Dell EMC OpenManage Message Reference Guide Version 9.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction.................................................................................................................................................. 16 New in this release............................................................................................................................................................16 Alert Message Change History.....................................................................................................................................
Event ID — 1053........................................................................................................................................................ 31 Event ID — 1054........................................................................................................................................................ 31 Event ID — 1055.......................................................................................................................................................
Memory Device Messages............................................................................................................................................. 46 Event ID — 1400....................................................................................................................................................... 46 Event ID — 1401........................................................................................................................................................
Event ID — 1706........................................................................................................................................................ 57 Secure Digital SD Card Device Messages.....................................................................................................................57 Event ID — 1750........................................................................................................................................................
Event ID — 2089.......................................................................................................................................................75 Event ID — 2090.......................................................................................................................................................76 Event ID — 2091........................................................................................................................................................
Event ID — 2141.........................................................................................................................................................93 Event ID — 2142........................................................................................................................................................94 Event ID — 2143........................................................................................................................................................
Event ID — 2186.......................................................................................................................................................110 Event ID — 2187....................................................................................................................................................... 110 Event ID — 2188........................................................................................................................................................
Event ID — 2233......................................................................................................................................................126 Event ID — 2234......................................................................................................................................................127 Event ID — 2235......................................................................................................................................................
Event ID — 2280..................................................................................................................................................... 143 Event ID — 2281...................................................................................................................................................... 143 Event ID — 2282......................................................................................................................................................
Event ID — 2327......................................................................................................................................................160 Event ID — 2328...................................................................................................................................................... 161 Event ID — 2329......................................................................................................................................................
Event ID — 2375...................................................................................................................................................... 177 Event ID — 2376...................................................................................................................................................... 178 Event ID — 2377......................................................................................................................................................
Event ID — 2433......................................................................................................................................................194 Event ID — 2434......................................................................................................................................................194 Event ID — 2435.....................................................................................................................................................
Event ID — 2906..................................................................................................................................................... 210 Event ID — 2907......................................................................................................................................................210 Event ID — 2908.....................................................................................................................................................
1 Introduction OpenManage Server Administrator generates event messages stored primarily in the operating system or Server Administrator event logs and sometimes in Simple Network Management Protocol (SNMP) traps. This document describes the event messages that are created by Server Administrator version and displayed in the Server Administrator alert log. Server Administrator creates events in response to sensor status changes and other monitored parameters.
Storage Management 4.4 Server Administrator 7.4.0 New Alerts 1015, 1016 Deleted Alerts 1250, 1253, 1255, 1350, 1355, 1450, 1451, 1452, 1453, 1454, 1455, 1500, 1501, 1502, 1503, 1504, 1505, 1600, 1605 Modified Alerts None Storage Management 4.3 Product Versions to which changes apply Storage Management 4.3.0 Server Administrator 7.3.
Storage Management 4.4 Deleted Alerts None Modified Alerts 2388, 2347, 2081 Storage Management 3.4 Product Versions to which changes apply Storage Management 3.4.0 Server Administrator 6.4.0 New Alerts 2405, 2406, 2407, 2408, 2409, 2410, 2411, 2412, 2413, 2414, 2415, 2416, 2417, 2418 NOTE: The CacheCade feature is available from calendar year 2011. Deleted Alerts None Modified Alerts None Storage Management 3.3 Product Versions to which changes apply Storage Management 3.3.
Table 2. Understanding Event Messages Icon Alert Severity Component Status OK /Normal / Informational An event that describes the successful operation of a unit. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation, such as power supply or a sensor reading returning to normal. Warning / Non-critical An event that is not necessarily significant, but may indicate a possible future problem.
Type: Information Date and Time: Mon Oct 21 10:38:00 2002 Computer: Description: Server Administrator starting Data: Bytes in Hex Viewing Alerts and Event Messages An event log is used to record information about important events. Server Administrator generates alerts that are added to the operating system event log and to the Server Administrator alert log. To view these alerts in Server Administrator: 1 Select the System object in the tree view. 2 Select the Logs tab.
Viewing Events in Red Hat Enterprise Linux and SUSE Linux Enterprise Server 1 Log in as root. 2 Use a text editor such as vi or emacs to view the file named /var/log/messages. The following example shows the Red Hat Enterprise Linux and SUSE Linux Enterprise Server message log, /var/log/messages. The text in boldface type indicates the message text. NOTE: These messages are typically displayed as one long line.
Understanding the Event Description Table below lists in alphabetical order each line item that may appear in the event description.
Description Line Item Device location: Explanation Specifies the location of the device in the specified chassis, for example: Device location: Memory Card A Description Line Item Discrete current state: Explanation Specifies the state of the current sensor, for example: Discrete current state: Good Description Line Item Discrete temperature state: Explanation Specifies the state of the temperature sensor, for example: Discrete temperature state: Good Descri
Explanation Specifies a list of possible causes for the memory module event, for example: Possible memory module event cause: Single bit warning error rate exceeded Single bit error logging disabled Description Line Item Power Supply type: Explanation Specifies the type of power supply, for example: Power Supply type: VRM Description Line Item Previous redundancy state was: Explanation Specifies the status of the previous redundancy message, for example: Previous redu
2 Server Management Messages The following tables lists in numerical order each event ID and its corresponding description, along with its severity and cause. NOTE: For corrective actions, see the appropriate documentation.
Cause The log was full, copied to backup, and cleared. Event ID — 1000 Description Server Administrator starting Severity Information Cause Server Administrator is beginning to initialize. Event ID — 1001 Description Server Administrator startup complete Severity Information Cause Server Administrator completed initialization.
Event ID — 1005 Description SMBIOS data is absent Severity Error Cause The system does not contain the required systems management BIOS version 2.2 or higher, or the BIOS is corrupted. Event ID — 1006 Description Automatic System Recovery (ASR) action was performed Action performed was: Date and time of action: Severity Error Cause This message is generated when an automatic system recovery action is performed due to a hung operating system.
Event ID — 1011 Description RCI table is corrupt Severity Error Cause This message is generated when the BIOS Remote Configuration Interface (RCI) table is corrupted or cannot be read by the systems management software. Event ID — 1012 Description IPMI Status Interface: , Severity Information Cause This message is generated to indicate the Intelligent Platform Management Interface (IPMI) status of the system.
Event ID — 1016 Description Server Based Management Mode is disabled Severity Information Cause This event is generated when the server-based management mode is disabled. Event ID — 1017 Description Server Administrator SNMP agent key is missing Severity Warning Cause This event is generated when the operating system is upgraded. Action Server Administrator repair operation is required to recover the missing SNMP agent key.
Temperature Sensor Messages The temperature sensors listed help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperature sensor messages use more variables: sensor location, chassis location, previous state, and temperature sensor value or state.
Chassis location: Previous state was: If sensor type is not discrete: Temperature sensor value (in degrees Celsius): If sensor type is discrete: Discrete temperature state: Severity Information Cause A temperature sensor on the backplane board, system board, or drive carrier in the specified system returned to a valid range after crossing a failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
If sensor type is discrete: Discrete temperature state: Severity Error Cause A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
Event ID — 1101 Description Fan sensor value unknown Sensor location: Chassis location: Previous state was: Fan sensor value: Severity Error Cause A fan sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal fan sensor value information is provided.
Previous state was: Fan sensor value: Severity Error Cause A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value information is provided.
