SNMP Reference Guide for iDRAC and Chassis Management Controller May 2020 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction................................................................................................................................. 5 What is new in this release................................................................................................................................................... 5 Supported SNMP Versions..................................................................................................................................................
Blade Servers................................................................................................................................................................. 65 Rack and Tower Servers.............................................................................................................................................. 65 iDRAC Supported SNMP Versions...................................................................................................................................
1 Introduction This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC and Chassis Management Controller. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
Table 2. Managed Object Used in This Document MIB Name Agent / Hardware Supported Purpose of the MIB 10892.mib Server Administrator Provides the information about the systems monitored by Server Administrator instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.mib Server Administrator Provides the information about the system Field Replaceable Unit (FRU) to SNMP management applications. dcstorag.
Table 3. Server Administrator Remote Access MIB Sections in This Guide Topic MIB Group Numbers destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations Dell Remote Access Controller Out-of-Band MIB The Dell Remote Access Controller Out-of-Band MIB (filename DELL-RAC-MIB.txt) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting.
Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects.
Table 8. UUID Index(continued) Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 9. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 10. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis.
Table 12. System Battery Index(continued) Description This attribute defines the index (one based) of the battery. Syntax ObjectRange Access Read-only Table 13. System Battery State Capabilities Name systemBatteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.3 Description This attribute defines the state capabilities of the battery. Syntax StateCapabilitiesFlags Access Read-only Table 14. System Battery State Settings Name systemBatteryStateSettings Object ID 1.3.6.1.4.1.
Amperage Probe Table The amperage probe objects provide information about the system amperage probe in which the iDRAC resides. Table 18. Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.1 Description This attribute defines the index (one based) of the system chassis. Syntax ObjectRange Access Read-only Table 19. Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.
Table 23. Amperage Probe Reading(continued) Description This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute.
Table 28. Amperage Probe Upper NonCritical Threshold(continued) Description This attribute defines the upper noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. Syntax Signed32BitRange Access Read-only Table 29. Amperage Probe Lower NonCritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.
Table 33. Amperage Probe Discrete Reading(continued) amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax AmperageDiscreteReadingEnum Access Read-only Power Unit Group The Power Group objects provide information about the system power unit in which the iDRAC resides. Table 34. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.
Table 38. Power Unit Redundancy Status (continued) Syntax StatusRedundancyEnum Access Read-only Table 39. Power Supply Count For Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.6 Description This attribute defines the total number of power supplies required for this power unit to have full redundancy. Syntax ObjectRange Access Read-only Table 40. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.
Table 43. Power Supply Index(continued) Access Read-only Table 44. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 Description This attribute defines the state capabilities of the power unit. Syntax StateCapabilitiesFlags Access Read-only Table 45. Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 Description.
Table 49. Power Supply Location Name(continued) Description This attribute defines the location of the power supply. Syntax String64 Access Read-only Table 50. Power Supply Maximum Input Voltage Name powerSupplyMaximumInputVoltage Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 Description This attribute defines the maximum input voltage of the power supply (in Volts). Syntax Signed32BitRange Access Read-only Table 51.
Table 54. Power Supply Power Monitor Capable(continued) Access Read-only Table 55. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.14 Description This attribute defines the rated input wattage of the power supply (in tenths of Watts). Syntax Signed32BitRange Access Read-only Table 56. Power Supply FQDD Name powerSupplyFQDD Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.
Table 60. Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.3 Description This attribute defines the state capabilities of the power usage information. Syntax StateCapabilitiesFlags Access Read-only Table 61. Power Usage State Settings Name powerUsageStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.4 Description. This attribute defines the state settings of the power usage information.
Table 65. Power Usage Cumulative Wattage Start Date Name(continued) Access Read-only Table 66. Power Usage Peak Watts Name powerUsagePeakWatts Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.9 Description This attribute defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. Syntax Unsigned32BitRange Access Read-only Table 67.
Table 71. Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.14 Description This attribute defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. Syntax DateName Access Read-only Table 72. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.15 Description This attribute defines the system idle power (in Watts).
Table 76. Power Usage Power Cap Value(continued) Syntax Unsigned32BitRange Access Read-only Table 77. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.20 Description This attribute defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax Unsigned32BitRange Access Read-only Table 78.
Table 81. Voltage Probe State Capabilities(continued) Access Read-only Table 82. Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.4 Description. This attribute defines the state settings of the voltage probe. Syntax StatusProbeEnum Access Read-only Table 83. Voltage Probe Status Name voltageProbeStatus Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.5 Description This attribute defines the probe status of the voltage probe.
