
Critical This is generated when the system has 
detected bus uncorrectable errors.
A bus uncorrectable error was 
detected on a component at 
slot <number>.
Critical This is generated when the system has 
detected bus uncorrectable errors.
A fatal error was detected on 
a component at bus <number> 
device <number> function 
<number>.
Critical This error is generated when a fatal error is 
detected on the PCI bus.
A fatal error was detected on 
a component at slot <number>.
Critical This error is generated when a fatal error is 
detected on the PCI bus.
A fatal IO error detected on a 
component at bus <number> 
device <number> function 
<number>.
Critical This error is generated when a fatal IO error 
is detected.
A fatal IO error detected on a 
component at slot <number>.
Critical This error is generated when a fatal IO error 
is detected.
A non-fatal PCIe error 
detected on a component at bus 
<number> device <number> 
function <number>.
Warning This event is generated in association with a 
CPU IERR.
A non-fatal PCIe error 
detected on a component at 
slot <number>.
Warning This event is generated in association with a 
CPU IERR.
A non-fatal IO error detected 
on a component at bus <number> 
device <number> function 
<number>.
Warning This event is generated in association with a 
CPU IERR and indicates the PCI/PCIe 
device that caused the CPU IERR.
Memory device was added at 
location <location>.
Information This event is generated when memory is 
added to the system.
Memory device is removed from 
location <location>.
Information This event is generated when memory is 
removed from the system.
Unsupported memory 
configuration; check memory 
device at location <location>.
Critical This event is generated when memory 
conīguration is incorrect for the system.
Correctable memory error rate 
exceeded for <location>.
Warning This event is generated when correctable 
ECC errors have increased from a normal 
rate.
System Event Log Messages for IPMI Systems 233