Event ID — 1151 Description Voltage sensor value unknown Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Voltage sensor value (in Volts): If sensor type is discrete: Discrete voltage state: Severity Warning Cause A voltage sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal voltage sensor value are provided.
Voltage sensor value (in Volts): If sensor type is discrete: Discrete voltage state: Severity Warning Cause A voltage sensor in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and voltage sensor value information is provided.
Current Sensor Messages The current sensors listed measure the amount of current (in amperes) that is traversing critical components. Current sensor messages provide status and warning information for current sensors in a particular chassis.
Event ID — 1202 Description Current sensor returned to a normal value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Current sensor value (in Amps): OR Current sensor value (in Watts): If sensor type is discrete: Discrete voltage state: Severity Information Cause A current sensor in the specified system returned to a valid range after crossing a failure threshold.
Event ID — 1204 Description Current sensor detected a failure value Sensor location: Chassis location: Previous state was: If sensor type is not discrete: Current sensor value (in Amps): OR Current sensor value (in Watts): If sensor type is discrete: Discrete voltage state: Severity Error Cause A current sensor in the specified system exceeded its failure threshold.
Event ID — 1251 Description Chassis intrusion sensor value unknown Sensor location: Chassis location: Previous state was: Chassis intrusion state: Severity Warning Cause A chassis intrusion sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and chassis intrusion state are provided.
Drive bay Intrusion Messages The drive bay intrusion messages listed are a security measure. Drive bay intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis.
Cause A Drive Bay intrusion has been detected for extended period of time the system cover was opened while the system was operating. The sensor location, chassis location, previous state, and chassis intrusion state information is provided. Redundancy Unit Messages Redundancy means that a system chassis has more than one of certain critical components.
Severity Information Cause A redundancy sensor in the specified system detected that a unit was not redundant. The redundancy location, chassis location, previous redundancy state, and the number of devices required for full redundancy information is provided.
Event ID — 1306 Description Redundancy lost Redundancy unit: Chassis location: Previous redundancy state was: Severity Error Cause A redundancy sensor in the specified system detected that one of the components in the redundant unit has been disconnected, has failed, or is not present. The redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy are provided.
If in configuration error state: Configuration error type: Severity Information Cause A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, power supply type, additional power supply status, and configuration error type information are provided.
Memory Device Messages The memory device messages listed provides status and warning information for memory modules present in a particular system. Memory devices determine health status by monitoring the ECC memory correction rate and the type of memory events that have occurred. NOTE: A critical status does not always indicate a system failure or loss of data. In some instances, the system has exceeded the ECC correction rate.
Event ID — 1403 Description Memory device status is Memory device location: Possible memory module event cause: Severity Warning Cause A memory device correction rate exceeded an acceptable value. The memory device status and possible memory module event cause information is provided.
Event ID — 1426 Description The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is about to reach the end of supported life duration. Severity Warning Cause During the next scheduled maintenance, replace the Non-Volatile Dual In-line Memory Module (NVDIMM) device. For more information about the usage of NVDIMMs, see the system Owner's Manual on the support site.
Event ID — 1430 Description An unsupported Non-Volatile Dual In-line Memory Module (NVDIMM) device is of unsupported configuration and unable to operate as currently configured. Severity Critical Cause Review the memory configuration and make sure the configuration is as per memory rules defined in the system Owner's Manual on the support site. Event ID — 1431 Description The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is not responding.
Event ID — 1434 Description The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, has reached the end of supported life duration and is placed in write-protect mode. Severity Critical Cause Replace the Non-Volatile Dual In-line Memory Module (NVDIMM) device. For information about removing and reinstalling the NVDIMM, see the system Owner's Manual on the support site.
Cause A Critical event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device. Event ID — 1438 Description Memory device status is Memory device location: Possible memory module event cause: Severity Informational Cause An Informational event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device. Hardware Log Sensor Messages The hardware logs provide hardware status messages to systems management software.
Log type: Severity Information Cause The hardware log on the specified system is no longer near or at its capacity, usually as the result of clearing the log. The log type information is provided. Event ID — 1553 Description Log size is near capacity Log type: Severity Warning Cause The size of a hardware log on the specified system is near or at the capacity of the hardware log. The log type information is provided.
Previous state was: Processor sensor status: Severity Warning Cause A processor sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state and processor sensor status information is provided.
Severity Error Cause A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip. The sensor location, chassis location, previous state and processor sensor status are provided. Pluggable Device Messages The pluggable device messages listed provides status and error information when some devices, such as memory cards, are added or removed.
Event ID — 1653 Description Device configuration error detected Device location: Chassis Location: Additional details: Severity Error Cause A configuration error was detected for a pluggable device in the specified system. The device may have been added to the system incorrectly. Battery Sensor Messages The battery sensors monitor how well a battery is functioning.
Event ID — 1702 Description Battery sensor returned to a normal value Sensor location: Chassis Location: Previous state was: Battery sensor status: Severity Information Cause A battery sensor in the specified system detected that a battery transitioned back to a normal state. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Chassis Location: Previous state was: Battery sensor status: Severity Error Cause A battery sensor in the specified system could not retrieve a value. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Event ID — 1751 Description SD card device sensor value unknown Sensor location: Chassis Location: Previous state was: SD card device type: SD card state: Severity Information Cause An SD card device sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and SD card device type information is provided.
Cause An SD card device sensor in the specified system detected a warning condition. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
3 Storage Management Message Reference The Server Administrator Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, enclosures, physical disks, and virtual disks. Topics: • Alert Monitoring and Logging • Alert Message Format with Substitution Variables • Alert Descriptions and Corrective Actions Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging.
Table 3.
Storage Object Message Variables For example, 2122 Redundancy degraded: Power Supply 1, Controller 1, Connector 0, Target ID 6 SAS Power Supply Message Format: Power Supply X Controller A, Connector B, Enclosure C For example, 2312 A power supply in the enclosure has an AC failure: Power Supply 1, Controller 1, Connector 0, Enclosure 2 SCSI Temperature Probe Message Format: Temperature Probe X Controller A, Connector B, Target ID C where C is the SCSI ID number of the EMM managing the temperature probe
Event ID — 2048 Description Device failed. Severity Critical / Failure / Error Cause and Action Cause: A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency. Action: Replace the failed component. You can identify which disk has failed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the failed component.
Action: Perform a rescan. You can also select the offline disk and perform a Make Online operation. Related Alert Information Clear Alert Number: 2158 Related Alert Number: 2099, 2196 Local Response Agent (LRA) Number: 2070 SNMP Trap Numbers 903 Event ID — 2051 Description Physical disk degraded. Severity Warning / Non-critical Cause and Action Cause: A physical disk has reported an error condition and may be degraded.
Event ID — 2053 Description Virtual disk created. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2054 Description Virtual disk deleted. Severity Informational Cause and Action Cause: A virtual disk has been deleted.
SNMP Trap Numbers 1201 Event ID — 2056 Description Virtual disk failed. Severity Critical / Failure / Error Cause and Action Cause: One or more physical disks included in the virtual disk have failed. If the virtual disk is non-redundant (does not use mirrored or parity data), then the failure of a single physical disk can cause the virtual disk to fail. If the virtual disk is redundant, then more physical disks have failed than can be rebuilt using mirrored or parity information.