Table 87. Voltage Probe Upper Non Recoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.9 Description This attribute defines the upper non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. Syntax Signed32BitRange Access Read-only Table 88. Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.
Table 92. Voltage Probe Lower NonRecoverable Threshold(continued) Description This attribute defines the lower non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. Syntax Signed32BitRange Access Read-only Table 93. Voltage Probe Probe Capabilities Name voltageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.15 Description This attribute defines the probe capabilities of the voltage probe.
Table 97. System Express Service Code(continued) Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 98. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system. Syntax StringType Access Read-only Table 99. System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.
Table 103. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 104. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.1.3.10.0 Description This attribute defines the Rack locator of the system. Syntax StringType Access Read-only Table 105. System Rack Slot Name systemRackSlot Object ID 1.3.6.1.4.1.674.10892.5.1.3.11.
Table 109. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.0 Description This attribute defines the Room locator of the system. Syntax StringType Access Read-only Table 110. System Chassis System Height Name systemChassisSystemHeight Object ID 1.3.6.1.4.1.674.10892.5.1.3.16.0 Description This attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component.
Table 114.
2 Chassis Management Controller Group Table 115. Chassis Management Controller Group Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting.
Table 119. DRsProductManufacturer Name drsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only Table 120. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 121.
Table 125. DRsProductChassisName Name drsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 126. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 127. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Table 131. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 132. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis. Syntax DellString Access Read-only Table 133. DRsProductChassisRackSlot Name drsProductChassisRackSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Table 137. DRsProductChassisSize Name drsProductChassisSize Object ID 1.3.6.1.4.1.674.10892.2.1.1.22 Description Defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. Syntax INTEGER Access Read-only Table 138. DRsFirmwareVersion Name drsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller 1.
Table 142. DRsGlobalCurrStatus(continued) Object ID 1.3.6.1.4.1.674.10892.2.3.1.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 143. DRsIOMCurrStatus Name drsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 144.
Table 148. DRsBladeCurrStatus Name drsBladeCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.7 Description Defines the blade subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 149. DRsTempCurrStatus Name drsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 150.
Table 153. DRsCMCProcessorTemperature(continued) Syntax DellTemperatureReading Access Read-only Table 154. DRsGlobalPrevStatus Name drsGlobalPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.1 Description Defines the previous chassis status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 155. DRsIOMPrevStatus Name drsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Table 159. DRsFanPrevStatus Name drsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 160. DRsBladePrevStatus Name drsBladePrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.7 Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 161.
Table 164. DRsIOMChangeTime(continued) Access Read-only Table 165. DRsKVMChangeTime Name drsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only Table 166. DRsRedChangeTime Name drsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only Table 167.
Table 170. DRsTempChangeTime(continued) Description Defines the timestamp of the most recent temperature sensor health status change. Syntax TimeTicks Access Read-only Table 171. DRsCMCChangeTime Name drsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change.
Table 175. DRsCMC PSUTableEntry(continued) Access Not-accessible CMC Power Information The following MIB tables provide information on the chassis power. Table 176. DRsChassisIndex Name drsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only Table 177. DRsPotentialPower Name drsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Table 181. DRsKWhCumulative Name drsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only Table 182. DRsKWhCumulativeTime Name drsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset. Syntax DellTimestamp Access Read-only Table 183.
Table 187. DRsWattsResetTime Name drsWattsResetTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12 Description Defines the time stamp of the most recent reset of the chassis minimum/maximum watts readings. Syntax DellTimestamp Access Read-only Table 188. DRsWattsReading Name drsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in watts). Syntax DellPowerReading Access Read-only Table 189.
Table 192. DRsPSULocation(continued) Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only Table 193. DRsPSUMonitoringCapable Name drsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4 Description Defines the monitoring capabilities or the absence of a PSU in this location. Syntax DellCMCPSUCapable Access Read-only Table 194. DRsPSUVoltsReading Name drsPSUVoltsReading Object ID 1.3.6.1.4.1.674.10892.2.4.
Table 197. DRsCMCServerTable(continued) Syntax SEQUENCE OF DrsCMCServerTableEntry Access Not-Accessible Table 198. DRsCMCServerTableEntry Name drsCMCServerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.5.1.1 Description Defines the CMC server table entry. Syntax DrsCMCServerTableEntry Access Not-Accessible CMC Server Information The following MIB tables provide CMC server information being monitored by the chassis management controller. Table 199.