Event ID — 2058 Description Virtual disk check consistency started. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2059 Description Virtual disk format started. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
SNMP Trap Numbers 1201 Event ID — 2061 Description Virtual disk initialization started. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: 2088 Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2062 Description Physical disk initialization started.
Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2064 Description Virtual disk rebuild started. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: 2091 Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2065 Description Physical disk rebuild started.
Action: If the physical disk failed, then replace the physical disk. You can identify which disk failed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the disk. The consistency check can take a long time. The time it takes depends on the size of the physical disk or the virtual disk.
Event ID — 2075 Description Copy of data completed from physical disk % 2 to physical disk % 1. Severity OK / Normal / Informational Cause and Action Cause: This alert is provided for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: 2060 Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2076 Description Virtual disk Check Consistency failed.
Local Response Agent (LRA) Number: 2081 SNMP Trap Numbers 1204 Event ID — 2079 Description Virtual disk initialization failed. Severity Critical / Failure / Error Cause and Action Cause: A physical disk included in the virtual disk has failed or a user has cancelled the initialization.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that displays a red X in the status field. If the physical disk is part of a redundant array, then rebuild the physical disk. When finished, restart the reconfiguration. Software RAID: Related Alert Information • Perform a backup with the Verify option. • If the file backup fails, try to restore the failed file from a previous backup.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that has a red X for its status. Rebuild the virtual disk rebuild. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2071 SNMP Trap Numbers 904 Event ID — 2085 Description Virtual disk check consistency completed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: 2060 Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2088 Description Virtual disk initialization completed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Event ID — 2090 Description Virtual disk reconfiguration completed Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: Alert 2090 is a clear alert for alert 2063. Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2091 Description Virtual disk rebuild completed.
SNMP Trap Numbers 901 Event ID — 2094 Description Predictive Failure reported. Severity Warning / Non-critical Cause and Action Cause: The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the health of the disk based on indications such as the number of write operations that have been performed on the disk. Action: Replace the physical disk.
Event ID — 2098 Description Global hot spare assigned. Severity OK / Normal / Informational Cause and Action Cause: A user has assigned a physical disk as a global hot spare. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: 2277 Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2099 Description Global hot spare unassigned.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.
Event ID — 2103 Description Temperature dropped below the minimum failure threshold. Severity Critical / Failure / Error Cause and Action Cause: The physical disk enclosure is too cool. Action: Check if the thermostat setting is too low and if the room temperature is too cool. Related Alert Information Clear Alert Number: None Related Alert Number: 2112 Local Response Agent (LRA) Number: 2091 SNMP Trap Numbers 1054 Event ID — 2104 Description Controller battery is reconditioning.
SNMP Trap Numbers 1151 Event ID — 2106 Description SMART FPT exceeded. Severity Warning / Non-critical Cause and Action Cause: A disk on the specified controller has received a SMART alert (predictive failure) indicating that the disk is likely to fail in the near future. Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Severity Warning / Non-critical Cause and Action Cause: A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.
Severity Warning / Non-critical Cause and Action Cause: A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a nonredundant virtual disk, then back up the data before replacing the disk. CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.
Local Response Agent (LRA) Number: 2091 SNMP Trap Numbers 854 Event ID — 2114 Description A consistency check on a virtual disk has been paused (suspended). Severity OK / Normal / Informational Cause and Action Cause: The check consistency operation on a virtual disk was paused by a user. Action: To resume the check consistency operation, right-click the virtual disk in the tree view and select Resume Check Consistency.
although the mirror is no longer intact. The updates to the data are no longer copied to the mirror. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2117 Description A mirrored virtual disk has been unmirrored. Severity OK / Normal / Informational Cause and Action Cause: A user has caused a mirrored virtual disk to be unmirrored.
Event ID — 2120 Description Enclosure firmware mismatch. Severity Warning / Non-critical Cause and Action Cause: The firmware on the EMM is not the same version. It is required that both modules have the same version of the firmware. This alert may be caused when a user attempts to insert an EMM module that has a different firmware version than an existing module. Action: Download the same version of the firmware to both EMM modules.
Action: Identify and replace the failed component. To identify the failed component, select the enclosure in the tree view and click the Health subtab. Any failed component is identified with a red X on the enclosure’s Health subtab. Alternatively, you can select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a Failed or Degraded component.
Severity OK / Normal / Informational Cause and Action Cause: Data redundancy has been restored to a virtual disk or an enclosure that previously suffered a loss of redundancy. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: Alert 2124 is a clear alert for alerts 2122 and 2123.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 903 Event ID — 2127 Description Background initialization (BGI) started. Severity OK / Normal / Informational Cause and Action Cause: BGI of a virtual disk has started. This alert is for informational purposes.
Action: None Related Alert Information Clear Alert Number: None Related Alert Number: 2340 Local Response Agent (LRA) Number: 2081 SNMP Trap Numbers 1204 Event ID — 2130 Description BGI completed. Severity OK / Normal / Informational Cause and Action Cause: BGI of a virtual disk has completed. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: Alert 2130 is a clear alert for alert 2127.
Severity Warning / Non-critical Cause and Action Cause: The controller driver is not a supported version. Action: Install a supported version of the driver. If you do not have a supported driver version available, you can check with your support provider for information on how to obtain the most current driver.
Event ID — 2137 Description Communication time-out. Severity Warning / Non-critical Cause and Action Cause: The controller is unable to communicate with an enclosure. There are several reasons why communication may be lost. For example, there may be a bad or loose cable. An unusual amount of I/O may also interrupt communication with the enclosure. In addition, communication loss may be caused by software, hardware, or firmware problems, bad or failed power supplies, and enclosure shutdown.
Cause and Action Cause: A user has disabled the enclosure alarm. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 851 Event ID — 2140 Description Dead disk segments restored. Severity OK / Normal / Informational Cause and Action Cause: Disk space that was formerly “dead” or inaccessible to a redundant virtual disk has been restored. This alert is for informational purposes.
Event ID — 2142 Description Controller rebuild rate has changed. Severity OK / Normal / Informational Cause and Action Cause: A user has changed the controller rebuild rate. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2143 Description Controller alarm enabled.
SNMP Trap Numbers 751 Event ID — 2145 Description Controller battery low. Severity Warning / Non-critical Cause and Action Cause: The controller battery charge is low. Action: Recondition the battery. See the online help for more information. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2100 SNMP Trap Numbers 1153 Event ID — 2146 Description Bad block replacement error.
Local Response Agent (LRA) Number: 2060 SNMP Trap Numbers 753 Event ID — 2148 Description Bad block medium error. Severity Warning / Non-critical Cause and Action Cause: A portion of a physical disk is damaged. Action: See the Server Administrator Storage Management online help for more information.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2060 SNMP Trap Numbers 753 Event ID — 2151 Description Enclosure asset tag changed Severity OK / Normal / Informational Cause and Action Cause: A user has changed the enclosure asset tag. This alert is for informational purposes.
Cause and Action Cause: An enclosure service tag was changed. In most circumstances, this service tag should only be changed by your service provider. Action: Ensure that the tag was changed under authorized circumstances. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 851 Event ID — 2154 Description Maximum temperature probe warning threshold value changed.
Event ID — 2156 Description Controller alarm has been tested. Severity OK / Normal / Informational Cause and Action Cause: The controller alarm test has run successfully. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2157 Description Controller configuration has been reset.
SNMP Trap Numbers 901 Event ID — 2159 Description Virtual disk renamed. Severity OK / Normal / Informational Cause and Action Cause: A user has renamed a virtual disk. When renaming a virtual disk on a PERC 4/SC, 4/DC, 4e/DC, 4/Di, CERC ATA100/4ch, PERC 5/E, PERC 5/i or SAS 5/iR controller, this alert displays the new virtual disk name. On the PERC 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, and CERC ATA 100/4ch controllers, this alert displays the original virtual disk name.
Cause and Action Cause: A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk may have been unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares that have been used to rebuild data. Once data is rebuilt onto the hot spare, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare.
Local Response Agent (LRA) Number: 2071 SNMP Trap Numbers 904 Event ID — 2164 Description See the Readme file for a list of validated controller driver versions. Severity OK / Normal / Informational Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller drivers. This alert is for informational purposes. Action: See the Readme file for driver and firmware requirements.
Event ID — 2166 Description The RAID controller firmware and driver validation was not performed. The configuration file is out of date, missing the required information, or not properly formatted to complete the comparison. Severity Warning / Non-critical Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller firmware and drivers.
Cause and Action Cause: The version of the driver does not meet the minimum requirements. Storage Management may not be able to display the storage or perform storage management functions until you have updated the system to meet the minimum requirements. Action: See the Readme file for the validated driver version. Update the system to meet the minimum requirements and then reinstall Storage Management.
Event ID — 2171 Description The controller battery temperature is above normal. Severity Warning / Non-critical Cause and Action Cause: The battery may be recharging, the room temperature may be too hot, or the fan in the system may be degraded or failed. Action: If this alert was generated due to a battery recharge, the situation is corrected when the recharge is complete. You should also check if the room temperature is normal and that the system components are functioning properly.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2090 SNMP Trap Numbers 853 Event ID — 2174 Description The controller battery has been removed. Severity Warning / Non-critical Cause and Action Cause: The controller cannot communicate with the battery. The battery may be removed, or the contact point between the controller and the battery may be burnt or corroded. Action: Replace the battery if it has been removed.
Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: 2177 Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1151 Event ID — 2177 Description The controller battery Learn cycle has completed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Event ID — 2179 Description The controller battery Learn cycle has been postponed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1151 Event ID — 2180 Description The controller battery Learn cycle starts in % 1 days.
Local Response Agent (LRA) Number: None SNMP Trap Numbers 1151 Event ID — 2182 Description An invalid SAS configuration has been detected. Severity Critical / Failure / Error Cause and Action Cause: The controller and attached enclosures are not cabled correctly. Action: See the hardware documentation for information on correct cabling configurations.
Related Alert Information Clear Alert Number: None Related Alert Number: 2060 Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2185 Description Physical disk Replace Member Operation stopped for spare. Severity Warning / Non-critical Cause and Action Cause: This alert is provided for informational purposes.
Cause and Action Cause: The system memory is malfunctioning. Action: Contact technical support to replace the controller memory. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2060 SNMP Trap Numbers 753 Event ID — 2188 Description The controller write policy has been changed to Write Through. Severity Warning Cause and Action Cause: The controller battery is unable to maintain cached data for the required period of time.
Event ID — 2190 Description The controller has detected a hot-add of an enclosure. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2191 Description Multiple enclosures are attached to the controller. This is an unsupported configuration.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1203 Event ID — 2193 Description The virtual disk reconfiguration has resumed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Action: None Related Alert Information Clear Alert Number: 2196 Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2196 Description Dedicated hot spare unassigned. Physical disk % 1 Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 903 Event ID — 2199 Description The virtual disk cache policy has changed. Severity Informational Cause and Action Cause: User has provided invalid input for the chosen operation.
Severity Warning/ Non-critical Cause and Action Cause: The controller is not able to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable. Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.
SNMP Trap Numbers 903 Event ID — 2204 Description A dedicated hot spare has been removed. Severity OK / Normal / Informational Cause and Action Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable. Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.
Action: Add a SAS disk that is large enough to be used as the hot spare and assign it as a hot spare. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2070 SNMP Trap Numbers 903 Event ID — 2207 Description The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks. Severity Warning / Non-critical Cause and Action Cause: The only physical disk available to be assigned as a hot spare is using SAS technology.
Event ID — 2211 Description The physical disk is not supported. Severity Warning / Non-critical Cause and Action Cause: The physical disk may not have a supported version of the firmware or the disk may not be supported by your service provider. Action: If the disk is supported, update the firmware to a supported version. If the disk is not supported by your service provider, replace the disk with one that is supported.
Local Response Agent (LRA) Number: 2100 SNMP Trap Numbers 1153 Event ID — 2214 Description Battery charge in progress. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1151 Event ID — 2215 Description Battery charge process interrupted.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1151 Event ID — 2217 Description The battery learn mode has changed to warn. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Cause and Action Cause: This alert is for informational purposes. Action: Change at least one controller property and run the command again. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2220 Description Replace Member Operation, Auto Replace Member Operation on Predictive Failure and Loadbalance changed.
Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: Change at least one controller property and run the command again. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2223 Description Abort Check Consistency on Error, Replace Member Operation and Loadbalance changed.
Event ID — 2225 Description Abort Check Consistency on Error and Load balance changed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: Change at least one controller property and run the command again. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2226 Description Load balance changed.
SNMP Trap Numbers 751 Event ID — 2228 Description Replace Member Operation and Auto Replace Member Operation on Predictive Failure changed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: Change at least one controller property and run the command again.
Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2231 Description Replace Member Operation and Abort Check Consistency on Error changed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: Change at least one controller property and run the command again.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2234 Description The Patrol Read rate has changed. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2237 Description Abort Check Consistency on Error modified. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: Change at least one controller property and run the command again.
Cause and Action Cause: The user has attempted to clear a foreign configuration. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2240 Description A foreign configuration has been imported. Severity OK / Normal / Informational Cause and Action Cause: The user has attempted to import a foreign configuration.
Severity OK / Normal / Informational Cause and Action Cause: The controller has started the Patrol Read operation. This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: 2243 Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2243 Description The Patrol Read operation has stopped. Severity OK / Normal / Informational Cause and Action Cause: The controller has stopped the Patrol Read operation.
Event ID — 2245 Description A virtual disk blink has ceased. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2246 Description Warning / Non-critical Severity OK / Normal / Informational Cause and Action Cause: The temperature of the battery is high.
SNMP Trap Numbers 1151 Event ID — 2248 Description The controller battery is executing a Learn cycle. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1151 Event ID — 2249 Description The physical disk Clear operation has started.
Local Response Agent (LRA) Number: None SNMP Trap Numbers 753 Event ID — 2251 Description The physical disk blink has initiated. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2252 Description The physical disk blink has ceased.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2254 Description The Clear operation has cancelled. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 753 Event ID — 2258 Description Controller has preserved cache. Severity Warning /Non-critical Cause and Action Cause: I/O interrupted for a virtual disk which is connected to the controller. Action: Check for foreign configuration and import if any. Check for cable fault. Recover any virtual disk lost by the controller.
Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 851 Event ID — 2261 Description A global rescan has initiated. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Event ID — 2263 Description SMART thermal shutdown is disabled. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 101 Event ID — 2264 Description A device is missing. Severity Warning / Non-critical Cause and Action Cause: The controller cannot communicate with a device.