Table 203. DRsServerSlotNumber Name drsServerSlotNumber Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.5 Description Defines the chassis slot number of the CMC server. Syntax DellString Access Read-only Table 204. DRsServerNodeID Name drsServerNodeID Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.6 Description Defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. Syntax DellString Access Read-only Table 205. DRsServerModel Name drsServerModel Object ID 1.3.
Table 208. DRsServerStorageMode(continued) Access Read-only Table 209. DRsServerIntrusionState Name drsServerIntrusionState Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.11 Description This attribute defines the Intrusion State of the CMC server if supported by the server. Syntax DellCMCServerIntrusionState Access Read-only Table 210. DRsServerAssignedServerSlots Name drsServerAssignedServerSlots Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.
Table 213. DrsCASSPrevStatus(continued) Access Read-only Table 214. DrsCASSChangeTime Name drsCASSChangeTime Object ID 1.3.6.1.4.1.674.10892.2.20.10.4 Description Defines the time stamp of the most recent change of the alerting subsystem. Syntax TimeTicks Access Read-only Table 215. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 216.
Table 219. DrsCA2AlertStatus Name drsCA2AlertStatus Object ID 1.3.6.1.4.1.674.10892.2.21.10.4 Description Defines the status of the alert. Syntax DellStatus Access Read-only Table 220. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 221.
Table 224. DRsAlertCurrentStatus(continued) Description Current status of object causing the alert. Syntax DellStatus Access Read-only Table 225. DRsAlertPreviousStatus Name drsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only Table 226. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
3 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 227. RAC Traps TrapID Name Description Severity Category Cause Supporte d by RAC Platform 0 CodeStart SNMP agent is initializing itself Information Status RAC power on or reset. All 1 Authentication Failure Request received with an invalid community name Critical Error SNMP request with an invalid community name. All 1001 alertDrscTest TrapEvent The RAC generated a test trap event in response to a user request Information Status A test SNMP trap generated by a RAC.
Table 228.
Table 228.
Table 228.
System Trap Group The System Trap Group contains traps that fall under the System event category. Table 230. Amperage Probe Traps TrapID Description Category SubCategory Severity Current sensor reading is within range. Status Events Amperage Informational Current sensor has detected a warning value. Status Events Amperage Minor Current sensor has detected a failure value.
Table 234. Fan Traps(continued) TrapID Description Category SubCategory Severity Fan warning. Status Events Fan Minor Fan failure. Error Events Fan Critical Category SubCategory Severity Status Events Hardware Configuration Informational Hardware configuration warning. Status Events Hardware Configuration Minor Hardware configuration failure or critical event. Error Events Hardware Configuration Critical Description Category SubCategory Severity IO Virtualization warning.
Table 238. Power Supply Traps(continued) TrapID Description Category SubCategory Severity Status Events Power Supply Informational Description Category SubCategory Severity Power supply is absent. Error Events Power Supply Critical Description Category SubCategory Severity Redundancy information. Status Events Redundancy Informational Redundancy is degraded. Status Events Redundancy Minor Redundancy is lost.
Table 243. Software Configuration Traps(continued) TrapID Description Category SubCategory Severity 2338 Software configuration warning. Status Events Software Configuration Minor Table 244. Temperature Probe Traps TrapID Description Category SubCategory Severity Temperature sensor value is within range. Status Events Temperature Informational Temperature sensor has detected a warning value. Status Events Temperature Minor Temperature sensor has detected a failure value.
Table 246. Storage Battery Traps(continued) TrapID Description Category Subcategory Severity Storage battery warning. Error Events Battery Minor Storage battery failure. Error Events Battery Critical Description Category Subcategory Severity Storage controller information. Error Events Controller Informational Storage controller warning. Error Events Controller Minor Storage controller failure.
Table 250. Storage Physical Disk Traps(continued) TrapID Description Category Subcategory Severity 4345 Storage physical disk failure. Error Events Physical Disk Critical Table 251. Storage Power Supply Traps TrapID Description Category Subcategory Severity Storage power supply information. Error Events Power Supply Informational Storage power supply warning. Error Events Power Supply Minor Storage power supply failure.
Table 254. Storage Temperature Probe Traps(continued) TrapID Description Category Subcategory Severity Error Events Temperature Probe Minor Error Events Temperature Probe Critical Category Subcategory Severity Storage virtual disk information. Error Events Virtual Disk Informational Storage virtual disk warning. Error Events Virtual Disk Minor Storage Virtual disk failure.