Related Alert Information Clear Alert Number: None Related Alert Number: 2048, 2050 Local Response Agent (LRA) Number: 2050, 2060, 2070, 2080, 2090, 2100 SNMP Trap Numbers 753, 803, 853, 903, 953, 1003, 1053, 1103, 1153, 1203 Event ID — 2266 Description Controller log file entry: %1 Severity OK / Normal / Informational Cause and Action Cause: The %1 indicates a substitution variable.
Event ID — 2268 Description %1, Storage Management has lost communication with the controller. An immediate reboot is strongly recommended to avoid further problems. If the reboot does not restore communication, then contact technical support for more information. Severity Critical / Failure / Error Cause and Action Cause: Storage Management has lost communication with a controller. This may occur if the controller driver or firmware is experiencing a problem. The %1 indicates a substitution variable.
Action: Verify that the disk is present and not in a Failed state. Make sure the cables are attached securely. See the online help for more information on checking the cables. Restart the Clear task. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2071 SNMP Trap Numbers 904 Event ID — 2271 Description The Patrol Read encountered a media error.
Event ID — 2273 Description A block on the physical disk has been punctured by the controller. Severity Critical / Failure / Error Cause and Action Cause: The controller encountered an unrecoverable medium error when attempting to read a block on the physical disk and marked that block as invalid. If the error was encountered on a source physical disk during a rebuild or reconfigure operation, it also punctures the corresponding block on the target physical disk.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2070 SNMP Trap Numbers 903 Event ID — 2277 Description The global hot spare is too small. Severity Warning / Non-critical Cause and Action Cause: The global hot spare is not large enough to protect all virtual disks that reside on the controller. Action: Assign a larger disk as the global hot spare.
Event ID — 2279 Description The controller battery charge level is operating within normal limits. Severity OK / Normal / Informational Cause and Action Cause: This alert indicates that the battery is recharging during the battery Learn cycle. This alert is provided for informational purposes.
Related Alert Information Clear Alert Number: None Related Alert Number: 2127 Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2282 Description Hot spare SMART polling failed. Severity Critical / Failure / Error Cause and Action Cause: The controller firmware attempted a SMART polling on the hot spare but was unable to complete it. The controller has lost communication with the hot spare. Action: Check the health of the disk assigned as a hot spare.
Event ID — 2284 Description A redundant path has been restored. Severity OK / Normal / Informational Cause and Action Cause: This alert is provided for informational purposes. Action: None Related Alert Information Clear Alert Number: Alert 2284 is a clear alert for alert 2283. Related Alert Number: None Local Response Agent (LRA) Number: 2071 SNMP Trap Numbers 901 Event ID — 2285 Description A disk media error was corrected during recovery.
SNMP Trap Numbers 1151 Event ID — 2287 Description Protection policy has been changed. Severity OK / Normal / Informational Cause and Action Cause: A new protection policy has been created / existing protection policy has been modified. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: 2384 Local Response Agent (LRA) Number: None SNMP Trap Numbers 101 Event ID — 2288 Description The patrol read has resumed.
Action: Replace the dual in-line memory module (DIMM). The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM. You may need to restore data from backup. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2061 SNMP Trap Numbers 754 Event ID — 2290 Description Single-bit ECC error on controller DIMM.
Event ID — 2292 Description Communication with the enclosure has been lost. Severity Critical / Failure / Error Cause and Action Cause: The controller has lost communication with an EMM. The cables may be loose or defective. Action: Make sure the cables are attached securely. Reboot the system. Related Alert Information Clear Alert Number: 2162 Related Alert Number: None Local Response Agent (LRA) Number: 2091 SNMP Trap Numbers 854 Event ID — 2293 Description The EMM has failed.
SNMP Trap Numbers 851 Event ID — 2295 Description A device has been removed. Severity Critical / Failure / Error Cause and Action Cause: A device has been removed and the system is no longer functioning in optimal condition. Action: Replace the device. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2091 SNMP Trap Numbers 854 Event ID — 2296 Description An EMM has been inserted.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2091 SNMP Trap Numbers 854, 954 Event ID — 2298 Description The enclosure has a bad sensor %1. Severity Warning / Non-critical Cause and Action Cause: The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. The % indicates a substitution variable.
Event ID — 2300 Description The enclosure is unstable. Severity Critical / Failure / Error Cause and Action Cause: The controller is not receiving a consistent response from the enclosure. There could be a firmware problem or an invalid cabling configuration. If the cables are too long, they degrade the signal. Action: Power down all enclosures attached to the system and reboot the system. If the problem persists, upgrade the firmware to the latest supported version.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2091 SNMP Trap Numbers 854 Event ID — 2303 Description The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that is being rebuilt. The new physical disk must also use the same technology (for example, SAS or SATA) as the disk being rebuilt. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run the Rebuild task. See the Server Administrator Storage Management User’s Guide for more information.
SNMP Trap Numbers 904 Event ID — 2309 Description A physical disk is incompatible. Severity Warning / Non-critical Cause and Action Cause: You have attempted to replace a disk with another disk that is using an incompatible technology. For example, you may have replaced one side of a mirror with a SAS disk when the other side of the mirror is using SATA technology. Action: See the hardware documentation for information on replacing disks.
firmware version than an existing module. The %1 and %2 indicate a substitution variable. The text for these substitution variables is displayed with the alert in the alert log and can vary depending on the situation. Action: Upgrade to the same version of the firmware on both EMM modules.
Event ID — 2314 Description The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible. Severity Critical / Failure / Error Cause and Action Cause: Storage Management is unable to monitor or manage SAS devices. Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware.
Action: See the documentation for the utility that ran the diagnostics for more information Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2061 SNMP Trap Numbers 754 Event ID — 2318 Description Problems with the battery or the battery charger have been detected. The battery health is poor. Severity Warning / Non-critical Cause and Action Cause: The battery or the battery charger is not functioning properly.
Severity Critical / Failure / Error Cause and Action Cause: The DIMM is malfunctioning. Data loss or data corruption may be imminent. Action: Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM or contact technical support.
SNMP Trap Numbers 1001 Event ID — 2323 Description The power supply is switched on. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322. Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1001 Event ID — 2324 Description The AC power supply cable has been removed.
Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1001 Event ID — 2326 Description A foreign configuration has been detected. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. The controller has physical disks that were moved from another controller. These physical disks contain virtual disks that were created on the other controller.
Event ID — 2328 Description The NVRAM has corrupt data. Severity Warning / Non-critical Cause and Action Cause: The NVRAM has corrupt data. The controller is unable to correct the situation. Action: Replace the controller.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2331 Description A bad disk block has been reassigned. Severity OK / Normal / Informational Cause and Action Cause: The disk has a bad block. Data has been readdressed to another disk block and no data loss has occurred. Action: Monitor the disk for other alerts or indications of poor health. For example, you may receive alert 2306.
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text is from events in the controller event log that were generated while Storage Management was not running. This text can vary depending on the situation. This alert is for informational purposes.
Local Response Agent (LRA) Number: 2061 SNMP Trap Numbers 754 Event ID — 2337 Description The controller is unable to recover cached data from the battery backup unit (BBU). Severity Critical / Failure / Error Cause and Action Cause: The controller was unable to recover data from the cache. This may occur when the system is without power for an extended period when the battery is discharged. Action: Check if the battery is charged and in good health.
Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2340 Description The BGI completed with uncorrectable errors. Severity Critical / Failure / Error Cause and Action Cause: The BGI task encountered errors that cannot be corrected. The virtual disk contains physical disks that have unusable disk space or disk errors that cannot be corrected.
Event ID — 2342 Description The Check Consistency found inconsistent parity data. Data redundancy may be lost. Severity Warning / Non-critical Cause and Action Cause: The data on a source disk and the redundant data on a target disk is inconsistent. Action: Restart the Check Consistency task. If you receive this alert again, check the health of the physical disks included in the virtual disk. Review the alert messages for significant alerts related to the physical disks.
Local Response Agent (LRA) Number: 2080 SNMP Trap Numbers 1203 Event ID — 2345 Description The virtual disk initialization failed. Severity Critical / Failure / Error Cause and Action Cause: The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective. Action: Verify the health of attached devices. Review the Alert Log for significant events. Make sure the cables are attached securely.
Event ID — 2347 Description The rebuild failed due to errors on the source physical disk. Severity Critical / Failure / Error Cause and Action Hardware RAID: Cause and Action Cause: You are attempting to rebuild data that resides on a defective disk. Action: Replace the source disk and restore from backup. Software RAID: Related Alert Information • Perform a backup with the Verify option. • If the file backup fails, try to restore the failed file from a previous backup.
Severity Critical / Failure / Error Cause and Action Cause: A write operation could not complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred and data redundancy may also be lost. Action: Replace the disk.
Event ID — 2352 Description A physical disk that was marked as missing has been replaced. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Status: Alert 2352 is a clear alert for alert 2351. Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2353 Description The enclosure temperature has returned to normal.
SNMP Trap Numbers 851 Event ID — 2355 Description Enclosure firmware download failed. Severity Warning / Non-critical Cause and Action Cause: The system was unable to download firmware to the enclosure. The controller may have lost communication with the enclosure. There may have been problems with the data transfer or the download media may be corrupt. Action: Attempt to download the enclosure firmware again. If problems continue, verify that the controller can communicate with the enclosure.
Event ID — 2357 Description SAS expander error: %1. Severity Critical / Failure / Error Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and is displayed with the alert in the alert log. This text can vary depending on the situation. Action: There may be a problem with the enclosure. Check the health of the enclosure and its components by selecting the enclosure object in the tree view.
Local Response Agent (LRA) Number: 2070 SNMP Trap Numbers 903 Event ID — 2360 Description A user has discarded data from the controller cache. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None.
Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2364 Description All virtual disks are missing from the controller. This situation was discovered during system start-up. Severity Warning Cause and Action Cause: This alert is for informational purposes.
Severity Warning / Non-critical Cause and Action Cause: The physical disk is using an incompatible technology. Action: All physical disks in the virtual disk must use the same technology. You cannot use both SAS and SATA physical disks in the same virtual disk. Remove the physical disk and insert a new physical disk that uses the correct technology. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run the Rebuild task.
Event ID — 2370 Description Redundant Path View cleared. Severity OK / Normal / Informational Cause and Action Cause: This alert is for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2371 Description Attempted import of Unsupported Virtual Disk type RAID%1.
SNMP Trap Numbers 751 Event ID — 2373 Description Attempted import of unsupported Virtual Disk type RAID %1. Severity OK / Normal / Informational Cause and Action Cause: This alert is provided for informational purposes. User is attempting to import a foreign virtual disk with unsupported RAID level on the controller. Action: None.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2376 Description Attempted import of Virtual Disk with stale physical disk. Severity OK / Normal / Informational Cause and Action Cause: User is attempting to import a foreign virtual disk with a stale physical disk. This alert is provided for informational purposes. Action: None.
Cause and Action Cause: User is attempting to import an incompatible physical drive. This alert is provided for informational purposes. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2379 Description An overflow of the foreign configuration has occurred. You can import the foreign configuration in multiple attempts.
Event ID — 2381 Description Controller preserved cache is recovered. Severity OK / Normal / Informational Cause and Action Cause: This alert is provided for informational purposes. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2382 Description An unsupported configuration was detected.
SNMP Trap Numbers 1201 Event ID — 2384 Description The Warning level set for the hot spare protection policy is violated for the Virtual Disk. Severity Warning / Non-critical Cause and Action Cause: The number of physical disks you specified for the hot spare protection policy is violated. Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.
Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2387 Description A virtual disk bad block medium error is detected. Severity Critical / Failure / Error Cause and Action Cause: Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks. Action: 1 Related Alert Information Perform a backup of the virtual disk with the Verify option selected. One of the following can occur: • Backup operation fails.
Event ID — 2389 Description The virtual disk bad block medium error is cleared. Severity OK / Normal / Informational Cause and Action Cause: Virtual disk bad blocks are cleared. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2390 Description The Cryptographic Erase operation is performed on the physical disk.
SNMP Trap Numbers 753 Event ID — 2393 Description The virtual disk is encrypted. Severity OK / Normal / Informational Cause and Action Cause: The Encrypted virtual disk operation on normal virtual disk (created using Self encrypting disks only) is successful. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2394 Description Persistent Hot Spare is enabled.
Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2396 Description The Check Consistency detected uncorrectable multiple medium errors. Severity Critical / Failure / Error Cause and Action Cause: The Check Consistency task detects uncorrectable multiple errors. Action: Replace the failed physical disk. You can identify the failed disk by locating the disk that has a red “X” for its status. Rebuild the physical disk.
Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2399 Description The Physical Disk Power status changed from 1% to 2%. Severity OK / Normal / Informational Cause and Action Cause: The physical disk power status is changed from one state to another. A physical disk can have the following power statuses: spun down, transition, and spun up. Action: None.
Severity Failure / Error Cause and Action Cause: The virtual disk configuration command did not succeed. Action: Check for the recent configuration that has not taken effect. Re-apply the configuration. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 754 Event ID — 2402 Description Changing the Physical Disk Power status from 1% to 2% failed.
Event ID — 2404 Description Virtual Disk is not available. Severity OK / Normal / Informational Cause and Action Cause: The operating system does not detect the newly created virtual disk. Action: Wait for some time. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2405 Description Command timeout on physical disk.
SNMP Trap Numbers 751 Event ID — 2411 Description Controller LKM Encryption key is changed. Severity Informational Cause and Action Cause: Using Manage Encryption Key operations, encryption key is changed. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2412 Description Controller CacheCade is resized.
Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2414 Description Controller CacheCade is deleted. Severity Informational Cause and Action Cause: This alert is provided for informational purposes. Action: None Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2415 Description Controller battery is discharging.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 903 Event ID — 2417 Description There is an unrecoverable medium error detected on virtual disk. Severity Critical / Failure / Error Cause and Action Cause: Unrecoverable medium error found on one or more member physical disks of a virtual disk. Action: Perform a backup of the virtual disk with the Verify option selected.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201 Event ID — 2425 Description State change on Physical disk from READY to Non-RAID. Severity Informational Cause and Action Cause: User triggered action. Action: Configure the drive to be non-raid using CLI/GUI.
Action: Execute "Prepare to Remove" task from UI in a PCIeSSD setup Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2430 Description Physical Device Log Exported. Severity Informational Cause and Action Cause: User triggered action. Action: Execute export log for physical device.