Table 258. Audit License Traps(continued) TrapID Description Category SubCategory Severity License failure. Error Events License Critical Description Category SubCategory Severity PCI device audit warning. Status Events PCI Device Minor Description Category SubCategory Severity Power supply audit warning. Status Events Power Supply Minor Power supply audit failure or critical event.
Table 263. Configuration IO Virtualization Traps(continued) TrapID Description Category SubCategory Severity 10746 IO Virtualization configuration warning. Status Events IO Virtualization Minor Category SubCategory Severity Status Events PCI Device Informational Description Category SubCategory Severity Software configuration warning. Status Events Software Config Minor Software configuration failure.
4 iDRAC MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 and later versions (iDRAC7, iDRAC8 and iDRAC9). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 and later of a system. NOTE: From iDRAC7 firmware release r1.30.
NOTE: iDRAC does not support the SNMP SET operation for any data. NOTE: iDRAC7 firmware release r1.30.30 or later supports SNMP query operations (GET, GETNEXT, GETBULK) through the SNMPv3 protocol. In addition to supporting query operations through the SNMP v1 and SNMP v2c protocols, SNMP User Security Model (USM) is supported.
Table 271. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card. Syntax StringType Access Read-only Table 272. RAC Manufacturer Name racManufacturer Object ID 1.3.6.1.4.1.674.10892.5.1.1.4.0 Description This attribute defines the product manufacturer of a remote access card. Syntax StringType Access Read-only Table 273. RAC Version Name racVersion Object ID 1.3.6.1.4.1.674.
Chassis Information Group The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just one object under the Chassis Information Group. Table 277. Chassis Service Tag Name chassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.
Table 281. System Service Tag(continued) Syntax StringType Access Read-only Table 282. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 283. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system.
Table 287. System Data Center Name(continued) Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only Table 288. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 289. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.1.3.10.
Table 293. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Syntax StringType Access Read-only Table 294. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.0 Description This attribute defines the Room locator of the system. Syntax StringType Access Read-only Table 295.
Table 298. System OEM OS Version(continued) Syntax StringType Access Read-only Table 299. System Lockdown Mode Name systemLockdownMode Object ID 1.3.6.1.4.1.674.10892.5.1.3.20.0 Description This attribute defines the system Lockdown mode is enabled or disabled. Syntax SystemLockdownModeEnum Access Read-only Status Group The Status Group objects provide status information about the system and storage. Table 300. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.
Table 303. System Power State(continued) Syntax PowerStateStatusEnum Access Read-only Table 304. System Power Up Time Name systemPowerUpTime Object ID 1.3.6.1.4.1.674.10892.5.2.5.0 Description This attribute defines the power-up time of the system in seconds. Syntax Unsigned32BitRange Access Read-only Systems Details Group The Systems Details Group contains objects and tables that provide detailed information about the system in which the iDRAC resides.
Table 308. Power Unit State Settings(continued) Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.4 Description. This attribute defines the state settings of the power unit. Syntax StateSettingsFlags Access Read-only Table 309. Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.5 Description This attribute defines the redundancy status of the power unit. Syntax StatusRedundancyEnum Access Read-only Table 310.
Table 313. Power Supply Chassis Index(continued) Syntax PowerSupplyTableEntry Access Read-only Table 314. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 Description This attribute defines the index (one based) of the power supply. Syntax ObjectRange Access Read-only Table 315. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.
Table 319. Power Supply Type(continued) Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 Description This attribute defines the type of the power supply. Syntax String64 Access Read-only Table 320. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 Description This attribute defines the location of the power supply. Syntax String64 Access Read-only Table 321.
Table 324. Power Supply Configuration Error Type(continued) Access Read-only Table 325. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.13 Description This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. Syntax BooleanType Access Read-only Table 326. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.5.4.600.
Table 330. Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.2 Description This attribute defines the index (one based) of the voltage probe. Syntax ObjectRange Access Read-only Table 331. Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.3 Description This attribute defines the state capabilities of the voltage probe. Syntax StateCapabilitiesFlags Access Read-only Table 332.
Table 335. Voltage Probe Type (continued) Syntax VoltageTypeEnum Access Read-only Table 336. Voltage Probe Location Name Name voltageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.8 Description This attribute defines the location name of the voltage probe. Syntax String64 Access Read-only Table 337. Voltage Probe Upper Non Recoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.
Table 341. Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.13 Description This attribute defines the lower critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. Syntax Signed32BitRange Access Read-only Table 342. Voltage Probe Lower NonRecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.
Table 346. Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.2 Description This attribute defines the index (one based) of the amperage probe. Syntax ObjectRange Access Read-only Table 347. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.3 Description This attribute defines the state capabilities of the amperage probe. Syntax StateCapabilitiesFlags Access Read-only Table 348.