Severity Warning Cause and Action Cause: Last full initialization was stopped for some reason and hence the device is in security locked state. Action: Run full initialization to recover the device. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 902 Event ID — 2433 Description Physical Device is at %1% of warranted device wear-out limit. Severity Informational Cause and Action Cause: User triggered task.
Event ID — 2435 Description Physical Device is approaching read-only mode. Severity Informational Cause and Action Cause: User triggered task. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2436 Description Physical Device is in read-only mode. Severity Critical Cause and Action Cause: User triggered task. Action: None.
SNMP Trap Numbers 901 Event ID — 2438 Description The physical device blink has ceased. Severity Informational Cause and Action Cause: User triggered task. Action: None. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2440 Description The physical device available space is below threshold.
Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 904 Event ID — 2442 Description The reliability of the PCIe solid state device identified in the message degraded. Data loss is possible. Severity Error Cause and Action Cause: None Action: Back up the data on the device, and contact your service provider for further instructions.
Action: If desired, restart the Patrol Read operation at a later time. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2445 Description Cryptographic Erase operation is successfully completed on the physical disk drive identified in the message. Severity Informational Cause and Action Cause: User Triggered Task Action: No response action is required.
Cause and Action Cause: User Triggered Task Action: No response action is required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2448 Description The Remaining Rated Write Endurance (RRWE) Threshold for SAS and SATA SSD is set to . Severity Informational Cause and Action Cause: The Remaining Rated Write Endurance (RRWE) Threshold for SAS and SATA solid-state drives has been modified.
Event ID — 2450 Description The disk write cache policy is changed for Non-RAID disks. Severity Informational Cause and Action Cause: The disk write cache policy of non-RAID physical disk drives on the is changed. Action: No response action is required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 751 Event ID — 2451 Description The disk write cache policy is changed.
SNMP Trap Numbers 101 Event ID — 2453 Description The Available Spare value of the solid state device is less than the Warning threshold value. Severity Warning Cause and Action Cause: When the available spare value of the SSD falls below the warning threshold value which was either default or set by the user. Action: No response action is required.
Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 104 Event ID — 2458 Description The Available Spare value of the solid state device has reached 0%. Severity Critical Cause and Action Cause: When the available spare value of the device reaches zero. Action: No response action is required.
Action: No response action is required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 903 Event ID — 2461 Description The rebuild operation is abruptly stopped because of a media error on the physical disk drive . Severity Critical Cause and Action Cause: The rebuild operation is abruptly stopped because of a media error on the physical disk drive identified in the message.
Event ID — 2463 Description The encryption operation on the virtual drive (VD) is abruptly stopped. Severity Warning Cause and Action Cause: The encryption operation on the virtual drive (VD) is abruptly stopped. Action: No response action is required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1203 Event ID — 2464 Description The Manage Physical Disk Power property has changed.
. Event ID — 2700 Description The following journal mirror is available. %1 Severity Information Cause and Action No action required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1601 Event ID — 2701 Description The following journal mirror is being replaced.(wwn ) %1 : FluidCache. Severity Information Cause and Action No action required.
Event ID — 2703 Description There are not enough journal mirrors available to operate. : FluidCache. Severity Error Cause and Action To resolve the issue, you must ensure that there are at least two journal mirrors that are accessible. You must activate either one or more failed cache devices or use the fldc_restore utility to rebuild the node.
Event ID — 2874 Description The following Cache Device has no associated server in the configuration: %1 : FluidCache. Severity Warning Cause and Action There is a cache device specified in the configuration with no associated cache server configured. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 903 Event ID — 2875 Description The following Disk is beginning flushing.(wwn) %1 (path) %2 : FluidCache.
Event ID — 2900 Description The following cache device has failed. (wwn) %1 (path) %2 : FluidCache. Severity Error Cause and Action Replace the failed device. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 904 Event ID — 2901 Description The following storage device is either inaccessible or failed. (wwn) %1 (path) %2 : FluidCache.
Event ID — 2903 Description The following cache device has been registered. (ww n) %1 (path) %2 : FluidCache. Severity Information Cause and Action No action required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2904 Description The following cache device has been removed. (wwn ) %1 (path) %2 : FluidCache. Severity Information Cause and Action No action required.
Event ID — 2906 Description Caching is being removed for the following storage device. (wwn) %1 (path) %2 : FluidCache. Severity Information Cause and Action No action required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1201, 1501, 1601 Event ID — 2907 Description Caching has been enabled on the following storage device. (wwn) %1 (path) %2 : FluidCache.
Event ID — 2909 Description The following journal mirror is available. %1The following storage device is in an unknown state.(wwn) %1 (path) %2 : FluidCache. Severity Warning Cause and Action Service is required. Contact Technical Support. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1203, 1503 Event ID — 2910 Description Caching has been disabled for the following storage device.
Event ID — 2912 Description Resilvering for the following cache device is complete .(wwn) %1 (path) %2 : FluidCache. Severity Information Cause and Action No action required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 901 Event ID — 2913 Description The following failed cache device has completed recovery. (wwn) %1 (path) %2 : FluidCache. Severity Information Cause and Action No action required.
Event ID — 2915 Description No valid license is installed.: FluidCache. Severity Error Cause and Action A valid license must be installed. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1604 Event ID — 2916 Description Running on an evaluation license. Days remaining %1 (days): FluidCache. Severity Information Cause and Action A permanent license should be purchased.
Event ID — 2918 Description Running on an expired evaluation license. Caching functionality is disabled. Expired days: % 1: FluidCache Severity Error Cause and Action A permanent license must be installed. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1604 Event ID — 2919 Description Running on an expired/invalid license. Configuration changes are disabled.: FluidCache.
Event ID — 2921 Description A license has been removed.: FluidCache. Severity Information Cause and Action A license should be installed. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1601 Event ID — 2922 Description Not enough memory to run necessary services.: FluidCache. Severity Error Cause and Action You must run on a system with adequate memory.
Event ID — 2924 Description All cache devices have been found and registered.: FluidCache. Severity Information Cause and Action No action required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1601 Event ID — 2930 Description Even though caching was enabled in write-back mode, it is currently operating in write-through mode.: FluidCache.
Event ID — 2932 Description Caching is no longer degraded to write-through mode and is now operating in write-back mode.: FluidCache. Severity Warning Cause and Action No action required. Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: None SNMP Trap Numbers 1203, 1503, 1603 Event ID — 2933 Description Caching is no longer degraded to pass-through mode and is now operating in its configured mode.: FluidCache.
4 System Event Log Messages for IPMI Systems The tables in this chapter list the system event log (SEL) messages, their severity, and cause. NOTE: For corrective actions, see the appropriate documentation.
Event Message Severity Cause temperature sensor detected a warning . Warning Temperature of the backplane board, system board, or the carrier in the specified system exceeded the non-critical threshold. temperature sensor returned to warning state .
Event Message Severity Cause voltage sensor state de-asserted. Information The voltage of a previously reported is returned to normal state. voltage sensor detected a warning . Warning Voltage of the monitored entity exceeded the warning threshold. voltage sensor returned to normal .
Event Message Severity Cause Fan sensor returned to normal state . Information The fan specified by has returned to its normal operating speed. Fan sensor detected a warning . Warning The speed of the specified fan may not be sufficient to provide enough cooling to the system. Fan Redundancy sensor redundancy degraded.