Table 351. Amperage Probe Type (continued) Description This attribute defines the type of the amperage probe. Syntax AmperageProbeTypeEnum Access Read-only Table 352. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.8 Description This attribute defines the location of the amperage probe. Syntax String64 Access Read-only Table 353.
Table 357. Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.13 Description This attribute defines the lower critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. Syntax Signed32BitRange Access Read-only Table 358. Amperage Probe Lower NonRecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.
Table 362. System Battery Index Name systemBatteryIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.2 Description This attribute defines the index (one based) of the battery. Syntax ObjectRange Access Read-only Table 363. System Battery State Capabilities Name systemBatteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.3 Description This attribute defines the state capabilities of the battery. Syntax StateCapabilitiesFlags Access Read-only Table 364.
Power Usage Table The Power usage objects provide information about the power usage in which the iDRAC resides. Table 368. Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.1 Description This attribute defines the index (one based) of the associated system chassis. Syntax ObjectRange Access Read-only Table 369. Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.
Table 373. Power Usage Entity Name(continued) Description This attribute defines the name of the entity associated with this power usage information. Syntax String64 Access Read-only Table 374. Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.7 Description This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute.
Table 378. Power Usage Peak Watts Reading Date Name(continued) Access Read-only Table 379. Power Usage Peak Amps Name powerUsagePeakAmps Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.12 Description This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute. Syntax Unsigned32BitRange Access Read-only Table 380.
Table 384. Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.17 Description This attribute defines the system power cap capabilities. Syntax PowerCapCapabilitiesFlags Access Read-only Table 385. Power Usage Power Cap Setting Name powerUsagePowerCapSetting Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.18 Description This attribute defines the system power cap setting. Syntax PowerCapSettingEnum Access Read-only Table 386.
Battery Table The objects provide information about the Battery storage group. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.1.
Table 392. Battery Predicted Capacity(continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10 Description This entry is obsolete. Use the battery Component Status or battery State instead. Syntax INTEGER Access read-only Table 393. Battery FQDD Name batteryFQDD Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 Description The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax DisplayString Access read-only Table 394.
Table 397. Controller Rebuild Rate Name controllerRebuildRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7 Description The rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary. Syntax INTEGER Access read-only Table 398. Controller FW Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8 Description The controller's current firmware version.
Table 401. Controller Component Status(continued) 4. Non-critical 5. Critical 6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 402. Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 Description Currently installed driver version for this controller on the host. Syntax DisplayString Access read-only Table 403. Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Table 406. Controller BGI Rate(continued) Description The background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant virtual disk after it is created. Syntax INTEGER Access read-only Table 407. Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Table 411. Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60 Description Indicates whether un-configured drives would be put in power save mode by the controller. Syntax BooleanType Access read-only Table 412. Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Table 416. Controller Copy Back Mode(continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 Description The current copy back mode setting for the controller. Possible values: 1. 2. 3. 4. Not one of the following. Not supported on this controller. Disks assigned as spares could revert back to spare status. Data from physical disk participating in a virtual disk could be automatically copied to the assigned hot spare in case former has a predictive failure event. 5.
Table 420. Controller Load Balance Setting(continued) 1. 2. 3. 4. Not one of the following. Not supported. Automatic load balancing is active. Load balancing is inactive. Syntax INTEGER Access read-only Table 421. Controller Max Cap Speed Name controllerMaxCapSpeed Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 Description The maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1. 2. 3. 4. 5. The speed could not be determined. 1.5 Gbps 3.0 Gbps 6.0 Gbps 12.
Table 425. Controller T10 PI Capability Name controllerT10PICapability Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80 Description Description Indicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields).Possible values: 1. Not one of the following. 2. Capable of supporting T10 PI. 3. Not capable of supporting T10 PI. Syntax INTEGER Access read-only Table 426.
Table 429. Controller Boot Mode(continued) 2. User mode: User interaction required for all boot messages (not applicable for uEFI environments). 3. Continue Boot On Error. User interaction only required for critical messages. 4. Headless Mode Continue On Error. User interaction is not required. Controller boot may halt on Error. 5. Headless Safe Mode. Controller shall boot to safe mode on critical errors. Syntax INTEGER Access read-only Table 430.
Table 432. Physical Disk Number(continued) Syntax INTEGER Access read-only Table 433. Physical Disk Name Name physicalDiskName Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 Description The physical disk's name as represented in Storage Management. Syntax DisplayString Access read-only Table 434. Physical Disk Manufacturer Name physicalDiskManufacturer Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3 Description The name of the physical disk's manufacturer.