Event Message Severity Cause Fan redundancy is lost. Critical One or more required fans may have failed or removed and hence, the redundancy was lost. Fan redundancy is degraded. Warning One or more fans may have failed or removed and hence, the redundancy has been degraded. Processor Status Events The processor status messages monitor the functionality of the processors in a system. These messages provide processor health and warning information of a system. Table 8.
Event Message Severity Cause configuration error was deasserted. Information This event is generated when the earlier processor configuration error was corrected. throttled was asserted. Warning This event is generated when the processor slows down to prevent overheating. throttled was deasserted. Information This event is generated when the earlier processor throttled event was corrected. CPU has an internal error (IERR).
Event Message Severity Cause power supply sensor returned to normal state. Information This event is generated when the power supply that failed or removed was replaced and the state has returned to normal. PS Redundancy sensor redundancy degraded. Information Power supply redundancy is degraded if one of the power supply sources is removed or failed. PS Redundancy sensor redundancy lost.
Event Message Severity Cause PS 1 Status: Power supply sensor for PS 1, configuration error was asserted. Warning/Critical This event is generated when an invalid power supply configuration is detected. PS 1 Status: Power supply sensor for PS 1, configuration error was deasserted. Information This event is generated when the power supply has recovered from an earlier invalid configuration. Power supply is present. Information This event is generated when the power supply is plugged in.
Event Message Severity Cause Fan failure detected on power supply . Critical The specified power supply fan has failed. Communication has been restored to power supply . Information This event is generated when the power supply has recovered from an earlier communication problem. A power supply wattage mismatch is detected; power supply is rated for watts.
E v e n t M e s s a g e Severity Cause Critical This event is generated when the chipset in the ECC error correction rate exceeds a predefined limit. Warning This event is generated when there is a memory error correction on a particular Dual Inline Memory Module (DIMM). Critical This event is generated when the chipset is unable to correct the memory errors. Usually, more than on DIMM is listed because a single DIMM may or may not be identifiable, depending on the error.
Event Message Severity Cause BMC OS Watchdog performed system power cycle. Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to power cycle. The OS watchdog timer reset the system. Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to reboot.
Event Message Severity Cause Memory Mirrored redundancy regained. Information This event is generated when the redundancy lost or degraded earlier is regained in a mirrored memory configuration. Memory Spared redundancy degraded. Warning This event is generated when there is a memory failure in a spared memory configuration. Memory Spared redundancy lost. Critical This event is generated when redundancy is lost in a spared memory configuration. Memory Spared redundancy regained.
Hardware Log Sensor Events The hardware logs provide hardware status messages to the system management software. On particular systems, the subsequent hardware messages are not displayed when the log is full. These messages provide status and warning messages when the logs are full. Table 13. Hardware Log Sensor Events Event Message Severity Cause Log full detected. Critical This event is generated when the SEL device detects that only one entry can be added to the SEL before it is full. Log cleared.
Event Message Severity Cause Drive in failed array was asserted. Critical This event is generated when the drive is placed in the fail array. Drive in failed array was deasserted. Information This event is generated when the drive is removed from the fail array. Drive rebuild in progress was asserted. Information This event is generated when the drive is rebuilding. Drive rebuild aborted was asserted.
Event Message Severity Cause The chassis is open while the power is off. Critical This event is generated when the intrusion sensor detects an intrusion while the system is off. The chassis is closed while the power is off. Information This event is generated when the earlier intrusion has been corrected while the power is off. BIOS Generated System Events The BIOS-generated messages monitor the health and functionality of the chipsets, I/O channels, and other BIOS-related functions. Table 16.
Event Message Severity Cause System Board PFault Fail Safe state asserted. Critical This event is generated when the system board voltages are not at normal levels. System Board PFault Fail Safe state deasserted Information This event is generated when earlier PFault Fail Safe system voltages return to a normal level. Memory Add (BANK# DIMM#) presence was asserted. Information This event is generated when memory is added to the system. Memory Removed (BANK# DIMM#) presence was asserted.
Event Message Severity Cause CPU Bus PERR transition to non-recoverable. Critical This event is generated when the processor bus PERR enters a non-recoverable state. CPU Init Err transition to non-recoverable. Critical This event is generated when the processor initialization enters a non-recoverable state. CPU Machine Chk transition to non-recoverable. Critical This event is generated when the processor machine check enters a non-recoverable state.
Event Message Severity Cause A bus correctable error was detected on a component at slot . Critical This is generated when the system has detected bus correctable errors. A bus uncorrectable error was detected on a component at bus device function <>number>. Critical This is generated when the system has detected bus uncorrectable errors. A bus uncorrectable error was detected on a component at slot .
Event Message Severity Cause Correctable memory error rate exceeded for . Critical This event is generated when correctable ECC errors reach a critical rate. Memory device at location is overheating. Critical This event is generated when system memory reaches critical temperature. An OEM diagnostic event occurred. Information This event is generated when an OEM event occurs. OEM events can be used by the service team to better understand the cause of the failure.
Event Message Severity Cause Failed to get Link Tuning or FlexAddress data from iDRAC. Critical This event is generated when BIOS could not obtain virtual MAC address or Link Tuning data from iDRAC. An unknown system hardware failure detected. Critical This event is generated when an unknown hardware failure is detected. POST fatal error Critical This event is generated when a fatal error occurs during system boot. For more information, see POST Code Errors.
Fatal Error Code Description Cause 8C SMI initialization failure. This error code indicates SMI initialization failure. C0 Shutdown test failure. This error code indicates a shutdown test failure. C1 POST Memory test failure. This error code indicates bad memory detection. C2 RAC configuration failure. Check screen for the actual error message. C3 CPU configuration failure. Check screen for the actual error message. C4 Incorrect memory configuration. Memory population order not correct.
Cable Interconnect Events The cable interconnect messages in the table are used for detecting errors in the hardware cabling. Table 19. Cable Interconnect Events Description Severity Cause Cable sensor Configuration error was asserted. Critical This event is generated when the cable is not connected or is incorrectly connected. Cable sensor Connection was asserted. Information This event is generated when the earlier cable connection error was corrected.
Power And Performance Events The power and performance events are used to detect degradation in system performance with change in power supply. Table 21. Power And Performance Events Description Severity Cause System Board Power Optimized: Performance status sensor for System Board, degraded, was deasserted Normal This event is generated when system performance was restored.
Description Severity Cause The system performance degraded because of thermal protection. Warning This event is generated when a change in thermal protection degrades system performance. The system performance degraded because cooling capacity has changed. Warning This event is generated when a change in cooling degrades system performance. The system performance degraded because power capacity has changed. Warning This event is generated when change in power supply degrades system performance.
Miscellaneous Events The following table provides events related to hardware and software components like mezzanine cards, sensors, firmware etc. and compatibility issues. Table 23. Miscellaneous Events Description Severity Cause System Board Video Riser: Module sensor for System Board, device removed was asserted Critical This event is generated when the required module is removed.
Description Severity Cause LinkT/FlexAddr: Link Tuning sensor, failed to get link tuning or flex address data from BMC/iDRAC was asserted Critical This event is generated when link tuning or Flex address information is not obtained from BMC/iDRAC. The is removed. Critical This event is generated when the device was removed. The is inserted. Information This event is generated when the device was inserted or installed.
Description Severity Cause Internal Dual SD Module redundancy is lost. Critical This event is generated when either one of the SD cards or both the SD cards are not functioning properly.