Table 437. Physical Disk Serial No Name physicalDiskSerialNo Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 Description The physical disk's unique identification number from the manufacturer. Syntax DisplayString Access read-only Table 438. Physical Disk Revision Name physicalDiskRevision Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8 Description The firmware version of the physical disk. Syntax DisplayString Access read-only Table 439.
Table 442. Physical Disk Bus Type(continued) 1. 2. 3. 4. 5. 6. The bus type could not be determined. Small Computer System Interface (SCSI). Serial Attached SCSI (SAS). Serial Advanced Technology Attachment (SATA). Fibre channel. PCIe. Syntax INTEGER Access read-only Table 443. Physical Disk Spare State Name physicalDiskSpareState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22 Description The status of the disk as a spare. Possible values: 1. Physical disk is not a spare. 2.
Table 446. Physical Disk SAS Address(continued) Description The SAS address of the physical disk. Syntax DisplayString Access read-only Table 447. Physical Disk Negotiated Speed Name physicalDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.29 Description The data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1. 2. 3. 4. 5. 6. 7. The speed could not be determined. 1.5 Gbps 3.0 Gbps 6.0 Gbps 12.
Table 450. Physical Disk Manufacture Day(continued) Description The day of the week on which the physical disk was manufactured. Syntax DisplayString Access read-only Table 451. Physical Disk Manufacture Week Name physicalDiskManufactureWeek Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33 Description The week in which the physical disk was manufactured. Syntax DisplayString Access read-only Table 452. Physical Disk Manufacture Year Name physicalDiskManufactureYear Object ID 1.3.6.1.4.
Table 455. Physical Disk Power State(continued) 1. 2. 3. 4. Not one of the following. The physical disk is in the spun up state. The physical disk is in the spun down state. The physical disk is changing from spun down state to spun up state or vice versa. 5. The Solid State Device (SSD) is powered on. Syntax INTEGER Access read-only Table 456. Physical Disk Power State Name physicalDiskPowerState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 459. Physical Disk Form Factor(continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53 Description The form factor of the physical disk. Possible Values: 1. 2. 3. 4. The form factor could not be determined. 1.8 inch. 2.5 inch. 3.5 inch. Syntax INTEGER Access read-only Table 460. Physical Disk FQDD Name physicalDiskFQDD Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54 Description The physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
Table 463. Physical Disk Block Size In Bytes(continued) Syntax INTEGER Access read-only Table 464. Physical Disk Protocol Version Name physicalDiskProtocolVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59 Description Applicable for NVMe devices only. The NVMe protocol version supported by the device. Syntax DisplayString Access read-only Table 465. Physical Disk PCIe Negotiated Link Width Name physicalDiskPCIeNegotiatedLinkWidth Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
NOTE: This attribute is applicable for VRTX CMC only. Virtual Disk Table The objects provide information about the Virtual disk storage group. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 for the table group are attributes for checking on iDRAC.
Table 473. Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10 Description The write policy used by the controller for write operations on this virtual disk. Possible values: 1. Write Through. 2. Write Back. 3. Force Write Back. Syntax INTEGER Access read-only Table 474. Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 476. Virtual Disk Stripe Size(continued) 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 512 bytes 1 kB 2 kB 4 kB 8 kB 16 kB 32 kB 64 kB 128 kB 256 kB 512 kB 1 MB 2 MB 4 MB 8 MB 16 MB Syntax INTEGER Access read-only Table 477. Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 Description The status of the virtual disk itself without the propagation of any contained component status.Possible values: 1. 2. 3. 4. 5. 6.
Table 479. Virtual Disk Secured(continued) Access read-only Table 480. Virtual Disk Is Cache Cade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25 Description Indicates whether the virtual disk is being used as a secondary cache by the controller. Syntax BooleanType Access read-only Table 481. Virtual Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 484. Virtual Disk Available Protocols Name virtualDiskAvailableProtocols Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.32 Description List of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment. Syntax DisplayString Access read-only Table 485. Virtual Disk Media Type Name virtualDiskMediaType Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 489. Virtual Disk T10 PI Status(continued) Description Indicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1. Not one of the following. 2. Enabled. 3. Disabled. Syntax INTEGER Access read-only Table 490. Virtual Disk Block Size In Bytes Name virtualDiskBlockSizeInBytes Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 493. Virtual Disk Adapter 3 Access Policy (continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.41 Description Indicates the Access policy of the virtual disk with the virtual adapters. Possible values: 1. No Access. 2. Full Access. Syntax INTEGER Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 494. Virtual Disk Adapter 4 Access Policy Name virtualDiskAdapter4AccessPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 497. Virtual Disk Failover Controller (continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.44 Description Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. Syntax FQDDString Access read-only NOTE: This attribute is applicable for VRTX CMC only. Enclosure Table The objects provide information about the Enclosure Table group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release.
Table 500. Enclosure State(continued) Syntax INTEGER Access read-only Table 501. Enclosure Service Tag Name enclosureServiceTag Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.8 Description Enclosure identification used when consulting customer support. Syntax DisplayString Access read-only Table 502. Enclosure Asset Tag Name enclosureAssetTag Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9 Description The asset tag information for the enclosure.
Table 505. Enclosure Firmware Version(continued) Syntax DisplayString Access read-only Table 506. Enclosure SAS Address Name enclosureSASAddress Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.30 Description The SAS address of the enclosure/backplane. Syntax DisplayString Access read-only Table 507. Enclosure Drive Count Name enclosureDriveCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31 Description The number of disks present in the enclosure/backplane.
Table 511. Enclosure EMM Count(continued) Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42 Description The number of Enclosure Management Modules (EMM) present in the storage enclosure. Syntax DisplayString Access read-only Table 512. Enclosure Temp Probe Count Name enclosureTempProbeCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.43 Description The number of temperature sensing devices present in the storage enclosure. Syntax DisplayString Access read-only Table 513.
Table 517. Enclosure Display Name Name enclosureDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48 Description The enclosure/backplane's friendly FQDD as represented in Storage Management. Syntax DisplayString Access read-only Table 518. Enclosure Type Name enclosureType Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.49 Description The protocol supported by the backplane. Possible states: 1. 2. 3. 4. 5. Not one of the following or could not be determined. Not applicable (i.e.
Table 521. Enclosure Management Module State(continued) Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 Description The current state of this enclosure management module. Possible states: 1. The current state could not be determined 2. The enclosure management module is operating normally 3. The enclosure management module has encountered a hardware problem or is not responding 4. The enclosure management module is no longer connected to the enclosure or there exists a problem communicating to it 5.
Table 525. Enclosure Management Module FQDD(continued) Description The enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 526. Enclosure Management Module Display Name Name enclosureManagementModuleDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 Description The enclosure management module's friendly FQDD as represented in Storage Management.
Table 529. Enclosure Fan State(continued) 4. The fan is no longer connected to the enclosure or there exists a problem communicating to it 5. The fan is unstable Syntax INTEGER Access read-only Table 530. Enclosure Fan Speed Name enclosureFanSpeed Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11 Description Indicates the current relative speed of the fan in RPMs. Syntax INTEGER Access read-only Table 531. Enclosure Fan Component Status Name enclosureFanComponentStatus Object Id 1.3.6.1.
Enclosure Power Supply Table The objects provide information about the Enclosure Power Supply group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.
Table 538. Enclosure Power Supply Component Status(continued) Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9 Description The status of the power supply unit itself without the propagation of any contained component status. Possible values: 1. 2. 3. 4. 5. 6. Other Unknown OK Non-critical Critical Non-recoverable Syntax ObjectStatusEnum Access read-only Table 539. Enclosure Power Supply FQDD Name enclosurePowerSupplyFQDD Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.
Table 542. Enclosure Temperature Probe Name Name enclosureTemperatureProbeName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2 Description The temperature probe's name as represented in Storage Management Syntax DisplayString Access read-only Table 543. Enclosure Temperature Probe State Name enclosureTemperatureProbeState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4 Description The current state of this temperature probe. Possible states: 1.
Table 547. Enclosure Temperature Probe Max Critical Value Name enclosureTemperatureProbeMaxCriticalValue Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10 Description The maximum temperature that will force the probe into a warning state. Syntax INTEGER Access read-only Table 548. Enclosure Temperature Probe Cur Value Name enclosureTemperatureProbeCurValue Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.
iDRAC Traps The iDRAC generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC. The iDRAC generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console.
Table 554. Alert Current Status(continued) Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 555. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString Table 555. Alert System Service Tag Access Read-only Table 556. Alert System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.5.3.1.5.
Table 559. Alert Message Arguments(continued) quote of each message argument string, except the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 559. Alert Message Arguments Access Read-only Table 560. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For modular systems, the service tag of the enclosing chassis.
Table 563. Amperage Probe Traps(continued) TrapID Description Category SubCategory Severity 2178 Current sensor has detected a warning value. System Health Amperage Minor Current sensor has detected a failure value. System Health Amperage Critical Description Category SubCategory Severity Automatic system recovery (ASR) was performed.
Table 568. Processor Device Status Traps(continued) TrapID Description Category SubCategory Severity 2242 Processor device status has detected a warning. System Health Processor Minor Processor device status has detected a failure. System Health Processor Critical Description Category SubCategory Severity Processor device is absent. System Health Proc Absent Critical Description Category SubCategory Severity Fan information. System Health Fan Event Informational Fan warning.
Table 573. IO Virtualization Traps TrapID Description Category SubCategory Severity IO Virtualization failure or critical event. System Health IO Virtualization Critical Description Category SubCategory Severity Link status information. System Health Link Status Informational Link status warning. System Health Link Status Minor Link status failure or critical event. System Health Link Status Critical Description Category SubCategory Severity Memory device informational event.
Table 578. PCI Device Traps TrapID Description Category SubCategory Severity An informational event was detected for a PCI device. System Health PCI Device Informational A warning event was detected for a PCI device. System Health PCI Device Minor An error was detected for a PCI device. System Health PCI Device Critical Description Category SubCategory Severity Physical disk information. System Health Physical Disk Informational Physical disk warning.
Table 583. Power Usage Traps(continued) TrapID Description Category SubCategory Severity 2275 System performance restored. System Health Power Usage Informational System performance degraded. System Health Power Usage Minor The system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. System Health Power Usage Critical Description Category SubCategory Severity Redundancy information.
Table 587. Integrated Dual SD Module Redundancy Traps(continued) TrapID Description Category SubCategory Severity System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Informational Security warning. System Health Security Event Minor Security failure or critical event. System Health Security Event Critical Description Category SubCategory Severity System Event Log information.
Table 591. Temperature Probe Traps(continued) TrapID Description Category SubCategory Severity 2161 Temperature sensor has detected a failure value. System Health Temperature Critical Category SubCategory Severity Temperature has been above the warning or critical threshold level for a long enough period of time to be considered in a warning state.
Table 596. Voltage Probe Traps(continued) TrapID Description Category SubCategory Severity 2169 Voltage sensor has detected a failure value. System Health Voltage Critical Description Category SubCategory Severity System performance warning. System Health Performance Minor Description Category SubCategory Severity Unable to communicate with internal iDRAC memory.
Table 602. Enclosure Traps TrapID Description Category SubCategory Severity Enclosure information. Storage Storage Enclosr Informational Enclosure warning. Storage Storage Enclosr Minor Enclosure failure. Storage Storage Enclosr Critical Description Category SubCategory Severity Fan information. Storage Fan Event Informational Fan warning. Storage Fan Event Minor Fan failure. Storage Fan Event Critical Category SubCategory Severity Physical disk information.
Table 606. Security Event Traps(continued) TrapID Description Category SubCategory Severity 4434 Storage Security warning. Storage Security Event Minor Storage Security failure or critical event. Storage Security Event Critical Category SubCategory Severity Storage Management information. There Storage is no global status change associated with this trap. Storage Informational Storage Management has detected a device independent warning condition.
Table 610. Update Traps TrapID Description Category SubCategory Severity Update job information. Updates Updates Informational Category SubCategory Severity Updates Software Change Minor Updates Job Information 6211 Table 611. Software Change Traps TrapID Description Software Change Update Warning 6314 Software change update warning. Audit Trap Group The Audit Trap Group contains traps that fall under the Audit event category of iDRAC.
Table 616. License Traps TrapID Description Category SubCategory Severity License information. Audit Licensing Informational License warning. Audit Licensing Minor License failure. Audit Licensing Critical Description Category SubCategory Severity PCI device audit warning. Audit PCI Device Minor Description Category SubCategory Severity Power supply audit warning. Audit Power Supply Minor Power supply audit failure or critical event.
Table 621. Auto Discovery Traps TrapID Description Category SubCategory Severity Auto discovery information. Configuration Auto Discovery Informational Category SubCategory Severity Configuration IOID Informational Network configuration warning. Configuration IOID Minor Description Category SubCategory Severity Configuration IP Address Informational Category SubCategory Severity Job control configuration information.
iDRAC Memory Unresponsive Trap The iDRAC memory unresponsive trap contains traps that fall under the iDRAC Memory Unresponsive event category of iDRAC. The notifications which an SNMP v2 entity is required to implement. Table 629. Update Traps TrapID Description Category SubCategory Severity Unable to communicate with internal iDRAC memory.